Eaton LCD Lift Flat Panel Display System. Installation Guide

Similar documents
Eaton Heat Containment System (HCS) Installation Guide

Heat Containment System (HCS)

Flat Panel Static Wall Mount MSP-SS (GSM-210)

Innovative Americans, LLC. HD Media Pack Installation Manual

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

INSTALLATION INSTRUCTIONS

SEQUEL 6051/6052 LIFT DESK

EVOLVE1-M MONITOR ARM

Cycles Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

CENTRO 6451/6452 LIFT DESK

CIB 3047 (14B) 10-Button Voice Terminal Fixed Desk Stand and Wall Mount (32007)

Assembly and Setup Manual

TDM To MiniMech conversion ProceDure

flipit SFI & IFI Computer Desks

The Minimalist, Modular, Wall-Mounted Standing Desk

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

DYNAVISION D2 TM INSTALLATION MANUAL

KRONOS 6752 LIFT DESK

Nikon Focus Drive Manual

Titan Media Cart. Installation and Operation Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

DIGITAL Server Rackmount Installation Guide

Assembly Instructions

C764i Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

G12/G12x USER S MANUAL

Rack Installation Instructions

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

Motorized Ceiling TV Mount

CLIMB2 DUAL MONITOR SIT/STAND WORKSTATION

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

EXN4000 Storage Expansion Unit Installation and Setup Instructions

PC9/P9 CPU Card Replacement

CUBE Micro Station User Guide

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

SPECIFICATION & INSTALLATION GUIDE

Peel/Rewind Upgrade Kit

E1135C PDU and Pod Upgrade Procedure

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

PFPDARM3 Product Illustration

Sit-Stand Monitor Arm

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

System Storage EXP3000 Rack Installation Instructions

Quick start guide for i5 520 ( or )

Assembly and Setup Manual

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

FLEXBOX. Installation Guide

UPLIFT 2-Leg Height Adjustable Standing Desk (Version v4 Control Box)

TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS

Rear Consumer LCD Hinge Assembly Large Displays

Remote Control Motorized TV Ceiling Mount

MBE Mounts and Adapters

Quad Monitor Desk Stand - 13" to 24" Installation Instructions

INSTALLATION MANUAL. LO SIDE BOX ADD-ON KIT For driver or passenger side configurations TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK

V.I.A. - Monitor Shroud

Replacement Instructions

Gateway Profile 4 service guide

Compass sit-to-stand (STS)

N3240 Installation and Setup Instructions

LED Lighting Kit For Elara NanoEdge Fixed Frame. Installation Guide. Attention: Read this guide before assembling your screen.

2T-RMSMC System Management Station Kit Installation Guide

Wall-Mounted Sit-Stand Desk - Single Monitor

PowerFlex 750-Series Power Option Cabinets

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Installing the Cisco MDS 9020 Fabric Switch

Installing a Power over Ethernet injector

Liebert XDA Air Flow Enhancer. User Manual

To connect the AC adapter:

Additional Help For additional installation instructions and videos, please visit our website at What s Included

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Shutter and rail locking device for low-voltage switchgear

IBM. Rack Installation Instructions

Cutter Option Installation Instructions

Wall Mount Kits. To check which phone model you have, press Applications number field shows your phone model. and select Phone information.

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

Replacing the Power Supply

NAV-1 Lens Support. NAV-2 Lens Support BEFORE YOU BEGIN

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Quick Installation Guide

H3C S12500 Routing Switch Series

Whisper-Ride

INSTALLATION INSTRUCTIONS

ASSEMBLY AND ADJUSTMENT

Upgrading LVDS Cables Instruction Sheet

2 x Dynamic Arms on 135 Post with C-Clamp

IBM Systems. Quick start guide for IBM System p5 505 ( )

Charging Cabinet Owner s Manual

N3150 Installation and Setup Instructions

MD-BSL15W / SPRING-LOADED TWIN-ARM. For ( cm) LCD desktop computer. User Manual

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

A-MOD DESKTOP OWNER S MANUAL

SAVE THESE INSTRUCTIONS

Service Bulletin. MiTek. RoofTracker Roof Truss Roller Press. Machinery Affected: Adding an Operator Platform. Machinery Division

Transcription:

Eaton LCD Lift Flat Panel Display System Eaton LCD Lift Flat Panel Display System Installation Guide

Copyright 2011 Eaton Corporation, Worcester, MA, USA. All rights reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written consent of Eaton Corporation. Compass, Profile, LINX, and Lift are registered trademarks of Eaton Corporation. Phillips is a registered trademark of Phillips Screw Company. All other trademarks are the property of their respective owners.

Table of Contents About this Guide Audience General Conventions Documentation Page v v v 1 Before you Begin Introduction 1 Important Safety Information 1 Tools you Will Need 1 Fasteners you May Be Using 2 LCD Lift Configurations 2 2 Installing the LCD Lift in Work Surface Prerequisites 3 Installation Overview/Checklist 3 Tools You Will Need 3 Unpack the Box Contents 4 Cut Opening in Work Surface (if applicable) 4 Install the LCD Electric Lift in Work Surface 5 Install the Actuator Switch 9 Route AC Wiring 11 3 Installing the Monitor(s) Install the LCD Monitor in the Lift 13 Route Monitor Cables 15 Route Monitor Wiring 16 4 Testing and Operating the Lift Test the Lift 17 Operate the Lift 17 Support and Resources 17

About this Guide This document describes how to install the Eaton LCD Lift Flat Panel Display System in your facility. Audience This document is intended for installers and/or personnel who are installing the Eaton LCD Lift Flat Panel Display System in your facility. General Conventions Before you start the installation process, it is important to understand the conventions used in this publication. Convention Meaning Bold type Indicates notes, cautions or warnings that provide important information. Failure to follow these warnings may cause personal injury and/or product damage. Italic type Indicates titles of publications or information that the user must supply, such as filenames (if applicable). Underlined type Indicates links (if applicable). 1. Numbered lists Indicates procedures that you must follow in a sequential order. ACRONYMS Acronyms are defined at the first occurrence in the document. The acronym definition appears first followed by its acronym in parenthesis. For example: electrostatic discharge (ESD). Documentation This document can be obtained from our website at http://www.wrightline.com by following this procedure: 1. Click on the Library icon, and then select Installation Manuals. 2. Click on Office/Modular Office Furniture section, and then select Compass, LINX, or Profile. 3. Click on the LCD Lift link to view and print this manual. Browse the documentation library for additional documents pertaining to this product. v Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Chapter 1 Before you Begin Introduction The LCD Lift is a convertible flat panel desk solution that provides innovative housing for your LCD Flat Panel Monitor technology. The LCD Lift is now available for the Compass, LINX and Profile lines of modular furniture and can be retrofitted to any of Eaton s technical work surface furniture. This solution is ideal for computer labs, education and training environments, lobby and reception areas or even your personal workstation. Your LCD flat panel electronically elevates to an optimal viewing position with the push of a button. When not in use, you may retract your display into a locked, secure enclosure under the desktop, maximizing your work surface area. This document describes how to install the LCD Lift in your modular desk system. Caution: To prevent personal injury and product damage, it is strongly recommended that the unpacking, moving, and assembly processes be performed by two or more people. Important Safety Information Please follow these safety guidelines as you unpack, move, and assemble the components of the work surface. Adherence to these guidelines will prevent personal injury and potential product damage. When lifting units, there should be at least one person for every 40 lbs. of weight to be lifted. Do not, under any circumstance, stand on the Flat Panel Display System. Do not stand on the display system to load monitors. Tools you Will Need The following tools may be required to successfully install the lift. Electric or cordless drill Phillips head driver attachment for the drill Phillips head hand screwdriver (magnetic tip suggested) 3/8 nut driver 1/4 socket / 1/4 socket driver In this Chapter Refer to the following table for information on a specific topic. Topic See Page # Important Safety Information 1 Tools you Will Need 1 Fasteners you May Be Using 2 LCD Lift Configurations 2 1 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Before you Begin Fasteners you May Be Using Depending on the lift you ordered and the size of your work surface, you may need to use some or all of the following fasteners: #64857, #10 x 3/4 Large 1/4 Hex Head Wood Screw #56529, #6AB x 3/4 Philips Head Wood Screw #68374, #8AB x 1/2 Philips Head Sheet Metal Screw #59103, #10AB x 3/4 Philips Head Wood Screw #82787, M4 x 10mm Philips Head Machine Screw #87799, #10 Lock Nut #82785, #10 Flat Washer (large) LCD Lift Configurations The following table outlines the various LCD Lift configurations and monitor options based on the size of your work surface. Installations can be configured for three possible monitor solutions as indicated below. Lift Box Size Minimum Work Single LCD Dual LCD Tri-LCD Monitor Surface Size Monitor Size Monitor Size Size 24 36 24 15 N/A 36 48 24 18 N/A 48 60 27 24 15 The following table provides the maximum display monitor sizes for the LCD Lift. Monitor sizes may vary from manufacturer to manufacturer; therefore, use this chart as a guideline for the maximum allowable monitor size for use with this product. LCD Flat Panel Display Monitor Physical Dimensions 27 widescreen 25.88 W, 16.3 H, 4.2 D* 24 widescreen 22.38 W, 16.3 H, 4.2 D* 21 widescreen 20.0 W, 16.3 H, 4.2 D* 15 standard 11.25 W, 16.3 H, 4.2 D* 18 widescreen 17.32 W, 13.93 H, 4.2 D* Notes: Weight capacity: 40 lbs Depth (max)*: 4.2 D (measured from front of bezel to rear of mounting surface) All dimensions are specified to maximum conditions Can be retrofitted with hand power tools www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 2

Chapter 2 Installing the LCD LIFT in Work Surface This chapter describes how to install the LCD Lift in your modular desk system. This product supports up to three monitor configurations depending on the size of your work surface. For a list of possible monitor configurations, refer to the LCD Lift Configurations section in Chapter 1. Prerequisites Before the LCD Lift is installed, the work surface must be fully installed. For instructions on installing your work surface, visit our website at http://www.wrightline.com and follow these procedures: 1. Click on the Library icon. 2. Click on Installation Manuals. 3. Browse the list of products and select the appropriate installation manual for your particular work surface. Installation Overview / Checklist The following checklist is intended to be a quick reference to make sure all hardware components of the LCD Lift are installed in the proper order. For further information on any of these steps, refer to the detailed instructions in the corresponding sections of this manual. Component Refer to Cut Work Surface Opening (if necessary) Page 4 Install the LCD Electric Lift Page 5 Install the Actuator Switch Page 9 Route AC Wiring Page 11 Install the Monitor(s) Page 13 Route Monitor Cables Page 15 Route Monitor Wiring Page 16 Test and Operate the Lift Page 17 Tools You Will Need Refer to the tools and fasteners listed in Chapter 1 for the materials you will need to properly install the LCD Lift in your modular desk system at your facility. In this Chapter Refer to the following table for information on a specific topic. Topic See Page # Unpack the Box Contents 4 Cut Work Surface Opening (if applicable) Install the LCD Electric Lift in Work Surface 4 5 Install the Actuator Switch 9 Route AC Wiring 11 3 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Installing the LCD Lift in Work Surface Unpack the Box Contents Before you begin the installation process, ensure that the following parts are included in your shipment. If any components are missing, then please contact Eaton s Technical Support Center at to.support@eaton.com. Part Qty Linear Work Surface, 72 W x 30 Dual Monitor Lift (if ordered) 1 24, 36 or 48 Lift Assembly box based on order 1 Work Surface with Dual LCD, 60 W x 30 1 24 Monitor 2 #10 x 3/4 lg hex head self-tap screws 10 Cut Work Surface Opening (if applicable) If you are installing the LCD Electric Lift in an Eaton modular furniture work surface with no cutout, then you must cut an opening in the work surface to accommodate the lift. Refer to the table and diagram below for cutout dimensions based on the lift you ordered. If you ordered and are installing the Eaton factory-assembled LCD Electric Lift with a predrilled work surface opening, then skip this step and proceed to the next section. Lift Size Hole Width (See A) Hole Depth (See B) 24 26-13/16 8-5/8 36 38-13/16 8-5/8 48 48-3/8 8-5/8 Work surface opening 3/8 diameter hole contoured on corner (Qty 4) Work surface Proceed to the next section for instructions on installing the LCD Electric Lift in the work surface. www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 4

Installing the LCD Lift in Work Surface Install the LCD Electric Lift in Work Surface Follow these procedures to install the LCD Electric Lift in the work surface. Lifts are available in 24, 36, or 48 lift assemblies. The lift is factory-assembled and ready to use. These instructions describe how to install the lift in your modular desk system. 1. Unpack the box contents. Remove the LCD Electric Lift from the box and all contents. 2. Remove the front cover from the LCD Lift. 3. Remove the plastic bag kit contents (includes screws, cable ties and monitor hardware) from the unit. Set it aside. 4. Extend the lift carriage approximately 6 8 inches above the top bezel for easier handling and movement as shown in the following illustration. Work surface front Raise 6-8 from above workstation top Front cover Top bezel 5. With one person on each end of the lift, place your hands inside the top bezel (see figure below), lift the LCD box, and place it inside the work surface opening. Place hands here Top bezel Only top bezel shown for clarity Place hands here Workstation top Work surface opening 5 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Installing the LCD Lift in Work Surface 6. Ensure that the lift is properly seate d in the desk opening, centered, and flush with the work surface as shown in the following figure. 7. Apply temporary AC power to the lift by plugging the power cord into an electrical wall outlet. Remove the tie wraps from the power cord before plugging it into the electrical outlet. An extension cord may be needed. 8. Now that the lift is installed inside the desk opening and seated properly, manually move up the carriage to approximately 12 inches so that you have full access to the lift s hardware components as shown in the figure below. Work surface front Raise 12 from above workstation top. 9. If you are installing the lift into a 60 or larger work surface, then ensure the work surface is level before you proceed to the next step. www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 6

Installing the LCD Lift in Work Surface 10. From inside the lift box, underneath the top bezel, using your hand, locate the four screw holes along the front of the lift frame as shown in following figure. 1. Locate holes underneath bezel (inside lift box) 2. Insert and tighten four screws Top bezel Front of lift 11. Using a ratchet driver, insert the four #10 x 3/4 large self-tap hex wood screws and washers (from the parts bag that was put aside) into the four pre-located holes from inside the opening of the lift along the front side of the top bezel as illustrated above. 12. Using a ratchet driver, insert one #10 x 3/4 large self-tap hex screw into the hole on each end of the lift frame as illustrated below and tighten. (1) #10x3/4 Large self-tap hex wood screw Box cover shown for clarity only Front (1) #10x3/4 Large self-tap hex wood screw Note: At this time, do not install the screws for the rear of the lift frame since it is inaccessible. 13. Press the motor control lift button to raise the monitor lift to its fully extended upright position allowing you access to the other hardware components. 7 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Installing the LCD Lift in Work Surface 14. Underneath the work surface, through the front cover opening, insert the remaining four #10 x 3/4 large self-tap hex screws and washer into the side holes on the back rear of the lift frame as shown below and tighten. 1. Locate holes underneath back of bezel (inside lift box) 2. Insert and tighten four screws (back view shown) Front view Back view Box cover shown for clarity only www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 8

Installing the LCD Lift in Work Surface Install the Actuator Switch Follow these procedures to install the Actuator Switch. 1. Uncoil the switch and cord. 2. Using the two (2) #8AB Phillips screws provided, install the Actuator Switch near the front edge of the desktop as shown in the following illustration. Based on user preference, you have the option of installing the switch either on the left side or the right side of the work surface. 3. Run the Actuator Switch cord either through the center holes or the top left or top right holes shown in the following illustration. 9 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Installing the LCD Lift in Work Surface Cable exit holes (top left or right) Cable exit holes (center) 4. Route the Actuator Switch cord around the box and secure it using the cord clips provided. See the following illustration. Wire to be routed around box Work surface shown from bottom for ease of illustrating actuator switch installation www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 10

Installing the LCD Lift in Work Surface Route AC Wiring To route the AC wiring, do the following: 1. If you have not already done so, uncoil the AC power cord that was included in your shipment. 2. Run the AC power cord through the 2 diameter hole on the left-side of the lift box (see figure below) and exit to an electrical AC power outlet. Plug the AC power cord in the electrical outlet to apply power. Run AC power cord through this hole to electrical outlet The Actuator wiring has now been completed and power has been applied. Proceed to the following section for instructions on installing the monitor(s). 11 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Chapter 3 Installing the Monitor(s) This chapter describes how to the install the monitors on your Eaton LCD Lift Flat Panel Display System. Follow these procedures to install the LCD monitor(s) to the LCD Lift and route the cables. Install the LCD Monitor in the Lift Follow these procedures to install the LCD Monitor to the LCD Lift. 1. Remove the stand (if equipped) from the LCD Monitor. 2. Fasten the VESA Mounting Plate assembly to the back of the LCD monitor with the M4 screws provided and shown in the illustration below. 3. Tilt the Monitor Support Plate forward. In this Chapter Refer to the following table for information on a specific topic. Topic See Page # Install the LCD Monitor to the Lift 13 Route Monitor Cables 15 Route Monitor Wiring 16 13 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Installing the Monitor(s) 4. Position the Monitor/Mounting Plate onto the Monitor Support Plate with the threaded studs protruding through the slots in the plate as shown in the illustration below. 5. Secure the Monitor/Mounting Plate assembly to the Support Plate with the two (2) lock washers and two (2) plastic wing nuts that are provided. Note: The wing nuts must be in the vertical position when fully tightened. 6. Install the Monitor Lock assembly to the back of the Monitor Support Plate as shown in the following illustration. Slide the top of the Lock assembly under the hook tabs on the support plate and then lock the unit as shown in the following illustration. Space brackets Lower track adjustment brackets 7. For 36 or 48 lifts, use space bracket hardware to adjust the monitors to the desired location. Brackets are located under the carriage cover. See figure above. 8. Use ¼ x 20 Kep nuts to adjust. www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 14

Installing the Monitor(s) Route Monitor Cables Follow these procedures to route the monitor cables. 1. Pass all monitor cables through the cable port in the bottom of the Monitor Carriage. 2. Route the cables through the port in the LCD Lift frame. Route the cables as shown in the following illustration. Secure and tie cables to the bottom of the frame using a selfadhesive grommet. Important: Not properly securing cables inside the lift could result in a safety hazard where cables could be severed during operation. 3. Ensure that there is enough slack in the cables to allow complete travel of the Monitor Carriage. Monitor lift should be in up position Monitor carriage Route cables using tie cables and anchor to bottom of lift box using self-adhesive grommet Cable port 15 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

Installing the Monitor(s) Route Monitor Wiring Follow these procedures to route the monitor wiring. All monitors must be installed in carriage assemblies before routing can occur. 1. For 24 LCD Lifts, insert the monitor cable through the center hole in the monitor carriage as shown in the illustration below. 2. For 36 and 48 LCD Lifts, insert the monitor cable through one of the side holes as shown in the illustration below. Space bracket hardware Insert cables here for 36 and 48 lifts Insert cables here for 24 lift Insert cables here for 36 and 48 lifts 3. Tie together the data cable and AC cable and exit the cable bundle through the monitor hole shown in the following illustration. Monitor 1 cables Monitor 2 cables www.eaton.com/powerquality MN211002EN 06-2011 Eaton LCD Lift Flat Panel Display System Installation 16

Chapter 4 Testing and Operating the Lift This chapter describes how to test and operate your LCD Lift Flat Panel Display System. Test the Lift To test the operation of the LCD Lift, follow these instructions: 1. Press the Actuator Switch button to raise the lift up and down, ensuring that the lift is operational and functioning properly. 2. If the LCD Lift does not raise or lower as expected, then review and repeat the installation instructions in this document to ensure that all steps have been completed. 3. Re-test the lift again to ensure that it raises and lowers as expected. Operate the Lift Press the Actuator Switch buttons to raise and lower the lift carriage to the desired height. Ensure that the lift is operational and functioning properly. Actuator switch Support and Resources For additional documentation about this product, visit the www.wrightline.com website and click on the Library icon. For technical support assistance, email Eaton s Technical Support Center at to.support@eaton.com. In this Chapter Refer to the following table for information on a specific topic. Topic See Page # Test the Lift 17 Operate the Lift 17 Support and Resources 17 17 Eaton LCD Lift Flat Panel Display System Installation www.eaton.com/powerquality MN211002EN 06-2011

To contact an Eaton salesperson or local distributor, please visit www.eaton.com/wrightline or call 800-225-7348. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2011 Eaton Corporation All Rights Reserved