IBM Spectrum Protect Snapshot for VMware 4.1.6

Similar documents
IBM Spectrum Protect Snapshot for VMware 4.1.3

IBM Spectrum Protect Snapshot for VMware Installation Planning Sheet

IBM Tivoli Storage FlashCopy Manager for VMware Installation Planning Sheet

IBM Spectrum Protect Snapshot for Unix Installation Planning Sheet

IBM Spectrum Protect Snapshot for Unix Installation Planning Sheet

IBM Tivoli Storage FlashCopy Manager for Custom Applications Version Installation and User Guide UNIX and Linux IBM

IBM Spectrum Protect for Virtual Environments Version Data Protection for VMware Installation Guide IBM

IBM Spectrum Protect for Virtual Environments Version Data Protection for VMware Installation Guide IBM

Stellar performance for a virtualized world

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

IBM Tivoli Storage FlashCopy Manager for DB2 Version Installation and User's Guide UNIX and Linux IBM

Managing Copy Services

IBM Spectrum Protect Snapshot for UNIX

IBM Spectrum Protect Snapshot Version DB2 UNIX and Linux IBM

What s New in Catalogic ECX 2.5

IBM Spectrum Protect Snapshot for Custom Applications Version Installation and User Guide UNIX and Linux IBM

IBM Spectrum Protect TM Snapshot: How to find the information you need

IBM Spectrum Protect Snapshot for DB2 Version Installation and User's Guide UNIX and Linux IBM

Unified Management for Virtual Storage

OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3

IBM Tivoli Storage FlashCopy Manager for UNIX

IBM Tivoli Storage FlashCopy Manager for Custom Applications Version Installation and User Guide UNIX and Linux IBM

IBM Storage Management Console for VMware vcenter. Version Release Notes. First Edition (June 2011)

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family

VMware vsphere with ESX 4.1 and vcenter 4.1

IBM Storage Management Console for VMware vcenter. Version Release Notes. First Edition (July 2011)

IBM Tivoli Storage FlashCopy Manager for Oracle, and Oracle in a SAP environment Version UNIX and Linux. Installation and User's Guide IBM

IBM Tivoli Storage FlashCopy Manager Version Installation and User's Guide for UNIX and Linux

SAN Implementation (SANIW)

IBM Storage Management Console for VMware vcenter. Version User Guide. Publication: GA

IBM Tivoli Storage FlashCopy Manager Version 4.1. Installation and User's Guide for UNIX and Linux

Protecting Microsoft SQL Server databases using IBM Spectrum Protect Plus. Version 1.0

iscsi Target Usage Guide December 15, 2017

IBM XIV Adapter for VMware vcenter Site Recovery Manager 4.x Version User Guide GA

SnapCenter Software 4.0 Concepts Guide

Data Protection Guide

IBM IBM Storwize V7000 Technical Solutions V2. Download Full Version :

IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version Release Notes IBM

IBM Storwize V7000: For your VMware virtual infrastructure

IBM TotalStorage DS8800 Disk Storage Microcode Bundle v6 Release Note Information

Acronis Backup Advanced 11.7 Update 1

IBM Storage Management Console for VMware vcenter. Version User Guide. Publication: GA (June 2011)

IBM Tivoli Storage FlashCopy Manager 4.1.x for UNIX

VMware vsphere 4. Architecture VMware Inc. All rights reserved

IBM Copy Services Manager Version 6 Release 2. User's Guide IBM SC

Data Protection Guide

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Jeremy Canady. IBM Systems and Technology Group ISV Enablement March 2013

VMware vsphere with ESX 6 and vcenter 6

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

IBM Copy Services Manager Version 6 Release 2. User's Guide IBM SC

SnapCenter Software 2.0 Installation and Setup Guide

IBM Copy Services Manager Version 6 Release 1. Release Notes August 2016 IBM

Hitachi Virtual Storage Platform

NexentaStor VVOL

Data Protection Guide

IBM Spectrum Protect Plus Version Installation and User's Guide IBM

Data Protection Guide

HP Data Protector 7.0 Virtualization Support Matrix

VMware vsphere 5.5 Professional Bootcamp

IBM Storage Driver for OpenStack Version Release Notes IBM

Application Integration IBM Corporation

IBM Copy Services Manager Version 6 Release 2. User's Guide IBM SC

Cisco UCS Director Tech Module IBM Storage Arrays. June 2016

IBM. Release Notes November IBM Copy Services Manager. Version 6 Release 1

Installation and Cluster Deployment Guide for VMware

Virtual Server Agent for VMware VMware VADP Virtualization Architecture

"Charting the Course... VMware vsphere 6.7 Boot Camp. Course Summary

Arcserve Backup for Windows

Additional Information about Using DS8000 with Non-IBM Software

IBM Storwize V7000 Technical Solutions V1

Managing VMware ESXi in the Datacenter. Dwarakanath P Rao Sr Partner consultant 6 th November 2008

Detail the learning environment, remote access labs and course timings

Copy-Based Transition Guide

Exam Name: VMware Certified Professional on vsphere 5 (Private Beta)

HP StorageWorks. EVA Virtualization Adapter administrator guide

IBM Europe Announcement ZP , dated April 8, 2008

IBM Tivoli Storage Manager Version Introduction to Data Protection Solutions IBM

Vendor: IBM. Exam Code: Exam Name: Storage Sales V2. Version: DEMO

IBM Spectrum Protect for Databases Version Data Protection for Microsoft SQL Server Installation and User's Guide IBM

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series

VMware vsphere 6.5: Install, Configure, Manage (5 Days)

ETERNUS SF AdvancedCopy Manager SRA Version 2.4. User's Guide. Windows(64)

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

Installation and Cluster Deployment Guide for VMware

Dell Storage Compellent Integration Tools for VMware

IBM Spectrum Control. Monitoring, automation and analytics for data and storage infrastructure optimization

SnapCenter Software 4.1. Administration Guide. December _C0 Updated for 4.1.1

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version :

Disaster Recovery-to-the- Cloud Best Practices

VMware vsphere with ESX 4 and vcenter

IBM Spectrum Protect Version Introduction to Data Protection Solutions IBM

VMware vsphere. Administration VMware Inc. All rights reserved

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Exam Name: Midrange Storage Technical Support V2

IBM XIV Provider for Microsoft Windows Volume Shadow Copy Service. Version 2.3.x. Installation Guide. Publication: GC (August 2011)

MAX Data 1.1 Installation and Setup Guide. November _A0

1) ADDITIONAL INFORMATION

IBM Flex System and IBM PureFlex Firmware Updates Best Practices. Flex Version (October 4, 2013)

Benefits of the IBM Storwize V7000 Real-time Compression feature with VMware vsphere 5.5

Transcription:

IBM Spectrum Protect Snapshot for VMware 4.1.6 Objective of this document This document provides comprehensive information on the complete environment required to support IBM Spectrum Protect Snapshot for VMware based solutions. It helps you to: Prepare for implementation - complete this check list prior to implementation start to avoid late issues. Identify and involve all responsible organizations required for implementation. Identify proper release levels of ancillary software. Get the most current tips and hints for installation. Tip: Beginning with Version 4.1.3, IBM Tivoli Storage FlashCopy Manager is now IBM Spectrum Protect Snapshot. Some applications such as the software fulfillment systems and IBM License Metric Tool use the new product name. However, the software and its product documentation continue to use the Tivoli Storage Manager product name. To learn more about the rebranding transition, see http://www.ibm.com/support/docview.wss?uid=swg21963634. Note: This document refers to the FlashCopy Storage Systems IBM System Storage DS8000, IBM System Storage SAN Volume Controller (SVC), IBM Storwize V7000, IBM FlashSystem, IBM XIV Storage System, IBM Spectrum Accelerate, IBM N Series, and NetApp. Copyright IBM Corp. 2001, 2017 1

1. Hardware Requirements (general) 1.0.1 1.0.2 1.0.3 1.0.4 1.0.5 1.0.6 A VMware vsphere environment consisting of one vcenter server and one or more ESX/ESXi hosts. One Linux server for the IBM Spectrum Protect Snapshot for VMware installation. This server can either be a physical server or a virtual machine running within the vsphere environment. SAN connectivity to storage subsystems is not required for this server. The Linux server (1.0.2) has a LAN connection to the control interface (or CIM agent) of the storage subsystem or SVC storage cluster. LUNs of the VMware datastores to be backed up within one backup run must not be distributed over multiple disk storage subsystems / SVC storage clusters. (DS8000): Only one LUN per VMware datastore is supported For IBM Spectrum Protect Snapshot operations the LUNs of the disk storage subsystem intended to be used as target volumes must be accessible to the ESX/ESXi host used as auxiliary ESX host (see profile parameter AUXILIARY_ESX_HOST). This applies to DS storage devices and also to SVC and IBM Storwize V7000 if preassigned volumes are used. For XIV, N Series or NetApp, and SVC / Storwize using the dynamic target allocation option, the target LUNs will be created automatically during snapshot process and will be assigned to the auxiliary ESX host. See documentation of profile parameter HOST_NAME_MAPPING in the User's manual for more details. Note: In case of preassigned volumes are used, the AUXILIARY_ESX_HOST parameter needs to be set in the configuration profile so that the forced mount operation can be executed as part of the backup operation. A source volume and its corresponding target volume must be of same size (in case of target volumes are created by the user). DS requires source and target volume pairs be located in the same disk storage subsystem. For SVC and IBM Storwize V7000 those can be located in different storage devices within one and the same SVC cluster. Copyright IBM Corp. 2001, 2017 2

1.1 Hardware Requirements for DS8000 IBM System Storage DS8000 (DS8100, DS8300, DS8700, DS8800 or DS8870) with the Point in Time Copy feature enabled. With DS8000 Release 4.1 (bundle 64.1.16.0) and later the embedded CIM agent in the HMC is enabled and configured by default and can be used with IBM Spectrum Protect Snapshot. 1.1.1 Note: IBM CIM Agent for DS Open API version 5.4.2 has a known problem with refresh of an incremental FlashCopy using IBM Spectrum Protect Snapshot. Therefore make sure that CIM Agent 5.4.2.xx is not used. Please upgrade the DS microcode to a level that provides CIM Agent >= 5.4.3 (for example: DS8000 bundle version 64.30.78.0 comes with CIM Agent 5.4.3.52) DS8000 LIC level for FlashCopy to work with IBM Spectrum Protect Snapshot: All DS8000 Releases >= R3.1 are supported. 1.1.2 For older DS8000 releases, the following minimum microcode levels are required: mcode 6.1.600.52/DSCLI 5.0.5.17, mcode 6.2.400.7x/DSCLI 5.2.400 or higher mcode 1.1.3 Support is provided for Fibre Channel attached volumes The user defined for IBM Spectrum Protect Snapshot operations in 1.1.4 DS8000 needs to be assigned to the "Administrator" user group. Copyright IBM Corp. 2001, 2017 3

1.2 Hardware Requirements for SVC / Storwize (SVC) IBM System Storage SAN Volume Controller versions 6.1, 6.2, 6.3, 6.4, 7.1, 7.2, 7.3, 7.4, 7.5, 7.6.0.2 and later 7.6.x levels, 7.7.0 and later 7.7.x levels, 7.8.0, 7.8.1 1.2.1 (Storwize) IBM Storwize V7000 v1 Disk System IBM Storwize V7000 Version 6.4, 7.1, 7.2, 7.3, 7.4, 7.5, 7.6.0.2 and later 7.6.x levels, 7.7.0 and later 7.7.x levels, 7.8.0, 7.8.1 IBM Storwize v3700 Version 6.4, 7.1, 7.2, 7.3,7.4, 7.5, 7.6.0.2 and later 7.6.x levels, 7.7.0 and later 7.7.x levels, 7.8.0, 7.8.1 IBM Storwize v5000 Version 7.1, 7.2, 7.3, 7.4, 7.5, 7.6.0.2 and later 7.6.x levels, 7.7.0 and later 7.7.x levels, 7.8.0, 7.8.1 IBM Storwize V7000 Unified v1.3 Disk System (block level support only) IBM Storwize V7000 Unified v1.4 Disk System (block level support only) IBM Storwize V7000 Unified v1.5 Disk System (block level support only) IBM Flex System v7000 Version 6.4, 7.1 and 7.2 IBM FlashSystem V840 IBM FlashSystem V9000 Version 7.4, 7.5, 7.6, 7.7.0 and later 7.7.x levels, 7.8.0, 7.8.1 Note: IBM Spectrum Protect Snapshot communicates with the SVC/Storwize only. There is no communication with the storage systems attached to the SVC. 1.2.2 Support is provided for Fibre Channel and iscsi attached volumes Support for Metro Mirroring and Global Mirroring: The target volumes of the Metro Mirror or Global Mirror relationships are usually located on a separate storage system at a secondary site. This can be the Disaster Recovery site, in Site Recovery Manager (SRM) terms it is called the recovery site. For remote site FlashCopy backups, IBM Spectrum 1.2.3 Protect Snapshot requires that the remote relationships are created, started, synchronized and added to a unique consistency group. For Global Mirror, IBM Spectrum Protect Snapshot relies on Global Mirror with Change Volumes in cycling mode with master and auxiliary change volumes. The use of this SVC / Storwize feature requires SVC / Storwize version 6.3 or higher. SVC and Storwize must be configured for https or http communication. By default, SVC/Storwize is configured for HTTPS communication. 1.2.4 Note: This does not apply when configuring the storage for dynamic target allocation (new type SVCDTA). In this case IBM Spectrum Protect Snapshot communicates with the storage-system via ssh. 1.2.5 For SVC and Storwize, the user defined for IBM Spectrum Protect Snapshot operations in SVC/Storwize needs to be assigned to the "Administrator" user group. 1.2.6 Use of dynamic target allocation (new type SVCDTA) requires SVC / Copyright IBM Corp. 2001, 2017 4

Storwize version 6.3 or higher. Note: Starting with SVC 6.1, the CIM agent can be restarted using the Service Assistant for 6.1.0 - http://clusterip/service go to the Restart Service navigation item and select the CIMOM. Copyright IBM Corp. 2001, 2017 5

1.3 Hardware Requirements for XIV IBM XIV Storage System Hardware: Supported system versions are 10.0.0.b or later 10.x levels, 11.x levels 1.3.1 IBM XIV Storage System Software: IBM XIV Management Tools 3.x for all IBM XIV Generations IBM XIV Management Tools 4.2.x for all IBM XIV Generations or XIV CLI 2.3.1 and later 2.x and 3.x levels for IBM XIV 2nd Generation XIV CLI 3.0.1 and later 3.x levels for IBM XIV 3nd Generation XIV CLI 4.2 and later 4.2.x levels for IBM XIV 3nd Generation XIV CLI 4.6 and later 4.6.x levels for IBM XIV 3nd Generation IBM Spectrum Accelerate : IBM Spectrum Accelerate Version 11.5.x IBM FlashSystem A9000 and A9000R: IBM FlashSystem A9000 and A9000R software version 12.0.1 and later 12.0.x levels. Before starting a Spectrum Protect Snapshot remote restore operation check the problem described in APAR IT16596 and the described local fix for it. 1.3.2 Support is provided for Fibre Channel and iscsi attached volumes Support for Synchronous and Asynchronous Mirroring: The target volumes of the remote mirror relationships are usually located on a separate storage system at a secondary site. This can be the Disaster Recovery site, in Site Recovery Manager (SRM) terms it is called the recovery site. For remote site Snapshot backups, IBM Spectrum Protect Snapshot requires that the remote relationships are created, started and added to a unique consistency group. For Synchronous Mirroring, the 1.3.3 relationships must be synchronized. For Asynchronous Mirroring the relationships must already be copied for the first time, otherwise a time out might occur while waiting for the copy process to complete. 1.3.4 Note: IBM Spectrum Protect Snapshot requires the usage of mirror consistency groups for synchronous and asynchronous remote mirroring on XIV. This feature is first implemented with XIV 10.2 The user account that will be used by IBM Spectrum Protect Snapshot to log onto the storage system must have Storage Administrator privileges 1.4 Hardware requirements for N Series/NetApp 1.4.1 Supported ONTAP versions are 7.3 or later 7.3.x levels Copyright IBM Corp. 2001, 2017 6

and 8.1 or later 8.1.x levels 1.4.2 Volumes must be attached over SAN, iscsi or NAS to the ESX hosts The user account that will be used by IBM Spectrum Protect Snapshot to log onto the storage system must have the permissions / capabilities: 1.4.3 api-system-*,api-volume*, login-http-admin, api-lun-list*, api-lun-get-serial-number, api-cg-start, api-cg-commit, and snapshot-list-info 2. Software Requirements The following software - if not otherwise specified - is required. 2.1 Software Requirements VMware A VMware vsphere environment consisting of: 2.1.1 VMware vcenter Server 5.0 or 5.1 VMware vcenter Server 5.5 VMware vcenter Server 6.0 and ESX hosts in the following versions: VMware ESX/ESXi 5.0 or 5.1 VMware ESX/ESXi 5.5 VMware ESX/ESXi 6.0 2.2 Software Requirements Linux On the Linux server for the IBM Spectrum Protect Snapshot for VMware installation: 2.2.1 Red Hat Enterprise Linux 7 x64, and later maintenance levels and mod levels: Server Edition Red Hat Enterprise Linux 6 x64, and later maintenance levels and mod levels: Server Edition Red Hat Enterprise Linux 5 x64 Version 5.6, and later maintenance levels and mod levels: Desktop, Advanced Platform, and Server Edition SUSE Enterprise Linux 11 x64, and later mod levels and Fix Packs: Server Edition SUSE Enterprise Linux 12 x64: Server Edition Copyright IBM Corp. 2001, 2017 7

Copyright IBM Corp. 2001, 2017 8

2.3 Software Requirements - Storage Subsystems XIV 2.3.1 IBM XIV Management Tools 3.x for all IBM XIV Generations IBM XIV Management Tools 4.2.x for all IBM XIV Generations or XIV CLI 2.3.1 and later 2.x and 3.x levels for IBM XIV 2nd Generation XIV CLI 3.0.1 and later 3.x levels for IBM XIV 3rd Generation XIV CLI 4.2 and later 4.2.x levels for IBM XIV 3rd Generation XIV CLI 4.6 and later 4.6.x levels for IBM XIV 3rd Generation SVC / Storwize V7000 2.3.2 When dynamic target allocation is used (new type SVCDTA), OpenSSH needs to be installed on the Linux server (1.0.2) where IBM Spectrum Protect Snapshot for VMware is installed. In addition, a public/private key pair is required for accessing the SVC CLI via ssh. The public key needs to be imported on the storage device while the private key needs to be imported on the Linux server. See the User's Manual for more details (chapter Configuring to use the Storwize family and SAN Volume Controller with dynamic target allocation (SVCDTA). Copyright IBM Corp. 2001, 2017 9

3. Environmental Requirements (general) 3.0.1 3.0.2 3.0.3 3.0.4 3.0.5 3.0.6 The ulimits of the tdpvmware user on the Linux server (1.0.2) should at a minimum be set to (check with ulimit -a): data seg size (kbytes) unlimited max memory size (kbytes) 131000 stack size (kbytes) 131000 Depending on the user's shell and OS level, the output of the command ulimit -a can vary. Port 9081 of the Linux server (1.0.2) needs to be accessible from all hosts that use vsphere clients to access the Web GUI (stand-alone and/or plugin) delivered with IBM Spectrum Protect Snapshot for VMware. Internet explorer security settings on all hosts that use vsphere clients to access the GUI plugin delivered with IBM Spectrum Protect Snapshot for VMware need to permit access to the Linux server (1.0.2). The following characters are allowed in data center, datastore and virtual machine names: [A-Z][a-z][0-9]${}=~ :#!&+-._(),; and whitespace When naming datastores that are going to be backed up, the name length cannot exceed 31 characters. When the snapshot of the datastore is created, an 11-character identifier is appended to the datastore name. VMware requires datastore names do not exceed 42 characters. In order to use IBM Spectrum Protect Snapshot for VMware to back up and recover virtual machines, you must authenticate to the VMware vcenter server with a user ID which has a role that has sufficient privileges to perform these operations. Please refer to the chapter VMware vcenter Server user privilege requirements of the Installation and User's Guide for a detailed list of the required privileges. Copyright IBM Corp. 2001, 2017 10

Trademarks The following terms are trademarks or registered trademarks of IBM corporation in the United States, other countries, or both: DS8000, XIV, SVC, IBM Storwize V7000, IBM N series, FlashCopy, IBM, Passport Advantage, Tivoli, TotalStorage, Spectrum Protect. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. VMware vcenter, ESX, ESXi, VMware vsphere are trademarks or registered trademarks of VMware, Inc. in the United States and/or other jurisdictions Other company, product and service names may be trademarks or service marks of others. Copyright IBM Corp. 2001, 2017 11