SCP for Plastics Processing

Similar documents
DAQ-System for DynoWare

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

ComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A...

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

ComoNeo. Electronics & software. System for process monitoring and process optimization in plastic injection molding applications. Type 5887A...

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Pressure Measurement, Application The Multi Sensor Set is designed for industrial use in multicavity molds. The multi-channel connectors Type

high performance signal conditioner cards

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Advanced NI-DAQmx Programming Techniques with LabVIEW

Isolated Process Current Input with Loop Power 7B35

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

GFK-2415A March Type of sensor connection

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

MODEL 9250 Preliminary data sheet

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T

GSV-2MSD-DI DMS-Data Logger

User Manual CTP64-Rotate

Blade & Vibration Monitor Model Hood Technology Corporation 30 August 2009 Blade & Vibration Monitor Model Overview

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Distance and Position Sensors

Temperature Switches

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

EMX Data Acquisition Devices

AXL E IOL AO1 U M12 R

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Acquisition and Evaluation, 2825A... TEL: Measuring Instrument Control and Configuration via Communication Interfaces RS-232C 501

Signal Conditioning Modules and Terminal Boards

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

C100 Portable Multifunction

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

TM221CE24R controller M IO relay Ethernet

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

4-component Dynamometer (RCD)

Linear Position Transducer HLT 1000-R2

TM221M16R controller M IO relay

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

SYSTEMS ELECTRONICS GROUP

BSL Hardware Guide for MP35 and MP30-1 -

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Electronic Level Switch ENS 3000

Expanding the Basic GL7000 Configuration

Data sheet CPU 115 (115-6BL02)

MID approval no. DE-08-MI004-PTB004 Date of release

BP16 Backplane for MAL Amplifiers

GSV-1A4 M12/2 M12/2. Highlights

Suitable for detecting transparent films or transparent bottles

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Linear Position Transducer HLT 1000-R2

USB-1602HS-2AO Specifications

Preface About this User's Guide... iv What you will learn from this user's guide... iv Conventions in this user's guide... iv

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

E Series Multifunction I/O 1.25 MS/s, 12-Bit, 16 or 64 Analog Inputs

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

ControlMonitor CoMo View

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

ControlMonitor CoMo Net

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Expandable Modular Data Acquisition System inet-400 Series

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

OPERATION MANUAL - DS-MOD-

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Specifications

Features. RoHS COMPLIANT 2002/95/EC

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

14 Bit rsp. 16 Bit. 80 MS/s 40 MS/s 20 MS/s 10 MS/s

Temperature Measurement

TraNET FE Data Acquisition Instrument

Model 3724 Dual 1x30 FET Multiplexer Card

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

TM221CE40T controller M IO transistor PNP Ethernet

KeConnect I/O modules

Digital Indicator Solutions

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Voice Alarm System VX-3000 Series

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Compact Inductive Proximity Sensor

TM221CE40R controller M IO relay Ethernet

SENSORS INCLINOMETERS... SN4 LENGTH AND ANGLE SENSORS... SN6 SLIP-IN SPOOL POSITION TRANSDUCER... SN8 PROXIMITY SENSOR... SN10 MATERIAL SENSOR...

Transcription:

Measure & Analyze MCS SCP for Plastics Processing Modules for Signal Conditioning System Type 2853A..., 2207A..., 5063A..., 5227A..., 5613A... The SCP is a modular system for conditioning measuring signals from piezoelectric, piezoresistive and thermocouple sensors. Voltages from external sources can also be measured in addition. The SCP consist of a base unit and application specific module. Maximum flexibility for applications in plastic processing Fully supported by DataFlow Software Description The SCP modules are modules for the SCP base unit Type 2853A and signal conditioner Type 2859A. These are described in detail in the data sheets of the corresponding Types. The SCP base unit is a stationary system which can be equipped with up to 8 modules. Up to 32 input channels are available. The signal conditioner Type 2859A is the mobile version of this system. 4 piezoelectric pressure inputs and 4 temperature inputs are integrated in this system as standard. A vacant module slot allows the system to be expanded as required by up to 12 input channels. SCP «Plastics Processing» in typical configurations The following modules are available for plastics processing: 4-channel thermocouple amplifier Type 2207A 4-channel charge amplifier Type 5063A1 for the connection of 4 piezoelectric sensors 4-channel voltage amplifier Type 5227A1 for the connection of 4 external «voltage sources» ±10 V 4-channel amplifier interface Type 5613A1/A2 for the supply, remote control and signal transmission from 4 external amplifiers or transmitters. The module provides an excitation voltage of 24 V and ±15 V respectively for the external amplifiers Type 2207A Type 5063A1 Application When used with the DataFlow software Type 2805A-02-x, the SCP Type 2853A... and the signal conditioner Type 2859A... is suitable for process visualization, process monitoring and process documentation for all variations of the injection molding process and other cyclical processing methods. For further information on DataFlow, see corresponding data sheet. Type 5227A1 Type 5613A1/A2 Page 1/6

Valid for all Modules Operating temperature range C 0... 60 Min./Max. temperature C -10/60 Vibration resistance (20... 2000 Hz, gp 10 duration 16 min, cycle 2 min) Shock resistance (1 ms) g 200 Sound resistance dba 120 Front panel dimensions mm 128,7 x 35,0 HE - 3 TE - 7 The module outputs are available on the interface card Type 5225A1. This interface card is described in data sheet of Type 2853A.... 4-Channel Thermocouple Amplifier Type 2207A Temperature amplifier for the connection of up to 4 thermocouples or temperature sensors Types K and J. The amplifier is equipped with differential amplifier and cold spot compensation. Thermocouple Type J or K Measuring range I C 0... 400 Measuring range II C 0... 200 Error measuring range I % <0,5 Error measuring range II % <0,2 Zero point error mv <10 mv Frequency range (-3dB) khz 0... >1 Probe interrupt detection V -9... -10,5 (neg. saturation) Output voltage V 0... 10 Output current ma 0... 2 Output interference signal (0,1... 1 MHz) mv pp <10 Thermocouple connection Type Phoenix screw terminals Weight kg 0,28 Page 2/6

4-Channel Charge Amplifier Type 5063A1 The charge amplifier for piezoelectric sensors is equipped with differential inputs and a common ground. All amplifiers have a common Operate. 4-Channel Voltage Amplifier Type 5227A1 Voltage amplifier for the connection of up to 4 «voltage sources» with ±10V. The settings required are made using the software. Measuring range I pc ±5 000... ±50 000 Measuring range I on delivery pc ±20 000 calibrated to Measuring range I/II ratio 4 Error % <±1 Drift (0... 50 C) pc/s <±0,2 (25 C) pc/s <±0,05 Frequency range (20 V pp) khz 0... >25 Reset/Operate transition pc <±2 Signal polarity negative input charge results in pos. output voltage Max. voltage between V <±50 sensor GND and output/ supply voltage Suppression of the interference db >70 signals between sensor GND and output/supply GND Output voltage V 0... ±10 Output current ma 0... ±2 Output interference signal mv pp <10 (0,1 Hz... 10 MHz) Sensor connections Type BNC neg. Weight kg 0,26 Measuring range V ±10 Selectabel gain 1 / 2 / 5 / 10 Error % <±0,5 Zero point error mv <±10 with gain 10 mv <±20 Frequency range (20 V pp) -3dB khz 0... >50-5% khz 0... >30 Max. voltage between sensor GND and output/ V <±50 supply voltage Suppression of the interference db >70 signals between sensor GND and output/supply GND Input resistance MΩ >10 Output voltage V 0... ±10 Output current ma 0... ±2 Output interference signal mv pp <10 (0,1 Hz... 10 MHz) Sensor connections Type BNC neg. Weight kg 0,21 Page 3/6

4-Channel Amplifier Interface Type 5613A1/A2 Amplifier interface for connection of up to 4 external amplifiers or transmitters. The module provides a excitation voltage for the external amplifiers of 24 V (5613A1) or ±15 V (5613A2) respectively as well as Operate and Range signals (for all channels active simultaneously). Type Type 5613A1 5613A2 Measuring range V ±10 Gain 1 Error % <±0,1 Zero point error mv <±2 Frequency range (20V pp) khz 0... >50 Input resistance kω >300 Output voltage V 0... ±10 Output current ma 0... ±2 Output interference signal mv pp <10 (0,1 Hz... 10 MHz) Power supply for external amplifier (electrically isolated) Voltage VDC 24 ±15 Current consumption ma <45 <±30 per channel Sensor connections Type Sub D 9 female Weight kg 0,16 Pin Allocation Sub D 9-pole Pin Allocation: 1 (-15 V) 2 +24 V (+15 V) 3 +RANGE II 4 +OPERATE 5 Signal Input 6 Power GND 7 -RANGE II 8 -OPERATE 9 Signal GND Pin allocation Type 5613A Operate, Range and excitation voltage for external Amplifier. Page 4/6

Ordering Code Signal Conditioning Platform Type 2853A When ordering, please use the form below. Place a cross next to the chassis Type (Chassis Rack or Desktop) as well as the modules required and their positions in the module slots (see data sheet SCP chassis). Chassis Rack (19 ) Type 2853A11 Desktop Type 2853A12 Interfaces (these SCP modules must be included in the order) ç 5615 CPU interface ç 5225A1 Analog interface Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Type 2207A 4-channel temperature amplifier 5063A1 4-channel charge amplifier 5227A1 4-channel voltage amplifier 5613A1 4-channel amplifier interface 5613A2 4-channel amplifier interface 5700A09 Dummy plate open Order form: Please place a cross against the allocation of each slot Accessories Included Type/Art. No. Software on CD 7.643.014 CPU interface card 5615 Analog interface card 5225A1 Optional Accessories Type/ Art. No. DataFlow software for process visualization 2805A-02-1 for Windows 95c, Windows 98SE, NT, 2000, XP with license code on parallel port. DataFlow software for process visualization 2805A-02-2 for Windows 95c, Windows 98SE, NT, 2000, XP with license code on USB port A/D card 16-channel PC card 2855B1 A/D card 16-channel PC card 2855A5 A/D card 16-channel PCI card 2855A4 A/D card 64-channel PCI card 2855A6 A/D card 16-channel ISA card 2855A3 A/D card 32-channel ISA card 2855A2 Connecting cable from A/D card Type 2855B1 1200B21 Connecting cable from A/D card Type 2855A5 1200B21 Connecting cable from A/D card Type 2855A4 1200A13 Connecting cable from A/D card Type 2855A6 1200A41 Connecting cable from A/D card Type 2855A3 1200A13 Connecting cable from A/D card Type 2855A2 1200A41 Communication cable, serial 5 m 1200A27 Grounding cable 5.590.175 Connecting cable from charge amplifier 1200A5 Type 5039A... to amplifier interface Type 5613A1 Connecting cable from hydraulic pressure 1200A39 transmitter Type 4095A... (4... 20 ma) Connecting cable from SmartAmp Type 5049A 1200A9 Page 5/6

Connecting cable from charge amplifier 1200A7 Type 5011 Connecting cable from hydraulic pressure 1200A11 transmitter Type 4095A... (0... 10 V) Connecting cable from piezoresistive 1200A29 amplifier Type 4618A0 and 4618A2 Connecting cable from temperature amplifier 1200A25 Type 2809A1 for connection to Interface Type 5613A1 Connecting cable from extrusion sensor 1200A33 Type 4096/97 (0 10 V) to amplifier interface Type 5613A1 Connecting cable from digital amplifier 1200A35 Type 4620A1 to amplifier interface Type 5613A1 Connecting cable from extrusion sensor 1200A37 Type 4096/97 (4 20 ma) to amplifier interface Type 5613A1 Connecting cable to interface card Type 5615 1200A15 for digital inputs and outputs Inductive proximity switch for 2231 Operate signal; connection to interface card Type 5615 Typical configurations with DataFlow software for process visualization,. These components must be ordered in addition for the SCP chassis and for the SCP modules. Version I: Connection to Laptop (16 Channels) Type DataFlow software for process visualization, 2805A-02-2 with license code on USB port A/D card 16-channel PC card 2855B1 Communication cable, serial 5 m 1200A27 Connecting cable from A/D card 1200B21 Type 2855B1 Inductive proximity switch for 2231 for Operate and Trigger signals; connection to interface card Type 5615 Version II: Connection to Standard PC (16 Channels) DataFlow software for process visualization, 2805A-02-1 with license code on parallel port A/D card 16-channel PCI card 2855A4 Connecting cable from A/D card 1200A13 Type 2855B1 Communication cable, serial 5 m 1200A27 Inductive proximity switch for 2231 Operate signal; connection to interface card Type 5615 Page 6/6