Installing the Enphase IQ Commercial Envoy

Similar documents
Installing the Enphase Envoy-S Metered

INSTALLATION AND OPERATION MANUAL. Enphase IQ Envoy , Rev 01

Installing the Enphase IQ Combiner+

Installing the Enphase IQ Combiner+

INSTALLATION AND OPERATION MANUAL. Enphase Envoy-S , Rev 02

Enphase AC Combiner Box with Envoy-S

M215 (M215-60) Safety

M250 (M LL) Safety

M215-Z Safety Information (M LL-IG-ZC)

Installation/User Manual

Enphase S-Series Microinverter and Engage Cable Safety

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

Installation/User Manual

+Cam Quick Start Guide

User Manual. Smart Dimmer Switch. Part 1: General Specification Main Features... 2

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Quick Start Guide.

Installation/User Manual

Wireless Area Controller (WAC60)

EAGLE-200. Intelligent Control Gateway. User Manual

System Design Guide. APsystems YC Photovoltaic 3-Phase Grid-connected Microinverter. APsystems. Version 1.1 3/15

PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Square D Clipsal Pascal Automation Controller

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Installation / User Manual

W10 PRO QUICK START GUIDE

Home Security Camera icamera-1000

Wa r n i n g-wa r n i n g-wa r n i n g

Enphase C250 Microinverter System

FCC Regulatory Information

DOWNLOAD PDF ENPHASE M250 INSTALLATION GUIDE

PRO-HC IRRIGATION CONTROLLER

INSTALLATION INSTRUCTIONS

User Guide. DOCSIS 3.0 High Speed Cable Modem TC7650 REV

Quick Start Guide. Reolink Argus 2. Technical Support QG2_A. For more troubleshooting, please go to FAQs on our website:

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

BCM2 Series Branch Circuit Monitors Quick Setup Guide

4MP WI-FI PAN TILT CAMERA QUICK START GUIDE ENGLISH

1. Product Description. 2. Product Overview

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

DDW36A Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Wireless Area Controller (WAC50) i. Installation Instructions

USER GUIDE. Smart Wi-Fi LED Bulb (2700K and 5000K) Model: W11-N11

H560N. Quick Start Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Installing Enphase IQ 6 and IQ 6+ Microinverters

Quick Start Guide. Powerline Wireless Extender GPLWE150 PART NO. Q1337.

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

MXHP-H500 (Hub) Owner s Manual v.1.0

InnoMedia ipbx-400. Quick Install Guide.

elise 3 embedded linux server including safety instructions

Installing Enphase IQ 6 and IQ 6+ Microinverters

PILOT QUICK START GUIDE

HD40H(X) Performance Series Camera. User Guide

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

BW50 SportBuds. User Guide. Control Buttons & Operations. On / Off. Play / Pause / Answer. Volume / Track Selection. Models: GDI-EXBW50...

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

PowerView. Hub QUICK START GUIDE

CTS-iCPE Gateway Controller User s Manual Version: Revision B1

Introduction. See page #6 for device requirements.

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS IN WALL SOLUTIONS

Wireless 11n Smart Repeater AP (1T1R)

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

LPWWS Smart Wi-Fi Wall Station

Installing Enphase M250 and M215 Microinverters

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1.

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

1. Product description

PV Rapid Shutdown device

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

HPC RETROFIT FACE PANEL FOR PRO-C CONTROLLERS. Hydrawise Ready. Quick Start Guide. hunterindustries.com

NEW ERA METER. Installation & Operation Guide NE METER

AC2600 WiFi Gigabit Router Quick Start. Model MR2600

M-Series Enphase Microinverter

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

Enphase Microinverter

Quick Installation Guide

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Cube Camera with Fixed Lens Hardware Manual D11, D12. Ver. 2013/05/17

Disclaimers. Important Notice

ZIPATILE. Quick Start Guide v.1.1

Please read this safety information carefully and keep this user manual for later reference.

FCC CAUTION SETTING... 9

Lyric C1 Wi-Fi Security Camera

Streaming Smart Stick. Quick Start Guide

Satellite INSTALLATION GUIDE

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Documentation on all Paxton products can be found on our web site -

INSTALLATION INSTRUCTIONS

SEM3 - Embedded Micro Metering Module

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

CHANGE THE DEFAULT PASSWORD

Transcription:

QUICK INSTALL GUIDE (Model ENV-IQ-AM3-3P) Installing the Enphase IQ Commercial Envoy To install the Enphase IQ Commercial Envoy, read and follow all warnings and instructions in this Guide and in the Enphase IQ Commercial Envoy Installation and Operation Manual at: enphase.com/support. Safety warnings are listed on the back of this guide. IMPORTANT: Enphase IQ Commercial Envoy, IQ Envoy, and IQ Series Micros do not communicate with, and should not be used with, previous generation Enphase Microinverters and Envoys. Always use IQ Series Microinverters with an IQ Commercial Envoy or an IQ Envoy. How It Works IQ Microinverters Load center IQ Envoy Router Enphase Enlighten To Internet PREPARATION A ) Download the Enphase Installer Toolkit mobile app and open it to log in to your Enlighten account. With this app, you can connect to the IQ Commercial Envoy to track system installation progress. To download, go to enphase.com/toolkit or scan the QR code at right. B ) Download the latest version of the software to your mobile device. To do so, go to the Envoy Resources screen in the Installer Toolkit Settings. C ) Check the box for the following items: Enphase IQ Commercial Envoy (look for the IQ logo) Three solid-core production metering current transformers (CTs) Length of DIN rail for mounting Enphase IQ Commercial Envoy Quick Install Guide (this document) D ) If you plan to do consumption metering, make sure you have three splitcore consumption metering CTs (order CT-200-SPLIT). POWER LINE COMMUNICATIONS NETWORK COMMUNICATIONS Note: The consumption CTs monitor up to 200A of consumption current and fit conductors with a maximum outside diameter of 0.84 (21.33mm). You can use up to two parallel connected consumption CTs for monitoring up to two conductors. For conductors or bussing greater than 200A, the consumption CTs shall not be installed or enabled. IQ Commercial Envoy Display and Controls Track system installation progress with the Enphase Installer Toolkit mobile app. The LEDs on the IQ Commercial Envoy are solid green when a function is enabled or performing as expected, flashing when an operation is in progress, or solid amber when troubleshooting with Installer Toolkit is required. For a legend of all LED states, see Troubleshooting a. Network Communications LED Green when IQ Commercial Envoy is connected to Enlighten. AP Mode LED Green when Envoy s AP Wi-Fi network is available. AP Mode Button Press to enable Envoy s AP Mode for connecting with a mobile device. Hold for 5 seconds to start WPS connection to a router. Power Production LED Green when microinverters are producing power. Device Communications LED Green when devices are communicating with IQ Commercial Envoy. Device Scan Button Press to start/stop 15 minute scan for devices over the power line. Enphase Installer Toolkit mobile app E ) Check that there is enough space in the load center to install CTs. Do not install CTs where they exceed 75% of the wiring space of any cross-sectional area within the load center. F ) Install the IQ Commercial Envoy in a NRTL Certified, NEMA type 3R (or better) enclosure with conduit attachment when installing outdoors. Do not drill holes on the top of the enclosure or anywhere that allows moisture ingress. Metallic enclosures may impair Wi-Fi signal strength. Use an appropriately rated enclosure if installing indoors. G ) Decide how to connect the IQ Commercial Envoy to the Internet: Use Wi-Fi, an Enphase Mobile Connect modem, or Ethernet. Then, make sure you have the following optional items, if needed: Enphase Mobile Connect modem [order CELLMODEM-01 (3G) or CELLMODEM-03 (4G)] Ethernet over power line communication (PLC) bridge with Ethernet cables (order EPLC-01). You must use a ferrite bead on the Ethernet cable (we recommend Fair-Rite 0431167281). Ethernet cable [802.3, Cat5E or Cat6, unshielded twisted pair (UTP)]. Do not use shielded twisted pair (STP) cable. You must use a ferrite bead on the Ethernet cable (we recommend Fair-Rite 0431167281). H ) Create a paper installation map to record device serial numbers and positions in the array. You will scan this map later using Installer Toolkit and your mobile device. As you do with the microinverters, peel the removable label from the bottom of the IQ Commercial Envoy and affix it to the paper installation map. Always keep a copy of the installation map for your records. Note: If needed, you can find an installation map at the back of the Enphase IQ Microinverter Quick Install Guide. I ) Note that installation of the IQ Commercial Envoy has two parts. To ensure successful device detection, complete Part 2 after installing any Enphase IQ Microinverters.

INSTALLATION Part 1 It is a best practice to complete Installation Part 1 before installing Enphase Microinverters. For steps 2 and 3, refer to the wiring diagram on the next page. 1 2 Choose a location for the IQ Commercial Envoy WARNING: Risk of equipment damage. When installing the IQ Envoy in an enclosure, choose area for installation where ambient temperature does not exceed 46º C (115º F). A ) Install the IQ Commercial Envoy near the main load center or PCC (point of common coupling) and consider the length of the production CT leads (5 feet) when choosing the location. Do not extend the leads of the production CTs. B ) Install the IQ Commercial Envoy in a protected dry space in an NRTL Certified, NEMA type 3R (or better) enclosure with conduit attachment. Use an appropriately rated enclosure if hard wiring the IQ Commercial Envoy indoors. Metallic enclosures may impair Wi-Fi signal strength. C ) Mount the Envoy horizontally using the included DIN rail. Wire the IQ Commercial Envoy for Power and Metering The IQ Envoy uses terminal blocks for power and metering connections. Refer to the wiring digram on the following page when performing this step. You must install three solid-core current transformers (CTs) for production metering. Consumption monitoring is optional and requires that you order and install three additional split-core CTs. Use a protected route in conduit for the CT wires from the main load center to the IQ Commercial Envoy. The consumption CT leads are 13 feet long. If you need to extend the leads, refer to the Enphase IQ Commercial Envoy Installation and Operation Manual at: enphase.com/support. Do not extend the leads of the production CT. DANGER! Risk of electric shock. Always de-energize circuits before wiring for power and CTs. DANGER! Risk of electrocution! Do not install CTs when current is flowing in the sensed circuit. Always install CT wires in the terminal blocks before energizing the sensed circuit. Note: When installing CTs, it is important to match CT and sense voltage phases. Be sure to consistently identify the three AC lines at three points: the main load center feed, the Envoy, and the solar production circuit breaker. Wire colors (typically black, red, and blue) may not always consistently identify L1, L2, and L3. If in doubt, use a multimeter to check. Note: Because of variance in load center design and main power feed, there may not always be enough space to install consumption metering CTs. See our technical brief, Assessing a Site for Installing Consumption CTs, at enphase.com/support. A) Before running the CT wires through conduit, use colored tape to mark each of the CTs and the free ends of its wires, marking each with a different color. You can run multiple CT wires through a single conduit. B ) Wire the IQ Commercial Envoy for power Use a three-pole circuit breaker of up to 20 A (maximum) for the supply wiring. Make sure supply wiring is 14 AWG or larger copper rated at 75 degrees C or better. Use a screwdriver to loosen the screw on the terminal block door and open the door. Flip open the terminal block door and wire the line and neutral conductors as shown: Connect Line 1 to L1, Line 2 to L2, Line 3 to L3, and Neutral to N. Tighten to 10.5 in-lbs (1.2 N m). C ) Install the production CTs on active phases as required: Locate the arrow on the CT label. To monitor production on Line 1: - Connect the white wire to the white P1 terminal and the blue wire to the blue P1 terminal. - Pass Line 1 of the solar production circuit through the CT with the arrow pointing toward the load (away from the solar array). To monitor production on Line 2: - Connect the white wire to the white P2 terminal and the blue wire to the blue P2 terminal. - Pass Line 2 of the solar production circuit through the CT with the arrow pointing toward the load (away from the solar array). To monitor production on Line 3: - Connect the white wire to the white P3 terminal and the blue wire to the blue P3 terminal. - Pass Line 3 of the solar production circuit through the CT with the arrow pointing toward the load (away from the solar array). Tighten all connections to 5 in-lbs (0.6 N m). D ) Install the consumption CTs on active phases as required: Locate the arrow on the CT label. Make sure that the AC mains wire(s) are de-energized until you have secured the CT wires in the terminal blocks. To monitor consumption on Line 1: - Connect the white wire to the white C1 and the blue wire to the blue C1 terminal. - Clamp the CT on the main supply Line 1. When the consumption CT is on Line 1 conductor, the arrow must point toward the load (away from the grid). To monitor consumption on Line 2: - Connect the white wire to the white C2 terminal and the blue wire to the blue C2 terminal. - Clamp the CT on the main supply Line 2. When the consumption CT is on Line 2 conductor, the arrow must point toward the load (away from the grid). To monitor consumption on Line 3: - Connect the white wire to the white C3 terminal and the blue wire to the blue C3 terminal. - Clamp the CT on the main supply Line 3. When the consumption CT is on Line 3 conductor, the arrow must point toward the load (away from the grid). Tighten all connections to 5 in-lbs (0.6 N m). 3 Note: Only run active conductors of the same phase through each CT. Each CT can monitor multiple active conductors. Energize and Update the IQ Commercial Envoy A ) Close the terminal block door, and secure it with the screw. B ) Turn on the circuit feeding the IQ Commercial Envoy. C ) On the Envoy, if the AP Mode LED is not lit, press the AP Mode button. D ) On your mobile device, go to Settings and join the Wi-Fi network Envoy_nnnnnn (where nnnnnn represents the final six digits of the IQ Commercial Envoy serial number). E ) The Installer Toolkit app informs you if the Envoy software is not current by displaying the Envoy Software Update message. If this message displays, follow the on-screen instructions to update the Envoy. F ) For a short period (5-10 minutes), you must keep your mobile device near the Envoy. Follow the on-screen instructions while the update takes place. The update may take up to 20 minutes. The Envoy reboots several times during the update and the LEDs light up in varied sequences until the update is complete. WARNING: Do not remove power from the IQ Commercial Envoy during the software update. All four LEDs flash amber during boot up (approximately 3 minutes). When boot up is complete, the Device Communications LED lights solid amber, indicating that devices are not yet detected.

To Solar Subpanel Load Center Production CT. Solid Core. The arrow must point toward the load away from the solar array. Consumption CT. Split Core. The arrows must point toward the load away from the griid. To Grid IQ Envoy Terminal Block Not used Relay contacts (if needed) L2: White L2: Blue N: White L1: Black L2: Red L3: Blue L1: White L1: Blue L2: White L2: Blue L3: White L3: Blue L1: White L1: Blue L3: White L3: Blue IQ COMMERCIAL ENVOY WIRING CU, 75C, 14AWG MIN MEAS CAT III OVC III Production Consumption P1 P2 P3 C1 C2 C3 N L1 L2 L3 Production Consumption PD, B300 OVC II Digital Input Relay 1 2 3 4 NO Ref Common C

INSTALLATION Part 2 Once the update is finished and the PV system is installed, the Envoy is ready for Installation Part 2. You must complete Installation Part 2 after installing the PV system. 4 Detect Devices Use one of the following methods to detect devices (Enphase Microinverters). Method A // Provision devices with Installer Toolkit Use the Installer Toolkit mobile app to configure the IQ Commercial Envoy with the serial numbers of the installed devices. A ) Launch the Installer Toolkit app and tap View Systems. B ) Select the system you are working with, or tap [] to add a new system. C ) Connect to the IQ Commercial Envoy with your mobile device (smart phone or tablet) to the IQ Commercial Envoy. The AP Mode LED lights solid green when the network is available. On the Envoy, if the AP Mode LED is not lit, press the AP Mode button. On your mobile device, go to Settings and join the Wi-Fi network Envoy_nnnnnn (where nnnnnn represents the final six digits of the IQ Commercial Envoy serial number). D ) If the serial number for the Envoy you are installing is not displayed on the System Overview screen, tap the [] next to the word Envoys. When the app displays the serial number of the Envoy, tap it to add it to the system. E ) Following the on-screen instructions to create the arrays and scan the serial numbers from the installation map. F ) Tap the Connect button. This provisions the scanned devices on the Envoy. G ) When prompted, confirm the number of devices that you installed. H ) If your system requires a region-specific grid profile, select and apply a grid profile to the devices. (Systems in Hawaii require you to set a profile.) The Device Communications LED lights solid green if all the provisioned devices are communicating or solid amber if any devices are not communicating. Method B // Discover devices with Installer Toolkit Use the Installer Toolkit mobile app to set the number of devices the IQ Commercial Envoy should search for on the power line. A ) Connect to the IQ Commercial Envoy with your mobile device (smart phone or tablet) to the IQ Commercial Envoy. The AP Mode LED lights solid green when the network is available. On the Envoy, if the AP Mode LED is not lit, press the AP Mode button. On your mobile device, go to Settings and join the Wi-Fi network Envoy_nnnnnn (where nnnnnn represents the final six digits of the IQ Commercial Envoy serial number). B ) Launch Installer Toolkit and tap Connect to an Envoy. C ) When prompted, enter the number of devices that you installed. D ) If your system requires a region-specific grid profile, select and apply a grid profile to the devices. (Systems in Hawaii require you to set a profile.) E ) When prompted to start a device scan, tap OK. The Device Communications LED flashes green while scanning, solid green when all the devices you installed are communicating, or solid amber if any devices are not communicating. 5 Verify Configuration and Enable the Meters While still connected to the IQ Commercial Envoy with Installer Toolkit, check the Overview screen for the following: A ) Confirm that the expected number of devices are detected and communicating. B ) Check that the new profile is set on all the devices. Setting the profile may take up to 5 minutes for a typical system. C ) Tap the Meters button. D ) Tap Production Meter and follow the on-screen instructions to enable the Production Meter. E ) If you installed consumption metering CT(s), tap Consumption Meter and follow the on-screen instructions to enable the Consumption Meter. F ) Return to the Overview screen and verify the meter reading(s). If you used Installer Toolkit to detect devices, the Power Production LED lights solid green when all expected microinverters are producing power. If you did not use Installer Toolkit, it lights solid green if all communicating microinverters are producing power. It flashes green when devices are upgrading. Check Installer Toolkit for production status details. If the Power Production LED remains solid amber, see Troubleshooting c. 6 Connect to Enlighten This section describes using the IQ Commercial Envoy integrated Wi-Fi or the Mobile Connect modem. For information about using Ethernet and/ or PLC bridges, refer to the Enphase IQ Commercial Envoy Installation and Operation Manual at: enphase.com/support. Method A // Integrated Wi-Fi Requires a wireless router with an Internet connection. A ) On the Envoy, verify that no Ethernet cable is plugged into the RJ45 port. B ) If the router supports WPS, press and hold the WPS button on the wireless router for a few seconds. On most routers, a WPS indicator begins flashing. C ) If you are using the Installer Toolkit mobile app, tap the Network button, tap Wi-Fi, and then tap your network from the list of available networks. If the wireless router does not support WPS, you may be prompted to enter a password. The Network Communications LED begins flashing green. Within three minutes the Network Communications LED lights solid green, indicating a successful connection to Enlighten. If the IQ Commercial Envoy Network Communications LED remains off or lights solid amber, see Troubleshooting d. Method B // Enphase Mobile Connect Modem [Order CELLMODEM-01 (3G) or CELLMODEM-03 (4G) separately] A ) Connect the antenna(s) to the connector(s) and mount the modem as described in the Enphase Mobile Connect Installation Guide. B ) First, connect the USB cable to the IQ Commercial Envoy and then connect the mini-usb connector to the modem. If receiving power from the IQ Commercial Envoy, the modem power LED lights. Within three minutes the Network Communications LED lights solid green, indicating a successful connection to Enlighten. If the Network Communications LED remains off or lights solid amber, see Troubleshooting in the Enphase Mobile Connect Installation Guide. wireless router IQ Commercial Envoy Enphase Mobile Connect modem With both methods If the Device Communications LED remains solid amber, see Troubleshooting b.

7 Send System Summary Report When you have completed your system setup, you can generate and email a summary report. A ) From Installer Toolkit, tap Done in the upper-right corner of the screen to disconnect from the Envoy. Installer Toolkit will ask if you want to view a summary report. B ) Tap View Report. The report displays IQ Envoy and system information with a list of device serial numbers, their last power reports, and information about the grid profile applied to the devices. C ) Tap to email the report as needed as a record of successful system installation and for evidence of grid profile settings. 8 Activate Monitoring Register the IQ Envoy in Enlighten (enlighten.enphaseenergy.com). Method A // If the IQ Envoy is associated with a system in Installer Toolkit A ) On your mobile device, go to Settings and disconnect from the Envoy s Wi-Fi network. B ) Return to the Installer Toolkit app and tap the Sync button on the System Overview screen. C ) When you have access to a computer with Internet access, log in to Enlighten and select the system name from the Activation List on the dashboard. D ) From the activation form, open Array Builder. If you used Installer Toolkit to build arrays and scan device serial numbers, the array(s) are built make any necessary adjustments in Array Builder. If you did NOT use Installer Toolkit to build arrays and scan device serial numbers, create the virtual array in Array Builder using the installation map as your reference. (You may need to wait if the devices have not yet reported to Enlighten.) Method B // If the IQ Commercial Envoy is NOT associated with a system in Installer Toolkit A ) Log into Enlighten and click Add a New System from the dashboard. B ) Enter the System, Installer, Owner, and Location information. C ) Enter the IQ Commercial Envoy serial number. D ) Click Save to submit the form. E ) After the devices have reported to Enlighten, open Array Builder from the activation form, and create the virtual array, using the installation map as your reference. TROUBLESHOOTING a LED overview LED State Description All Flashing amber in unison The IQ Commercial Envoy is booting up Flashing green sequentially Software upgrade in progress Solid green Flashing green Network communications Solid amber Solid green AP mode Power production Solid green Flashing green Solid Amber Solid Green Flashing Green Device Solid Amber communications b Device detection issues Communicating with Enlighten WPS connection in progress or the IQ Envoy is attempting to connect to Enlighten Local network connection only No network connection AP mode enabled: IQ Commercial Envoy Wi-Fi network available AP mode disabled: IQ Envoy Wi-Fi network unavailable All communicating microinverters are producing Microinverter upgrade in progress At least one microinverter is not producing Microinverters are not producing or communicating (low light or night time) All devices are communicating Device scan in progress At least one device is not communicating Devices are not communicating (low light or night time) If the Device Communications LED lights solid amber, it may be a result of low light levels. If there isn t enough sunlight to power up the microinverters, they can t communicate with the Envoy. If there is sufficient daylight for the microinverters to power up, the issue may be that the IQ Commercial Envoy is having difficulty communicating over the power lines. To troubleshoot this issue: Check the Installer Toolkit mobile app to see which devices are not communicating. Check that the circuit breaker(s) for the PV array are in the ON position. Verify that the PV modules are connected to the microinverters. Verify the PV module DC voltage is within the allowable range for the microinverter. c Power production issues If the Power Production LED lights solid amber, check the Installer Toolkit mobile app to see which microinverters are not producing: If none of the microinverters are producing power, there may be a grid or wiring issue. First, verify that there is proper input voltage and frequency from the grid. Next, check the breaker and wiring, starting at the load center. If all the non-productive microinverters are on the same branch, check the breaker and wiring starting at the junction box for the affected branch. If only one or scattered microinverters are not producing power, first check to see that the AC connectors are fully connected. Next, check that each module is providing the required startup voltage for the microinverter (22V). A PV module that is failing or that is undersized may not generate enough power for AC conversion. d Internet connection issues If you are using Wi-Fi and the Network Communications LED remains off: The WPS connection window may have timed out. Retry the connection steps. Make sure that the broadband router is operational by checking that other devices at the site can access the network. Be aware that metal enclosures or obstructions impede wireless communication. If you cannot see your router or access point in the list on the Envoy, or cannot maintain a connection, it may be necessary to add a wireless repeater to extend the network range. If you are using Wi-Fi and the Network Communications LED lights solid amber, make sure that the broadband router is connected to the Internet by checking that other devices at the site can access the Internet. If you are using the Enphase Mobile Connect modem and the Network Communications LED remains off or lights solid amber, see Troubleshooting in the Enphase Mobile Connect Installation Guide. For any connection method, you can troubleshoot network issues with the Installer Toolkit mobile app by tapping the Network button, then Diagnostic Tools. If you replace the broadband router, configure the IQ Commercial Envoy Wi-Fi settings for the new Wireless Network Name (SSID) and password. Or use the WPS function described in step 6.

SAFETY Safety and Advisory Symbols * DANGER: This indicates a hazardous situation, which if not avoided, will result in death or serious injury. WARNING: This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. This indicates information particularly important for optimal system operation. Follow instructions carefully. Safety Instructions * * DANGER: Risk of electric shock. Risk of fire. Do not attempt to repair the IQ Commercial Envoy; it contains no user-serviceable parts. Tampering with or opening the IQ Commercial Envoy will void the warranty. Warranty void if cover removed. If the IQ Commercial Envoy fails, contact Enphase Customer Support for assistance (enphase.com/en-us/support/). DANGER: Risk of electric shock. Always open or disconnect circuit from power-distribution system (or service) of building before installing or servicing current transformers (CTs). DANGER: Risk of electrocution! Do not install CTs when current flowing in the sensed circuit. Always install CT wires in the terminal blocks before energizing the sensed circuit. DANGER: Risk of electric shock. Do not use Enphase equipment in a manner not specified by the manufacturer. Doing so may cause death or injury to persons, or damage to equipment. DANGER: Risk of electric shock. Be aware that installation of this equipment includes risk of electric shock. Always de-energize the load center before beginning wiring. DANGER: Risk of electric shock. Risk of fire. Only qualified personnel should troubleshoot, install, or replace the IQ Commercial Envoy. DANGER: Risk of electric shock. Risk of fire. Do not wire unused terminals or terminal blocks on the IQ Commercial Envoy. WARNING: Before installing or using the IQ Commercial Envoy, read all instructions and cautionary markings in the technical description and on the IQ Commercial Envoy. WARNING: Risk of equipment damage. If installing the IQ Commercial Envoy in an enclosure, choose area for installation where ambient temperature does not exceed 46º C (115º F). Do not install the CTs in a panel where they exceed 75% of the wiring space of any cross-sectional area within the panel, or refer to local standards for guidance. Do not install CTs in an area where they will block ventilation openings, or in area of breaker arc venting. The CTs are not suitable for Class 2 wiring methods and not intended for connection to Class 2 equipment. Secure CT and route conductors so that they do not directly contact live terminals or bus. Perform all electrical installations in accordance with all national and local electrical codes. To ensure optimal reliability and to meet warranty requirements, the Enphase IQ Commercial Envoy must be installed according to the instructions in this guide. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and the receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment. This Class B digital apparatus complies with Industry Canada ICES-003. 2017 Enphase Energy, Inc. All rights reserved. Enphase Customer Support: enphase.com/en-us/support/contact