PHOENIX CONTACT - 06/2006

Similar documents
PHOENIX CONTACT - 02/2007

PHOENIX CONTACT - 10/2009

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000E (SM40) LC

FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E)

PHOENIX CONTACT - 11/2008

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

onlinecomponents.com

PHOENIX CONTACT - 04/2008

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Industrial 3-Port Fast Ethernet Media Converter Switches

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

MINI-PS AC/10-15DC/8

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

Stride Industrial Ethernet Switches

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

Valueline Industrial PC

Industrial Switches Industrial Switches

TRIO-DIODE/12-24DC/2X10/1X20

Hardened PoE Ethernet Switch

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

IBS IL 24 RB-LK-2MBD:

PHOENIX CONTACT - 05/2007

Quick Start Guide. Physical Description. The Port Status LEDs

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

HARTING econ 3000 Introduction and features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Industrial Ethernet Switch

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

KFC-200. Installation Guide

Ethernet. RJ45 Copper Ports

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

MINI MCR-SL-UI-2I(-SP)(-NC)

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

AXL E IOL AO1 U M12 R

114FX6. Phone: Fax: Web: -

QUINT-BUFFER/24DC/24DC/40

gigabit industrial ethernet user manual Models , ,

onlinecomponents.com

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

QUINT-PS-3x AC/24DC/10

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

PHOENIX CONTACT Features

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

PTC-101-M12 Hardware Installation Guide

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

PTC-101 Quick Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

FL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm)

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

IMC-P111FX Series IMC-P111P Series

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

Light Industrial Unmanaged Ethernet Switches. Unmanaged. Technical Details

General information. Display. Supply voltage. Input current

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

General information. Display. Supply voltage

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

IMC-P111FX / IMC-P111P Series

Redundancy Module QUINT-DIODE/40

RS-232 Industrial Media Converter

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

MINI MCR-SL-PT100-UI(-SP)(-NC)

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

FL MC EF 1300 MM ST. FO converter with B-FOC (ST ) connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm)

Quick Start Guide. Physical Description.

General information. Display. Supply voltage. Input current

Industrial Managed Ethernet Switch

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

STEP-PS/1AC/24DC/1.75

Transcription:

FL SWITCH SFN 5TX Ord.-No.: 2891152 FL SWITCH SFN 6TX/2FX Ord.-No.: 2891314 Five and Eight Port Standard Function Ethernet Switches with Narrow Housings AUTOMATIONWORX Data Sheet PHOENIX CONT - 06/2006 Description The FL SWITCH SFN... range of Factory Line switches with standard functions in numerous versions can be used for quick and cost-effective Ethernet network expansion to the field level. Due to their narrow housing design, the components are suitable for universal remote use in control cabinets and junction boxes. The switches have five or eight ports, up to two of which are glass fiber ports provided in SC or ST format. The switches support the auto negotiation function at the twisted pair ports and offer transmission speeds of 10//0 Mbps depending on the switch version. Mixed operation for the connection of segments with different data transmission speeds is also supported. The glass fiber ports only support Mbps or 0 Mbps (Gigabit version). The RJ45 ports offer an auto crossing function, which means it is not necessary to make a distinction between 1:1 and crossover cables. The fiber optic ports can be used to extend the segment length up to 20 km. Unused RJ45 ports can be fitted with security caps to provide mechanical protection against unauthorized use. Features and Fields of Application Increased network performance - Switched Ethernet reduces traffic and non predictable timing - Quality of Service: Pretagged high priority messages are forwarded before lower priority messages during periods of high network traffic loading - Gigabit options for data intensive applications Easy network expansion - No configuration of the switch - Autonegotiation and autocross simplify cabeling - Coupling copper network segments with different bit rates with automatic detection of the data transmission speed of 10 Mbps, Mbps or 0 Mbps depending on the switch version. Fiber optic options extend distance and electrical noise immunity - 1 or 2 ports option - SC or ST connector options - Multimode or singlemode option Low cost, low complexity security - Connect Layer 1 security elements at the RJ45 port to restrict access or tampering - No software setup needed Please note the different connection directions of the transmission media for five-port switches: copper cables are connected at the front, glass fiber cables at the bottom. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page: 7267_en_00 PHOENIX CONT GmbH & Co. KG 32823 Blomberg Germany 1 Phone: +49-52 35-30 0 Fax: +49-52 35-34 12 00 www.phoenixcontact.com www.phoenixcontact.com/salesnetwork

Ordering Data Products Description Type Order No. Pcs./Pkt. Ethernet switch with 5 RJ45 ports for 10/ Mbps FL SWITCH SFN 5TX 2891152 1 Ethernet switch with 4 RJ45 ports and 1 fiber optic port in SC format for 10/ Mbps Ethernet switch with 4 RJ45 ports and 1 fiber optic port in ST format for 10/ Mbps Accessories FL SWITCH SFN 4TX/FX 2891851 1 FL SWITCH SFN 4TX/FX ST 2891453 1 Ethernet switch with 8 RJ45 ports for 10/ Mbps FL SWITCH SFN 8TX 2891929 1 Ethernet switch with 7 RJ45 ports and FL SWITCH SFN 7TX/FX 2891097 1 1 fiber optic port in SC format for 10/ Mbps Ethernet switch with 7 RJ45 ports and FL SWITCH SFN 7TX/FX ST 2891110 1 1 fiber optic port in ST format for 10/ Mbps Ethernet switch with 6 RJ45 ports and 2 fiber optic ports in SC format FL SWITCH SFN 6TX/2FX 2891314 1 Ethernet switch with 6 RJ45 ports and FL SWITCH SFN 6TX/2FX ST 2891411 1 2 fiber optic ports in ST format for 10/ Mbps Ethernet switch with 8 RJ45 ports for 10//0 Mbps FL SWITCH SFN 8GT 2891673 1 Ethernet switch with 7 RJ45 ports for 10//0 Mbps and 1 fiber optic port in SC format (multi-mode), 850 nm up to 550 m distance Ethernet switch with 6 RJ45 ports for 10//0 Mbps and 2 fiber optic ports in SC format (multi-mode), 850 nm up to 550 m distance Ethernet switch with 6 RJ45 ports for 10//0 Mbps and 2 fiber optic ports in SC format (single mode), 1310 nm up to 10 km distance Ethernet switch with 6 RJ45 ports for 10//0 Mbps and 2 fiber optic ports in SC format (single mode), 1310 nm up to 20 km distance FL SWITCH SFN 7GT/SX 2891518 1 FL SWITCH SFN 6GT/2SX 2891398 1 FL SWITCH SFN 6GT/2LX 2891987 1 FL SWITCH SFN 6GT/2LX-20 2891563 1 Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Dust protection caps for RJ45 female connectors FL RJ45 PROTECT CAP 2832991 10 Security set for 4 RJ45 ports FL SEC PAC 4TX 2832865 4 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patchbox 6 x RJ45 CAT 5e and 4 SC-RJ, glass pre-assembled, can be FL PBX 6TX/4FX 2832506 1 retrofitted Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 2 PHOENIX CONT 7267_en_00

Technical Data General Data Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor 8 µs plus frame time Housing dimensions (width x height x depth) in mm 5-port switch (RJ45) 30 x 120 x 70 (without COMBICON/without fiber optics) 8-port switch (RJ45) 53 x 120 x 70 (without COMBICON/without fiber optics) Operating temperature (10/ Mbit/s switch) 0 C to 60 C Operating temperature (10//0 Mbit/s switch) In preparation Storage temperature (10/ Mbit/s switch) -40 C to 85 C Storage temperature (10//0 Mbit/s switch) -40 C to 80 C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 10% to 95%, no condensation Air pressure (operation) 86 kpa to 108 kpa, 1500 m above sea level Air pressure (storage) 66 kpa to 108 kpa, 3500 m above sea level Preferred mounting position Perpendicular to a standard DIN rail Connection to protective earth ground Snapped onto a grounded DIN rail Weight 5-port switch 260 g, approximately 8-port switch 360 g, approximately Supply Voltage () Connection Nominal value Permissible ripple Permissible voltage range Inrush current Test voltage Protection against polarity reversal Current consumption Current Consumption and Inrush Current Via COMBICON; conductor cross section = 2.5 mm 2, maximum 24 V DC 3.6 V pp within the permissible voltage range 18.5 V DC to 30.2 V DC Depends on the device - see the following table 500 V DC for one minute Present Depends on the device - see the following table Current Consumption (max) FL SWITCH SFN 5TX 90 ma (24 V DC) 2.3 A for 3 ms FL SWITCH SFN 4TX/FX 140 ma (24 V DC) 2.4 A for 2 ms FL SWITCH SFN 4TX/FX ST 140 ma (24 V DC) 2.9 A for 2 ms FL SWITCH SFN 8TX 140 ma (24 V DC) 3.1 A for 2 ms FL SWITCH SFN 7TX/FX 190 ma (24 V DC) 3.4 A for 2 ms FL SWITCH SFN 7TX/FX ST 190 ma (24 V DC) 3.4 A for 2 ms FL SWITCH SFN 6TX/2FX 230 ma (24 V DC) 3.6 A for 2 ms FL SWITCH SFN 6TX/2FX ST 230 ma (24 V DC) 3.3 A for 2 ms FL SWITCH SFN 8GT 430 ma (24 V DC) 3.1 A for 3 ms FL SWITCH SFN 7GT/SX 470 ma (24 V DC) 3.1 A for 3 ms FL SWITCH SFN 6GT/2SX 590 ma (24 V DC) 3.4 A for 3 ms FL SWITCH SFN 6GT/2LX 590 ma (24 V DC) 3.4 A for 3 ms FL SWITCH SFN 6GT/2LX-20 590 ma (24 V DC) 3.4 A for 3 ms Power up Inrush Current 7267_en_00 PHOENIX CONT 3

Interfaces Total number of Ethernet interfaces 5/8 Mac Address Table Size (Entries) 1 K (4, 5, 8 TX versions), 8 K (all others) Properties of RJ45 Ports Number 4, 5, 6, 7 or 8 depending on the device version Connection format 8-pos. RJ45 female connector on the switch Connection medium Twisted pair cable with a conductor cross section of 0.14 mm 2 to 0.22 mm 2 Cable impedance ohms Transmission speed 10/ Mbps or 10/10/0 Mbps network segment expansion m General Properties of Fiber Optic Ports Number 0, 1 or 2 depending on the device version Connection format Mbit/s SC duplex or ST female connector on the switch Connection format 0 Mbit/s SC duplex connector on the switch Laser protection Class 1 according to DIN EN 60825-1:2001-11 Properties of Mbit/s Multimode Transmission rate Mbit/s Full duplex Wavelength 1300/1310 nm Min. transmission length 2 km Fiber optic 50/125 2 km Fiber optic 62.5/125 Transmission power (Medium type) dynamic (average) -23.5 dbm (50/125 µm) / -20 dbm (62.5/125 µm) -14 dbm (50/125 µm) / -14 dbm (62.5/125 µm) Transmission power (Medium type) static -22.5 dbm (50/125 µm) / -19 dbm (62.5/125 µm) -14 dbm (50/125 µm) / -14 dbm (62.5/125 µm) Receiver sensitivity -31 dbm (dynamic) / -31 dbm (static) -14 dbm (dynamic) / -14 dbm (static) Properties of 0 Mbit/s Multimode Transmission rate 1.25 Gbit/s Full duplex Wavelength 850 nm Min. transmission length 260 m Fiber optic 50/125 550 m Fiber optic 62.5/125 Transmission power -9.5 dbm -4 dbm Receiver sensitivity -17 dbm -3 dbm Properties of 0 Mbit/s Singlemode Transmission rate 1.25 Gbit/s Full duplex Wavelength 1310 nm Min. transmission length FL SWITCH 6GT/2LX Min. transmission length FL SWITCH 6GT/2LX-20 Transmission power Receiver sensitivity 10 km Fiber optic 9/125 20 km Fiber optic 9/125-10 dbm -3 dbm -0 dbm -20 dbm 4 PHOENIX CONT 7267_en_00

Interfaces (Continued) Alarm Contact for Gigabit Version Voltage Current carrying capacity 24 V DC, typical ma maximum including inrush Mechanical Tests Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1 m Conformance With EMC Directives Developed according to IEC 60-6-2 IEC 60-4-2 (ESD) IEC 60-4-3 (radiated-noise immunity) IEC 60-4-4 (burst) IEC 60-4-5 (surge) IEC 60-4-6 (conducted noise immunity) IEC 60-4-8 (noise immunity against magnetic fields) EN 55022 (noise emission) Criterion B Criterion A Criterion A Criterion B Criterion A Criterion A Class A Approvals CE, cur, ROHS EEE 2002/95/EC, WEEE 2002/96/EC Differences Compared to Previous Versions Version 00 - First version 7267_en_00 PHOENIX CONT 5

Housing Versions and Position of the Fiber Optic Connections 5 Port Versions The housings of the 5-port versions are identical. Port 5 is located at the bottom. FL SWITCH SFN 5TX Ord.-No.: 2891152 FL SWITCH SFN 4TX/FX ST Ord.-No.: 2891453 726700000 FL SWITCH SFN 5TX FL SWITCH SFN 5TX with FL SEC PAC FL SWITCH SFN 4TX/FX ST Figure 1 Housing example for 5-port switches 6 PHOENIX CONT 7267_en_00

8 Port Versions The housings of the 8-port versions are identical. On the fiber optic versions, the connections for the fiber optic ports are at the front. The physical location of the ports on the 10/ and 10//0 (Gigabit) switches are the same. FL SWITCH SFN 8TX Ord.No.2891929 FL SWITCH SFN 8TX Ord.No.2891929 FL SWITCH SFN 6TX/2FX Ord.No.2891314 FL SWITCH SFN 7TX/FX Ord.No.2891097 72670001 FL SWITCH SFN 8TX Figure 2 FL SWITCH SFN 8TX with FL SEC PAC Housing example for 8-port switches FL SWITCH SFN 6TX/2FX FL SWITCH SFN 7TX/FX Local Diagnostic and Status Indicators for 10/ or 10//0 Mbps Versions Des. Color Status Meaning Green ON Supply voltage in the tolerance range or 1/2 OFF Supply voltage too low LEDs on 10/ Mbps Versions for the Data Transmission Speed (2 LEDs/Port) 10 Mbps Mbps ON/blinking ON/blinking OFF ON LED: ON: indicates an electrical Link Blinking: indicates network traffic (at high data rates the blinking is in a constant rate) 7267_en_00 PHOENIX CONT 7

LEDs on 10//0 Mbps Versions for the Data Transmission Speed (2 LEDs/Port) 10 Mbps Mbps 0 Mbps / ON/blinking ON/blinking OFF 0/ ON/blinking OFF ON/blinking One LED/port ON or blinking: ON: indicates an electrical Link Blinking: indicates network traffic at the data rate (x Mbit/s) General Information Both LEDs/port ON or blinking: Both ON: indicates a 10 Mbit/s electrical Link Both Blinking: indicates 10 Mbit/s network traffic Warning Disregarding this warning may result in damage to equipment and/or serious personal injury. Only qualified personnel may start up and operate these devices. According to the safety instructions in this text, qualified personnel are persons who are authorized to start up, to ground, and to mark devices, systems, and equipment according to the standards of safety technology. In addition, these persons must be familiar with all warning instructions and maintenance measures in this text. Warning The FL SWITCH SFN... module is designed exclusively for SELV operation according to IEC 950/EN 60950/VDE 0805. Using the FL SEC PAC kit for Port Security Layer 1 Port security for up to 4 ports, is provided by purchasing the FL SEC PAC kit. The kit contains 4 red security frames, 4 grey port blocking security caps, unlocking key and instructions. The red security frame must first be attached to each port that is to be secured. First orient the red security frame, so that the cable locking tabs of both the frame and the switch are aligned. Then, insert the 4 mounting feet of the security frame into the pre-punched holes around the switch port and push until the frame snaps into place with an audible click. Once attached, the security frames are permanently mounted and can not be removed. Inserted cables or grey port blocking security caps will now be locked into place. Instructions for using the key to unlock the cables or security caps are included in the kit. 8 PHOENIX CONT 7267_en_00

Installation and Assembly/Removal Install the FL SWITCH SFN... on a clean DIN rail. To avoid contact resistance only use clean, corrosion-free DIN rails. End clamps can be mounted on both sides of the module to stop the modules from slipping on the DIN rail. Connect the DIN rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the DIN rail. Connect protective earth ground with low impedance. Gigabit components have a functional earth ground connecting screw on the top. Assembly: 1. Place the module onto the DIN rail from above. The upper holding keyway must be hooked onto the top edge of the DIN rail. 2. Push the module from the front towards the mounting surface. 3. Once the module has been snapped on properly, check that it is fixed securely on the DIN rail. Removal: 1. Insert a suitable tool (e.g., needle-nose pliers) into the arresting latch and pull it down. 2. Pull the module slightly away from the mounting surface. 3. Lift the module from the DIN rail. Terminal Assignment for 10/ Mbps Versions GND 1 2 3 4 Terminal Meaning 1 Supply voltage + 2 GND 3 Functional earth ground 4 Functional earth ground Figure 3 Terminal assignment Terminal Assignment for 10//0 Mbps Versions 1 GND 2 GND R1 R2 1 2 3 4 5 6 Terminal Meaning 1 Supply voltage + 1 2 GND 1 3 Supply voltage + 2 4 GND 2 5 Alarm contact R1 6 Alarm contact R2 Figure 4 Terminal assignment 7267_en_00 PHOENIX CONT 9

Supply Voltage Connection and Grounding for 10/ Mbps Versions Supply Voltage The switch is designed for SELV operation at +24 V DC according to IEC 950/EN 60950/VDE 0805. Only SELV according to the defined standards may be used for supply purposes. Connection to Functional Earth Ground Snapping the switch onto a grounded DIN rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased by an additional low-impedance connection to functional earth ground via terminal 3 or 4. 24 V DC + - GND 1 2 3 4 Figure 5 Example for supply of a 10/ Mbps module Supply Voltage Connection and Grounding for 10//0 Mbps Versions Supply Voltage The switch is designed for SELV operation at 24 V DC according to IEC 950/EN 60950/VDE 0805. Only SELV according to the defined standards may be used for supply purposes. Operate the module using a +24 V DC SELV. The module is fully operational even with only one supply voltage (without jumpering it to other supply voltage terminal blocks) and/or without wiring the alarm contact (see Figure 6, A). A 24 V DC B 24 V DC + - + - 1 GND 2 GND R1 R2 1 GND 2 GND R1 R2 1 2 3 4 5 6 1 2 3 4 5 6 72670008 Figure 6 Supply of a 10//0 Mbps module from one or two voltage sources Alarm contact operation One or more power supplies failed -> the contact closes Power OK -> the contact opens The maximum current, include inrush, is ma. 10 PHOENIX CONT 7267_en_00

Connection to Functional Earth Ground Snapping the switch onto a grounded DIN rail connects it to the ground potential. In an environment particularly prone to EMI, the switch can be grounded by an additional low-impedance connection to functional earth ground via an eyelet ring on the upper part of the housing. FL SWITCH SFN G6TX/2FX Ord.-No.: 2891398 Figure 7 Grounding via an eyelet ring Ethernet Interface The FL SWITCH SFN... has up to 8 Ethernet ports on the front in RJ45 format, to which only twisted pair cables with an impedance of Ω can be connected. The data transmission speed is 10 Mbps/ Mbps or 10 Mbps/ Mbps/0 Mbps. In addition, every port has an auto crossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet cables. 10/ Mbps 10//0 Mbps RJ45 RJ45 8 7 6 5 4 3 2 1 n.c. n.c ṬD-n.c. n.c ṪD+ RD- RD+ 8 7 6 5 4 3 2 1 DD- DD+ DB- DC- DC+ DB+ DA- DA+ Figure 8 Pin assignment of the Ethernet ports in RJ45 format 7267_en_00 PHOENIX CONT 11

Switching Charakteristics of the FL SWITCH SFN... Store and Forward All data telegrams that are received by the switch are saved and their validity checked. Invalid or faulty data packets (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. Multi-Address Function The switch independently learns the addresses for termination devices, which are connected via a port, by evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. Quality of Service (QoS): IEEE 802.1P/Q The SFN switches are capable of reading Ethernet packets that have already been assignent a priority level by a managed switch or other. In cases of heavy traffic, packets with a priority 4-7 are considered high priority and processed before packets with 0-3 priority level. After prioritization the packets are forwarded without modification. A restart deletes the entire address table. Housing Dimensions 14 mm FL SWITCH SFN 5TX Ord.-No.: 2891152 FL SWITCH SFN 8TX Ord.-No.: 2891929 120 mm 30 mm 53 mm Figure 9 Housing dimensions for the FL SWITCH SFN... The housing depth is 70 mm for all housing versions. PHOENIX CONT 06/2006 12 PHOENIX CONT 7267_en_00