DATA SHEET North Power 5H04 STANDBY POWER: 504 KVA - 403 KW Standard Specifications Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Base frame design incorporates an integral fuel tank and antivibration isolators Flexible fuel connection hoses Single bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately Static battery charger Manual for application and installation PRIME POWER:454 KVA - 363 KW Standby Rating (ESP): Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed. Prime Rating (PRP): Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO Mix Power segment body design Our mechanical engineers improved the compact design of these generators and as such now due to the thin modular design the Forceful mix power generators carry inside all the main parts starting from the engine, alternator, cooling system, electric system, exhaust system and fuel system. This generator is easy to transport and to install to respond to all you emergencies. It is safe and fulfills your need for uninterrupted energy. This compact design has visual and environmental features that make it easy to adapt everywhere. his generator was designed keeping in mind the environment and the ecological system. The cabin of the Forceful generators is soundproof and weatherproof.
DATA SHEET Horse Power Durable Energy Unique design The diesel engine is the most important part of the genset. Is the prime mover that drives the generator (alternator ) to produce electricity. All diesel engines are similar to each other in the concept but they different in many spects such as the number of cylinders, if the cylinders are online or Vtype, how the fuel is delivered to the cylinders,governing system, cooling system, air charging system, air intake system. All these details affect the ecision of which engine to use and which performance is expected. Engines are rated in KW or HP. Their performance is measured in their fuel consumption in filters or gallons per KWh produced, its thermal effciency, noise level, lube oil consumption and exhaust gas emissions. Engine Specifications Manufacturer Model TAD 1345 GE No of Cylinder/ Configuration VERTICAL IN-LINE 6 Displacement Bore/ Stroke 12.78 lt 131mm x 158mm Compression Ratio 18.10:01 Aspiration Turbo Charged AAC Governor Type Electronic Cooling System Water Coolant Capacity Oil Capacity Electrical System 44.0 lt 36 lt 24 VDC Speed/ Frequency 1500rpm / 50Hz Fuel Consumption lt/h 90.0 - %100 67.80 - %75 45.7 - %50 Exhaust Outlet Temperature Exhaust Gas Flow Intake Air Flow Radiator Cooling Air 570 Celcius 58.30 m3/min 27.60 m3/min 410 m3/min
DATA SHEET Self Excited Strong Rotor Isolated Stator Stamford alternator has been designed for three phase and mono phase. They are brushless type and are controlled by AVR card. The windings have been industrially produced to give maximum efficiency in the production of energy. Throughout the AVR card system the output voltage is always stable. The smart AVR is a professional controller than enables the whole operation of excitement. Stamford alternator is protected by a special cabin that enables the electrical connections. Alternator Specifications Manufacturer FMTALTERNATOR Model HCI544C No of Phase 3 Power Factor 0.8 No of Bearing SINGLE No of Poles 4 No of Leads 12 Insulation Class H Voltage Regulation (Steady State) ± % 1 Degree of Protection IP 23 Excitation System Connection System Self Excited, AVR, Brushless STAR Frequency 50 Hz Voltage Output 230 / 400 VAC Rated Power (Standby) Efficiency 520 kva 93.00%
DATA SHEET Measurement Generator Volts: L1-N, L2-N, L3-N Generator Volts: L1-L2, L2-L3, L3-L1 Generator Amps: L1, L2, L3 Generator KW: L1, L2, L3, total Generator pf: L1, L2, L3, total Generator Frequency Engine rpm Mains Volts: L1-N, L2-N, L3-N Mains Volts: L1-L2, L2-L3, L3-L1 Mains Frequency Battery Voltage Engine Coolant Temperature Engine Oil Pressure Fuel Level Engine Oil Temperature Smart Logic Super Control Full Protection FMT 509 / 500 Control Panel The controller is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations. The unit is available with MPU or CANBUS versions. The CANBUS version connects to ECU controlled electronic engines providing engine control, protection and instrumentation without extra senders. The ECU alarms are displayed in text. The unit has an optional internal GSM modem module and is able to initiate modem calls and send SMS messages in fault conditions through either internal or external modems. The unit provides a comprehensive set of digitally adjustable timers, threshold levels, input and output configurations, operating sequences and engine types. All programs may be modified via front panel pushbuttons, and do not require an external unit. Last 100 faults are stored in the event log file. The event log includes not only the date-time information, but also a comprehensive list of measured genset parameters at the time that the fault has occurred. The WINDOWS based RAINBOW program allows remote monitoring and control. The unit supports MODBUS protocol enabling communication with PLCs and building management systems. The MODBUS protocol is also supported through GSM and PSTN modems. The unit offers multiple language support. Features: - True RMS measurements - ECU connection through J1939 CAN option - J1939 ECU warnings displayed as text - MPU input option - Internal GSM modem option - Dual genset mutual standby operation - Event logging with time stamp and measurements - Battery backed-up real time clock - Built in daily / weekly / monthly exerciser - Weekly operation schedule programs - Field adjustable parameters - RS-232 serial port - Optional RS-485 serial port - Free MS-Windows Remote monitoring SW - GSM and PSTN modem support - GSM SMS message sending on fault - MODBUS communications - Multiple language support - Customer logo display capability - 10ADC relay outputs - Configurable analogue inputs: 4 - Configurable digital inputs: 7 - Configurable relay outputs: 2 - Total relay outputs: 6 - I/O expansion capability - Plug-in connection system
DATA SHEET Smart Logic Super Control Full Protection FMT 509 Control Panel DIGITAL INPUTS The unit has 7 configurable digital inputs. Each input is fully configurable with selectable names, alarm type, polling, latching and contact type. ANALOG INPUTS Engine analog inputs are provided for coolant temperature, oil pressure, oil temperature and fuel level. The inputs have programmable sensor characteristics so that they are suitable for any type and brand of sensors. RELAY OUTPUTS The unit provides 6 relay outputs and 2 of them have programmable functions, selectable from a list. Any function or alarm condition may be output as a relay output. Using two Relay Expansion Modules, the number of relays may be increased to 22, 16 of them being volt-free contacts. EVENT LOGGING The unit records last 100 events with date-time stamp and a total of 18 measured parameters. TELEMETRY AND REMOTE PROGRAMMING The unit provides the user with large telemetry facilities via its standard RS-232 serial port, connecting either to a PC, PLC or a GSM or PSTN modem. It supports both RAINBOW and MODBUS communication protocols. The standard PC software offers local and modem operation capabilities as well as modem networking feature. The PC program is used for below purposes: -parameter upload/download -remote monitoring and control -diagnostics and analysis The MODBUS interface allows the unit to be integrated in building management system TECHNICAL SPECIFICATIONS Alternator voltage: 0 to 300 V-AC (Ph-N) Alternator frequency: 0-100 Hz. Mains voltage: 0 to 300 V-AC (Ph-N) Mains frequency: 0-100 Hz. DC Supply Range: 9.0 to 33.0 V-DC Cranking dropouts: survives 0 V for 100ms. Typical Standby Current: 100 ma-dc Maximum Operating Current: 200 ma-dc (Relay outputs open) Generator/Mains Contactor Relay Outputs: 16 A / 250V DC Outputs: 10A @ 28V Charge excitation: min 2 Watts Magnetic pickup input:: 0.5 30 V-AC. Magnetic pickup frequency: 10 KHz max. Current inputs: from CTs,.../5A. Max load 0.7VA per phase. Analog input range: 0-5000 ohms. Serial port: RS-232, 9600 bauds, no parity, 1 bit stop Operating temp.: -20 C (-4 F) to 70 C (158 F) Storage temp.: -40 C (-40 F) to 80 C (176 F) Maximum humidity: 95% non-condensing Dimensions: 200 x 148 x 46 mm (WxHxD) Panel Cut-out Dimensions: 176x121 mm minimum. Weight: 450 g (approx.) Case Material: High Temperature ABS/PC (UL94-V0) IP Protection: IP65 from front panel, IP30 from the rear CE Conformity reference standards: EN 61010 (safety requirements) EN 61326 (EMC requirements) UL / CSA Conformity: certificate # 20110527-E314374 UL 508, Edition 17 UL 2200, 1st Edition. UL 840 Edition 3 CSA C22.2 NO. 14 - Edition 10
DATA SHEET Smart Logic Super Control Full Protection FMT - 509 (Automatic Transfer Switches) An ATS is a device that interfaces with a generator and the yours electrical system. It monitors the utility power and signals the generator to start if the utility power goes out of spec or drops out entirely (blackout). Backup power is now fed to the main utility panel or an emergency panel via the ATS. All FMT group generators has the ATS system. FMT MIX POWER SEGMENT DIESEL GENERATORS DIMENSIONS W x L x H (mm) Canopied Open Skid 1700 x 4500 x 2300 1700 x 4500 x 2200 Weight (kg) 4280 3150 Fuel Tank (lt) 1000 1000 Noise db (A) 7 mt@ 70-75dBA www.fmtgroup.al ISO 9001:2008 Manufacturer reserves the right to make changes in model, technical specifications, colour, equipment and accessories without prior notice.