DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

Similar documents
DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

CNT24-2(USB)GY. Features. Isolated Counter Input Module for USB 2.0 CNT24-2(USB)GY 1. Ver.1.03

DIO-1616LN-FIT DIO-0808LN-FIT

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

DATENBLATT CNT24-2(FIT)GY. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

ADI12-8(USB)GY. Features. Packing List. F&eIt Series Isolated Analog Input Module for USB ADI12-8(USB)GY 1. Ver.1.02

DIO-6464LX-USB. Features. Digital I/O Unit with Opto-Isolation for USB DIO-6464LX-USB 1. Ver.1.00

DIO-1616B-PE. Features. Packing List. PCI Express-compliant Opto-isolated Digital I/O Board with On-board power supply DIO-1616B-PE 1. Ver.1.

AO-1604LX-USB. Features. High-Resolution Analog Output Unit for USB AO-1604LX-USB 1. Ver.1.01

DIO-1616TB-PE. Features. Packing List. PCI Express-compliant High-Speed TTL level Opto-isolated Digital I/O DIO-1616TB-PE 1. Ver.1.

Features. Digital I/O Board with Opto-Isolation for PCI PIO-32/32L(PCI)H. Digital Input Board with Opto-Isolation for PCI PI-64L(PCI)H

PIO-32/32L(PCI) Features. Specification. Ver PCI Bus Opto-Isolated Digital I/O Board PIO-32/32L(PCI)

DC562, digital input/output module,

Communication & Networking

ADI12-16(PCI) Isolated Multi-Function Analog Input Board for PCI ADI12-16(PCI) 1. Ver.1.01

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Communications & Networking

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

User s Manual. Digital I/O Module with Opto-Isolation for USB DIO-8/8(USB)GY. Digital Input Module with Opto-Isolation for USB DI-16(USB)GY

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

PC-HELPER. USB I/O Unit X Series Digital I/O Unit with Opto-Isolation for USB DIO-3232LX-USB. User s Guide CONTEC CO.,LTD.

WARNING 25.2 POWER L.V X1 X2 Y0 C1 Y1 C2 Y2 C3 Y3 ELC-EX NN. 3. Extension unit clip 4. Input/output terminal

DX561 Digital Input/Output Module

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

COM-2CL-PCI COM-4CL-PCI. Features. Packing List. PCI-compliant 2 port Isolated RS-232C. PCI-compliant 4 port Isolated RS-232C

DI-128RL-PCI. Specification. Features. Negative-Common Opto-Isolated Digital Input for PCI DI-128RL-PCI 1. Ver.1.00

DC561, digital input/output module,

PC-HELPER. PCI Express Expansion Chassis Long size, 4-Slots ECH-PE-CE2-F4A. User s Manual CONTEC CO.,LTD.

Model Number Structure

ADLINK PCI The wide input range of the PCI-7432 makes it easy to sense the status of external devices. Supports a 32-bit 5 V PCI bus

Voltage Current Front-mounting bracket

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE AI-1616L-LPE 1. Ver.1.01

General Specifications

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

TM3DI16 module TM3-16 inputs

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

DI561 Digital Input Module

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Bi-Directional Digital I/O Unit for USB DIO-48DX-USB User s Guide

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

Model Number Structure

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Time Counters mini "h", DC Version

USER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

PC RELAY TERMINAL/ PC TERMINAL

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Expansion Module HZS 541-1S

F&eIT Series. 10M/100M AUTO-MDIX Switching HUB (8-port) SH-8008(FIT)H. User s Manual CONTEC CO.,LTD.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


PC-HELPER. Digital I/O Unit with Opto-Isolation for USB (On-board Power Supply) DIO-1616BX-USB. User s Guide CONTEC CO.,LTD.

DIO-6464L-PE. Digital I/O Board with Opto-Isolation for PCI Express DIO-6464L-PE 1. Ver.1.10

Communications & Networking

RS232C/RS485 Data can be easily monitored by LAN

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Suitable for detecting transparent films or transparent bottles

PC-HELPER. PCI Express Expansion Chassis Long size, 4-Slots ECH-PE-CE-F4A. User s Manual CONTEC CO.,LTD.

TU531, TU532 Terminal Unit

N Series for USB Multifunction DAQ Unit (16ch AI, 2ch AO, 16ch DIO) AIO LN-USB

RT-1 PC RELAY TERMINAL RT-1 PC TERMINAL

PO-32B(PC)H. Specification. Features. Ver Opto-Isolated Digital Output Board

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

DI572 Digital Input Module

SiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3.

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Features. Specifications. Digital Output Board with independently common Relay-Isolation for PCI RRY-16C(PCI)H

User's Manual. FP7 Digital Input/Output Unit PROGRAMMABLE CONTROLLER

DC541 Digital Input/Output Module

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

TRIO-DIODE/12-24DC/2X10/1X20

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

General information. Display. Supply voltage. Input current. Encoder supply. Output current

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

User safety and equipment protection guidelines

PC-HELPER. Digital I/O Unit with High Voltage Isolation for USB DIO-1616RYX-USB. User s Guide CONTEC CO.,LTD.

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

Compact Inductive Proximity Sensor

Electronic timer CT-AHD.22

Transcription:

Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and output unit of F&eIT remote I/O system that realizes monitoring and control of devices scattered remotely, through PCs connected to Ethernet. Since existing network infrastructure can be used, the system can be built easily by just connecting with LAN cables. It is possible to connect external devices, such as adjacent switches, lamps and LEDs, to perform input/output of digital signals. Compact design not restricting installation location (188.0(W) x 78.0(D) 30.5(H)) makes it easy to install the product within the panel or device using DIN rail mounting jigs, or on the floor or wall. Windows driver library is supplied. It is possible to confirm the operations through the diagnosis monitor without any programming. This product has the 16ch of isolated inputs and 16ch of isolated open-collector outputs (input : 12-24VDC specification, output : 12-48VDC specification). section corresponds to both of current sink and current source outputs. The output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch. Features isolated inputs (for use with current sink output / current source output), isolated open-collector outputs (current sink type) This product has the 16ch of isolated inputs (for use with current sink output / current source output) and 16ch of isolated open-collector outputs (current sink type). The output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch. Common terminal provided per 8ch, capable of supporting a different external power. You can check the digital input or output by using the LED indicator. bus isolation As the Ethernet controller (PC) side is isolated from the input and output interfaces by s, this product has excellent noise performance. This product has a digital filter to prevent wrong recognition of input signals from carrying noise or a chattering. This product has a digital filter to prevent wrong recognition of input signals from carrying noise or a chattering. All input terminals can be added a digital filter, and the setting can be performed by software. Fail safe function When communication failure occurs, such as LAN cable disconnection, it is possible to notify the external devices by outputting a specific user-defined signal pattern. Compact design not restricting installation location (188.0(W) x 78.0(D) x 30.5(H)) Compact design of 188.0(W) 78.0(D) 30.5(H) does not require special installation location. Compatible with a wide range of power supplies : 5 to 24VDC Compatible with a wide range of power supplies : 5 to 24VDC, and can be used in various environments. An FG terminal is also provided in the power connector. Furthermore, it is possible to screw fit the power connector on to the body to prevent detachment. Can be used as digital input/output of Ethernet base remote I/O As the control (monitoring and control) of digital input/output is performed via Ethernet, remote control can be easily performed. Diverse installations such as screw fastening, magnet, DIN rail are possible Installation on the floor / wall /ceiling is possible by screw fastening, magnet, rubber feet, etc. In addition, DIN rail mounting mechanism is equipped as standard with the product, making it easy to install the product within the panel or the device. Windows compatible driver libraries are attached. Using the attached driver library makes it possible to create applications of Window. As the driver library was designed taking into consideration compatibility with the API functions [API-PAC(W32)] of the measurement control and communication interface board, if you have experience in these applications, smooth programming is possible. In addition, a diagnostic program by which the operations of hardware can be checked is provided. In addition, using generic socket functions makes it possible to implement control under OS other than Windows, such as UNIX machine. Specification Specifications < 1 / 2> Specifications section format isolated input (compatible with current sink output and current source output) resistance ON current 2.0mA OFF current 0.16mA or less Number of input signal 16 channels (8 channels / ) channels Response time Within 1msec power 12-24 VDC (±15%) (2.5 ma / 12V, 5 ma / 24V per channel) section format isolated open collector output (current sink type) Ratings 12-48VDC (±15%) voltage current 150 ma (12-24V) (per channel) (Max.) 50 ma (36-48V) (per channel) (Max.) Number of output signal 16 channels (8 channels / ) channels Response time Within 1msec power 12-48VDC (±15%) Common section Allowable distance of Approx. 50m (depending on wiring environment) signal extension Applicable wire AWG28-16 Applicable plug AK1550 / 10-3.5-GREEN (mfd. by PTR) DIO-1616LN-FIT 1

Specifications < 2 / 2> LAN Power voltage Specifications 10/100BASE-TX(IEEE802.3u) 5-24VDC±10% from 2-piece power input detachable type connector It is recommended that you use F&eIT series power unit or stabilized power product on the market. Maximum extension between power device and the product : 1.5m Current consumption 5VDC 0.60A, 12VDC 0.26A, 24VDC 0.14AA (Max.) FG Power connector equipped with a FG. Power input connector 2-piece power input detachable type connector with an FG terminal supplied Uses connector : MC1,5/3-GF-3,5 (mfd by Phoenix Contact) The dedicated plug, with screw fastening that can be operated from the side, is supplied as standard Compatible connector : MC1,5/3-STF-3,5 (mfd by Phoenix Contact) Compatible cable : AWG28-16 Physical dimensions (mm) 188.0(W) x 78.0(D) x 30.5(H) (No protrusions) Weight 220g (Only the unit) Installation method One-touch connection to 35mm DIN rails DIN rail mounting mechanism as a standard feature. Mounting to the wall using the screws Mounting to a metal surface using the magnets Mounting to the floor using the rubber feet Installation Environment Requirements Requirement description Operating temperature 0-50 C *1 Operating humidity 10-90%RH (No condensation) Floating dust particles Not to be excessive Corrosive gases None Noise immunity Line-noise *2 AC line / 2kV, Signal line / 1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3) Vibration Static electricity resistance Sweep Contact discharge / 4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2) Atmospheric discharge / 8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3) 10-57Hz / semi-amplitude 0.15mm, 57-150Hz / 2.0G resistance resistance 40minutes each in X, Y, and Z directions (JIS C60068-2-6-compliant, IEC60068-2-6-compliant) Impact resistance 15G half-sine shock for 11ms in X, Y, and Z directions (JIS C60068-2-27-compliant, IEC60068-2-27-compliant) Grounding Class D grounding (previous class 3 grounding) *1 When using the attached AC adaptor POA201-10-2, it is 0-40 C *2 When using a POA201-10-2 Packing List [DIO-1616LN-FIT] 1 First step guide 1 Power connector 1 I/O connector 4 Rubber feet 4 Magnet 2 CD-ROM [F&eIT Series Setup Disk] *1 1 *1 The CD-ROM contains various software and User s Manual. Physical Dimensions (154) 170 188 4 (55) 66 78 (4) f3.5 20 30.5 Physical Dimensions<AC Adapter POA201-10-2(Option)> Model with 2P Inlet, no polarity UL,VDE standard product (mm) Support Software API-CAP(W32) [Stored on the bundled CD-ROM F&eIT Series Setup Disk] The API-CAP(W32) is the Windows version driver library software that provides products in the form of Win32 API functions (DLL). Various programming languages such as Visual Basic and Visual C++ can be used to create high-speed application software which maximizes the features of the F&eIT module. In addition, a diagnostic program, which is useful for operation verification, is also provided. < Operating environment > OS Windows 7, Server 2008, Vista, XP, 2000., etc Adaptation language Visual C++, Visual Basic., etc F details on the supported OS, applicable language and how to download the updated version, please visit the CONTEC s Web site (http://www.contec.com/). Option list POA201-10-2 : AC adapter (input : 90-264VAC, output : 12VDC 1.0A) POA200-20-2 : AC adapter (input : 90-264VAC, output : 5VDC 2.0A) POW-AD13GY : AC-DC power unit (input : 85-132VAC, output : 5VDC 3.0A) POW-AD22GY : AC-DC power unit (input : 85-264VAC, output : 5VDC 2.0A) POW-DD10GY : DC-DC power unit (input : 10-30VAC, output : 5VDC 3.0A) POW-DD43GY : DC-DC power unit (input : 30-50VAC, output : 5VDC 3.0A) * Check the CONTEC s Web site f information on these options. Connecting an Interface Connector When connecting the unit to an external device, you can use the supplied connector plug. When wiring the unit, strip off approximately 7 mm of the covering for the cable, and insert the bare wire by pressing the orange button on the connector plug. Releasing the orange button after the wire is inserted fixes the cable. Compatible wires are AWG 28-16. 7mm - Connector used : 3.5mm pitch, 10 type of rated current 9.0A STL1550/10G-3.5-H-GREEN [mfd. by PTR] - Compatible plug (supplied) : AK1550/10-3.5-GREEN [mfd. by PTR] Compatible wires : AWG28-16 CAUTION Removing the connector plug by grasg the cable can break the wire. [mm] DIO-1616LN-FIT 2

Signal Layout on the Interface Connector The unit can be connected to an external device using 10- connectors that is provided on the unit face. Connector : 4 INPUT 1 INPUT 0 OUTPUT 1 OUTPUT 0 Connecting a Switch side plus (Ex : COM of connector INPUT 0) (Ex : Bit 0 of connector INPUT 0) + External power - COM N.C. 7 6 5 4 3 2 1 0 COM N.C. 7 6 5 4 3 2 1 0 COM COM 7 6 5 4 3 2 1 0 COM COM 7 6 5 4 3 2 1 0 1 2 1 2 INPUT0 INPUT1 Pin No. IN00-17 OUT00-17 N.C. COM Signal name bit port Contents Pin No. Signal name bit 0 IN00 0 0 OUT00 0 1 IN01 1 1 OUT01 1 2 IN02 2 2 OUT02 2 3 IN03 3 0 3 OUT03 3 4 IN04 4 4 OUT04 4 5 IN05 5 5 OUT05 5 6 IN06 6 OUTPUT0 6 OUT06 6 7 IN07 7 7 OUT07 7 N.C. N.C. - - Not connected port COM0 COM(-) - - COM COM - - / minus INPUT0 COM1 COM(+) - - 0 IN10 8 0 OUT10 8 1 IN11 9 1 OUT11 9 2 IN12 10 2 OUT12 10 3 IN13 11 1 3 OUT13 11 4 IN14 12 4 OUT14 12 5 IN15 13 5 OUT15 13 6 IN16 14 OUTPUT1 6 OUT16 14 7 IN17 15 7 OUT17 15 N.C. N.C. - - COM COM - - Not connected / minus INPUT1 COM0 COM(-) - - COM1 COM(+) - - Contents 0 OUTPUT0 OUTPUT0 1 OUTPUT1 OUTPUT1 16 input signal s. Connect output signals from the external device to these s. 16 output signal s. Connect these s to the input signal s of the external device. This is left unconnected. Connect the positive or negative side of the external signal. These s are to 8 input signal s. COM0 Connect the negative side of the external signal. These s are to 8 output signal s. COM1 Connect the positive side of the external signal. These s are to 8 output signal s. Examples of Connection to an External Device Example of a Connection between and Current Sink Example of a Connection between and Current Source Current sink output Current source output Connecting Signals Circuit Connecting Signals / contact point Circuit 12-48VDC contact point Figure above shows the input equivalent circuit for the interface section of this product. The signal input section consists of an isolated input (compatible with both current sink output and current source output). An external power is therefore required to drive the input section of this unit. The power requirement is about 5 ma per input channel at 24 VDC (about 2.5 ma at 12 VDC). Figure above shows the output circuit for the interface section of this product. The signal output section consists of an isolated open collector output (current sink type). An external power is therefore required to drive the output section of this unit. The maximum output current rating per channel is 150 ma (at 12-24 VDC) or 50 ma (at 36-48 VDC). A surge voltage protection circuit (zener diode) is provided for the output transistors of this unit. When the unit drives relays, lamps, and other induction loads, however, another surge voltage countermeasure should be provided on the load side. CAUTION When the power is turned on, all output will be OFF. DIO-1616LN-FIT 3

Connection to the LED Installation Method plus (Ex : COM1 of connector OUTPUT 0) + External power 12-48VDC - Mounting on a DIN Rail side (Ex : BIT 0 of connector OUTPUT 0) minus (Ex : COM0 of connector OUTPUT 0) Examples of Connection to an External Device Example of a Connection between and Current Sink Sink output-compliant input Desktop Installation When required to mount the product on the desktop, mount it on a horizontal platform. The rubber feet can be mounted in their mounting holes as shown in the following figure. Connection Method between and Source -Compliant Wall Installation To mount the product on the wall, purchase the commercially available screw (fitting for φ3.5) separately. Source output-compliant input Screws Example of a Connection between and Figure below shows the example of a connection between input of input unit and output of output unit. External power - + Installation Using the Magnet Attaching the magnet supplied with the product makes it easy to mount or remove the product on or from a metal surface such as steel desk or partition. 2 1 unit plus unit plus minus DIO-1616LN-FIT 4

1 2 34 56 7 7 9ABCDEF08 9 ABCDEF08 Ver.1.01 Example of a Mounting on the partition Installation Condition Spacing between the system unit and any surrounding objects Secure a distance of at least between the top of the main unit (single use) and any surrounding objects. Do not locate the unit in a fully enclosed housing. It is possible to mount it in the orientations shown in the following figure. Other orientations would cause problems in usage, such as inadequate heat dissipation. 12 34 56 DIO-1616LN-FIT 5