Control and automatic dosing

Similar documents
*suitable both for membrane sensors or chlorine open cell

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

Neon pr. ph/ ORP measurement. Applications. Description

Instruction manual of the controller unit. PCS ph-redox-chlorine-temp PCS ph-oxygen-temp PCS ph-redox-temp

Signet ph/orp Transmitter * *

Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

Please enter the identity code of your device here!

GENERAL SAFETY GUIDELINES

Control instruments GUARDIAN 2 - GUARDIAN 3

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

LDCL DIGITAL CONTROLLER OPERATING MANUAL

Controllers. Water Treatment

4801P ph/orp controller

Please enter the identity code of your device here!

WATERGUARD WG-602 FREE CHLORINE ANALYZER. User Manual

Controllers. Metal Finishing. and Surface Treatment

Digital O.R.P. Transmitter Type 8206

EL300. Multi-Channel Water Controller. Specialist Of UV Spectroscopy

LDS - LDS PLUS SINGLE READING DIGITAL SYSTEM. DELAY Programmable delay at dosing start-up (up to 60 minutes).

Waterproof Tester ph - mv - Conductivity - TDS - Salinity - Temperature

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

Type Multichannel Transmitter/Controller multicell for Flow and Analytical Sensors

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

SIGNET 5700 ph/orp Monitor - ORP Instructions

Cole-Parmer Instrument Company

Manual. MegaTron Controller Supplemental. Modbus / TCP Communications Manual

Signet 9900 Transmitter

+GF+ SIGNET ph/orp Transmitter Instructions

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features.

Electronic Dosing Systems Ltd

Conductivity Transmitters

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments. ISO 9001: 2000 Certificated since 2001

LDCL DIGITAL CONTROLLER O P E R A T I N G M A N U A L

MMT330 Series Moisture and Temperature Transmitters for Oil

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

Signet 5700 ph/orp Monitor - ph Instructions

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

ProMinent DDC Analyzers

Waterproof Testers. ph - mv - ORP - Conductivity - TDS - Salinity - Temperature

WK7200. Water Quality Test Kit USER S MANUAL

SIGNET ph/orp Transmitter

User's Guide. Online Meters. PH / ORP / TDS / Conductivity.

ENVIRONMENTAL MONITORING & CONTROL

T80 Universal Transmitter S80 Intelligent Sensors

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

world class water monitoring series 42

Contents. 1. Installation

SMART SENSORS. Water quality sensors with built in digital & analog microtransmitters

LD MULTICHANNEL - LD MULTICHANNEL PLUS

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

1 PoolManager 5 Software Releases Overview

Solutions to the Most Challenging Environments

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

The Art of Measuring. Compact Transmitter with Modbus Interface. MemoRail Modbus

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3

Operation Manual ph/orp and Temperature Trasmitter

How to build a Conductivity Measurement System

Room controller STRA-17

FLS M9.06. ph/orp MONITOR

ENVIRONMENTAL MONITORING & CONTROL

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Interface Level Analyzers & Sensors

LAUREL ELECTRONICS, INC.

ph / ORP, RESIDUAL CHLORINE AND TEMPERATURE ANALYZER

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01

Digital ph-controller

mxcontrol Multifunction Controller

Intelligent SUNTEX EC4110(RS) Conductivity Transmitter

Instruction Manual. Liquitron DP5000 Series ph Controller. For file reference, please record the following data:

Cole-Parmer Instrument Company

MultiLine IDS Portable Meters. PORTABLE MULTIPARAMETER MEASUREMENT OF ph, DISSOLVED OXYGEN, CONDUCTIVITY AND TURBIDITY

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

Microprocessor ph/orp Controller

ph 500 & mv 600 Series

Stratos Pro A4 PH. Connection

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

Tachometer Panel, PE3

DIN-Rail Mounted Ultrasonic Flow Meter

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments

Instruments and Capabilities (Panel Mount and Standalone) By: Thornton Leading Pure Water Analytics

ph Meter & Controller Model: NANO-PCD1

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

ProMinent D1C and D2C Analyzers

Microprocessor SUNTEX EC-410/430. Conductivity Monitor

Digital Controllers in Water Treatment Applications

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP

Product data sheet accessories control and regulation Accessories AIRWIN

Operating Instructions

Welcome to the Webinar

Transcription:

Control and automatic dosing For public and residential pools Control Basic and Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control

Dosing through automatic control of Chlorine and ph Nowadays, who does not look for products that can facilitate oneself s work? In the pools world there are many options that allow to automatically control the hard work of keeping the pool clean and in perfect conditions. The automation of dosing and control of chemical products is a step forward from manual processes and is not incompatible with other treatments. With a Free Chlorine sensor or ORP and a ph electrode, concentration levels of the pool can be determined. These measures are analyzed by a controller, the user must first get optimal setpoints of Free Chlorine and ph.

CONTROL BASIC PLUS CONTROL BASIC NEXT Dimensions: 234 x 162 x 108 mm Weight: 1,5 kg. Power Supply: 230 Vac Wall mounting installation or on a tank (with optional accessories) Display: LCD 2 lines, 16 digits Inputs and Outputs: Pt100 temperature Input (electrode not included) Input for minimum level of chemical product ON/OFF remote control Input (230 Vac) Alarm Relay 250 Vac 10A Output Relay for external element 250 Vac 10A (ex. solenoid valve) Power switch Dimensions: 191 x 155 x 123 mm Weight: 1 kg. Power Supply: 230 Vac Wall mounting installation Display: LCD 2 lines, 8 digits Inputs and Outputs: ON/OFF remote control Input (230 Vac) One system for ph or ORP, electrodes are sold separately NEXT Series The new Series NEXT includes the ph and ORP electrode, depending on the chosen version. 66156 Control Basic ph SPA NEXT 0,4 l/h / 1,5 bar with ph electrode Control Basic Series 66157 Control Basic ORP SPA NEXT 0,4 l/h / 1,5 bar with ORP electrode 57129 Control Basic PLUS 1,5 l/h // 1,5 bar (electrode not included) 66162 66163 Control Basic ph NEXT 1,5 l/h // 1,5 bar with ph electrode Control Basic ORP NEXT 1,5 l/h // 1,5 bar with ORP electrode 57130 Control Basic PLUS 5.0 l/h // 1,5 bar (electrode not included) 66336 66337 Control Basic ph NEXT 3,0 l/h // 1,5 bar with ph electrode Control Basic ORP NEXT 3,0 l/h // 1,5 bar with ORP electrode 57131 Control Redox Basic EV (electrode not included) 66174 Control Redox Basic EV NEXT with ORP electrode Control Basic Plus Series 66159 Control Basic PLUS 1,5 l/h // 1,5 bar (electrode not included) 66160 Control Basic PLUS 5,0 l/h // 1,5 bar (electrode not included) 66161 Control Redox Basic EV (electrode not included) Electrodes with Buffer Solutions 36004 36005 ph kit with ph4 and ph7 buffer solutions ORP kit with 465mV buffer solution Fluidra Connect Compatible. System compatible with the Fluidra Connect platform

CONTROL BASIC DOUBLE ph - EV (with Solenoid Valve) Dimensions: 234x162x108 mm Weight: 1 kg. Power Supply: 230Vac Wall mounting installation (accessories are included) Display: LCD 2 lines, 16 digits Inputs and Outputs: Pt100 temperature Input (electrode not included) Input for minimum level of chemical product ON/OFF remote control Input (230 Vac) Alarm Relay 250 Vac 10A for ph Alarm Relay 250 Vac 10A for ORP Power Switch Control Basic Double ph - EV 66158 Control Basic Doble ph - EV SPA 0,4 l/h 64983 Control Basic Doble ph - EV 1,5 l/h Items included with the Solenoid Valve system: ph electrode with 6m cable ORP electrode with 6m cable ph4, ph7 and 465mV buffer solutions ph and ORP electrode supports 2 DN50 clamp saddles Multilingual instruction manual

OPTIMA MAN OPTIMA MAN NEXT Dimensions: 237,5x233,5x109 mm Weight: 1,5 kg. Power Supply: 230 Vac with plug Wall mounting installation (accessories are included) or optionally with fixing bracket on the tank (code 36830) Double regulation: 0-100% or 0-20% Dimensions: 191x155x131 mm Weight: 1 kg. Power Supply: 230 Vac without plug Wall mounting installation (accessories are included) Regulation 0-100% Inputs and Outputs: Input for minimum level of chemical product Power Switch Optima Man Optima Man Next 57132 Optima MAN Tipo B (5 l/h // 10 bar - 8 l/h / 2 bar) 66164 Optima MAN NEXT (3 l/h // 10 bar - 5 l/h // 8 bar) 57133 57135 Optima MAN Tipo C (10 l/h // 10 bar - 18 l/h / 1 bar) Optima MAN Tipo D (20 l/h // 5 bar - 40 l/h / 2 bar)

OPTIMA PRO OPTIMA PRO NEXT Dimensions: 237,5x233,5x109 mm Weight: 1,5 kg. Power Supply: 230 Vac with plug Wall mounting installation (accessories are included) Optionally with fixing bracket on the tank (code 36830) Display: LCD 2 lines, 16 digits Inputs and Outputs: Visualisation in pulses/minute, l/h, gal/h, Input for minimum level of chemical product Analogical lnput 0/4 20 ma or vice versa Pulse Input for proportional dosing through pulse-sender water meter ON/OFF Remote control Dosing probe Input (optional) Dimensions: 191x155x131 mm Weight: 1 kg. Power Supply: 230Vac without plug Wall mounting installation (accessories are included) Display: LCD 2 lines, 8 digits Inputs and Outputs. Visualisation in pulses/minute Input for minimum level of chemical product Analogical Input 0/4 20 ma or vice versa Pulse Input for proportional dosing with a pulse-sender water meter ON/OFF Remote control Optima Pro Optima Pro Next 57136 Optima PRO Tipo B (5 l/h // 10 bar - 8 l/h // 2 bar) 66165 Optima PRO NEXT (3 l/h // 10 bar - 5 l/h // 8 bar) 57137 57138 Optima PRO Tipo C (10 l/h // 10 bar - 18 l/h // 1 bar) Optima PRO Tipo D (20 l/h // 5 bar - 40 l/h // 2 bar)

OPTIMA ph/orp OPTIMA ph/orp NEXT Dimensions: 237,5x233,5x109 mm Weight: 1,5 kg. Power Supply: 230 Vac with plug Wall mounting installation (accessories are included) Optionally with fixing bracket on a tank (code 36830) Display: LCD 2 lines, 16 digits Inputs and Outputs: Pt100 temperature Input (electrode not included) Level control Input Dosing probe Input (optional) Pulse-sender water meter Input ON/OFF Remote control Alarm Relay Output 4... 20mA Output for measurement repeatability without galvanic isolation Dimensions: 191x155x131 mm Weight: 1 kg. Power Supply: 230Vac without plug Wall mounting installation (accessories are included) Display: LCD 2 lines, 8 digits Inputs and Outputs: Pt100 temperature Input (electrode not included) Level control Input ON/OFF Remote control Optima ph/orp NEXT 66166 Optima ph/orp NEXT (3 l/h // 10 bar - 5 l/h // 8 bar) Electrodes with Buffer Solutions Optima ph/orp 36004 ph kit with ph4 and ph7 buffer solutions 57140 Optima ph/orp Tipo C (10 l/h //10 bar - 18 l/h // 1 bar) 36005 ORP kit with 465mV buffer solution 66179 Optima ph/orp Tipo C (10 l/h // 10 bar - 18 l/h // 1 bar) Electrodes with Buffer Solutions 36004 36005 ph kit with ph4 and ph7 buffer solutions ORP kit with 465mV buffer solution Fluidra Connect Compatible. System compatible with the Fluidra Connect platform

PANELS FOR GALVANIC CONTROL 66178 Control Panel ph / ORP / Temperature 66177 Control Panel ph / Galvanic Free Chlorine ph measure range: 0.0-14.00 ORP measure range: -1500mV - +1500mV Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and ORP pumps activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency Output from 20 to 160 pulses/min for ph and ORP pumps activation 0/4-20mA Output for measurement repeatability of ph and ORP Powered ON/OFF Input Input for minimum level of ph and ORP RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket ph7, ph4 and 465mV buffer solutions Manual portable ph and Free Chlorine meter ph and ORP electrodes included ph measure range: 0.0-14.00 Free Chlorine measure range: 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and Free Chlorine pumps activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency Output from 20 to 160 pulses/min for ph and Chlorine pumps activation 0/4-20mA Output for measurement repeatability of ph and Chlorine Powered ON/OFF Input Input for minimum level of ph and Free Chlorine RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket ph7, ph4 and 465mV buffer solutions Manual portable ph and Free Chlorine meter ph and galvanic Free Chlorine electrodes included

66176 Control Panel ph / ORP / Free Chlorine / Temperature 66175 Control Panel ph / ORP / Free Chlorine / Total Chlorine / Temperature ph measure range: 0.0-14.00 ORP measure range: -1500mV - +1500mV Free Chlorine measure range: 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and Free Chlorine pumps activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency Output from 20 to 160 pulses/min for ph and Chlorine pumps activation 0/4-20mA Output for measurement repeatability of ph, ORP and Chlorine Powered ON/OFF Input Input for minimum level of ph and Free Chlorine RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket ph7, ph4 and 465mV buffer solutions Manual portable ph and Free Chlorine meter ph, ORP and Galvanic Free Chlorine electrodes included Free Chlorine measure range: 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for Chlorine pump activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency output from 20 to 160 pulses/min for Chlorine pump activation 0/4-20mA Output for measurement repeatability of Chlorine Powered ON/OFF Input Input for minimum level of Chlorine RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket 465mV buffer solution Manual portable Free Chlorine meter Electrode galvanic Free Chlorine included Fluidra Connect Compatible. System compatible with the Fluidra Connect platform

PANELS FOR AMPEROMETRIC CONTROL 66168 Control Panel ph / Amperometric Free Chlorine 66169 Control Panel ph / ORP / Free Chlorine / Temperature ph measure range: 0.0-14.00 Free Chlorine measure range: 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and Free Chlorine pumps activation Relay 230V 50/60Hz for temperature control Timed Relay 230V 50/60Hz Frequency output from 20 to 160 pulses/min for ph and Chlorine pumps activation 0/4-20mA Output for measurement repeatability of ph and Chlorine Powered ON/OFF Input Input for minimum level of ph and Chlorine RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket ph7, ph4 and 465mV buffer solutions Manual portable ph and Free Chlorine meter ph and Amperometric Free Chlorine electrodes included ph measure range: 0.0-14.00 ORP measure range: -1500mV - +1500mV Free Chlorine measure range: 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and Free Chlorine pumps activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency Output from 20 to 160 pulses/min for ph and Chlorine pumps activation 0/4-20mA Output for measurement repeatability of ph, ORP and Chlorine Powered ON/OFF Input Input for minimum level of ph and Chlorine RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket ph7, ph4 and 465mV buffer solutions Manual portable ph and Free Chlorine meter ph, ORP and Amperometric Free Chlorine electrodes included

66170 Control Panel ph / ORP / Free Chlorine / Total Chlorine / Temperature ph measure range: 0.0-14.00 ORP measure range: -1500mV - +1500mV Free Chlorine measure range : 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and Free Chlorine pumps activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency Output from 20 to 160 pulses/min for ph and Chlorine pumps activation 0/4-20mA Output for measurement repeatability of ph and Chlorine Powered ON/OFF Input Input for minimum level of ph and Chlorine RS485 MODBUS Fluidra Connect Compatible Output Sampling absence detector Fine flow control valve Integrated flow meter 5 filter with 80 micron filter cartridge and mounting bracket ph7, ph4 and 465mV buffer solutions Manual portable ph et and Free Chlorine meter ph, ORP, Amperometric Free Chlorine and Total Chlorine electrodes included Fluidra Connect Compatible. System compatible with the Fluidra Connect platform

POOL PATROL PHOTOMETER 54527 Pool Patrol Photometer ph measure range: 0.0-14.00 ORP measure range: -1500mV - +1500mV Free Chlorine measure range: 0.00 5.00 ppm Temperature measure range: -5-50ºC Relay 230V 50/60Hz for ph and Free Chlorine pumps activation Relay 230V 50/60Hz for Temperature control Timed Relay 230V 50/60Hz Frequency Output from 20 to 160 pulses/min for ph and Chlorine pumps activation 0/4-20mA Output for measurement repeatability of ph, ORP and Chlorine Powered ON/OFF Input Input for minimum level of ph and Chlorine RS485 MODBUS Output Sampling absence detector ph7, ph4 and 465mV buffer solutions ph and Temperature electrodes included First DPD1 charge included FLOC SYSTEM 54528 Floc System Dosing measure range from 0,15 l/h to 1,5 l/h Power supply: 230V 50/60Hz Visualisation in l/h Calibration function Level control Input Remote control 230V 50/60Hz Input Operation Manual Pulses through a pulse-sender water meter 0/4 20 ma 0/4 20 MA

www.astralpool.com