Safety. Detection. Control. The Smallest Size in the World UAM-05LP-T301/C. PL d, Cat. 3, SIL 2, Type 3. Issue 1. Distributed by

Similar documents
Distributed by UAM-05LP-T301/C. short form

EOS4. safety light curtains and grids. short form

Safety. Detection. Control. EOS4. Safety Light Curtains and Grids. Type 4, SIL 3, SILCL 3, PL e, Cat. 4. Issue 1

modular safety integrated controller short form

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

SAFETY & MESUREMENT SERIE SG-BODY BIG

Laser Scanner Compact, lightweight, mini scanner Provides full area coverage over a wide zone

Safety. Detection. Control. Magnus RFID. Your choice for securing moving guards. PL e, SIL 3 RFID Safety Sensors

Magnus RFID. RFID safety switches. short form

Safety Light Grid Orion2 Extended

HAND PROTECTION APPLICATIONS

Safety Laser Scanners

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

Datalogic - SG4-Body BIG muting

TYPE3 SAFETY LASER SCANNER Up to 48 Zones

ASI SAFETY & MESUREMENT. SG4-FINGER SERIES. APPlICATIONS

Safety Laser Scanner SE2L

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

SE9Z-B1865. SE2L Series. Safety Laser Scanner. User s Manual

TYPE 4 SAFETY LIGHT CURTAIN EOS4

SAFETY & MESUREMENT SFIN A GER F OT T PR E. TION light CURTAINS EC Y SG4-FINGER SERIES. highlights

Safety Laser Scanner OS32C

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS

5.5 m (70 mm detection capability)

SAFETY DEVICES SG4-HAND SERIES. SAFEasy TYPE 4 LIGHT CURTAINS

Safety. Detection. Control. new. new SAFETY SENSORS. Safety Contactless Sensors and Devices. Product catalogue. Issue 1

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

Safety Light Curtains GuardShield Remote Teach

MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Safetinex Safety light curtains and access control barriers

Absolute encoders - SSI

This Errata Sheet contains corrections or changes made after the publication of this manual.

JC 300 MULTI-AXIS FINGERTIP JOYSTICK

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

Safety. Detection. Control. MAGNUS RFID ENG - REV

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

The World s Smallest TOF Sensor lineup with analog output type

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

SMARTSCAN INFORMATION

OS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area.

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

M1 module TERMINAL SIGNAL TYPE DESCRIPTION OPERATION

8000 Series: Installation Supplement R2-1-12

SAFETY SG BODY BIG BASE SG BODY BIG MUTING SG2-B2-050-OO-E SG OO-E

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

Momentum 171 CCC Processor with Ethernet Communication Port

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured

SAFETY SG BODY COMPACT BASE SG BODY COMPACT MUTING SG2 -S2-050-PP-E

In-Sight 7010C/7200C/7400C

TYPE 4 SAFETY LIGHT CURTAIN JANUS.

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

T4HD: Installation Supplement R8.1.13

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

General-Purpose Photoelectric Sensor

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

Super Slim. Super. Heavy duty. You Will SEE the Difference! Safety Light Curtain SL-V Series. Category4. Type4 SIL3. PLe NEW

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

CSI 6300 SIS Overview

Certus Configurable Safety Module

Operating instructions. Speed monitor D / / 2014

Active Distributors AS-i Safety, Active Distributors AS-i

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Absolute Encoder Multiturn

MODULAR SAFETY INTEGRATED CONTROLLER

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

Modular Safety Integrated Controller. Catalog n.16

LIGHT SCREENS Catalog Safety Supply Maximum Type Model Page Category Resolution Voltage Range. Page Point Systems. Page 42 4.

CERTUS Configurable Safety Module

SMARTSCAN INFORMATION

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

Coded Non-Contact Safety Sensor Eden OSSD

E2Q4 Square Proximity Sensor

F3SL. Safety Light Curtain for Long Distance Detection

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

MSR42 Micro 400 Controller/Muting Module

Mini Photoelectric Sensor

PR602LCD v1.0 Installer Manual Rev. A

Data Sheet for Joysticks

MLD 500, MLD 300 Multiple Light Beam Safety Devices and transceiver with integrated muting

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Rotary Measurement Technology Absolute Encoders, Singleturn

OptoFence. OptoFence OF OF safety light curtains. Description

EZ-SCREEN. Full View L AUTOCAD, STEP, IGES & PDF. Yellow Painted Aluminum. Trip 2 PNP OSSD. Trip

SIL 3 INTRODUCTION SYSTEM DESCRIPTION

Transcription:

Safety. Detection. Control. The Smallest Size in the World Issue 1 UAM-05LP-T301/C PL d, Cat. 3, SIL 2, Type 3 Distributed by

Small, light...... and user-friendly! over a Wide Range Dual Mode Master-Slave Function Encoder over a Wide Range Up to 5 meters of protection zone and 20 meters of warning zone configuration to suit various application requirement. Master-Slave Function Maximum 4 units of UAM can be interconnected for Master-Slave operation when multiple units are required to guard the hazardous area. The system can be controlled by connecting the input and output signals to Master unit only 1. Cable or Connector wiring LED display 1 2 MAX 5 m MAX 20 m Master 1 AGV Slave 2 2 Operating Modes 2 s + 1 2 Simultaneous s 1 It is not possible to control the actuators via master-slave bus communication Data via Ethernet Compact design: 95 x 80 x 80 mm, 0,8 Kg SD card for Configuration Expands The Range of Safety Applications Collision Prevention Presence Detection Intrusion Detection SAFETY LEVEL TYPE 3 SIL 2 PL d - Cat. 3 Dual Mode UAM can simultaneously protect two hazardous areas. Separate OSSD signals are triggered for the respective protection zones making it possible to guard two machines with a single UAM. 1 2 Data via Ethernet Measurement data can be acquired via Ethernet with status of input/output signals and cyclic redundancy check code. Also supports command in SCIP2.0 protocol. Encoder In AGV applications, area is switched depending on the vehicle's speed. Speed and direction of travel provided via encoders are constantly monitored to switch the area and stop the A VG during abnormal travel. High Speed Medium Speed Low Speed AGV SD card for Configuration 1 2 Configuration data can be saved in a SD card which in turn can be used for configuring the UAM without connecting it to a PC. The feature is useful while replacing the UAM or configuring multiple units with the same settings. Ethernet (TCP/IP) Distance data Intensity data and output status CRC... Settings data Configuration can be also done via USB connection from a PC 32 safety area patterns to accommodate the AGV travel path for collision prevention Detects humans or objects entering the hazardous area Detects access into critical zone

Technical Features Quality and Reliability Detection property Range Range Distance Tolerance 2 Detection Capability Detection Range Minimum Detectable Width Scan Frequency Area Pattern Element Optics Wave Length Safety Class Safety Level Functional Safety PFHd Housing Power Supply Current Supply Interface Environmental Resistance Bump Outdoor Operation Altitude Response Time Size Weight Case Material Connection Cable Normal (without load) Max. (with load) OSSD1/2 (Safety) OSSD3/4 (Safety) WARNING 1/2 (Non-Safety) RES_REQ 1 RES_REQ 2 MUT_OUT 1 MUT_OUT 2 Area pattern 32 (5 s x 2 Channels) EDM1/EDM2 MUTING1/MUTING2 MUTING3/MUTING4 OVERRIDE1 OVERRIDE2 RESET1/RESET2 ENC_A1/ENC_A2 ENC_B1/ENC_B2 Configuration Data output Operating Temperature Storage Temperature Humidity Storage Humidity Surrounding Intensity 4 Vibration Max: 5 m Max: 20 m (Non-safety) 1 +100 mm From Black-Reflector Sheet (1.8 ) to Retro-Reflector Sheet 30 mm Max: 1,8 m) 50 mm Max: 3,0 m) 70 mm Max: 5,0 m) 150 mm (Max: 5,0 m) 30 ms (Rotational Speed: 2000 rpm) Max 32 patterns for safety and 64 patterns for non-safety OFF 60 ms 510 ms ON 270 ms 510 ms Pulsed Laser Diode 905 nm Class 1 Laser Type 3 (IEC 61496-1, IEC 61496-3) SIL 2 (Tipo B, HFT=1) (IEC61508) 7.8 10-8 (T1 = 20 year) (When master slave function is not in use) 1.6 10-7 (T1 = 20 year) (When master slave function is in use) 80,0 mm (W), 80,0 mm (D), 95,0 mm (H) (without cable) 0,8 kg IP65 Body : Aluminum / Optical Window : Polycarbonate UAM-05LP-T301: 3 m cable, UAM-05LP-T301C: Pigtail with connector 24 Vcc ±10 (when operation using converter power supply) 24 Vcc -30 / 20 (when operation using battery) 6 W 50 W type (High side SW) current: Max. 500 ma 3 Leak current: Max. 1 ma AWG: 26 Load tolerance (L/R = 25 ms, C = 1 μf) type (High side SW) current: Max. 250 ma 3 Leak current: Max. 1 ma AWG: Load tolerance (L/R = 25 ms, C = 1 μf) type (PNP Transistor) current: Max. 200 ma 3 Leak current: Max. 1 ma AWG: Impedance: 4,7 kω AWG: USB2.0 (USB micro type-b connector) Ethernet 100 BASE-TX (Water proof connector) Da -10 a +50º C (No freezing) Da -25 a +70º C (No freezing) 95% RH with no condensation 95% RH with no condensation Less than 1500 lx Frequency range: 10 55 Hz Sweep rate: 1 octave/min Amplitudine: 0,35 mm ±0,05 mm Acceleration: 98 m/s 2 (10 G) Pulse duration: 16 ms Not permitted Below 2000 m 1 Distance when reflectance of the object is 90% or above 2 Additional distance of 200 mm is needed when the UAM is working under high reflective background 3 Total current supply of OSSD output and output should be below 1.0 A 4 When the light sources are located at >=5º from the detection plane of UAM www.reersafety.com

Part Numbers A Versatile Range for Safety Applications Main unit Extension cable without connector UAM-05LP-T301 1350100 Includes CD-ROM with (cable) Safety Laser Scanner configurator software and UAM-05LP-T301C 1350101 manual (connector) Lenght: 10 m UAM-5C10 1350130 Lenght: 20 m UAM-5C20 1350131 Extension cable with connector Connection cables Lenght: 2 m UAM-5C02C 1350132 Lenght: 5 m UAM-5C05C 1350133 UAM T301C requires Lenght: 10 m UAM-5C10C 1350134 one cable Lenght: 20 m UAM-5C20C 1350135 Micro USB cable (1 m) UAM-MUSB 1350140 UAM configuration cable Ethernet cable (3 m) UAM-ENET 1350141 Distance data output cable Brackets and Spares Base mounting bracket UAM-BK03 1350110 Rear mounting bracket UAM-BK04 1350111 Optical lenses protection add-on UAM-BK05 1350112 Optical window protection Optical head spare UAM-W002 1350120 Replacement head unit (only to be fitted by approved personnel)* Mosaic/AD SR1 Adapter Pull-down resistor (2,2 kω) MPD 1350150 For the use of the Scanner with Mosaic Safety Controller or AD SR1 Safety Interface * Attention: After replacement of the Head Unit a calibration of the laser scanner is required (calibration software included with the scanner). Please contact ReeR After Sales Team for more information (aftersales@reer.it) Easy Configuration of Complicated s User Friendly Interface Before settings After settings Simple user interface to configure even a complicated zone by simultanously viewing the measurement data. s can be configured with 3 different methods

External Diagrams The Smallest Size in the World Main unit UAM-05LP-T301 (cable) UAM-05LP-T301C (connector) Water proof connector Detection angle Power cable 9 9 Power cable (300) 17 33 21 80 80 66 134 150 29,5 15 86,6 (Detection plane) 30 15 60 15 Fixing with Base mounting bracket 50,6 50,6 (Detection plane) 116 Fixing with Rear mounting bracket φ5,3 29.5 32 68 4x M5 depth 8 121 Detection angle 1050 Detection angle 110 130 103,7 61,2 29,5 121 60 3-φ5,3 50,6 USB 122 WARNING 2 IP reset switch OSSD 3/4 INTERLOCK 2 Ethernet (10) 95 Display OSSD 1/2 WARNING 1 INTERLOCK 1 67,4 (Detection plane) Ethernet SD Card (60)

Wiring Diagrams Wiring example +24 VDC 0 VDC OSSD1 OSSD2 IN_B IN_B IN_C IN_C IN_D IN_D IN_E IN_E WARNING1 WARNING2 RES_REQ RESET Frame ground (Shield wire) R1 and R2 : External equipment (Safety relay, Electromagnetic contactor) S1: Interlock reset switch 1: Refer to user s manual for details on area switching R1 R2 S1 1 Color Signal Function Description AWG Power Power 22 22 26 26 Brown Blue Red Yellow Red/Black Yellow/Black Purple Gray White Pink Green Purple/Black Gray/Black White/Black Pink/Black Green/Black Yellow/Green Yellow/Blue Orange Orange/Black White/Blue (TP) White/Red (TP) Shield wire +24 VDC 0 VDC OSSD1 OSSD2 OSSD3/ WARNING1 OSSD4/ WARNING2 IN_B/ MUTING3 IN_C/OVERRIDE1/ ENC1_A IN_D/MUTING1/ ENC1_B IN_E/EDM1 IN_B/ MUTING4 IN_C/OVERRIDE2/ ENC2_A IN_D/MUTING2/ ENC2_B IN_E/EDM2 RESET1 RESET2 RES_REQ1/ MUT_OUT1 RES_REQ2/ MUT_OUT2 RS 485 + RS 485 - FG Com Com Power Supply: 24 VDC Power Supply: 0 VDC zone output 1 zone output 2 zone output 3/ zone output 1 zone output 4/ zone output 2 Area Switching A Area Switching B/ Muting input 3 Area Switching C/Override input 1/Encoder input 1_A Area Switching D/Muting input 1/Encoder input 1_B Area Switching E/ External device monitoring 1 Area Switching A invert Area Switching B invert/ Muting input 4 Area Switching C invert/ Override input 2/Encoder input 2_A Area Switching D invert/ Muting input 2/Encoder input 2_B Area Switching E invert External device monitoring 2 Reset input 1 Reset input 2 RES_REQ 1 : Request output 1 MUT_OUT 1 : Muting state output 1 RES_REQ 2 : Request output 2 MUT_OUT 2 : Muting state output 2 Communication Protocol RS 485 Communication Protocol RS 485 Frame ground / circuit OSSD output circuit OSSD/ output is output type Other circuit RES_REQ1, RES_REQ2, MUT_OUT1, MUT_OUT2 output circuit +24 V +24 V Control circuit OSSD1 OSSD2 OSSD3/WARNING1 OSSD4/WARNING2 Control circuit circuit RES_REQ1/MUT_OUT1 RES_REQ2/MUT_OUT2 Area input, EDM1, EDM2, RESET1, RESET2, MUTING1, MUTING2, MUTING3, MUTING4, OVERRIDE1 and OVERRIDE2 Use with and AD SR1 For a correct use with Mosaic Safety Controller or AD SR1 Safety Interface, the use of a Pull Down Resistor is necessary. Model MPD, Part Number 1350150 Control circuit INPUT 0 V

Safety. Detection. Control. ReeR SpA Via Carcano, 32 10153 Torino Italy T +39 011 248 2215 F +39 011 859 867 www.reersafety.com info@reer.it Leggere attentamente il Manuale di Istruzioni prima dell utilizzo I prodotti descritti in questa brochure si intendono per utilizzo in applicazioni specifiche Per informazioni e quesiti tecnici rivolgersi presso i nostri uffici More than 50 years of quality and innovation Founded in Turin, Italy in 1959, ReeR distinguished itself for its strong commitment to innovation and technology. A steady growth throughout the years allowed ReeR to become a point of reference in the safety automation industry at a worldwide level. The Safety Division is in fact today a world leader in the development and manufacturing of safety optoelectronic sensors and controllers. ReeR is ISO 9001, ISO 14001 and BS OHSAS 18001 certified. Rev. 1.3 May 2018 8946302 Brochure Hokuyo UAM English Printed in Italy ReeR SpA does not guarantee that product information in this catalogue are the most current available. ReeR SpA reserves the right to make changes to the products described without notice and assumes no liability as a result of their use or application. Our goal is to keep the information on this catalogue timely and accurate, however ReeR SpA accepts no responsibility or liability whatsoever with regard to the information on this catalogue. Reproduction is not authorised, except with the expressed permission of ReeR SpA.