Operating Instructions Sartorius

Similar documents
Operating Instructions. Sartorius. Description of the Interface for EA, EB, GD, GE and TE Balances/Scales

Sartorius Comparator. Interface Description for the CC Model Series

VA-6 kg, VA-12 kg, VA-30 kg

Sartorius Talent Sartorius Gem, Gold Electronic Analytical and Precision Balances and Precious Metal Scales

Sartorius Economy Series Sartorius Express Series

The Sartorius Talent Series Your access to talented weighing technology

Sartorius Counting Scales CB Models Electronic Precision Scales

Operating Instructions. Controller for Automatic Mass Comparators from Software Version 1.22 for CC...- L / CCE...- L Model

Sartorius Element Series

Application Guide for the Secura, Quintix and Practum Series

GSE Scale Systems M660 CUSTOM TRANSMIT

Sartorius Element Series

Visit for discount prices on Acculab Scales SVI SERIES PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI-10A SVI-20B SVI-50C SVI-100E SVI-200F

Operating Instructions. ALC Models. Electronic Analytical Balances and Precision Scales

Summit Series. Operation Manual Rev. A g. 0.0 g g TARE

Sartorius CP Gem plus Series

Application Guide for the Secura, Quintix and Practum Series of Models

Sartorius PMA.Quality PMA7501, PMA

USB Interface Instruction Manual

TIME MACHINE Data Formats (Sep jkuo: extracted from the TIME MACHINE user manual)

Operating instructions METTLER TOLEDO BD balances

Practum. Start Weighing Right.

CONTENTS. PRECAUTIONS Introduction Installation... 7

The New Practum. Start Weighing Right.

AL-Series Analytical and Toploading Balances

MT-SICS. Reference Manual for

Advanced Test Equipment Rentals ATEC (2832)

Interface description METTLER TOLEDO Spider and Spider S scales

MWP SERIES. High Precision

NB/NHB Precision Balance

The New Practum. Start Weighing Right.

RS 232 Interface. RS 232 is the Serial interface on the PC. Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3

Sartorius MP8 Series Balances and Scales

EXPERIMENT 8: Introduction to Universal Serial Asynchronous Receive Transmit (USART)

Digital Weight Indicator Setup / Operation Manual

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

PS-IN202 Weighing Indicator User Manual

Sartorius Genius Series

Brief Instructions. Sartorius PMA List of Menu Settings

EXPERIMENT 7: Introduction to Universal Serial Asynchronous Receive Transmit (USART)

Station 2. Inverter. PU connector (Note1)

Sartorius Weigh Cells

Operating instructions. METTLER TOLEDO Bidirectional Data Interface for the J series balances. Option 018

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Industrial Weighing Systems

Copyright Western Scale Co. Limited. All rights reserved.

INTRODUCTION INSTALLATION

This document hosted by: 10. OPTIONS

Sartorius Research. R 160 P Electronic Semi-Microbalance

Sartorius Basic plus. Electronic Semi-micro-, Analytical and Precision Balances Installation and Operating Instructions

Oxford E Series. Instruction Manual

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Nimbus NBL Series (P.N , Revision 3.00, Effective Aug 2017)

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

Precision Balance W3200 Series Operating Manual

DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES

Marketing Information Bluetooth Wireless Interface

USER MANUAL FOR Analytical Balances. (Software Revision: 2.43 above)

Adventurer TM Balances Instruction Manual

Sartorius TS 6100B, TS 12 Electronic Over/Under Scales Installation and Operating Instructions

InfoTag KE28xx Communications for 186 CPU Firmware Version 4

LANCNC FTP LAN network data server for CNC Controls

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2)

Sartorius YDP 03-0CE. Data Printer Operating Instructions

X-Series System Manual Part 7: Interfaces and data communication

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL

Addendum to TI-500E Plus Setup/Operation Manual For Time, Date, Print Formats Option

A GUIDE TO RS-232 COMMUNICATION WITH FX PLCS

Digital Indicator. Revision 1.6 March 15, Transcell Technology, Inc. Contents subject to change without notice.

Sartorius CC30002, CC50002 Electronic Mass Comparator

Sartorius Extend Series Sartorius Gem and Gold Extend Series Electronic Analytical and Precision Balances and Precious Metal Scales

Select a Data Communication Interface

MK D Imager Barcode Scanner Configuration Guide

Operating and Installation instructions Filling with COUNT+ METTLER TOLEDO Compact scales BBA442 and BBK442 Terminals IND445 and IND449

BBA-Series Precision Balances

STEPware-100 Operations Manual

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Beijer Electronics AB 2000, MA00453,

Digital Weight Indicator Setup / Operation Manual

VI- Series VIR- Series. Instruction Manual. for Models: VI-1mg VI-200 VI-2400 VI-3mg VI-350 VI Rev. B

SIN-11-USB USERS GUIDE SIN-11-USB USERS GUIDE

Precision platforms for hazardous areas

English page 3 In cases involving questions of interpretation, the German-language version shall prevail.

GxP-compliant Printing and Archiving of Initial Weights and Related Weighing Data. White Paper

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

Scout Series Balances - STX Instruction Manual

Datapanel. VT100 Terminal Emulator for Datapanels. Operator Interface Products. User's Manual

Sartorius DocuClip & Docu-pH Meter. The new standard for reliability in electrochemical analysis

GENIUS Innovative in Function and Design

TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual

Addmaster Corporation

Introduction Page 1. Power Supply Requirements & Hardware Options Page 2. External Connectors (Functions & Pinouts) Page 2

Operating Instructions. Sartorius AW Series. Electronic Analytical and Precision Balances

Operating Manual. Sigma Counting Scale. CTG-9850 Series (AC Powered) Issue #9 3/ by Fairbanks Scales Inc. All rights reserved

Operating Instructions

The New Sartorius CP-Series

Transcription:

Operating Instructions Sartorius Description of the Interface for GD, GE and TE Balances/Scales

Contents Intended Use 2 Contents 2 Intended Use 2 Configuring the Interface Parameter Settings (Menu) 3 Data Output Functions 3 Printing a Data Record 5 Interface Description 5 Data Output Format 9 Data Input Format 12 Cabling Diagram The interface can be used to connect the balance/scale to a computer (or other peripheral device). You can use a computer to change, start and monitor balance/scale functions and applications. Available Features Type of interface: Serial interface Operating mode: Full duplex Standard: RS-232 Transmission rates: 150, 300, 600, 1,200, 2,400, 4,800, 9,600 baud Parity: Mark, space, odd, even Character format: Start bit, 7-bit ASCII, parity, 1 or 2 stop bits Handshake: 2-wire interface: via software (XON/XOFF) 4-wire interface: via hardware (CTS/DTR) Protocol: SBI (Sartorius Balance Interface) Data output format of the balance/scale: 16 or 22 characters Configuring the Interface Parameter Settings (Menu) Please refer to the installation and operating instructions supplied with your balance/scale. 2

Data Output Functions Printing a Data Record Purpose You can generate a printout of weights as well as other measured values and IDs for documentation purposes. You can format the printout to meet individual requirements. Available Features Print individual values Line format: You can configure a data ID code of up to 6 characters for each of the values printed; this data ID code is printed at the beginning of a line Printouts are generated automatically or by pressing p, depending on or regardless of the balance/scale stability parameter. You can have the following values output automatically when using the application programs if menu code 7.1. 2 (printout with data ID codes) is configured: Second tare memory: last net value Counting: Reference weight for one piece (average piece weight) Weighing in percent: Reference weight for the percentage selected Averaging: Result of measurement 3

Examples of Data Records: Printout without Data ID Codes (Menu Code 7.1. 1): The value currently displayed is printed (weight or calculated value with unit) + 1530.0 g Weight in grams + 58.562 ozt Weight in Troy ounces + 253 pcs Piece count + 88.2 % Percentage + 105.8 o Calculated value Printout with Data ID Codes (Menu Code 7.1. 2): The current value displayed can be printed with a data ID code of up to 6 characters at the beginning of a line. You can use this data ID code, e.g., to designate a weight readout as a net weight (N) or a calculated value as a quantity (Qnt). N + 153.0 g Current net weight N1 + 153.0 g Current net weight (with data in 2nd tare memory) T1 + 10.2 g Value in 2nd tare memory Qnt + 253 pcs Calculated quantity (piece count) Prc + 88.2 % Calculated percentage Res + 153.0 g Calculated result Print Application Parameters (Menu Code 7.1. 2): You can generate a printout of one or more of the values configured for initialization of an application as soon as you initialize the balance/scale. wref + 1.432 g Counting: average piece weight Wxx% + 120.12 g Weighing in percent: reference weight for the selected percentage Auto Print (Menu Code 6.1. 3 or 6.1. 4): You can have the weight readout printed automatically. The display update interval depends on the operating status of the balance/scale and on the balance/scale model. N + 153.9g Net weight Stat Display blank Stat L Display underload Stat H Display overload 4

Interface Description Factory Settings Transmission rate: 1,200 baud (5. 1. 4) Parity: Odd (5. 2. 3) Stop bits: 1 stop bit (5. 3. 1) Handshake: Hardware, 1 character after CTS (5. 4. 3) Protocol: Standard SBI (5. 5. 1) Print manually/automatically: Manual after stability (6. 1. 2) Line format: For other applications (7. 1. 2) Data Output Format You can output the values displayed in the measured value line and the weight unit with or without a data ID code. Example: Without data ID code + 253 pcs Example: With data ID code Qnt + 253 pcs Configure this parameter in the Setup menu (Menu: Printout format 7.1.1 or 7.1. 2). The output without data ID code has 16 characters; with data ID code, 22 characters. 5

Output Format With 16 Characters Display segments that are not activated are output as spaces. Characters without a decimal point are output without a decimal point. The following characters can be output, depending on the characters displayed on the balance/scale: Normal Operation Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 + * D D D D D D D D * U U U CRLF or........ * * * or * * * * * * * * * or 0 0 0 0 0 0 *: Space 0: Zero D: Digit or displayed character CR: Carriage return U: Unit symbol LF: Line feed. : Decimal point Special Codes Position 1 2 3 45678910111213141516 * * * * * * * * * * * * CR LF or H * or L * *: Space H: Overload : Final readout mode L: Underload Error Codes Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 * * * E * * * # # # * * * * CR LF *: Space # # #: Error code number 6

Example: Data output + 1255.7 g at stability Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 + * * * 1 2 5 5 7 * g * * CR LF Position 1: Position 2: Position 3 10: Position 11: Position 12 14: Position 15: Position 16: Plus or minus sign or space Space Weight with a decimal point; leading zeros = space Space Unit symbol or space Carriage return Line feed Output Format with 22 Characters When data with an ID code is output, the ID code consisting of 6 characters precedes the data with the 16-character format. These 6 characters identify the following value. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 I I I I I I + * D D D D D D D D * U U U CRLF * * * * * * * * * * * * * * * * 0 0 0 0 0 0 I: ID code character U: Unit symbol *: Space CR: Carriage return D: Digit or displayed character LF: Line feed. : Decimal point 0: Zero 7

Special Codes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 S T A T * * * * * * * * * * * * * * CRLF H * L * *: Space H: Overload : Final readout mode L: Underload (readout has not yet stabilized) Error Codes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 S T A T * * * * * E r r * # # # * * * * CRLF *: Space # # #: Error code number ID code characters Stat N N1 Qnt Prc Res wref Wxx% Meaning Status Net N Net N1 (when data in the 2nd tare memory) Counting: quantity (piece count) Weighing in percent: percentage Calculation, averaging: result Automatic printout: average piece weight Automatic printout: reference percentage weight 8

Data Input Format You can connect a computer to your balance/scale to send commands via the balance/scale interface port to control balance/scale functions and applications. A control command can have up to 4 characters. Each character must be transmitted according to the settings configured in the Setup menu for data transmission. Format for Control Commands Format : Esc! CR LF Esc: Escape!: Command char. CR: Carriage return (optional) LF: Line feed (optional) Command character! Meaning K Weighing mode 1 L Weighing mode 2 M Weighing mode 3 N Weighing mode 4 O Block keys P Print R Release keys S Restart T Tare and zero (combined) U Tare ( tare only ) V Zero W External calibration/adjustment (depends on menu setting) 9

Synchronization During data communication between the balance/scale and an on-line device (computer), messages consisting of ASCII characters are transmitted via the interface. For error-free data communication, the parameters for baud rate, parity, handshake mode and character format must be the same for both units. You can set these parameters in the Setup menu so that they match those of the on-line device. You can also define parameters in the balance/ scale to make data output dependent on various conditions. The conditions that can be configured are described for each of the application programs. If you do not plug a peripheral device into the balance/scale interface port, this will not generate an error message. Handshake The balance/scale interface (Sartorius Balance Interface = SBI) has transmit and receive buffers. You can define the handshake parameter in the Setup menu: Hardware handshake (CTS/DTR) Software handshake (XON, XOFF) Hardware Handshake With a 4-wire interface, 1 or 2 more characters can be transmitted after CTS. 10

Software Handshake The software handshake is controlled via XON and XOFF. When a device is switched on, XON must be transmitted to enable any connected device to communicate. Activating Data Output You can define the data output parameter so that output is activated either when a print command is received or automatically and synchronously with the balance/scale display (see application program descriptions and auto-print setting). Data Output by Print Command The print command can be transmitted by pressing p or by a software command (Esc P). Automatic Data Output In the auto print operating mode, data is output to the interface port without a print command. You can choose to have data output automatically and synchronously with the balance/scale display at defined print intervals with or without the stability parameter. Whichever parameter you select, the data will be output as the readouts appear on the balance/scale display. The display update frequency depends on the setting for Adapting the Filter (code 1.1.x.). When the auto print menu code is activated, this function starts immediately after the balance/scale has been turned on. 11

Pin Assignment Chart Please refer to the installation and operating instructions supplied with your balance/scale. Cabling Diagram Diagram for interfacing a computer or different peripheral device to the balance/scale using the RS-232/V24 standard and cables up to 15 m (~50 ft.) long Balance/Scale Peripheral Device V24 PC 25 pol. or 9 pol. 2 3 20 4 3 2 5 8 6 6 7 5 Type of cable: AWG 24 specification 12

Sartorius AG Weender Landstrasse 94 108 37075 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius.com Copyright by Sartorius AG, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius AG reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. Status: July 2003, Sartorius AG, Goettingen, Germany Printed in Germany on paper that has been bleached without any use of chlorine W8A000 GD, GE, TE KT Publication No.: WTE6003-e03071