Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25

Similar documents
Manual VIPA System 500S SPEED7 - CPU

VIPA System 200V. IM Manual

Manual VIPA HMI CC 03

VIPA Accessories. Teleservice module 900-2C610 Manual

Manual. VIPA Accessories Teleservice module TM-E 900-1E630. Order-No.: VIPA HB39E_TME Reference: RE_900-1E630 Rev. 09/11

SIMATIC NET PG/PC - PROFIBUS CP Preface. Description of the device 1. Software installation 2. Hardware installation 3.

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

VIPA HMI. Text Display TD 03 Manual

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en

Installation Instructions VIPA FM355 / R355. 4/8-Channel Controller Module for Siemens S7-300 and Vipa System 300V /10.

VIPA Accessories. Teleservice module 900-2H611 Manual

VIPA HMI. Commander Compact CC 03 Manual

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

Manual. VIPA Accessories Teleservice module TM-E 900-1E650. Order-No.: VIPA HB39E_TME Reference: RE_900-1E650 Rev. 09/11

VIPA Accessories UZ00 Manual

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

VIPA System 300. PS 307-1xA00 Manual. HB130 PS 307-1xA00 en PS

VIPA System 100V. CPU Manual

VIPA Accessories. Teleservice module 900-2E651 Manual

Manual. VIPA System 300S SPEED7 - CPU 317-2AJ12. Order No.: VIPA HB140E_CPU Reference: RE_317-2AJ12 Rev. 09/11

SSW5/USB. S5-PLC to USB converter cable US US13. User Manual. Edition 2 / / HW1 and higher

VIPA SPEED7 Library. OPL_SP7-LIB SW90HS0MA V Manual. HB00 OPL_SP7-LIB SW90HS0MA V en Block library - EtherCAT Communication

VIPA Accessories. Teleservice module 900-2H681 Manual

VIPA HMI. Touch Panel 610-3B2J0 Manual

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Manual. VIPA System 100V SM-PB. Order No.: VIPA HB100E_SM-PB Rev. 06/14

VIPA HMI. Touch Panel 605-1B1E0 Manual

VIPA System 300S. SPEED7 - CPU 314-2AG13 Manual

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

VIPA HMI. Touch Panel 608-3B4G1 Manual

PCAN-MicroMod Digital 1 & 2 Application-specific PCAN-MicroMod Motherboard. User Manual V1.10.0

VIPA System SLIO. PS-CM Manual. HB300 PS-CM en PS 007-1ABxx, CM 001-1BAxx.

VIPA System SLIO. IM 06x-1xA00 Manual. HB300 IM 06x-1xA00 en Interface module Line extension - IM 06x.

CPCI-PS24 24V-Power Supply

AO561 Analog Output Module

MC-12 Software Installation Instructions

PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

AI561 Analog Input Module

Manual VIPA CP443. Order-no.: VIPA HB102E Rev. 01/35. Subject to change to cater for technical progress.

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Accessory GP-EXT. EXTERNAL USB PRINTER User's Manual

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

MC 11 EB-2 Power supply cabinet with external bus, AC version

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

VIPA System 300S CP 342-1DA70 Manual

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

TF501, TF521 Terminal Bases

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

VIPA System 300S. CP 342-1DA70 Manual. HB140 CP 342-1DA70 en SPEED7 CP 342S-DP.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Manual Version: V1.00. Video Decoder Quick Guide

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

ewon Flexy 2 Serial Ports Ext. Card FLA 3301

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

VIPA HMI. Touch Panel 62F-DCB0 Manual

Kvaser Mini PCI Express User s Guide

VIPA System SLIO CPU 015-CEFPR00 Manual

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

VIPA System 300S. SPEED7 - CPU SC 314-6CG13 Manual

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

Manual. VIPA System 300V CP 341-1CH01. Order No.: VIPA HB130E_CP Reference: RE_341-1CH01 Rev. 08/43

CP 5711 SIMATIC NET PG/PC - PROFIBUS CP Preface. Description of the device. Software installation. Hardware installation.

ST (6ES7132-6FD00-0BB1)

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DI572 Digital Input Module

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

C9900-P223 and C9900-P224

VIPA System 300S. SPEED7 - CP 342-1CA70 Manual

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

Kvaser Leaf Light v2 User s Guide

CU Compact-Flash card adapter for USB. Version: 1.0 Date:

VIPA HMI. Touch Panel 62M-JEE0 Manual

DI561 Digital Input Module

DO 16xDC24V 1A 1L DO 16xDC24V F SM322 2L F VIPA 322-1BH VIPA 322-1BF01. DO 32xDC24V 1A 1/3L+

CM597 Ethernet Communication Module

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

Allen-Bradley Motors

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Manual. VIPA HMI Touch Panel 612-3B2I0. Order no.: VIPA HB160E_TP Reference: RE_612-3B2I0 Rev. 09/09

TU531, TU532 Terminal Unit

VIPA System SLIO. CPU 013-CCF0R00 Manual. HB300 CPU 013-CCF0R00 en SPEED7 CPU 013C.

CU port USB 2.0 hub. Version: 1.1 Date:

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

BNI USB A501. USB IO-Link Master User's Guide. english

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

Transcription:

Manual VIPA Accessories USB-MPI adapter 950-0KB31 Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 This manual is relevant for: Product Order number as of state: HW SW USB-MPI adapter VIPA 950-0KB31 01 V115

Leeichen

Manual VIPA Accessories The information contained in this manual is supplied without warranties. The information is subject to change without notice. Copyright 2008 VIPA, Gesellschaft für Visualisierung und Prozessautomatisierung mbh Ohmstraße 4, D-91074 Herzogenaurach, Tel.: +49 (91 32) 744-0 Fax.: +49 (91 32) 744-144 EMail: info@vipa.de http://www.vipa.de Hotline: +49 (91 32) 744-114 All rights reserved Disclaimer of liability The contents of this manual were verified with respect to the hard- and software. However, we assume no responsibility for any discrepancies or errors. The information in this manual is verified on a regular basis and any required corrections will be included in subsequent editions. Suggestions for improvement are always welcome. Trademarks VIPA is a registered trademark of VIPA Gesellschaft für Visualisierung und Prozessautomatisierung mbh. Microsoft, Windows and Windows Logo are either registered trademarks or trademarks of Microsoft Cooperation in the USA and/or other countries. Any other trademarks referred to in the text are the trademarks of the respective owner and we acknowledge their registration. Subject to change to cater for technical progress.

Contents Manual VIPA Accessories About this manual This manual describes the PC-AG adapter with USB-MPI link from VIPA. Here you may find every information to operate the adapter between PC and CPU. Overview Chapter 1: Hardware description In this chapter the hardware of the USB-MPI adapter is more described. The chapter closes with the technical data. Chapter 2: Deployment Here the deployment and the firmware update of the USB-MPI adapter are described. Contents User considerations... 1 Safety information... 2 Chapter 1 Hardware description... 1-1 Safety Information for Users... 1-2 Properties... 1-3 Structure... 1-4 Technical Data... 1-6 Chapter 2 Deployment... 2-1 Establishing a connection... 2-2 Installing the USB driver... 2-3 Setting the PLC programming software... 2-4 Firmware update... 2-6 Subject to change to cater for technical progress.

Manual VIPA Accessories User considerations User considerations Objective and contents This manual describes the USB-MPI adapter from VIPA. It contains a description of the structure, the deployment and the technical data. Target audience The manual is targeted at users who have a background in automation technology. Structure of the manual The manual consists of chapters. Every chapter provides a self-contained description of a specific topic. Guide to the document The following guides are available in the manual: an overall table of contents at the beginning of the manual an overview of the topics for every chapter Availability The manual is available in: printed form, on paper in electronic form as PDF-file (Adobe Acrobat Reader) Icons Headings Important passages in the text are highlighted by following icons and headings: Danger! Immediate or likely danger. Personal injury is possible. Attention! Damages to property is likely if these warnings are not heeded. Note! Supplementary information and useful tips. HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 1

Safety information Manual VIPA Accessories Safety information Applications conforming with specifications The System USB-MPI adapter is constructed and produced for: VIPA CPUs 11x, 21x, 31x, 51x und S7-300/400 from Siemens communication and process control industrial applications operation within the environmental conditions specified in the technical data Danger! This device is not certified for applications in in explosive environments (EX-zone) Documentation The manual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the components described in this manual: Modification to the process control system should only be carried out when the system has been disconnected from power! Installation and modifications only by properly trained personnel The national rules and regulations of the respective country must be satisfied (installation, safety, EMC...) Disposal National rules and regulations apply to the disposal of the unit! 2 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25

Manual VIPA Accessories Chapter 1 Hardware description Chapter 1 Hardware description Overview In this chapter the hardware of the USB-MPI adapter is more described. The chapter closes with the technical data. Contents Topic Page Chapter 1 Hardware description... 1-1 Safety Information for Users... 1-2 Properties... 1-3 Structure... 1-4 Technical Data... 1-6 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 1-1

Chapter 1 Hardware description Manual VIPA Accessories Safety Information for Users Handling of electrostatic sensitive modules VIPA modules make use of highly integrated components in MOS- Technology. These components are extremely sensitive to over-voltages that can occur during electrostatic discharges. The following symbol is attached to modules that can be destroyed by electrostatic discharges. The Symbol is located on the module, the module rack or on packing material and it indicates the presence of electrostatic sensitive equipment. It is possible that electrostatic sensitive equipment is destroyed by energies and voltages that are far less than the human threshold of perception. These voltages can occur where persons do not discharge themselves before handling electrostatic sensitive modules and they can damage components thereby, causing the module to become inoperable or unusable. Modules that have been damaged by electrostatic discharges can fail after a temperature change, mechanical shock or changes in the electrical load. Only the consequent implementation of protection devices and meticulous attention to the applicable rules and regulations for handling the respective equipment can prevent failures of electrostatic sensitive modules. Shipping of modules Modules must be shipped in the original packing material. Measurements and alterations on electrostatic sensitive modules When you are conducting measurements on electrostatic sensitive modules you should take the following precautions: Floating instruments must be discharged before use. Instruments must be grounded. Modifying electrostatic sensitive modules you should only use soldering irons with grounded tips. Attention! Personnel and instruments should be grounded when working on electrostatic sensitive modules. 1-2 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25

Manual VIPA Accessories Chapter 1 Hardware description Properties Overview The PC may be connected via USB to the MPI interface of the CPU by means of the PC-AG-Adapter. Here no slot is occupied in the PC, this means the adapter is suitable for computers, which are not expandable like e.g. notebooks. To connect a PC there is a USB-B jack integrated. The connection of the CPU happens by the cable of the adapter with a MPI plug on its end. In the connected condition the adapter is power supplied by USB. A driver is necessary for operation, which serves for a virtual COM port via USB. The adapter may be accessed via this interface by your PCL programming tool. Note! Maximally one PC-AG adapter may be connected to your PC! Properties PC-AG adapter with USB-MPI link USB-B jack for USB 1.1/2.0 Cable with RS485 plug (up to 1.5Mbit/s) Automatic bus profile recognition Compatible to WinPLC7 from VIPA and Siemens SIMATIC manager Order data Type Order number Description USB-MPI VIPA 950-0KB31 USB-MPI adapter HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 1-3

Chapter 1 Hardware description Manual VIPA Accessories Structure USB-MPI adapter 950-0KB31 MPI USB-MPI Adapter [1] LEDs [2] Cable with MPI plug to connect the CPU [3] USB-B jack to connect the PC 1 Power Active Error 2 X 2 3 4 USB VIPA 950-0KB31 3 Components LEDs For diagnostics the PC-AG adapter has 3 LEDs integrated: Power green Active green Error red - Meaning PC-AG adapter is not power supplied. PC-AG adapter has started up and ready for communication. PC-AG adapter communicates via MPI interface. - PC-AG adapter is starting up. - Firmware is transferring. - Firmware is flashed. An error has occurred, which requires a restart of the PC-AG adapter. Disconnect the adapter from the MPI jack of the CPU and reconnect it. on: off: flashes (1Hz): flashes (8Hz): irrelevant: - 1-4 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25

Manual VIPA Accessories Chapter 1 Hardware description USB-B jack There is a USB-B jack integrated for the connection of the PC-AG adapter to your PC. As soon as the PC-AG adapter is connected to an active PC the adapter is power supplied. The USB-B jack has the following assignment: 2 1 3 4 USB-B jack: Pin Assignment 1 VCC 2 DM 3 DP 4 GND VIPA USB cable In the scope of delivery there is a USB cable. The PC-AG adapter may be connected to the USB-A slot of your PC by means of this cable. The cable has a length of 1.8m. MPI plug (RS485) The PC-AG adapter hat a cable integrated with a 9pin plug on its end. The 9pin plug has the following assignment: 6 7 8 9 1 2 3 4 5 Pin Assignment Description 1 n.c. not used 2 M24V not used 3 RxD/TxD-P (Line B) Data line B (In-/Output) 4 RTS_AS RTS output signal of the CPU. The signal is "1", as soon as the CPU sends. 5 M5V Reference potential of the MPI interface for the signals RTS_AS. 6 n.c. not used 7 P24V not used 8 RxD/TxD-N (Line A) Data line A (In-/Output) 9 RTS_PG RTS output signal of the PC-AG adapter. The signal is "1", as son as the PC-AG adapter sends. HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 1-5

Chapter 1 Hardware description Manual VIPA Accessories Technical Data USB-MPI adapter Electrical Data Power supply Power consumption VIPA 950-0KB31 DC 5V via USB interface 90mA (max.) Interfaces to AG RS485 - Transfer rate up to max. 1.5MBit/s to PC USB-B (USB 1.1/2.0) - Transfer rate up to max. 12MBit/s EMC Noise emission Limit value class B according to EN55022 Noise immunity on signal lines 2 kv (according to IEC 61000-4-4; burst; length > 3m) ESD/Burst according to IEC 61000-4-2 / IEC 61000-4-4 (to level 3) Shockproof according to IEC 60068-2-6 / IEC 60068-2-27 (1G/12G) Radio interference level according to IEC 61000-6-4 Environment conditions Operating temperature 0... +60 C Storage temperature -25... +70 C Relative humidity 5... 95% without condensation Dimensions and Weight Degree of protection IP20 Dimensions (WxHxD) 53 x 100 x 28mm Length MPI cable 1.2m Weight 145g 1-6 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25

Manual VIPA Accessories Chapter 2 Deployment Chapter 2 Deployment Overview Here the deployment and the firmware update of the USB-MPI adapter are described. Contents Topic Page Chapter 2 Deployment... 2-1 Establishing a connection... 2-2 Installing the USB driver... 2-3 Setting the PLC programming software... 2-4 Firmware update... 2-6 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 2-1

Chapter 2 Deployment Manual VIPA Accessories Establishing a connection Overview For operation there is an additional driver necessary, which serves for a virtual COM interface via USB. The driver may be found at "Service" at www.vipa.de. Connect the USB-B slot of the PC-AG adapter with the USB-A slot of your PC by means of the provided USB cable. As soon as the PC-AG adapter is power supplied via USB the adapter starts up and shows the ready state by the "Power" LED. If still no driver is installed, you are now requested to install the driver. After the driver installation the adapter may be accessed by means of the virtual COM port via USB. Connect the MPI jack of your CPU to the mounted MPI cable of the PC-AG adapter. Now the adapter is ready for communication. PC X1 DC 24V + - + - CPU X2 MPI X3 USB MPI USB-MPI Adapter Power Active Error USB cable X 2 3 4 USB VIPA 950-0KB31 USB Hardware precondition For the deployment of the PC-AG adapter a pc is necessary, which has a USB-A interface integrated. Software precondition For the deployment of the PC-AG adapter a Windows operating system and a SPS software package is necessary, which supports the interface of the PC Adapter MPI. For operation there is an additional driver necessary, which serves for a virtual COM port via USB. By selecting this COM port you get access to the PC-AG adapter via USB. 2-2 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25

Manual VIPA Accessories Chapter 2 Deployment Installing the USB driver USB driver For operation of the PC-AG adapter there is the installation of an USB driver necessary. The corresponding driver may be found at "Service" of www.vipa.de respectively at www.ftdichip.com/drivers/vcp.htm. The driver package consists of a driver for the USB hardware binding and a driver which establishes a virtual COM port. Installing hardware driver Depending on the operating system and the USB drivers used before, the installation of the hardware driver may no longer be necessary. Here the installation starts with the hardware wizard to install the virtual COM port (see below). Otherwise the installation takes place after the following approach: Load the ZIP file of the driver and unzip the file to an empty directory. Connect the PC-AG adapter with the provided USB cable and attach this to a free USB-A interface of your PC. The PC-AG adapter is power supplied via USB and shows the ready state by the "Power" LED. Depending on the operating system a dialog window of the hardware wizard is opened to show that a new hardware was found. Negate the access to the "Windows Update" Web side and enter the directory on which the unzipped driver is located. Continue the installation, if a message about a not passed "Windows Logo test" is shown. The hardware driver is installed and this is shown by a corresponding message. Installing virtual COM interface As soon as the hardware driver is installed, the installation of the virtual COM port starts automatically with the hardware wizard. Here proceed with the following approach: Negate the access to the "Windows Update" Web side and enter the directory on which the unzipped driver is located. Continue the installation, if a message about a not passed "Windows Logo test" is shown. The driver for the virtual COM interface is installed and this is shown by a corresponding message. For the virtual COM the number of the next free COM port is used. After installation the driver may be found in the Device Manager as "USB-Serial- Converter". Here also the corresponding COM port, which is assigned to the USB interface, is listed. De-installation For de-installation remove the PC-AG adapter from your PC and start the uninstall routine at Control panel > Software. HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 2-3

Chapter 2 Deployment Manual VIPA Accessories Setting the PLC programming software Overview The PC-AG adapter may be used with each PLC programming software, which supports the interface PC Adapter MPI. Suitable PLC programming software is e.g. WinPLC7 from VIPA or the Siemens SIMATIC manager. In the following the deployment with these two software packages is described. Deployment with WinPLC7 from VIPA Attach the PC-AG adapter via USB to your PC and connect the MPI cable to your CPU. If not already happen switch the power supply of the CPU on. Start WinPLC7 with your project on your PC. Set at the toolbar above "Target: RS232". Click to. A dialog window for setting the serial interface is opened. Set the corresponding COM port, which was established at your PC as virtual COM port by the USB driver installation. Presetting of a transfer rate is not necessary and is ignored when accessing the USB interface. Setting the MPI address If you know the MPI address of your CPU - CPUs of VIPA are delivered with address 2 - the MPI address may be entered at "MPI address of S7-300/400" and a connection may be established by the button [Connect]. If you do not know the MPI address, a connection to the direct to your PC via PC-AG adapter attached CPU may be established by [Direct]. With the button [Accessible nodes] each via MPI reachable station is listed in a dialog window. Here the MPI address of the CPU, direct attached with the PC-AG adapter, is emphasized represented. More about this may be found in the online help of WinPLC7. 2-4 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25

Manual VIPA Accessories Chapter 2 Deployment Deployment with Siemens SIMATIC manager Attach the PC-AG adapter via USB to your PC and connect the MPI cable to your CPU. If not already happen switch the power supply of the CPU on. Start the Siemens SIMATIC manager with your project on your PC. Set at Extras > Set PG/PC interface as Interface parameter assignment "PC Adapter (MPI)". Click to [Properties]. Enter your MPI parameters at the register "MPI". Choose to the register "Local connection". Set the corresponding COM port, which was established at your PC as virtual COM port by the USB driver installation. Presetting of a transfer rate is not necessary and is ignored when accessing the USB interface. Confirm your input with [OK]. Installation of the PC adapter if it does not exist If the PC-Adapter (MPI) is not listed, it may be added with [Select]. Choose at Selection "PC-Adapter" and click to [Install-->]. More about this may be found in the online help of the Siemens SIMATIC manager. HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25 2-5

Chapter 2 Deployment Manual VIPA Accessories Firmware update Overview By means of an update software there is the opportunity to execute a firmware update of your adapter. For the firmware update the PC-AG adapter is to be connected via USB to your PC. The update takes approx. 1 minute. The most current firmware may be found at www.vipa.de. Attention! When installing a new firmware you have to be extremely careful. Under certain circumstances you may destroy the PC-AG adapter, e.g. if the power supply is interrupted during the update. In this case please call the VIPA hotline! Preparation Call www.vipa.de and navigate at "Service" to the area "Firmware updates". At "Firmware for PC-AG-Adapter" the newest firmware for the PC-AG adapter may be found, if available. Download this to your PC. Navigate at "Service" to the area "Software", download the updater software for the PC-AG adapter to your PC and unzip the file. Proceeding Connect your PC via USB to the adapter. The adapter is now power supplied via USB and it shows the ready state by the "Power" LED. Start the downloaded Tool Updater.exe at your PC. Set the corresponding COM interface and click to [Connect]. The "Power" LED on the adapter flashes with 1Hz. Click to [Browse] and navigate to the downloaded firmware file. Start the transfer with [Write]. Display behavior The proceeding of the firmware update is shown at the PC as a moving line. During the transfer of the firmware file into the PC-AG adapter the "Power" LED blinks with ca. 1Hz. At this time the update may be interrupted. As soon as the LED flashing increases to 8Hz, the data are internally flashed (takes approx 10s). This procedure may and also the power supply should not be interrupted. After the update each LED shortly switch on and the PC-AG adapter is rebooted. M. Stich 2-6 HB158E - PC-AG - RE_950-0KB31 - Rev. 08/25