FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Similar documents
IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.


This package contains: 1 UC-232A USB-to-Serial Converter 1 Installation Disk 1 User Manual If anything is damaged or missing, contact your dealer.

HDMI Optical Extender USER MANUAL VE882 / VE892

USB-to-Serial Console Adapter

If anything is damaged or missing, contact your dealer.

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

If anything is damaged or missing, contact your dealer.

If anything is damaged or missing, contact your dealer.

Thunderbolt 3 Multiport Dock USER MANUAL UH7230

RS RS-485 INTERFACE CONVERTER IC-485S & IC-485SI. User s Manual

4 Port KVM Switch. If anything is damaged or missing, contact your dealer.

USB 2.0 DVI KVM Switch USER MANUAL CS682

DVI Video Switch USER MANUAL VS-261 / VS-461

CS-231. User Manual. Copyright ATEN International Co., Ltd. Manual Part No. PAPE G Printing Date: 11/2006

USB-C Multiport Dock with Power Charging USER MANUAL UH3230

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

4-In-1-Out / 1-In-4-Out (Reversible) Bitronics Auto Switch. AS-8144B/AS-8441B User's Manual

CS-64U. User Manual

USB to RS232 Adapter

If anything is damaged or missing, contact your dealer.

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

Quick Start Guide Bluetooth to Serial Adapter

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

PCI Express Serial Card

1 Port Industrial USB to RS232 Serial Adapter with 5KV Isolation and 15KV ESD

VS0801H 8-Port HDMI Switch RS-232 Control Tool V User Manual

Serial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement.

PCI Hardware Installation

Introduction. Table of Content. Overview. Automatic Mouse Conversion. Introduction

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

User Manual CL

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

HomeVision-Serial. Add-On Card. Installation and Operation Manual

2/4/8 Port USB to Serial Adapter Hub with COM Retention

Active RFID Reader User Manual

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

VS0102 / VS0104 / VS0108

USB KVM Switch USER MANUAL CS62US / CS64US

2/4-Port VGA Switch with Audio VS0201 / VS0401 User Manual

Power over Ethernet POEINJ100 POESPLT100. Instruction Manual. 10/100 POE Power over Ethernet Injector - 48V

RocketPort Plus Hardware Installation

8-Port USB-to-Serial RS232 Adapter Hub with Daisy Chain - Rack Mountable

CardBus 10/100 Fast Ethernet PC Card UE1205CB. Instruction Guide. The Professionals Source For Hard-to-Find Computer Parts. Revised: July 24, 2002

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

4 Port PCI Express PCIe Serial Combo Card - 2 x RS232 2 x RS422 / RS485

5 Port Energy-Efficient Gigabit Ethernet Desktop Switch

VM0404H 4x4 HDMI Matrix Switch RS-232 Control Tool User Manual V

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

Professional USB to Serial Adapter Hub with COM Retention

16950 RS-232 Dual Voltage / Dual Profile Serial Card

5 or 8 Port 10/100 Ethernet Desktop Switch

1 Port FTDI USB to RS232 Null Modem Adapter

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

An ISO-9001 Certified Company

Professional USB to Serial Adapter Hub with COM Retention

Bluetooth RS-232 Adapter

Single Port Serial PC Card User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Enclosure TS-530 User Manual

Manual Industry Interfaces

ipaq Networking 5 Port 10/100 Fast Ethernet Auto Sensing Switch

Installation Guide 2/4 port DVI Secure KVM

Bluetooth Serial Adapter

ZM24x Quick-Connect Industrial Modem. User s Manual

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

DeviceMaster RTS 16-Port Hardware Installation

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

UC-2000 / UC-2000L. User Manual

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

8 Port Unmanaged Gigabit Ethernet PoE+ PSE Switch - 30W per Port

USB to RS232 Adapter 2 Port USB Hub

PCI Express 4-Port Industrial Serial I/O Cards

Instruction Guide. PCI 1-2 Port Serial Card PCI1S550 PCI2S550 PCI2S550_LP. The Professionals Source For Hard-to-Find Computer Parts

SeaLINK+8/USB. Sealevel Systems, Inc P.O. Box 830 Liberty, SC USA. Phone: (864) FAX: (864)

ATX12V 2.2 Power Supply for HP & Compaq Systems

1 Port PCI Express Parallel Adapter Card - EPP/ECP 2 Port PCI Express Parallel Adapter Card - EPP/ECP

ADAM Fiber Optic to RS-232/422/485 Converter

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port)

Installation Guide Solar Power Bluetooth Hands-free Car Kit GBHFK231

1080p HDMI KVM Console Extender Over Fiber with HDMI Audio & IR - 1km

3.5 External IDE Drive Case

2-Port Serial-to-IP Ethernet Device Server - RS232

Bluetooth to Serial Adapter GBS301 PART NO. M1229

SeaPORT+2TM. Sealevel Systems, Inc. Part # Phone: (864) FAX: (864) P.O. Box 830 Liberty, SC USA

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

ExpressCard Serial Adapter

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

ExpressCard Serial Card

Table of Content Introduction. Overview. Introduction

4 Port RS232 Mini PCI Express Serial Card 2S 1P Mini PCI Express Serial/Parallel Combo Card

Bluetooth RS-232 Dongle. User s Manual BTS-100

Transcription:

FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that which the receiver is connected; Consult the dealer or an experienced radio/television technician for help. RoHS This product is RoHS compliant. SJ/T 11364-2006 The following contains information that relates to China.

ic485ai User Manual Online Registration International North America http://support.aten.com http://www.aten-usa.com/product_registration Telephone Support International 886-2-8692-6959 China 86-10-5255-0110 Japan 81-3-5323-7178 Korea 82-2-467-6789 North America ATEN TECH 1-888-999-ATEN ATEN NJ 1-732-356-1703 United Kingdom 44-8448-158923 Technical Support For international online technical support including troubleshooting, documentation, and software updates: http://support.aten.com For North American technical support: Email ATEN TECH support@aten-usa.com ATEN NJ sales@aten.com Online Technical Support ATEN TECH http://www.aten-usa.com/support ATEN NJ http://support.aten.com Troubleshooting ATEN TECH http://www.aten-usa.com Documentation Software Updates ATEN NJ http://www.aten.com Telephone ATEN TECH 1-888-999-ATEN ATEN NJ 1-732-356-1703 - 3 -

Package Contents The RS232 / RS485 Interface Converter package contains the following items: 1 IC485AI Bidirectional Isolated Converter 1 Power Adapter 1 User Manual Check to make sure that all the components are present and that nothing got damaged in shipping. If you encounter a problem, contact your dealer. Read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit, and/or any of the devices connected to it. * Features may have been added to the ic485ai since this manual was printed. Please visit our website to download the most up-to-date version of the manual. Copyright 2001 ATEN International Co., Ltd. Manual Part No. PAPE-0194-100 Manual Date: 2010-03-26 ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners. - 4 -

Overview Although RS-232 serial ports are found on almost every computer, because of their slow transmission speeds, limited range, and limited networking capabilities, they are not an effective solution for industrial strength long distance communications systems. Systems based on the RS-422 and RS-485 standards, on the other hand, are not subject to the RS-232 limitations because they utilize different voltage lines for the data and control signals. The IC-485AI Isolated Converter is a bidirectional converter that transparently converts RS-232 signals to RS-422 / RS-485 signals (and vice versa), thus permitting the creation of reliable long distance data communications systems using standard computer hardware. The IC-485AI provides Point-to-Point; Multidrop; and Simplex operations over distances of up to 1200 m (4000 ft.). Designed with built in optocouplers for exceptional signal isolation, plus transformers for excellent power isolation, this extremely reliable isolated converter enhances the quality of data communications at the same time that it protects your equipment from electrical surges of up to 2000 volts. Features Automatic internal RS-485 bus supervision No external flow control signals for RS-485 required Transient suppression on RS-485 data lines LEDs for easy status monitoring Minimum 2000V isolation protection Up to 115.2 Kbps data throughput DCE / DTE selectable Point-to-Point; Multidrop; and Simplex operating modes Four wire full duplex; two wire half duplex - 5 -

Cable distance of up to 1200 m (4000 ft.) Compact size Components Top view: 1 6 2 4 5 3 1. Status LEDs RTS: Lights to indicate that RTS has been pulled high. TxD: Flashes when data transmission occurs. 2. RS-422 / RS-485 Terminal Block 3. Grounding Tab 4. DCE /DTE Selection Switch If the IC-485AI is going to be plugged into a DTE device, the switch must be set to DCE, and vice versa. 5. Power Jack The cable from the Power Adapter plugs in here. 6. RS-232 DB-25 Female Connector - 6 -

Bottom View: 1 1. DIP Switch This eight segment DIP Switch, located on the unit s bottom panel, is used to configure the switch s operating parameters. - 7 -

DIP Switch Configuration The IC-485AI s settings for Baud Rate, Data Format, and RS-422 / RS-485 Mode are configured by setting the eight segment DIP Switch located on its bottom panel Note: When you change any of the DIP Switch settings, you must reset the device by powering it off, then powering it on again. SW 1-3: Baud Rate Baud Rate SW1 SW2 SW3 1200 ON ON ON 2400 OFF ON ON 4800 ON OFF ON 9600 OFF OFF ON 19200 ON ON OFF 38400 OFF ON OFF 57600 ON OFF OFF 115200 OFF OFF OFF Note: 1. The Baud Rate must be the same for all units on the installation. 2. The default is 9600 bps. SW 4: Reserved - 8 -

SW 5-6: Data Format These two switch segments configure the bit settings for Start, Data, Parity, and Stop. Data Format (bits) SW5 SW6 9 ON ON 10 OFF ON 11 ON OFF 12 OFF OFF Note: The default is 10 bits (1 Start; 8 Data; 0 Parity; 1 Stop). Unless you have a special reason to change this, we recommend that you leave it as is. If you do change it, however, all the units on the installation must be changed to match. SW 7-8: RS-422 / RS-485 Operating Mode SW7 determines whether the unit operates as an RS-422 or RS-485 converter. As an RS-422 converter, SW8 determines whether the unit is configured for Master or Slave operation. As an RS-485 converter, SW8 determines whether the unit operates in RTS Control Mode or Auto Send Data Mode. Operating modes are discussed in detail in the next section and on p.15 Note: RS-422 is used for 4 wire hookups; RS-485 is used for 2 wire hookups. Operating Mode SW7 SW8 RS-422 Master ON ON RS-422 Slave OFF ON RS-485 Auto Send Data Mode ON OFF RS-485 RTS Control Mode OFF OFF - 9 -

Operating Modes The IC-485AI supports three operating modes: Point-to-Point; Multidrop; and Simplex. Point-to-Point and Multidrop can be configured for Full or Half Duplex. Each of the operating modes is explained below. Point-to-Point A Point-to-Point configuration is one in which two devices, located at two different places are linked for communication by a pair of IC-485AI units. There are two configurations: Point-to- Point Full Duplex, and Point-to-Point Half Duplex. 1. Point-to-Point 4 Wire Full Duplex Point-to-Point Full Duplex uses reverse four wire cabling, as shown in the diagram below. DB-25 DB-25 Connect to PC#1 s COM port T- R- R- T- Connect to PC#2 s COM port For both IC-485AI units, set the unit to DCE or DTE depending on what type of device the IC-485AI will plug into (if it will plug into a DCE device, configure it for DTE, and vice versa) Set SW7 and SW8 ON for both units. They are now configured for RS-422 Master operation. - 10 -

2. Point-to-Point 2 Wire Half Duplex Point-to-Point Half Duplex uses straight through two wire cabling, as shown in the diagram below. DB-25 DB-25 Connect to PC#1 s COM port T- R- R- T- Connect to PC#2 s COM port For both IC-485AI units, set the unit to DCE or DTE depending on what type of device the IC-485AI will plug into (if it will plug into a DCE device, configure it for DTE, and vice versa). Set SW7 OFF and SW8 ON for both units. They are now configured for RS-485 Auto Send Data Mode (see p. 15 for RS-485 operation details). Multidrop A Multidrop configuration is one in which more than two devices are linked for communication using several IC-485AI units. One of the devices that one of the IC-485AIs connects to is designated as the Master device. All the remaining devices that the rest of the IC-485AIs connect to are designated as Slave devices. Up to 31 Slave devices can be connected. There are two configurations: Multidrop Full Duplex and Multidrop Half Duplex. - 11 -

1. Multidrop Full Duplex Multidrop Full Duplex uses reverse four wire cabling, to link all the connected IC-485AI units: PC1 COM1/ COM2 Master Slave 1 Slave 2. Slave 31 PC2 COM1/ COM2 PC3 COM1/ COM2 For all IC-485AI units, set the unit to DCE or DTE depending on what type of device the IC-485AI will plug into (if it will plug into a DCE device, configure it for DTE, and vice versa). For the Master unit, set SW7 ON; set SW8 ON (RS-422 Master mode). For all of the Slave units, set SW7 ON; set SW8 OFF (RS- 422 Slave mode). Note: 1. No more than 31 Slave units can be connected. 2. When any of the Slave units transmits data, none of the other Slaves may transmit. RTS for all other Slave units must be pulled low. - 12 -

2. Multidrop Half Duplex Multidrop Half Duplex uses reverse two wire cabling, to link all the connected IC-485AI units: PC1 COM1/ COM2 Master Slave 1 Slave 2 Slave 3. Slave 31 PC2 COM1/ COM2 PC3 COM1/ COM2 PC4 COM1/ COM2 For all IC-485AI units, set the unit to DCE or DTE depending on what type of device the IC-485AI will plug into (if it will plug into a DCE device, configure it for DTE, and vice versa). For all of the units set SW7 and SW8 according to the table on p.9 to configure each unit s RS-485 operating mode (see p.10 for RS-485 operation details). Note: No more than 31 Slave units can be connected. - 13 -

Simplex A Simplex configuration is one in which more than two devices are linked for communication using several IC-485AI units in a manner similar to Multidrop. The difference is that in a Simplex configuration, the Master device can only talk, and the Slave devices can only listen. Simplex uses reverse two wire cabling to link all the connected IC-485AI units, as shown in the figure below: PC1 COM1/ COM2 Master Slave 1 PC2 COM1/ COM2 Slave 2 PC3 COM1/ COM2 Slave 3 : : Slave 31 PC4 COM1/ COM2 For all IC-485AI units, set the unit to DCE or DTE depending on what type of device the IC-485AI will plug into (if it will plug into a DCE device, configure it for DTE, and vice versa). For all of the units (Master and Slave), set SW7 ON; set SW8 ON. Note: No more than 31 Slave units can be connected. - 14 -

Installation 1. Make sure that all the devices you will be connecting up are powered off. 2. Set each IC-485AI s configuration switches according to the information provided in the Switch Configuration and Operating Modes sections. 3. Plug the IC-485AI s DB-25 female connector into the computer s RS-232C port. 4. Connect the IC-485AI units to each other. a) Use two or four wire twisted pair cable in a reverse or straight through configuration according to the information provided in the Switch Configuration and Operating Modes sections. Note: 1. When tightening the terminal connector screws it is recommended to use a Phillips PH1 Screwdriver. 2. Over-tightening the terminal connector screws may result in damage to your IC-485AI and difficulty loosening the screws. b) See p.17 for the Terminal Block pin assignments. 5. Power on the computers. The units are now ready for operation. Note: When connecting units over long distances, it may be necessary to install 120Ω resistors. See the diagrams on the next page for details. - 15 -

RS-422 / RS-485 Installation Diagrams Master Slave 31 Slave 1 Slave 30 4,000 RS-422 Full Duplex Note: When the distance between both ends of the installation is large and/or the transmitted signals are unstable, insert 120Ω terminal resistors between pins 1 and 2 and between pins 3 and 4 on the terminal blocks of the two units at each end of the installation. Master Slave 31 Slave 1 Slave 30 4,000 RS-485 Half Duplex Note: When the distance between both ends of the installation is large and/or the transmitted signals aren t stable, insert a 120Ω terminal resistor between pins 1 and 2 on the terminal blocks of the two units at each end of the installation. - 16 -

Appendix Terminal Block Pin Assignments Pin DCE/DTE 1 Transmit +V 2 Transmit -V 3 Receive -V 4 Receive +V Circuit Test To test the IC-485AI s internal circuits, connect a dumb terminal to the unit and do the following: 1. Set the DCE / DTE switch to the opposite of the terminal. 2. Set all DIP Switch segments to ON. 3. Connect one wire from Tx+ (1) to Rx+ (4); connect a second wire from Tx- (2) to Rx- (3). 4. Set the terminal to Full Duplex. 5. Set the baud rate of the communicaton application to 1200 bps. 6. Enter data. If the circuit is operational, data appears on the screen - 17 -

RS-485 Operation Mode Flow Charts RTS Control Mode Start RTS=0 Send Yes No Receive Yes No RTS=1 Receive Data Send Data Complete Yes No Yes Complete No The IC-485AI operates in RS-485 RTS Control Mode when both SW7 and SW8 are set to OFF. In this mode, RTS is pulled high when the computer makes a request to send data. - 18 -

Auto Send Data Mode Start Receiving Data Yes Busy CTS=1 No Idle CTS=0 Receive Data No Data to Send Yes Complete Yes No Send Data Yes Complete No The IC-485AI operaties in RS-485 Auto Send Data Mode when SW7 is set to OFF, and SW8 is set to ON. In this mode, the status of the bus line is auto-detected in order to prevent more than one signal on the line. If the the bus line is busy, CTS is pulled high, and the IC- 485AI will not send data to the bus line. If the bus line is determined to be idle, CTS is pulled low and the IC-485AI sends data to the bus line. - 19 -

DCE / DTE Connection Description Device s Connector Pin # Cable IC-485AI DCE DTE DCE DTE DB-9 DB-9 DB-25 DB-25 25/25 or 9/25 pin DCE DTE DB-25DB-25 1 1 (PG) 1 1 2 3 3 2 Tx Rx 2 3 3 2 2 3 Rx Tx 3 2 8 7 5 4 RTS CTS 4 5 7 8 4 5 CTS RTS 5 4 6 6 6 6 (DSR) 6 6 5 5 7 7 SG 7 7 1 1 8 8 (CD) 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 (SCD) 12 12 13 13 (SCS) 13 13 14 14 (STD) 14 14 15 15 (TC) 15 15 16 16 (SRD) 16 16 17 17 (RC) 17 17 18 18 18 18 19 19 (SRS) 19 19 4 4 20 20 (DTR) 20 20 21 21 (SQD) 21 21 9 9 22 22 (RI) 22 22 23 23 (DRS) 23 23 24 24 (XTC) 24 24 25 25 25 25-20 -

Specifications Function Power Consumption Data Rate Connectors Specification DC 9V; 900mW (max.) Up to 115.2 Kbps under 1200 m (4000 ft.) 1 x DB-25 female (RS-232); 1 x 4 Post Terminal Block (RS-422 / RS-485); 1 x Grounding Tab Function Slide Switch DCE / DTE Select Switches DIP Switch Segment 1-3: Baud Rate; Segment 4: Reserved; Segment 5&6: Data Format (bits); Segment 7&8: RS-422 / RS-485 Select Cable Distance Up to 1200 m (4000 ft.) Operating Temperature 0 ~ 50ºC Storage Temperature 20 ~ 60º C Humidity 0 ~ 80% RH Housing Plastic (ABS) Weight 60 g Dimensions (L x W x H) 54 x 74.5 x 18.5 mm - 21 -

Troubleshooting Symptom Data Transmission Failure Data Loss or Error Action Check that IC-485AI units are securely plugged into the computers serial ports. Check that the cables are properly set up and properly connected. Check that SW1 and the DIP Switch are set properly. Insert terminal resistors according to the information given on p. 13 Check that the Data Rate and Data Format are the same for all devices. Insert terminal resistors according to the information given on p. 13 Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM THE DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT, DISK OR ITS DOCUMENTATION. The direct vendor makes no warranty or representation, expressed, implied, or statutory with respect to the contents or use of this documentation, and specially disclaims its quality, performance, merchantability, or fitness for any particular purpose. The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions, or update. For further inquires please contact your direct vendor. - 22 -