DCT7088 Portable Digital Correlation Transit Time Flowmeter

Similar documents
Portable Dual Frequency Doppler Flowmeter

DMTFP Portable Ultrasonic Flow Meters

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

Series TFXP PORTABLE TRANSIT TIME FLOW METER FEATURES

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Ultra Sonic Flowmeter DATASHEET

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

Clamp-On Transit Time Ultrasonic Flow Meters

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

Series DMHF Heat Meter

Ultrasonic Heat Flow Meters

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Ultrasonic Flow Meter Brochure

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

THE TECHNOLOGY BEHIND THE MEASUREMENT

SITRANS F flowmeters SITRANS F US

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Aysix 200 Hand-Held Flow Meter

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co.

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

Electro-Magnetic Flowmeters Converters

Model Sono-Trak General Specification

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

DCT-7088 Portable Digital Correlation Transit Time Ultrasonic Flowmeter

Flow Measurement SITRANS F US Clamp-on

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

Advanced Test Equipment Rentals ATEC (2832) PANAMETRICS. 25DL Multi-Mode Ultrasonic Thickness Gage with Internal Datalogger

REGAL Series RH40. Handheld Ultrasonic Flow & BTU Meter. Applications. Features and Benefits

Advanced Test Equipment Rentals ATEC (2832)

OPERATING INSTRUCTIONS

Smart flow meter. Smart phone. Smart idea.

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000

Series TFXD FIXED LOCATION TRANSIT TIME FLOW METER FEATURES

Level and Flow Measurement. Flow Pulse

Model FP-100 General Specification

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

TransPort. PT900 Portable Ultrasonic Flow Meter for Liquids. GE Oil & Gas

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

UTM10 Series Ultrasonic Transit-time Flowmeters

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

CERTIFICATE of EU TYPE-APPROVAL

Quattro Flow. Air Velocity Analyzers. Mobile Multipoint Evaluation CAMBRIDGE ACCUSENSE, INC.

Flow Measurement SITRANS F US Clamp-on

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

Intelligent sonic online flow measurement. Pouriya Niknam Piramoon System Qeshm, Iran

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

Specialists in Ultrasonic Flow Measurement

SGT-600 SAFETY GROUND TESTER

EC Type-Approval Certificate

Level and Flow Measurement. Flow Pulse

Automated High Pressure Calibrator Model CPC 8000

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

DIN-Rail Mounted Ultrasonic Flow Meter

imag 4700 Series FLANGED MAGMETER

Series ULT Ultrasonic Level Transmitter

Signet Conductivity Electrodes

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

AUTOMATED WATER SAMPLING Portable Samplers and Accessories

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Conductivity Transmitters

OPTISONIC 6400 Technical Datasheet

Explosion-Proof Gauge Pressure Transmitter

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

Remote Asset- Integrity Monitoring

200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics

Track fluid flow from outside the pipe

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

AG3000 SERIES FLANGED MAGMETER

EU Type Examination Certificate

1. Guidelines and Checklists

TRX II. Portable documenting calibrator

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

imag 4700 Series FLANGED MAGMETER

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

CI-150 Series. Airborne Particle Counters

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

AiRanger DPL Plus. Dual-Point Ultrasonic Level Measurement System

CALIBRATORS. BetaGauge II INTRINSICALLY SAFE MODEL AVAILABLE

Data sheet deltwavec-f

Handheld ultrasonic flowmeters

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

Wall Thickness Monitor

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

DMC-1400 Documenting Multi-function Calibrator

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

Transcription:

DCT7088 Portable Digital Correlation Transit Time Flowmeter

DCT7088 Portable Digital Correlation Transit Time Flowmeter Applications HVAC Potable water Ultrapure liquids De-ionized water Petroleum products Water & waste management Features Accuracy to +/-0.5% 0.001 ft/s flow sensitivity NEMA-6 environmental sealing Easy to install, clamp-on design Bi-directional flow measurement Powerful 65,000 point data logger TimeGate diagnostics & wave form analysis The DCT7088 is the world s most advanced portable transit time flowmeter. Combining digital signal processing (DSP) with correlation detection methods, it features exceptional performance and flexibility. While principally designed for clean liquid applications, the instrument is tolerant of liquids with higher concentrations of entrained solids or gas bubbles than was previously possible with transit time technology. The non-intrusive, clamp-on transducers can be installed without flow interruption and insure leak-free measurements with zero pressure drop. The simple menudriven operation of the DCT7088 allows the meter to be configured in a fraction of the time necessary for competitive portable transit time flowmeters. Housed in a rugged NEMA-6 (IP67) enclosure, the DCT7088 is waterproof against accidental immersion and splashproof with the lid open. The display is a high resolution, backlit LCD providing excellent visibility, even in poorly lit conditions. Outputs include a 12 bit, 4-20mA analog signal and RS232 serial interface. The flowmeter also incorporates a powerful data logger that can record up to 65,000 data points for subsequent uploading to a personal computer. A separate memory function stores up to 16 sets of site parameters, eliminating the requirement to re-enter setup data when returning to a location for further measurements. The DCT7088 can be programmed to start and finish flow measurements at predetermined times for unattended operation. In addition to password protection, a padlock can be attached to the instrument enclosure to avoid any chance of unauthorized tampering. The meter will provide up to 16 hours of continuous battery operation and can be fully recharged in only 8 hours. Unlike competitive transit time flowmeters, multiple transducers are not necessary for different pipe materials and sizes. The standard transducer set is suitable for most plastic, metal and even concrete-lined pipes, and for diameters from 1 in. (25mm) to 200 in. (5m). The DCT7088 is supplied with an impressive array of optional accessories. The UTG is a compact and rugged, ultrasonic thickness gauge which allows pipe wall thickness to be quickly determined from the outside of the pipe. As an instrument separate from the DCT7088, the UTG can be used for other functions such as measuring the corrosion or erosion of storage tank walls, etc. To provide an immediate paper record of individual flow measurements, logged data and/or site parameters, a small thermal printer is also available. Advanced signal processing, simple operation and rugged construction combine to provide a flowmeter that can confidently be used in many applications throughout the plant.

TimeGate Program Supplied with each DCT7088 is the acclaimed TimeGate configuration and signal analysis program. While not necessary to set up or operate the instrument, it offers a simple, Microsoft Windows based method to configure the flowmeter and access the extensive waveform diagnostics available from the DCT7088. Featuring easy-to-use pull down menus and pop up windows, it provides a very rapid and versatile means to select the ideal transducer location in marginal applications. Stored site and configuration data can also be downloaded to one or more instruments, thus eliminating the need to individually program multiple meters. In addition, it provides a paperless method of retaining and archiving the calibration data simplifying the data retention and reporting requirements necessary for ISO9000, OSHA and FDA compliance. Performance Specifications Flow Range: ±0 to 50 ft/s (±0 to 15 m/s) Accuracy: Velocity >1 ft/s (>0.3 m/s) ± 0.5% of velocity Velocity 1 ft/s ( 0.3 m/s) ± 0.03 ft/s (0.01 m/s) Sensitivity: 0.001 ft/s (0.3 mm/s) at any flow rate including zero Linearity: 0.003 ft/s (0.9 mm/s) Pipe Size: 1 in. to 200 in. (25mm to 5m) Physical Specifications Transmitter: Transducers: Weight: NEMA-6 (IP67), waterproof against accidental immersion and splashproof with lid open. Encapsulated design. Standard cable length: 16 ft. (5m) Approximately 11 lbs. (4.9 kg) 8 hr. battery Approximately 15 lbs. (6.8 kg) 16 hr. battery opt. DCT7088 Specifications While the flowmeter can be fully set up via its integral keypad, the TimeGate program provides a simple and rapid means by which multiple flowmeters can be configured. In addition, the waveform analysis allows the user to easily determine the optimum location for transducer installation. Microsoft, Windows and Windows 95 are registered trademarks of Microsoft Corporation. Functional Specifications Outputs: Power Supply: Keypad: Display: Data Logger: Temperature: 4-20 ma (into 1,000 Ohms), 12 bit, isolated. RS232 serial interface Built-in lead acid gel battery. 8 hours continuous operation std. 16 hours continuous operation opt. With AC adapter/battery charger 90-264 VAC, 50-60 Hz. std. 19 key with tactile action 40 character, 2 line alphanumeric, backlit LCD. Screens include: present and total flow, velocity, signal strength and delta T. Greater than 65,000 data points, time stamped. Programmable in one second intervals. -40 to +300 F (-40 to +150 C): transducers -5 to +140 F (-20 to + 60 C): transmitter For higher temperature, please consult factory.

Ordering Information Model Product Description DCT7088 Portable Digital Correlation Transit Time Flowmeter Polysonics is approved to the ISO 9001 quality standard. Code 16A or XXXXA Battery Duration 1 8 hours 2 16 hours Code Code Transducer Cable Length 16 ft. (5m) cable - standard Additional cable, max. 1000 ft. (305m), 10 ft. increments Additional Options 0704/0188 0704/0187 22334-0001 20739-0001 Typical Model Number: UTG ultrasonic thickness gauge, English units UTG ultrasonic thickness gauge, Metric units Thermal printer kit High temperature transducer block -40 to +470 F (-40 to +243 C) DCT7088-1-16A An important benefit of the DCT7088 is its ability to operate in the most severe weather conditions. Featuring a NEMA 6 enclosure, the instrument can even be used during heavy rain without fear of damage. In addition to the DCT7088, other Polysonics transit time flowmeters include single and multi-channel models for permanent installation. A comprehensive range of award winning digital Doppler ultrasonic flowmeters is also available for aerated or solids bearing fluids. With up to 16 hours of battery operation, a 65,000 point data logger and lockable case, the meter can be used for remote and unmanned flow monitoring. Microsoft Windows Represented by: Polysonics, Inc. 10335 Landsbury Drive Suite 300 Houston, TX 77099, USA Tel: (281) 879-3700 Fax: (281) 498-7721 ISO 9001 Polysonics reserves the right to alter specifications without notice. Issue :7088 / Oct. 1997

MODEL DCT7088 PORTABLE DIGITAL CORRELATION TRANSIT TIME FLOWMETER RECOMMENDED PROCUREMENT SPECIFICATION 1. The flowmeter shall utilize ultrasonic, digital transit time correlation technology to provide indication, totalization and signal transmission of liquid flow rate in full pipes. 2. The instrument enclosure will be environmentally protected to NEMA 6 (IP67). 3. The instrument will incorporate a rechargeable battery suitable for 8 hours continuous operation. An optional internal battery providing over 16 hours continuous operation will also be available. The battery must be fully chargeable within a maximum 8 hour period. 4. Configuration will be via a front panel, 19-key, flat membrane keypad with tactile feedback. Input parameters will be password protected. The nonvolatile memory shall retain totalizer and user parameters for up to five years. Diagnostics shall be accessible via the keypad. 5. The TimeGate signal analysis and configuration program will be supplied with each shipment of flowmeters. This will provide graphical wave form analysis and incorporate pop up windows and pull down menus to facilitate rapid configuration of multiple instruments. 6. The flowmeter shall have a built-in microprocessor to provide for adapting instrument hardware to existing piping and flow conditions. It will automatically calculate transducer spacing and read in English or metric units. Low flow cut-off, bi-directional totalization with selectable resolution, automatic speed of sound calculation of measured fluid and adjustable damping, shall be standard and configurable via the keypad. 7. The flowmeter will measure flow rates of clean liquids with a velocity span of ±0 to 50 ft/s. A dual transducer will be supplied which shall be suitable for for pipe sizes from 2 to 200 inches. 8. Accuracy of the instrument will be ±0.5% of velocity or ±0.05 ft/s, typical on a calibrated system. 8.1 Flow sensitivity will be ±0.001 ft/s at any flow rate including zero. 8.2 The linearity of the instrument will be 0.1% of scale.

Model DCT7088 (Continued) Procurement Specification Page 2 of 2 9. The analog output shall be an isolated 4-20mA DC proportional to flow. The maximum resistive load shall be 1,000 ohms. Output current limiting circuitry will be incorporated in the flowmeter electronics. An RS232 serial interface will also be provided. 10. The flowmeter electronics shall be designed to operate at temperatures between -5 F and +140 F (-20 C to +60 C). All electronic circuits are to be interchangeable with other flowmeters having the same model number. All circuit boards will be conformally coated with an anti-fungus compound. 11. The display will be a high resolution, backlit, 40 character LCD. 12. A test block will be supplied, as standard, for field performance verification. 13. The transducers will attach to the outside of the pipe by means of a slide-track mounting method. The transducer cable length will be 16 feet (5m). Longer transducer cable lengths will optionally be available. 14. The transducers will be suitable for operation from -40 F to +300 F (-40 C to +150 C). 15. The manufacturer shall optionally provide an NIST traceable, multi-point flow calibration for the instrument. 16. A 40,000 point data logger, programmable in 1 second intervals, will be included as standard in the flowmeter. 17. The enclosure of the flowmeter will provide a facility for the attachment of a padlock to prevent unauthorized access to the display and front panel during unmanned flow monitoring. 18. The instrument shall be manufactured in the USA at an ISO 9001 certified facility. 19. The transit time flowmeter will be the Polysonics Model DCT7088 manufactured by Polysonics Inc., 10335 Landsbury, Suite 300, Houston, Texas 77099-3407, (281) 879-3700 Tel., (281) 498-7721 Fax. Polysonics Inc. 10335 Landsbury, Suite 300, Houston, Texas 77099-3407, Tel. (281) 879-3700, Fax (281) 498-7721 REV. 5/97-1