Handheld ultrasonic flowmeters Reference: AB-FLOW-PO-FL01 Handheld portable ultrasonic flow meter provides abundant capabilities for accurate liquid flow measurement. The utilization of proprietary ultrasound transmission / receiving, transit-time measurement and ultrasonic signal processing technologies allows our flow meter to measure liquid flow rate from outside of a pipe reliably and accurately. The handheld portable clamp-on flow meter is carefully designed so that its user-s are self-explanatory and the instrument is very easy to operate. The unique clamp-on fixture design makes the installation very simple and no special skills or tools required. Due to the non-intrusive nature of the clamp-on technique, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, not pressure dependent, and etc. The handheld portable flow meter is ideal for general flow survey, HVAC hydronic balancing / testing, energy consumption supervision, water conservation management, beverage and food processing, chemical process monitoring, power plant monitoring, and other closed-pipe applications where non-intrusive measurement is required. Benefited from our advanced digital signal processing technology, the handheld ultrasonic flow meter works reliably in both clean and opaque liquid flow. Linearity better than 0.5% Accuracy ±1% Response Time Pipe Size 0-999 seconds, user-configurable ±0.03 ±52 ft/s (±0.01 ±16 m/s), bi-directional 3/4 240 (DN20mm DN6,000mm)
Pipe Material Totalizer Liquid Types Units Liquid Temp Display Security Output port and All metals, most plastics, lined pipe Three 7-digit totals for net, positive and negative flow respectively Virtually all clean liquids and liquids with minor solids(<10,000ppm). Full pipe English (U.S.) or other international metric units 32 F 212 F (0 C 100 C) or 32 F 312 F (0 C 150 C),depending on different transducer type. LCD with backlight,4 16 letters Setup values Modification Lockout. Access code needs unlocking 9-hole RS232C port with simple flowmeter protocol for PC connecting; One isolated OCT for frequency output and pulse output. Transducer Cable Standard 2 15 (2x5m).Longer is available upon request. Transducers Power Supply Data Logger Different type transducers optional. 3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation. 100V-240VAC for the charger Built-in data logger can store over 2000 lines of data Housing Material Aluminum alloy protective case. Suitable for normal and harsh environment Case Size Weight Language 7.9 x3.6 x1.3 (200mmx92mmx32mm) 1.2 lbs (538g) with batteries English, French, Spainish, Italian, etc
Reference: AB-FLOW-PO-FL02 Clamp on transit-time Technology With Built-in Thermo Printer Portable ultrasonic flow meter is carefully designed for flow check and flow survey easily. The flowmeter can measure different flow test points at one time,and the portable flow meter has a long battery time which can work over 20 hours continuously.with a built-in thermo printer,the portable flow meter can print the data at stop. The clamp-on installing transducers make the portable flowmeter operating easily and no need special training and skills. Clamp-on transducers make no need to cut pipe and no risk of leakage,no pressure drop,no moving parts, no risk of corrosion,etc. Accuracy Better than ±1% Response Time 0.5s Pipe Size Pipe Material Main unit temperature Liquid Types Units Liquid Temp Display Output port and ±0.01 to 32m/s, bi-directional DN15mmm~DN6000mm All metals, most plastics, concrete, lined pipe -10 70 Virtually all commonly used liquids (full pipe) English (U.S.) or other international metric units 0 to 100 LCD with backlight, 2 10 characters Isolated RS-485,support MODBUS protocol; Built-in printer
Transducer Cable Transducers temperature Shielded transducer(sensor) cable Standard length 5m. Max extended 500m 0-160 Power Supply Ni-H inside battery. When fully recharged, it will last over 20 hours of operation. Or 220Vac(standard),110Vac is optional Case Size Weight Language 210mmx100mmx180mm 2.5kg The current version has English,Italian and Chinese.Chinese version can be deleted for international trade
Ultrasonic flowmeters/calorimeters Reference: AB-FLOW-FI-CA01 The low cost ultrasonic flowmeter employs cutting-edge technologies on ultrasonic transit-time measurement, digital signal processing and surface mounting electronics. It provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. The proprietary signal quality tracking and self-adapting techniques allow the system to optimally adapt to different pipe materials automatically. This unit has four local keys which can be used for setting all parameters, including inputing value. This type ultrasonic flowmeter can be equipped with an optional keyboard module. The users can either use the RS-485 or the display / keyboard to program the flowmeter. The transducer installation is also simple and no special skills or tools are required. Due to the non-intrusive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency. This type ultrasonic flow meter is designed for large quantity, low cost applications. Its unique features, particularly very low cost, very high performance and very small size, make it the ideal choice for industrial automation, processing control, water source management, flow meter networking and OEM applications. Accuracy Better than ±1% Response Time 0.5s Pipe Size 0.03-105ft/s(0.01-32m/s) 1-240 (DN25mm-DN6000mm)
Pipe Material Main unit temperature Liquid Types Units Display Output port and Transducer Cable all common used pipe materials -10 70 suitable for most pure liquids and liquids with minor particles English (U.S.) or other international metric units LCD backlight 2*20 letters display 4 local keys for all parameters setting and Versatile inputs/outputs,including 3 way 4-20mA input and 2 way OCT output(relay output) and one way 4-20mA output and Isolated RS485 with power surge protection. Support MODBUS.Well suited for reliable networking. Shielded transducer (sensor) cable Standard length 5m. Max extended 500m Power Supply Case Size Language Isolated 8-36V DC power supply 90 90 32mm English, French, Spainish, Italian, etc
Reference: AB-FLOW-FI-CA02 The wall mounted ultrasonic flow meter belongs to range of fixed type ultrasonic flow meters, as a good selling product, it has been carefully designed, so it provides abundant capabilities for accurate liquid flow measurement. The wall-mounted unit can support clamp on transducers, insertion hot-tap transducers and inline type transducers. It can be powered by AC and DC power and solar powered. With clamp-on transducers, it is called as clamp on ultrasonic flow meters and can provide many good features:no need to cut pipe,no direct touch to liquid, no pressure drop, no moving parts, no risk of contamination, no risk of corrosion,and etc. With insertion transducers, it will be insertion ultrasonic flow meters and can be used for pipe size>dn80 mm. Insertion flowmeter can support higher accuracy flow measurement. With out patented hot-tap installing tool, insertion transducers can be installed without any flow stop. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time Pipe Size Pipe Material Cable Liquid Types 0.5s (Collecting 128 groups of data each cycle) ±0.03 ±105 ft/s (±0.01 32 m/s), bi-directional 1 240 (25mm-6000mm) All metals, most plastics, fiber glass, etc. Allow pipe liner Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe)
Units Liquid Temp Display Output port and input port and English (U.S.) or metric 0 C 150 C LCD with backlight. 2 20 letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is 6-1000mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by email 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: 85-264V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.
Reference: AB-FLOW-FI-CA03 Insertion liquid ultrasonic flow meter employs a pair of insertiontype ultrasonic transducers to measure the flow by inserting the transducers into the pipe wall. The transducers do not extrude into the flow, thus, do not generate any disturbance or pressure drop to the flow. Comparing with a clamp-on flowmeter, the biggest advantages of our wetted-type flowmeter are its long-term stability, better signal quality and less installation uncertainty. The last two features can also be translated into higher accuracy. The insertion liquid flow meter is designed for pipe larger than 3 (DN80mm). For smaller pipe, our spoolpiece model, flow cell inlie flow meter, might be a better choice. When pipe size becomes smaller, the cost of a spool-piece inline transducer comes down. The Insertion type ultrasonic flow meter is ideal for flow surveys and closed-pipe applications, such as normal water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Pipe Material ±0.03 ±105 ft/s (±0.01 32 m/s), bi-directional From 80mm All metals, most plastics, fiber glass, etc. Allow pipe liner
Cable Liquid Types Units Liquid Temp Display Output port and input port and Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe) English (U.S.) or metric 0 C 150 C LCD with backlight. 2 20 letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is 6-1000mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by email 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: 85-264V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.
Reference: AB-FLOW-FI-CA04 This type flow meter utilizes a flow cell (or socalled spool-piece) where transducers are already built-in. The big advantage are its high-accuracy and long-term stability. It is calibrated in factory and no extra error will be introduced by installation. Since it is still noninvasive, it does not generate any disturbance or pressure drop to the flow. Abtds-100FB/C/G are all wall-mount type or fixed-installation type, thus are ideal for long-term deployment for flow measurement and closed-pipe applications, such as liquid process control, water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Pipe Material Cable Liquid Types Units Liquid Temp ±0.03 ±105 ft/s (±0.01 32 m/s), bi-directional DN15 DN1000 All metals, most plastics, fiber glass, etc. Allow pipe liner Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe) English (U.S.) or metric 0 C 150 C
Display Output port and input port and LCD with backlight. 2 20 letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is 6-1000mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by email 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: 85-264V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.
Reference: AB-FLOW-FI-CA05 This type flow meter utilizes a flow cell (or socalled spool-piece) where transducers are already built-in. The big advantage are its high-accuracy and long-term stability. It is calibrated in factory and no extra error will be introduced by installation. Since it is still noninvasive, it does not generate any disturbance or pressure drop to the flow. Abtds-100FB/C/G are all wall-mount type or fixed-installation type, thus are ideal for long-term deployment for flow measurement and closed-pipe applications, such as liquid process control, water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Pipe Material Cable Liquid Types Units Liquid Temp ±0.03 ±105 ft/s (±0.01 32 m/s), bi-directional DN15 DN1000 All metals, most plastics, fiber glass, etc. Allow pipe liner Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe) English (U.S.) or metric 0 C 150 C
Display Output port and input port and LCD with backlight. 2 20 letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is 6-1000mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by email 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: 85-264V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.
Reference: AB-FLOW-FI-CA06 This ultrasonic water meter is our innovation products utilizing advanced transit-time ultrasonic flow measurement technology. Thus, there is no moving part in the sensor, which can ensure the measurement is wear-free and stable over a very long time period. With its maximum 95 C operating temperature and nominal pressure of 1.6MPa, the technical specifications meet the standard for residential meters. Unlike mechanical water meters,the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time,its overall system accuracy doesn t also degrade over time. The designation of this compact meter fits in even the smallest installation conditions and can be mounted separately from the electronics console. The meter also support remote read-out (M-bus or pulse output).when equipped with M-Bus module, as more as 500 water meters can be networked through a twowire bus to a central location for integrated resources management. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Liquid Types Units ±0.03 ±105 ft/s (±0.01 32 m/s), bi-directional DN15 DN40 Virtually all commonly used liquids (full pipe) English (U.S.) or metric
Reference: AB-FLOW-FI-CA07 This ultrasonic water meter is our innovation products utilizing advanced transit-time ultrasonic flow measurement technology. Thus, there is no moving part in the sensor, which can ensure the measurement is wear-free and stable over a very long time period. With its maximum 95 C operating temperature and nominal pressure of 1.6MPa, the technical specifications meet the standard for residential meters. Unlike mechanical water meters,the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time,its overall system accuracy doesn t also degrade over time. The designation of this compact meter fits in even the smallest installation conditions and can be mounted separately from the electronics console. The meter also support remote read-out (M-bus or pulse output).when equipped with M-Bus module, as more as 500 water meters can be networked through a twowire bus to a central location for integrated resources management. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size ±0.03 ±105 ft/s (±0.01 32 m/s), bi-directional From DN50 Liquid Types Units Virtually all commonly used liquids (full pipe) English (U.S.) or metric
Ultrasonic flowmeters with battery Reference: AB-FLOW-FI-FL01 Applied with Euro standard of EN1413, Ultrasonic water meter is a super low power consumption water meter with high-accuracy industry electronic parts equipped. It has many advantages such as: high accuracy, good reliability, no moving parts, no pressure drop, Low maintenance, etc. It is a excellent substitution of other water meters. With high quality parts and advanced technology, the ultrasonic flow meter/water meter have reached a very excellent performance. Unlike mechanical water meters, the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time,its overall system accuracy doesn t also degrade over time.. Accuracy ±1% or ±2% of reading value Response Time 0.5s Pipe Size Pipe Material Main unit temperature Liquid Types 0.03-105ft/s(0.01-32m/s) DN15mm-DN1000mm (Inline type transducers) DN80mm-DN800mm (Insertion type transducers) DN15mm-DN800mm (Clamp-on type transducers) Carbon Steel or stainless steel optional -10 70 Water, sewage and other homogeneous fluids
Max pressure Units Output port and 4.0MPa (DN15-DN40mm) 1.6MPa(DN50-DN450mm) 1.0MPa(DN500-DN600mm) 0.6MPa(DN700-DN1000mm) English (U.S.) or other international metric units OCT output; RS485 port support MODBUS, M-BUS;USART(TTL level) output;,gsm meter readings radio transmission; Power Supply Powered by battery capable of sustaining a continuous meter operation for over 5 years just need one lithium battery (3.6V/19AH)
Reference: AB-FLOW-FI-FL02 Applied with Euro standard of EN1413, Ultrasonic water meter is a super low power consumption water meter with high-accuracy industry electronic parts equipped. It has many advantages such as: high accuracy, good reliability, no moving parts, no pressure drop, Low maintenance, etc. It is a excellent substitution of other water meters. With high quality parts and advanced technology, the ultrasonic flow meter/water meter have reached a very excellent performance. Unlike mechanical water meters, the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time, its overall system accuracy doesn t also degrade over time.. Accuracy Class 2 Or Class 3 Response Time 0.5s Pipe Size Main unit temperature 0.03-105ft/s(0.01-32m/s) Standard insertion transducers DN80-DN800mm;for larger pipe, will need special big insertion transducers. If pipe material is cement or concrete, it will need to use cement insertion transducers. -10 70 Max pressure Units less than 2.5MPa English (U.S.) or other international metric units
Display Output port and Transducer Cable Power Supply 96 Segmantal LCD TTL output; RS485 port support MODBUS, M-BUS. Shielded transducer (sensor) cable Standard length 5m. Max extended 500m Over 4 years while under normal working status. s
Reference: AB-FLOW-FI-FL03 Ultrasonic water meter is developed from ultrasonic flow meter and powered by battery and only for water flow measurement. Because ultrasonic water meter carryies on many good features from ultrasonic flow meter, such as no moving parts,no pressure drop,completed communication protocol,etc, and ultrasonic flow converter and sensor are IP68 class,ultrasonic water meter will be an ideal choice for water meter as the cost is reduced. Clamp-on ultrasonic water meter refers to the flow transducer is clamp-on type, which is clamped onto pipe surface. Clamp-on installing way doesn t need to cut pipe,so there is no pressure drop,no risk of leakage,no maintainance,etc. But as it is battery powered, clamp-on ultrasonic water meter can t get the same accurate level as that of main powered ultrasonic flow meter. Thus, battery powered clamp-on ultrasonic water meter is only for such request. Usually, we recommend main powered ultrasonic flow meter or battery powered ultrasonic water meter with insertion type sensor or spool piece inline type sensor.though clamp-on ultrasonic water meter is not perfect yet, it is a very promising water flow meter once its accuracy is improved.we will try to our best to improve it.. Accuracy Class 2 Or Class 3 Response Time 0.5s 0.03-105ft/s(0.01-32m/s) Main unit temperature Units -10 70 English (U.S.) or other international metric units