Power Supply (48Vdc, 2.5A)

Similar documents
to 48V DC Power Supply

Intelligent Channel Bank Shelf

Type 400 Mounting Shelves

Six-Slot T1 Mini-Repeater Apparatus Case

428 Jack Panel Module

829MA 6 and 829MB 6 Data Mountings

829MA 7 and 829MB 7 Data Mountings

MA-4006, MD-4006 and MU-4006 Mounting Assemblies

CiAC A239AXXX Sealed T1 Mini-Repeater

6-Circuit ( ) and 3-Circuit ( ) 56/64xN Data Service Unit (DSU) Data Port (DP)

C-POWER AC AUTOMATIC CONTROL

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

iconverter 2-Module Power Chassis

Quad Circuit ( ) and Dual Circuit ( ) ISDN Channel Unit

NT1B-300 Rack Installation Instructions

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Breaker Panel Technical Practice NPDRP1114

Westell. Breaker Panel Technical Practice NPDRP1114

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installing the Cisco MDS 9020 Fabric Switch

Innovative Circuit Technology Ltd.

W FXS/GT Channel Unit Installation Guide

Broadband Automatic Disconnect Switch. User Manual

CMSA-100 Manual. Cinema Media Server Automation

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for VSP 4850GTS

Rack Mount Power Supplies

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

MPF-1, Mains Power Filter User Manual

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

AEXX-349 SERIES REMOTE DISPLAYS

28-Position 23 Rack Mounting Model RM23-20X

Site Preparation CHAPTER

87421/22A Power Supply. Operating and Service Manual

Basketball Shot Clock Set LX2180 Manual

hp uninterruptible power system r12000 xr models installation instructions

EMC1600 Series Media Converter and Ethernet Extender Chassis

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

W ETO W/SC Installation Guide

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Aruba JL311A Cable Guard Installation Instructions

Automated Tuner System Power Distribution Hub

Junos WebApp Secure 5.0 Hardware Guide

Global Water Instrumentation, Inc.

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

AMP Rack User Manual. Publication Rev G

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

TRC-190 User s Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

TRC-190 User s Manual

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Multi Unit Enclosed Meter

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

INSTALLATION MANUAL SLI 50 INVERTER

MPP200 User s Manual

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Installation and Operation

User s Guide. POWERVAR Single Phase Power Conditioners

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

* * Agilent Power Distribution Unit (PDU) Installation Guide

Back-UPS RS APC Back-UPS RS 800VA 120V Black

High-Speed Voice and Data Link Local Powered Remote Terminal

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

CPS3200U Upstream System Telephone Power for Video 48 Vdc Input, ±190 Vdc Output Converter/Limiter System

SLI 15 INVERTER SERIES, 1500 W

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

DCM Digital Control Modules

E-Series Site Preparation Guide

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution

PS-5030 (5A) OPERATION MANUAL

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Enhanced Mini-Chansim Model VCS-232

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

High Power over Ethernet Midspans PD Port Model PD Port Model

A. Advanced Features. Configurable High Power Solution

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

BIPOLAR OPERATIONAL POWER SUPPLY

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

PS-1030 (30V) OPERATION MANUAL

Active UTP Transceiver Hub with Integral Isolated Camera Power

P/S Accessory Cabinet Installation Manual

Transcription:

Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1. GENERAL............................................................................. 2 Part 2. INSPECTION........................................................................... 2 Part 3. APPLICATION GUIDELINES............................................................. 2 Part 4. MOUNTING............................................................................ 2 Part 5. INSTALLER CONNECTIONS............................................................. 3 Part 6. TESTING.............................................................................. 4 Part 7. TECHNICAL ASSISTANCE.............................................................. 4 Part 8. WARRANTY & CUSTOMER SERVICE.................................................... 4 Part 9. SPECIFICATIONS...................................................................... 6 POWER 8551 80 Figure 1. 8551-80 Power Supply Field repairs/modifications may void compliance with UL Standard 60950 2nd Edition. Compliance with UL Standard 60950 Second Edition is restricted to inside plant wiring. 2006 Charles Industries Ltd. All rights reserved. Printed in United States of America. The availability of features and technical specifications herein subject to change without notice. Page 1 of 7

Section 855-180-201 1. GENERAL 1.1 Document Purpose This document provides general, installation and testing information for the 8551-80 (Issue 1) 48Vdc Power Supply. The 8551-80 is shown in Figure 1. 1.2 Equipment Description The 8551-80 power supply provides filtered, regulated 48Vdc output. The maximum current output of the 8551-80 is 2.5 amps. This unit is UL recognized. 1.3 Equipment Mounting Mounts in a19-inch or 23-inch relay rack and occupies one rack unit (1.75 inches of rack space). 1.4 Equipment Features Features of the 8551-80 power supply includes: Regulated, floating 48Vdc output from standard 120/240Vac, 50/60Hz power source Either polarity can be grounded 6-foot, 3-wire power cord, plugs into any convenient 120Vac, 60Hz grounding-type receptacle Self-protecting against overload a short circuit across the output terminals will not damage the units Direct mounting in a 19-inch relay rack; brackets can also be used for 23-inch relay rack mounting Power LED 2. INSPECTION 2.1 Inspect for Damages Inspect the equipment thoroughly upon delivery. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company. 2.2 Equipment Identification Charles Industries equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment. Each time a major engineering design change is made on the equipment, the issue number is advanced by 1 and imprinted on subsequent units manufactured. Therefore, be sure to include both the model number and its issue number when making inquiries about the equipment. 3. APPLICATION GUIDELINES The power supply can be used in any 48Vdc application that does not exceed its current limitations (2.5A). It is intended to be installed in a protected environment. The current output and noise of the unit is low enough for the unit to be used as a talk battery. Output is floating and either the negative or the positive terminal can be connected to ground as required. 4. MOUNTING When received from the factory, the 8551-80 includes side mounting brackets for flush-mounting in a 19-inch relay rack. Each power supply requires approximately 1.75-inches of vertical rack space (1 slot). Rotating brackets permit flush-mounting in a 23-inch relay rack. Included with the power supply are two mounting kits. The Power Supply to 360-80 mounting kit is used to attach the power supply to the top of the 360-80 shelf in wall or desk mount installations of the 360-80 channel bank. The screws provided in the mounting kit must be used to mount the brackets to the power supply (see Figure 2).

WARNING Mounting Screw Mounting Brackets Power Supply Mounting Screw Mounting Brackets Figure 2. Power Supply to 360 80 ICB Mounting Kit The wall mounting brackets are used to allow the power supply to be mounted to a wall. 4.1 Wall Mounting Vertical installation (walls, specially build structures, etc.) require strict adherence to the mounting instructions to assure trouble free operation and to protect the safety of personnel The shelf should be mounted at a height that will permit convenient access for performing maintenance The shelf will be mounted with one bracket above the other. The front of the shelf can face either to the right or the left. This will provide front panel access on one side of the shelf and rear panel access on the other side If the shelf cannot be mounted to a wall stud a plywood mounting board is required.

Section 855-180-201 Step Action 1. Remove and rotate the bracket 90 degrees so that the flat of the bracket is toward the bottom of the shelf (see Figure 3). 2. Mount the bracket to the shelf. 3. Repeat steps 1 and 2 for the bracket on other side of the shelf. 4. If mounting directly to a wall, locate a stud and mark a spot for the top bracket over the stud. 5. Drill a pilot hole for the fastener at the marked spot (use whatever fasteners are appropriate per local practice). 6. Mount the shelf using one of the fasteners through one of the brackets. 7. Hold a level across the top of the shelf and level the unit. 8. Mark the mounting surface for all the other holes to be used to mount both brackets. 9. Drill pilot holes for the remaining fasteners at the marked spots. 10. Install the remaining fasteners through the mounting brackets. 11. Tighten the fasteners. Power 8551 80 Figure 3. Power Supply with Wall Mounting Bracket 5. INSTALLER CONNECTIONS The power supply has a 6-foot power cord for connecting to a standard 120Vac, 60Hz power source. Terminal block has a protective, insulating cover, fastened with screws. Remove the screws to remove the cover. Connect the positive output lead to the terminal marked with a + and the negative output lead to the terminal marked with a on the terminal block (refer to Figure 4). These terminals are floating and either may be connected to ground as required. For protection against accidental shorts, replace the insulating cover upon completion of the power supply installation. FUSE Figure 4. Location of Terminal Block on the 8551-80 6. TESTING Use the following steps to test the power supply.

Step Action 1. Connect the positive lead of a multimeter to the terminal marked + and the negative lead to terminal marked on the terminal block. The multimeter should read 48V +/ 0.5V. If the test condition is satisfied, no further testing is required. However, if no voltage indication is obtained, proceed with Step 2. If a low voltage indication is obtained, proceed with Step 4. 2. Measure the input voltage of the source. The multimeter should indicate 100 to 260V. If this condition is satisfied, proceed with Step 4. Otherwise, check the AC source feeding the power supply. 3. Check the AC input fuse. Note: A spare fuse is located in the fuse compartment. 4. With the multimeter connected between terminals + and on the terminal block, disconnect the load from the power supply. If removing the load restores the operating voltage to normal, the trouble is caused by an overload or short circuit in the external circuit. If removing the load does not cause the output voltage to return to normal, replace the power supply with a similar unit known to be in good operating condition and retest. 7. TECHNICAL ASSISTANCE If technical assistance is required, contact Charles Industries Technical Services Center at: 847-806-8500 847-806-8556 (FAX) 800-607-8500 techserv@charlesindustries.com (e-mail) 8. WARRANTY & CUSTOMER SERVICE 8.1 Warranty Charles Industries, Ltd. offers a 2-year warranty on this product. Contact your local Sales Representative at the address or telephone numbers below for warranty details. The warranty provisions are subject to change without notice. The terms and conditions applicable to any specific sale of product shall be defined in the resulting sales contract. Charles Industries, Ltd. 5600 Apollo Drive Rolling Meadows, Illinois 60008-4049 U.S.A. 847-806-6300 (Main Office) 847-806-6231 (FAX) 8.2 Field Repairs (In-Warranty Units) Field repairs involving the replacement of components within a unit are not recommended and may void the warranty and compatibility with any applicable regulatory or agency requirements. If a unit needs repair, contact Charles Industries, Ltd. for replacement or repair instructions, or follow the Repair Service Procedure below. 8.3 Advanced Replacement Service (In-Warranty Units) Charles Industries, Ltd. offers an advanced replacement service if a replacement unit is required as soon as possible. With this service, the unit will be shipped in the fastest manner consistent with the urgency of the situation. In most cases, there are no charges for in-warranty repairs, except for the transportation charges of the unit and for a testing and handling charge for units returned with no trouble found. Upon receipt of the advanced replacement unit, return the out-of-service unit in the carton in which the replacement was shipped, using the preaddressed shipping label provided. Call your customer service representative at the telephone number above for more details.

Section 855-180-201 8.4 Standard Repair and Replacement Service (Both In-Warranty and Out-Of-Warranty Units) Charles Industries, Ltd. offers a standard repair or exchange service for units either in- or out-of-warranty. With this service, units may be shipped to Charles Industries for either repair and quality testing or exchanged for a replacement unit, as determined by Charles Industries. Follow the Repair Service Procedure below to return units and to secure a repair or replacement. A handling charge applies for equipment returned with no trouble found. To obtain more details of this service and a schedule of prices, contact the CI Service Center at 217-932-5288 (FAX 217-932-2943). Repair Service Procedure 1. Prepare, complete, and enclose a purchase order in the box with the equipment to be returned. 2. Include the following information: Company name and address Contact name and phone number Inventory of equipment being shipped Particulars as to the nature of the failure Return shipping address 3. Ship the equipment, purchase order, and above-listed information, transportation prepaid, to the service center address shown below. CI Service Center 503 N.E. 15th St., P.O. Box 339 Casey, IL 62420-2054 U.S.A. 4. Most repaired or replaced units will be returned within 30 or 45 days, depending on the product type and availability of repair parts. Repaired units are warranted for either 90 days from the date of repair or for the remaining unexpired portion of the original warranty, whichever is longer. 9. SPECIFICATIONS 9.1 Electrical The electrical characteristics of the 8551-80 Power Supply is as follows: (a) INPUT VOLTAGE: 95 250Vac, 47 63 Hz, single-phase. (b) INPUT POWER: 270W at 120 Vac, 300W at 230 Vac. (c) OUTPUT VOLTAGE: 48 +/ 0.5 Vdc. (d) OUTPUT CURRENT: 2.5A maximum. (e) OUTPUT POLARITY: Floating; either positive or negative terminal may be grounded. (f) RIPPLE: Less than 0.5V peak-to-peak. (g) NOISE: Less than 0.5V peak to peak. (h) OVERLOAD PROTECTION: Current foldback, protects the power supply from damage if the output is shorted. (i) AC FUSE: 250VAC, 4A, Slow Blow, 5x20mm 9.2 Physical The physical characteristics of the 8551-80 Power Supply are shown in Table 1:

Table 1. Physical Specifications Feature U.S. Metric Height 1.73 inches 4.4 centimeters Width (with flanges) 19 or 23 inches 48.26 or 58.42 centimeters Depth 4.33 inches 24.77 centimeters Line Cord (nominal, 3 conductors) 6 feet 1.83 meters Weight 3.9 pounds 1.7 kilograms Temperature 14 to 140 F 10 to 60 C Humidity To 95% (no condensation)