C9900-P208 and C9900-P209

Similar documents
C9900-P223 and C9900-P224

Installation and Operating instructions for Control Cabinet PC C6915

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Installation and Operating instructions for C / Fanless Control Cabinet Industrial PC. Version: 1.0 Date:

Installation and Operating instructions for. Control Cabinet Industrial PC C from Version: 2.0 Date:

Installation and Operating instructions for. Control Cabinet PC C6210. Version: 1.4 Date:

Installation and Operating instructions for Industrial PC series C61xx from Version: 3.0 Date:

Installation and Operating instructions for. Control Cabinet PC C6240 from Version: 2.0 Date:

Installation and Operating instructions for Industrial PC series C61xx up to Version: 2.6 Date:

Control Cabinet Industrial PC C6640/ C6650 up to -0030

Installation and Operating instructions for. Control Cabinet PC C6250 up to Version: 1.6 Date:

Installation- and Operating instructions for. Build-in Industrial PCs C3620, C3640 from Version: 3.0 Date:

Installation and Operating instructions for Built-in Industrial PC C6525

Installation and Operating instructions for Control Cabinet PCs C63xx

Installation and Operating instructions for C Ultra compact Industrial PC. Version: 1.3 Date:

Installation- and Operating instructions for CU CFast card adapter with USB connector. Version: 1.1 Date:

CU port USB 2.0 hub. Version: 1.1 Date:

19-inch slide-in Industrial PC C5210

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Installation and Operating instructions for Industrial PC series C61xx

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Installation and Operating instructions for. C inch slide-in Industrial PC. Version: 1.0 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Installation and Operating instructions for. CP27xx. Fanless multi-touch built-in Panel PC. Version: 1.0 Date:

Installation and Operating instructions for. Economy built-in Panel PC CP62x9. Version: 1.0 Date:

Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5102 from -0060

Documentation. Mains filter AX2090-NF50. Version: Date:

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Installation- and Operating instructions for CU CP-Link 4 transmitter box The Two Cable Display Link. Version: 1.

Installation and Operating instructions for. Built-in Control Panel CP6608. Version: 1.0 Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Installation and Operating instructions for Build-in Industrial PC C33xx up to -0050

CU Compact-Flash card adapter for USB. Version: 1.0 Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Installation and Operating instructions for CP / CP Economy Built-in Panel PC. Version: 1.

Installation and Operating instructions for CP / CP Economy Built-in Panel PC. Version: 1.

Installation and Operating instructions for. CP79xx Control Panel. Version: 1.5 Date:

Installation and Operating instructions for. CP37xx. Multi-touch Panel PC. Version: 1.2 Date:

Description AX5805. List of permissible motors. Version: Date:

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

Installation and Operating instructions for. CP32xx. Multi-touch Panel PC. Version: 1.7 Date:

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

Installation and Operating instructions for. Panel-PC CP71xx. Version: 1.4 Date:

Installation and Operating instructions for. CP790x-140x. IP65 Stainless Control Panel. Version: 1.1 Date:

CP29xx-0010 Multi-touch Control Panel with CP-Link 4 interface

Installation and Operating instructions for. Built-in Panel PC CP63xx. Version: 1.4 Date:

Documentation for. TwinSAFE User. Tool to modify the User Administration of a TwinSAFE Logic. Version: Date:

Description AX5805. Default values for the permissible motors. Version: Date:

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

Installation and Operating instructions for. CP69xx. Built-in Control Panel with DVI/ USB Extended interface. Version: 2.

CP39xx-0010 Multi-touch Control Panel with CP-Link 4 interface

Installation and Operating instructions for CP78xx Control Panel. Version: 1.8 Date:

Documentation. KL2784 und KL2794. Four channel digital output terminals with MOSFET transistors. Version: Date:

EL9820/EL9821 Evaluation Kit. Version: 1.3 Date:

Installation and Operating instructions for. CP79xx Control Panel. Version: 1.2 Date:

Installation and Operating instructions for. Built-in Control Panel CP68xx. Version: 2.0 Date:

Installation and Operating instructions for Control Panel CP77xx. Version: 1.6 Date:

Operation Manual BK5000. Bus Coupler for CAN-CAL Version: 1.12

Application Note FC1100/FC1121 (EtherCAT Slave Card)

Application Note FC1100/FC1121 (EtherCAT Slave Card)

Manual CX Audio interface for CX20x0. Version: Date:

TC3 Interface for Matlab /Simulink

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Manual. PLC Lib: Tc2_SMI. TwinCAT 3. Version: Date:

CPCI-PS24 24V-Power Supply

Documentation. FC7501 and FC7502. SERCOS interface PCI Cards. Version: Date:

Manual. TwinCAT MC Flying Saw. TwinCAT 3. Version: Date: Order No.: TF5055

Documentation. FC2001 and FC2002. Lightbus PCI Interface Cards. Version: Date:

Manual. PLC Lib: Tc2_DMX. TwinCAT 3. Version: Date:

Manual. PLC Lib: Tc2_DataExchange. TwinCAT 3. Version: Date:

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Manual. PLC Lib: Tc2_Standard. TwinCAT 3. Version: Date:

Manual. TC3 Virtual Serial COM. TwinCAT 3. Version: Date: Order No.: TF 6360

Installation instructions Ethernet switch EC / / 2011

Manual. Software Protection. TwinCAT 3. Version: Date:

Broadband Automatic Disconnect Switch. User Manual

Operating manual ELX9012, ELX9410, ELX9560. ELX System Terminals. Version: Date:

Documentation. KL28xx. HD Bus Terminals, digital output 24 V DC. Version: Date:

3M RFID Tracking Pad Model 770

Manual. PLC Lib: Tc2_DataExchange. TwinCAT 3. Version: Date:

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Documentation KL2602, KL2622. Two-channel Relay Output Terminals. Version: Date:

Manual. PLC Lib: Tc2_Coupler. TwinCAT 3. Version: Date:

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

4170 POS System Installation Guide

Manual. TC3 EtherCAT Simulation. TwinCAT 3. Version: Date: Order No.: TE1111

icore Kiosk system Installation Guide

Operating instructions for KL2904. TwinSAFE output terminal with 4 fail-safe outputs. Version: Date:

MC 11 EB-2 Power supply cabinet with external bus, AC version

EL9800 Base Board. Version: 1.9 Date:

Installing and Configuring Rialto Analytic Appliances

Operation Manual for. EJ19xx and EJ29xx. TwinSAFE EJ Modules with digital fail-safe in and outputs. Version: Date: 1.2.

Manual. TC3 Power Monitoring. TwinCAT 3. Version: Date: Order No.: TF3650

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Manual. PLC Lib: Tc2_Drive. TwinCAT 3. Version: Date:

Transcription:

Installation and Operating instructions for C9900-P208 and C9900-P209 Power Supply Units Version: 1.5 Date: 2012-02-22

Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability Conditions 2 Trademarks 2 Patent Pending 2 Copyright 2 State at Delivery 2 Delivery conditions 2 Description of safety symbols 3 Basic safety measures 4 Operator's obligation to exercise diligence 4 2. Product Description 5 Appropriate Use 5 Beckhoff power supply technology 5 Electrical data 6 3. Installation Instructions 7 Configuration and installation 7 Connection with the motherboard Pin assignment of the pin strips 8 8 Connection with the Industrial PC 9 Pin assignment of the connector 9 Preparing the cable harness 10 External wiring 10 Cable Cross Sections 10 Power supply of the Industrial PC 11 Configuration for shutting down the PC 11 PC_ON and Power Status functions 11 UPS output, C9900-P209 only 12 UPS output function 12 Wiring diagram 13 Installation of the supply cables Connector installation 14 14 4. Operating Instructions 15 UPS Software Components (only C9900-P209) 15 Installation on the PC 15 Help files 15 Servicing 15 Shutting down Disposal 15 15 5. Assembly dimensions 16 6. Troubleshooting 17 Beckhoff Support & Service 17 Beckhoff branches and partner companies 17 Beckhoff Headquarters 17 Beckhoff Support 17 Beckhoff Service 17 7. Appendix 18 Technical data 18 Approvals 18 FCC: Federal Communications Commission Radio Frequency Interference Statement FCC: Canadian Notice 18 18 C9900-P208 / C9900-P209 1

Foreword Foreword Notes on the Documentation This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components. The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards. Liability Conditions The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation. Trademarks Beckhoff, TwinCAT, EtherCAT, Safety over EtherCAT, TwinSAFE and XFC are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners. Patent Pending The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or registrations in various other countries. The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries. Copyright Beckhoff Automation GmbH. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. State at Delivery All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH apply. 2 C9900-P208 / C9900-P209

Foreword Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. Acute risk of injury!! DANGER If you do not adhere the safety advise adjoining this symbol, there is immediate danger to life and health of individuals! Risk of injury! WARNING If you do not adhere the safety advise adjoining this symbol, there is danger to life and health of individuals! Hazard to individuals! CAUTION If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to individuals! Hazard to devices and environment Attention If you do not adhere the notice adjoining this symbol, there is obvious hazard to materials and environment. Note or pointer Note This symbol indicates information that contributes to better understanding. C9900-P208 / C9900-P209 3

Foreword Basic safety measures Use only with Beckhoff Industrial PCs Note The power supply unit must only be used in conjunction with Beckhoff Industrial PCs! Switch off the power supply of the system during installation! Attention During assembly, removal and electrical wiring of the power supply unit, the power supply of the system must be switched off in order to prevent damage on the power supply unit and the Industrial PC. Items of equipment that have been switched off must be secured against being switched on again. Do not open the power supply unit while voltage is applied! WARNING The supply voltage must be switched off before the power supply unit housing is opened. Operator's obligation to exercise diligence Only appropriately trained staff may install the power supply unit! CAUTION The operator must ensure that only appropriately trained electricians deal with installation and wiring of the power supply unit. 4 C9900-P208 / C9900-P209

Product Description Product Description Appropriate Use The C9900-P208 and C9900-P209 power supply unit provide the power supply for Beckhoff Industrial PCs. The C9900-P209 power supply in conjunction with a C9900-U330 battery pack allows the construction of an uninterruptible power supply (UPS). Risk of explosion! WARNING Risk of explosion if other battery packs are used! Beckhoff power supply technology Schematic diagram of power supply unit wirings Innovative solution for shutting down Industrial PCs Industrial PCs equipped with a UPS are in actual use frequently switched off by simply turning off the supply voltage. In this case the PC shuts down via the battery. However, over time this reduces the service life of the battery. The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery. In addition to the main switch this innovative solution uses an ON/OFF switch for the machine. Basically, the main switch remains switched on and provides the power supply for the PC during shutdown. Via the PC ONinput of the power supply the PC gets the command to shut down the operating system. Once the PC has shut down, the PC power supply unit sets the Power Status-output (P-S) to 0, what indicates that the process is complete and that the main voltage can be switched off. This can be done manually via a signal lamp connection or via a contactor. With this solution the main switch generally only has to be switched off if the control cabinet has to be opened. The battery will only be used in the event of a power failure. C9900-P208 / C9900-P209 5

Product Description In order to maintain a screen display for the Industrial PC in the event of a power failure, the C9900-P209 power supply unit is equipped with a UPS output 27 V / 1.4 A for connecting a Control Panel with a display dimension up to 19 inches. This enables a power failure to be visualized and displayed to the user. Once the PC has shut down, the UPS output is switched off. For a detailed functional description please refer to section External wiring. Electrical data Input voltage: Power output: 22-30V DC/ 15A 250W (max.) Output voltages: + 5V 14A + 12V 12A + 3.3V 12A - 5V 0.3A - 12V 0.5A + 5VSB 1.5A 6 C9900-P208 / C9900-P209

Installation Instructions Installation Instructions View of the power supply unit Configuration and installation 1 2 The power supply unit is installed at the prescribed position in the Industrial PC. The supply connections for the power supply unit are located next to the fan (1). The electrical connections for the motherboard are on the opposite side (2). C9900-P208 / C9900-P209 7

Installation Instructions Pin strips on the output side Connection with the motherboard 1 2 3 4 5 Connection with the motherboard The power supply unit is connected with the motherboard according to the installation instructions of the board. Connection Function 1 ATX interface 2 5V/12V supply 3 POWER ON 4 COM interface 5 12V supply Pin assignment of the pin strips ATX DC output 5V/ 12V supply for drives POWER ON COM interface (RS 232) ATX 12V DC-Output Pin Function Pin Function 1 3.3V 11 3.3V 2 3.3V 12-12V 3 GND 13 GND 4 + 5V 14 PS ON 5 GND 15 GND 6 + 5V 16 GND 7 GND 17 GND 8 PWR OK 18-5V 9 5VSTB 19 + 5V 10 12V 20 + 5V Pin Function Pin Function 1 + 12V 5 + 12V 2 GND 6 GND 3 GND 7 GND 4 + 5V 8 + 5V Pin Function 1 POWER-ON 2 POWER-ON Pin Function 3 TXD 5 RXD 9 GND Pin Function Pin Function 1 GND 3 + 12V 2 GND 4 + 12V 8 C9900-P208 / C9900-P209

Installation Instructions Connection with the Industrial PC The power supply unit features an 8-pin contact strip for connecting the power supply unit inside the Industrial PCs with the respective connection sockets for power supply switch and battery pack (C9900-P209 only). In addition, the C9900-P209 power supply unit features a UPS output for connecting a Control Panel. Pin strips Input 24V DC UPSoutput 7 6 5 4 3 2 1 1 2 Uninterruptible power supply (UPS) Note With the C9900-P209 power supply you can realize an uninterruptible power supply (UPS) using the battery pack C9900-U330. Risk of explosion! WARNING Risk of explosion if other battery packs are used! A Control Panel can be connected to the UPS output of the C9900-P224. The maximum current loading is 1.4 A. Pin assignment of the connector The power supply and the external circuit for switching the Industrial PC on and off are connected via the plug connector. Pin assignment for connecting the switch, the power supply and the battery pack (optional) Input 24V DC: Pin Function 1 - Battery Pack 2 + (C9900-P209 only) 3 4-24 V DC Power Supply 5 + 6 Power-Status 7 PC_ON Pin assignment for connecting a control panel (optional) UPS-output (C9900-P209 only): Pin Function 1 UPS- UPS-output 2 UPS+ C9900-P208 / C9900-P209 9

Installation Instructions Preparing the cable harness A wiring harness is used for connecting the power supply unit with the connection sockets in the Industrial PC. Due to different cable lengths, the harness is produced individually for each type of computer. The wiring diagram section shows the connection between the 7-pin power supply unit connector and the 3-pin and 5-pin pin strip at the PC case: Cable harness wiring diagram Insert fuse Attention Note cable cross sections The power supply of the customized components for shutting down the PC must be protected with a fuse! To this end, a "flying" fuse (6.3A/ medium time-lag) is inserted in the line. The cable cross sections are 0.75 mm 2 / AWG18 for connecting the switch and 2.5 mm 2 / AWG14 (screened) for connecting the power supply. External wiring The external wiring consists of the connection of the power supply, the battery pack (only C9900-P209) and the connection of customized components for shutting down the PC. The external wiring occurs according to the wiring diagram, see chapter Wiring diagram. Note cable cross sections, avoid voltage drop! Cable Cross Sections For the connection of the power supply, wiring with a cable-cross-section of 1.5 mm 2 must be used. With bigger distances between voltage source and PC, you take the voltage drop as a function of the cable-cross-section as well as voltage fluctuations of your distribution voltage into account, so that is secured that the voltage doesn't fall under 22 V at the power supply. Insert fuse Attention The power supply must be protected with 16 A. 10 C9900-P208 / C9900-P209

Installation Instructions Power supply of the Industrial PC The 5-pin pin strip with CAGE CLAMP connection and mounting flanges shown on the photograph is mounted on the PC case for connecting the power supply and the battery pack. Pin assignment for connecting the power supply and the battery pack 5 4 3 2 1 Pin Function 1 + 24 V DC Power Supply 2-3 4 + Battery Pack 5 - (C9900-P209 only) Configuration for shutting down the PC Pin assignment for connecting the on/off switch The connections for shutting down the Industrial PCs are established via the PC_ON input and the Power Status output. The third contact is connected to 24 V. To this end, a 3-pin pin strip with CAGE CLAMP connection and mounting flanges is installed at the PC case. 3 2 1 Pin Function 1 Power-Status 2 PC_ON 3 + 24 V PC_ON and Power Status functions If the PC_ON input is connected to 24 V via a switch, the PC shuts down according to the rules. The PC_ON signal is inverted, i.e. the PC shuts down if the 24 V connection is live. If the PC_ON input is NOT connected by the user, the PC can be booted in the familiar way by connecting the supply voltage and shut down via the battery by switching off the supply voltage. Service life of the rechargeable battery Attention This procedure significantly reduces the service life of the rechargeable battery and should therefore not be used. Once the PC has shut down, the Power Status output is switched from 24 V to 0 V. Via this output a signal lamp can be connected or a contactor for de-energizing the whole system. The maximum load for the Power Status output is 0.5 A and a suitable fuse should be provided. C9900-P208 / C9900-P209 11

Installation Instructions UPS output, C9900-P209 only In order to maintain a screen display for the PC in the event of a power failure, the C9900-P209 power supply unit is equipped with a UPS output for connecting a Control Panel. The maximum load for the output is 1.4 A. The UPS output is located on the power supply unit adjacent to the mains plug (see also section Product Description). UPS output function The 27 V DC connection at the UPS output is live even after a power failure. The maximum load is 1.4 A (C9900-P209 only). Once the PC has been de-energized via the UPS software, the UPS output is switched to 0 V. Any connected panel is thus switched off, and total discharge of the rechargeable battery is prevented. 12 C9900-P208 / C9900-P209

Installation Instructions Wiring diagram Wiring according to the wiring diagram. The circuit of PC_ON and Power-Status is symbolical. Connection of the Battery Pack and UPS Output Note Connection of the Battery Pack and UPS Output only in combination with C9900-P209 power supply. C9900-P208 / C9900-P209 13

Installation Instructions Installation of the supply cables Wiring according to the wiring diagram Install the cables for the power supply of the Industrial PC, the connection of the battery pack and the connection of the illuminated toggle switch according to the wiring diagram using the connector assembly material provided. Connector assembly is described using the example of the 5-pole female plug connector: Materials for assembly of the connector A B C D Female plug connector, 5-pole Strain relief housing Fitting the connector to the cable Applying the strain relief Connector installation The plug is fitted to the cable as follows: 1. Remove the insulation from the cable ends (8-9 mm). 2. Push the cable into the holders, applying slight pressure according to the pin assignment label and the wiring diagram. 3. Push the lower part (part A) of the strain relief housing onto the top of the female plug connector until it snaps into place. 4. Relieve the strain on the supply cable by fixing it in place with the cable clamp (part C) and fixing screws (part D) (see photograph below). Fix the upper part (part B) of the strain relief housing by snapping it onto the lower part. 14 C9900-P208 / C9900-P209

Operating Instructions Operating Instructions UPS Software Components (only C9900-P209) Installing the UPS driver software For operating the power supply unit as a UPS, the UPS driver software and the associated UPS driver must be installed on the Industrial PC. On delivery of the Beckhoff Industrial PC with operating system the software is already installed. Should the software not be installed on your PC, the drivers can be installed from the driver CD provided. Installation Installation on the PC To install the UPS driver software, execute file Beckhoff_UPS_vx.xx.xx.exe from the subdirectory of UPS\ from the CD provided on the Industrial PC (Driver-archive for the Industrial-PC, C9900-S700-xxxx). The program is self-extracting and will guide the user through the installation routine. Beckhoff Information System Help files The driver software comes with a detailed help function. The help files can be called up either directly from the configuration register by clicking the Help button, or under via Start > Programs > Beckhoff > UPS software components. Servicing The power supply unit is maintenance-free. Shutting down Dismantling the case Observe national electronics scrap regulations Disposal The device must be fully dismantled in order to dispose of it. The housing can be sent for metal recycling. Electronic parts must be disposed of in accordance with national electronics scrap regulations. C9900-P208 / C9900-P209 15

Assembly dimensions Assembly dimensions Device dimensions and mounting points. Dimensional notation in mm. 16 C9900-P208 / C9900-P209

Troubleshooting Troubleshooting In the event of a fault contact your Beckhoff Service. Beckhoff Support & Service Beckhoff and their partners around the world offer comprehensive support and service, guaranteeing fast and competent assistance with all questions related to Beckhoff products and system solutions. Beckhoff branches and partner companies Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com You will also find further documentation for Beckhoff components there. Beckhoff Headquarters Beckhoff Automation GmbH Eiserstraße 5 33415 Verl Germany Phone: +49(0)5246/963-0 Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Beckhoff offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with wideranging services: worldwide support design, programming and commissioning of complex automation systems training program for Beckhoff system components Hotline: +49(0)5246/963-157 Fax: +49(0)5246/963-9157 e-mail: support@beckhoff.com Beckhoff Service The Beckhoff service center supports you in all matters of after-sales service: on-site service repair service spare parts service hotline service Hotline: +49(0)5246/963-460 Fax: +49(0)5246/963-479 e-mail: service@beckhoff.com Quote the project number If servicing is required, please quote the project number of your product. C9900-P208 / C9900-P209 17

Appendix Appendix Technical data Electrical data Input voltage: 22-30V DC/ 15A Power output: 250W (max.) Output voltages: see section Electrical data Dimensions Dimensions (W x H x D): 97.0 x 44.0 x 204.9 mm Weight: 0.85 kg Do not use the power supply unit in areas of explosive hazard The power supply unit must not be used where there is a risk of explosion. The following conditions must be observed during operation: Environmental conditions Ambient temperature: 0 to 55 C Atmospheric humidity: Maximum 95%, non-condensing Shock resistance Sinusoidal vibration (EN 60068-2-6): 10 to 58 Hz: 0.035 mm 58 to 500 Hz: 0.5 G (~ 5 m/ s 2 ) Impact (EN 60068-2-27/ -29): 5 G (~ 50 m/ s²), duration: 30 ms EMC compatibility Resistance to interference: according to EN 61000-6-2 Transport and storage Emission of interference: according to EN 61000-6-4 The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. The shock resistance during transport can be improved by appropriate packaging of the power supply unit. The ambient temperature during storage and transport must be between -20 C and +65 C. Approvals FCC Approval for USA FCC Approval for Canada FCC: Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC: Canadian Notice This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. 18 C9900-P208 / C9900-P209