FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

Similar documents
FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

PROCESS AUTOMATION. Manual KF!!-UFT-(EX)2.D ROTATION DIRECTION INDICATOR AND CONSTANT SPEED MONITOR

0DQXDO.& &9 6 6 & 3UHVHWWLQJ FRXQWHUV FACTORY AUTOMATION

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

MANUAL PCV Parameterization Tool

Amplifiers, Counters, Timers & Controls

FACTORY AUTOMATION. MANUAL R CANopen Protocol

FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT

QUICK START GUIDE IC-KP2-*

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

MANUAL Encoders with J1939 Interface

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

PROCESS AUTOMATION. Manual KFD2-UT-EX1 CONVERTER. pepperl_fuchs barriers

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

02/11/2015

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface

PROCESS AUTOMATION PROZESSAUTOMATION HANDBUCH MANUAL FREQUENCY CONVERTER HID2891 ISO9001

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

Universal counter UZ 9648 Counting - length measurement - metering - positioning

FACTORY AUTOMATION. QUICK START GUIDE OHV200-F22*-B15 Handheld reader

MANUAL Functional Safety

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

Table of Contents. AS-i Modbus Plus-Gateway Table of Contents. 1 Declaration of Conformity The Used Symbols...6

SAFETY MANUAL SIL Switch Amplifier

FACTORY AUTOMATION. M18 Threaded light beam switches

FACTORY AUTOMATION. PROGRAMMING SOFTWARE VisoSetup

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES

Displays Transducers. Displays and transducers

OPERATING INSTRUCTIONS

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

FACTORY AUTOMATION. MANUAL VBA-4E3A-G20- ZEL/M1L-P2 AS-Interface Motor Control Module

QUICK START GUIDE 2-D Laser Scanner

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

Speed indicator DR 1010 Revolution per minute - speed - flow

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Contact protection relay

QUICK START GUIDE ODT-HH-MAH300 Handheld

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

Compact Speed Monitoring and Overspeed Protection System

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

FACTORY AUTOMATION. Instruction Manual PROFIBUS VB3X

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

FACTORY AUTOMATION MANUAL VBP-HH1-V3.0-V1

MANUAL Functional Safety

Speed Controller ZSU A01

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

FACTORY AUTOMATION MANUAL CBX800

Issue 03/2013. The Electronic Load

Operating instructions. Monitor FD / / 2013

MANUAL Functional Safety

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

02/11/2015

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

FACTORY AUTOMATION. Manual Absolute Rotary Encoder for DeviceNet

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

MANUAL Functional Safety

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

SWT-2000 Frequency Measurement and Switching Instrument Operating Manual

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

SWTD-1000 Speed Switch / Transmitter Operating Manual

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

MANUAL Surge Protectors

FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

02/11/2015

MANUAL IPT*-FP with U-P*-RX

DINALOG A 144 x 36 A1400 Light-Strip Indicator

QUICK START GUIDE ODT-MAC40*-*-RD

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer

PROCESS AUTOMATION. QUICK START GUIDE FieldConnex Diagnostic Manager

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Valve Position Indicators

Operating instructions. Standstill monitor A / / 2011

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Transcription:

FACTORY AUTOMATION Manual Speed Monitor KFU8-DW-.D

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the "Elektrotechnik und Elektroindustrie (ZVEI) e.v. in their most recent version as well as the supplementary clause: "Extended reservation of title". We at Pepperl+Fuchs recognise a duty to make a contribution to the future, For this reason, this printed matter is produced on paper bleached without the use of chlorine.

Table of contents Technical description.......................................2 2 Operation.................................................4 2. Operating mode................................................... 4 2.2 Setting mode..................................................... 5 3 Technical data............................................ 4 Terminal assignment.......................................2 5 Dimensions, operating and display devices....................2 6 Connection plan...........................................3 7 Function description overview...............................4 Date of Issue 24-8-23

Technical description Technical description The KFU8-DW-.D is a device used to indicate and monitor periodic signals which occur in almost all areas of automation and process engineering, i.e. frequencies in general and rotational speeds in particular. The input signals are evaluated using the cycle method, i.e. by measuring the duration of a period, and then converted by a very fast m-controller to frequency, or rotational speed. The frequently occuring special case of rotational speed measurement was given particular attention. For this reason, indications and inputs can be either in Hz or in rpm. In addition, the possibility exists, on applications involving lengthy processes, whose sensors provide a number of pulses per revolution, to operate automatically with the actual rotational speed of the drive, by presetting the number of pulses. Indication of the measured value is achieved by means of a 4-digit 7-segment-LEDdisplay on the front of the device, with up to 3 places following the decimal point. The monitoring function is actuated by a limiting value, whose upper and lower hysteresis values can be selected within the appropriate measuring and indicating range. The output signal is generated by a change-over relay when the hysteresis limits are either exceeded or fallen below. Due to its high switching capability, the relay output can be used to directly drive an actuator, or as an input signal to a higher level control. In addition, the switching state of the relay is indicated by a yellow LED on the front face of the device. A function block is connected in line with the output relay, which enables different timer functions to be employed; thus there is no need to connect a separate timer relay in series. In addition to ON delay and OFF delay, defined ON time and pulse lengthening, the direction of operation of the relay, i.e. to monitor underspeed or overspeed, can also be selected. The built-in start-up bypass, triggered by switching on the supply voltage, or by an external signal, prevents false signals from occuring during the start-up of the monitored system. The speed monitor may be supplied with 5 V AC, 23 V AC or 24 V DC. When an alternating voltage is connected, a 24 V DC source is available for the signal transducer. All currently available two-, three- or four-wire proximity switches and incremental rotary encoders are accepatable as the sensor. Moreover two terminals are reserved for the connection of proximity switches to DIN 9234 (NAMUR). Date of Issue 24-8-23 2

Technical description Safety notes: Insulation co-ordinates for specifying data on galvanic/electrical isolation are in accordance with DIN EN 578: The KFU8-DW-.D device is intended for use in enclosed electrical operating areas, to which only competent electrical personnel or properly instructed electrotechnical personnel have access or entry. The device is rated for use in conditions of pollution severity class 2, overvoltage category II in accordance with EN 578. The device comprises 3 galvanically isolated circuits: 23 V, 5 V voltage supply circuit, connections: 6, 7, 8 Signal circuit 24 V voltage supply, connections: 4, 5 Sensor/signal, connections:, 2, 3, 7, 8, 9, 3, 4, 5 Relay output circuit, connections:,, 2 There is no isolation between the signal circuit connections and the exposed/ contactable surfaces. Date of Issue 24-8-23 3

Operation 2 Operation 2. Operating mode Signal frequency The speed monitor processes input signals from. Hz... 5 Hz, over 4 measuring ranges, i. e., cycle durations of.2 s to s are evaluated. Signals not having a duty rate of : must have a minimum pulse pause or pulse duration of 2 µs in order to be detected with certainty behind the input filter. Signal has fallen below the measuring range, message This message appears either when no input signal is detected, or if the displayed value would be zero, due to the selection of a measurring range which is too high. Example: The device receives a signal of. Hz in the Hz to 5 Hz measuring and display range. This implies that the display would indicate zero and an observer might presume that the machine had stopped. Signal is above the measuring range, message The set display and measuring range has been exceeded. Solution: Select a larger measuring range. Very low signal frequencies, displayed value is not valid, message During the measurement of very low signal frequencies, the measuring system has detected that the signal has fallen below the last computed frequency, i.e., the time between the last two signal edges has already elapsed. The unit is now waiting for the next positive signal edge, in order to be able to compute the next measured value. Here, 'XXX' represents the positions of the first three digits of the last measured value. Self test, message When the supply voltage is switched on, the speed monitor carries out a self test. The message appears when it is established that there is an error, for example during the check summation of the EEPROM data; in this state, the output relay behaves as if there has been a power failure. The error message can be cleared by switching the supply voltage off and then on again. If, on switching on again, the error message U- appears, then the factory presets were loaded, i.e., the parameters must be newly entered. In order to restore the normal function of the output relay, the speed monitor must once again be switched off and then on. Date of issue 23-2-8 4

Operation 2.2 Setting mode (see also the operating summary on the fold-out page) Password protection The password protection function is not active. The password can be displayed, but not changed. Function selection Two measuring functions are available:. Frequency measurement in Hz The period of duration of the input signal, as determined, is converted to a frequency in Hz by forming the reciprocal value and then displayed. The hysteresis limits of the switch point are also specified in Hz. 2. Rotational speed measurement in rpm (preset at the factory) The signal frequency, derived from the period of duration, is multiplied by 6 and displayed as rpm. The hysteresis limits are likewise specified in rpm. Pulse divider (Preset at the factory: pulse/revolution) Applications involving slow processes are frequently equipped with sensors which provide several pulses per revolution. In the rotational speed measuring function, the device undertakes the conversion to the actual value of rpm by inputting the numerical value (of pulses/revolution), i.e. both the indication and the input of the hysteresis limits are directly obtained from the actual rate of rotation of the drive. Example: In normal operation, a machine rotates at 45 rpm. An incremental rotary encoder providing pulses per revolution is used as the rate of rotation sensing element. The input frequency is 45 rpm x pulses per revolution 6 s/min = 75 Hz A rate of rotation of 45 rpm x pulses/revolution = 45 rpm would be displayed in the rotational speed measuring function. By programming the pulse divider to pulses/revolution, the display would indicate the actual drive speed of 45 rpm. Date of issue 23-2-8 5

Operation Display and measuring range (Preset at the factory:... 999.9) Four measuring and display ranges are available for frequency measurement and three measuring and display ranges are available for speed measurement, as follows: Display in parameter editor Frequency range in Hz Rotational speed in rpm Number of decimal places... 5... 9999.,... 999,9.2,... 99,99 2.3,... 9,999 ---- 3 Example (continued from above): The maximum permissible rotational speed of the drive is 6.5 rpm. The first two measuring ranges can be selected. However, in order to fully utilise the accuracy of the display, it is recommended that the second measuring range is used. Message This message appears when an attempt has been made to change the range in such a way, that previously input limiting values lie outside the display and measuring range, or the respective places following the decimal point would be cut off. Example (continued from above): The maximum permissible value of 6.5 rpm has already been input as the upper hysteresis limit, and an attempt is being made to change the range to. rpm to 99.99 rpm (the limiting value is outside the display and measuring range), or an attempt is being made to change the range to rpm to 9999 rpm (places following the decimal point would be cut off). Output relay switch points (Preset at the factory: and 2) The output relay switch points are defined by the upper and lower hysteresis limit. When the upper hysteresis limit O_Gr is exceeded, switching is triggered and on falling below the lower hysteresis limit U_Gr, switch back occurs. If no hysteresis limit is desired, i.e., the output relay is required to switch both on and off at a defined rpm, the same value has to be input for both parameters. Example (continued from above): On exceeding the maximum permissible rotational speed of 6.5 rpm, a signal should be activated in the control room. The alarm message should then extinguish when the speed drops again to 5 rpm. The upper hysteresis limit is to be set at 6.5 rpm, the lower at 5 rpm. Date of issue 23-2-8 6

Operation Message The message GrU? appears if an attempt is made to set a value for the upper hysteresis limit which is lower than the lower hysteresis limit and GrO? is displayed on an attempt to programme a value for the lower hysteresis limit which is larger than the upper hysteresis value. Timer functions, reversal of direction of operation of the output relay Time base for the timer functions (Preset at factory:. s) A time between. s and 999.9 s can be set for the timer function of the output relay. Timer functions and reversal of direction of operation (Preset at factory: ) The KFU8-DW-.D speed monitor can be adjusted to any one of different settings, in association with the reversal of direction of operation, in order to modify the switching behaviour of the output relay. In functions to 4, the output relay is active according to the selected time function, when the upper hysteresis value is exceeded. In functions 5 to 9 the sense of operation is inverted, i.e., the relay is active below the lower hysteresis limit. No. Function No. Function no timer function 5 no timer function, inverted ON delay 6 ON delay, inverted 2 OFF delay 7 OFF delay, inverted 3 Defined ON time 8 Defined ON time, inverted 4 Pulse lengthening 9 Pulse lengthening, inverted The ON delay has the effect of causing the timer to start when the upper hysteresis limit is exceeded and the relay to be triggered (retriggerable) when the timer has run out. The OFF delay causes the relay to operate immediately when the upper limiting value has been exceeded. Each time the measured parameter falls below the lower limit the timer is started and as soon as the timer has run out the relay drops out (retriggerable). Defined ON time implies that the relay pulls in when the upper hysteresis limit is exceeded and drops out again after the set time (not retriggerable), independently of further variations in rpm. Date of issue 23-2-8 Pulse lengthening is the means of providing that the relay pulls in when the upper limit is exceeded and drops out as soon as possible when the set time has elapsed (not retriggerable). (See also the graphical representation on page 7). 7

Operation Start-up bypass (Preset at factory: 3 s) A start-up bypass time between. s and 999.9 s can be programmed in order to avoid false signals on the start-up of a drive which is to be monitored for underspeed. During this time the device and the output relay behave as if the machine had already exceeded the upper hysteresis limit. The start-up bypass time is started by a positive signal on terminal 2; the positive signal must be at least as long as the bypass time. The start signal can originate from a higher order control, or be generated by the connection of the supply voltage to the speed monitor. In the latter case, terminals 2 and 3 have to be bridged. Example: In normal operation, a machine requires a maximum of 5 s to run up to a nominal speed of 5 rpm. The start-up bypass time has to be set to a value greater than 5 s. When the period of 5 s has elapsed the rpm underspeed monitoring function is active (relay function 5). If the start-up is as scheduled during this time, the relay will not have actuated. If the start-up takes longer than anticipated, then the relay will switch after commencement of the start-up bypass, until the upper hysteresis limit has been reached. Display rate (Preset at factory:.33 s) In order to ensure good readability of the display, the time taken to indicate the current measured value in the display can be selected between. s and 2.5 s. Software version number The number of the software version can be read only. Date of issue 23-2-8 8

Operation tstart-up 2 3 4 5 6 7 8 Date of issue 23-2-8 9 Figure: Timer functions, reversal of direction of action of the output relay 9

Operation Date of issue 23-2-8

Technical data 3 Technical data Supply voltages 3 V AC ± %, 47 Hz... 63 Hz, < 5 VA (Terminal 6, 8) 5 V AC ± %, 47 Hz... 63 Hz, < 5 VA (Terminal 7, 8) 24 V DC +5/- %, U ss %, < 5 W (Terminal 4, 5) Date of issue 23-2-8 Signal inputs Frequency, Hz... 5 Hz Minimum pulse length/duration: 2 µs NAMUR Switch points:.2 ma; 2. ma (Terminal 8, 9) No load voltage: 8.2 V; Short circuit current: 6.5 ma Impedance:.2 kω PNP-sensor Switch point: 2 V (Terminal 5) Max. input voltage: 3 V Impedance: 2.8 kω NPN-sensor Switch point: 2 V (Terminal 4) Impedance: 3.3 kω Triggerinput Switch point: 2 V (Terminal 2) Max. input voltage: 3 V Impedance: 2.8 kω Output relay Terminal : NO;Terminal : NC; Terminal 2: COM 25 V AC, 2 A, cosϕ.7 4 V DC, 2 A ON/OFF delay (incl. computation time) 2 ms Mechanical life 3.. switch cycles Switch state indicator 3 mm - yellow LED Timer functions ON/OFF delay, defined ON time, pulse lengthening Timer period: s... 999.9 s Direction of operation reversible Sensor power supply Terminal 3, 3: L+; Terminal, 7: L- 24 V DC ± %, U ss %, 3 ma short circuit protected Start-up bypass Triggered by external signal (Terminal 2) or by switching on the supply voltage (Terminal 2 and Terminal 3 bridged) Bypass time:. s... 999.9 s Error of measurement. Hz... Hz:. % Hz... khz:.3 % khz... 5 khz:.5 % Display: ± digit Ready delay 4 ms Display rate of rotation and 4-digit 7-segment-LED-display, red, digit height: 7 mm frequency Design Modular terminal housing (Macrolon), system KF Mounting Snap-on to a 35 mm DIN rail per DIN EN 522 or to screw with extendable latches in a 9 mm grid Terminal connections Removable, encoded device terminals Cross sectional area: 2 x 2.5 mm 2 Operating temperature -25 C... +7 C Storage temperature -4 C... +85 C Pollution severity class 2 Protection class IP 2 EMV EN 58-2, EN 582-2 Overvoltage category II in accordance with EN 5 78

Terminal assignment 4 Terminal assignment Term. : Sensor power supply, GND Term. : Relay normally open contact, NO Term. 2: Trigger input for start-up bypass Term. : Relay normally close contact, NC Term. 3: Sensor power supply, 24 V DC Term. 2: Relay root, COM Term. 4: Power supply, 24 V DC Term. 3: Sensor power supply, 24 V DC Term. 5: Power supply, GND Term. 4: for NPN-sensor Input Term. 6: Not connected Term. 5: for PNP-sensor Input Term. 7: Sensor power supply, GND Term. 6: Power supply L, 23 V AC Term. 8: NAMUR input L - Term. 7: Power supply L, 5 VAC Term. 9: NAMUR input L Term. 8: Power supply N 5 Dimensions, operating and display devices 4 5 7 7 8 9 2 3 4 5 6 7 8 "Mode" and "+": Start parameterization editor "+": Advance to next parameter selection or increase the flashing digit by one "-": Return to previous parameter selection or decrease the flashing digit by one "Mode": Display parameter value (right character flashes) or shift the flashing character to the left "Enter": "Enter" and "+": Exit parameter value display, the device now works temporarily with the altered parameter. Exit parameter editor, the parameters are now permanently stored in the EEPROM. Date of issue 23-2-8 2

Connection plan 6 Connection plan Date of issue 23-2-8 Bridge fitted: start-up bypass triggered by switching on the power supply. External trigger signal Power supply 24 V DC 3 2 6 4 5 Sensor power supply 24 V DC Trigger input for start-up bypass Sensor power supply GND Not connected L+ L L (23 V~) N L (5 V~) COM NC NO NAMUR + NAMUR Sensor power supply 24 V DC Input for PNP Output circuit Input for NPN Output circuit Sensor power supply GND 9 8 3 5 4 7 L+ L+ TX 8 8 L- L- 3 L+ 3 L+ 7 L- 7 L- L+ L- L+ TX L+ TX 7 L- 7 L- or Power supply 23 V AC or Power supply 5V AC Relay output 6 8 7 2 yellow NAMUR Sensor NAMUR Rotary encoder 9 9 DC-3 wire sensor PNP DC-3 wire sensor NPN 5 4 DC-2 wire sensor DC-2 wire sensor 3 4 5 7 Rotary encoder, Push-pull output stage 3 5 Rotary encoder, Push-pull output stage 3 4 3

Function description overview 7 Function description overview Operating mode Password protection not activated. Password may not be edited. X=: frequency measurement. Hz...5 Hz X=: rotational speed measurement. r.p.m...9999 r.p.m. Preset at the factory: X= Number of pulses per revolution for rotational speed measurement (will be ignored for frequency measurement) XXXX 2 Preset at the factory: XXXX= Measuring and display range Frequency measurement: X 3 Rotational speed measurement: X 2 Preset at the factory: X= X Frequency range Rotational in Hz speed in rpm... 5... 9999..... 999.9.2.... 99.99.3.... 9.999 Lower hysteresis limit of switching point XXXX 9998 (depending on the measuring range) Preset at the factory: XXXX= Upper hysteresis limit of switching point. XXXX 9999 (depending on the measuring range) Preset at the factory: XXXX=2 Date of issue 23-2-8 4

Function description overview Period for the timer function of switching relay. s XXX.X 999.9 s Preset at the factory: XXX.X=. s Period for the timer function of switching relay Preset at the factory: X= X Function No timer function ON delay 2 OFF delay 3 Defined ON time 4 Pulse lengthening 5 No timer function, inverted 6 ON delay, inverted 7 OFF delay, inverted 8 Defined ON time, inverted 9 Pulse lengthening, inverted Start-up bypass. s XXX.X 999.9 s Preset at the factory: XXX.X=3. s Display rate. s XX.X 2.5 s Preset at the factory: XX.X=.33 s The number of the software version can be read only. Date of issue 23-2-8 5

Function description overview Date of issue 23-2-8 6

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the "Elektrotechnik und Elektroindustrie (ZVEI) e.v. in their most recent version as well as the supplementary clause: "Extended reservation of title". We at Pepperl+Fuchs recognise a duty to make a contribution to the future, For this reason, this printed matter is produced on paper bleached without the use of chlorine.

Signals for the world of automation www.pepperl-fuchs.com Worldwide Headquarters Pepperl+Fuchs GmbH Königsberger Allee 87 6837 Mannheim Germany Tel. +49 62 776- Fax +49 62 776- e-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. 6 Enterprise Parkway Twinsburg, Ohio 4487 Cleveland-USA Tel. + 33 4253555 Fax + 33 4 25 93 85 e-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. P+F Building 8 Ayer Rajah Crescent Singapore 39942 Tel. +65 677999 Fax +65 6873637 e-mail: sales@sg.pepperl-fuchs.com SIGNALS FOR THE WORLD OF AUTOMATION Subject to reasonable modifications due to technical advances Copyright Pepperl+Fuchs Printed in Germany Part. No. 2956 2/3 5