IECEx Certificate of Conformity

Similar documents
IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity


IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Refer to attachment for more details. Andreas Meyer

IECEx Certificate of Conformity


IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

I Ex-Installation switch I

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Page 1 of 5. Increased Safety, Encapsulation and Dust

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

SolConeX Wall-Mounted Socket, 16 A

IECEx Certificate of Conformity

SolConeX extra-low voltage flange socket

ECE Cert.fic te of Con ormity

M E M O R A N D U M I.S.

IECEx Certificate of Conform ity


IECEx Ce ificate of Conformi

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

IECEx Certificate of Conformity

IECEx Certificate of Conformity

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Operating Instructions

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

SolConeX plugs and sockets. our new global player

Physikalisch-Technische Bundesanstalt P1B

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Certificate of Conformity

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Certificate of Conformity Ex EQUIPMENT

IECEx OPERATIONAL DOCUMENT

Position Switches Series 8070

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Metal Position Switch

IECEx OPERATIONAL DOCUMENT

Safety instructions Overvoltage protection B81-35

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

FLEX Ex Spring Clamp Terminal Base

Micro Limit Switch Series 8064

Micro Motion, Inc. Page 1 of 6

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Operating instructions

Miniature Circuit-Breaker IEC Series 8562

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A

GRP Flameproof Visual Signal Xenon or Steady LED

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Installation & Operation Manual

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

mini CLIX: Explosion protected plug-in connector

Interface and Supply module. IPC 3x0i / PSC 3x0i

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Product manual plug, sockets and coupler 16 A.- Z0251

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Terminal Boxes Series 8118

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

PHOENIX CONTACT - 01/2008

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

INSTALLATION TECHNOLOGY MADE EASY

Power supply unit NG3-16ib

IECEx Certificate of Conformity Annexe

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Cable End Boxes Series 8146

Digital Input Output Module for Zone 1

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

PHOENIX CONTACT - 05/2007

Fieldbus Isolating Repeater

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

SMARTLINE RM76 Supplementary instructions

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Installation & Operation Manual

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history: Issue No. 2 (2010-8-9) Issue No. 1 (2006-1-31) Date of Issue: 2010-08-09 Page 1 of 4 Applicant: R. STAHL Schaltgeräte GmbH Am Bahnhof 30 74638 Waldenburg Electrical Apparatus: Optional accessory: Plug-and-socket-device, type 8571/..- Type of Protection: Flameproof enclosure d, Increased Safety e, Protection by enclosure td Marking: Ex de IIC T6 or T5 resp. Ex de [ia] IIC T6 or T5 Ex td A21 IP 66 T60 C or T75 C Tamb - 50 C to 55 C Approved for issue on behalf of the IECEx Certification Body: Position: Dr. Ing. Uwe Klausmeyer Head of Section "Flameproof Enclosures" Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: Physikalisch-Technische Bundesanstalt (PTB) Bundesallee 100 38116 Braunschweig

Page 2 of 4 Manufacturer: R. STAHL Schaltgeräte GmbH Am Bahnhof 30 74638 Waldenburg Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2004 Edition: 4.0 IEC 60079-1 : 2007-04 Edition: 6 IEC 60079-11 : 2006 Edition: 5 IEC 60079-7 : 2006-07 Edition: 4 IEC 61241-0 : 2004 Edition: 1 IEC 61241-1 : 2004 Edition: 1 Electrical apparatus for explosive gas atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Explosive atmospheres - Part 7: Equipment protection by increased safety "e" Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "td" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: DE/PTB/ExTR10.0044/00 Quality Assessment Report: DE/BVS/QAR10.0002/00

Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: See attachement. CONDITIONS OF CERTIFICATION: NO

Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Issue no. 1 contains alternative plastic materials. In addition the standards were adapted. Annexe: Issue2 IEC Ex Zertifikat.doc

Attachment to Certificate IECEx PTB 05.0024 issue No. 2 The plug-and-socket device, type 8571/..-..., with wall-mounting socket outlet, plug and flange-mounting socket outlet is to provide for cable connection in potentially explosive areas. If required, the auxiliary circuit may be equipped to form an intrinsically safe circuit. The integrated switch at the same time serves as an interlocking device to prevent actuation of the plug-and-socket device while alive. A staggered pin assignment, based on the thicker earth contact, makes sure that only identically coded plugs or socket outlets can be used together. The plug and the receptacle of this plug-and-socket device are designed for compatibility with the plug-and-socket device of type 8578/..-..-. Connection is by means of the integrated screw-type terminals. For proper mounting of the flange-mounting socket outlet, reference shall be made to the Notes for Manufacturing and Operation. Electrical data Types 8571/..-4.. and 8571/..-5.. Rated insulation voltage... up to Rated voltage... up to Rated current... max. Utilization category... Auxiliary contacts Rated insulation voltage... up to Rated voltage... up to Rated current... max. Utilization category... 750 V 690 V 32 A AC-3 550 V 500 V 6 A AC-12 / AC-15 Number of plug contacts... 4 to 5 Rated conductor cross section socket outlet... 10 mm² single wire plug... 6 mm² finely/extra finely... stranded aux. contacts... 2.5 mm² Ambient temperature...- 50 C to 55 C The composition of the protection symbol will be based on the types of protection of the components actually used. Physikalisch-Technische Bundesanstalt (PTB) Bundesallee 100, 38116 Braunschweig, Postfach 33 45, 38023 Braunschweig, Telephone +49 531 592-0, Telefax +49 531 592-3605 Page 1 of 1