SBOX-Max Operating Manual

Similar documents
OFFER VALID FROM R. 15 COLORS TEXT DISPLAYS SERIES RGB12-K SERIES RGB16-K SERIES RGB20-K SERIES RGB25-K SERIES RGB30-K

Myriad Pro Light. Lining proportional. Latin capitals. Alphabetic. Oldstyle tabular. Oldstyle proportional. Superscript ⁰ ¹ ² ³ ⁴ ⁵ ⁶ ⁷ ⁸ ⁹,.

Infusion Pump CODAN ARGUS 717 / 718 V - Release Notes. Firmware V

OFFER VALID FROM R. TEXT DISPLAYS SERIES A SERIES D SERIES K SERIES M

KbdKaz 500 layout tables

Gator Automatic Butt Fusion Range Operating Manual

Operating Manual version 1.2

TEX Gyre: The New Font Project. Marrakech, November 9th 11th, Bogusław Jackowski, Janusz M. Nowacki, Jerzy B. Ludwichowski

JOINT-STOCK COMPANY GIDROPRIVOD. RADIAL PISTON PUMPS OF VARIABLE DISPLACEMENT type 50 НРР

Operating Instructions

Portable Appliance Tester KT75 OPERATORS MANUAL

MIVOICE OFFICE 400 MITEL 6863 SIP / MITEL 6865 SIP

Designed to make your job easier MSA 2.0 and MSA 2.1 Electrofusion Units

Proweld Equipment Owner & Maintenance Manual Polymatic Electrofusion Machine

Configurations. User's guide

MIVOICE OFFICE 400 MITEL 6873 SIP USER GUIDE

99 Washington Street Melrose, MA Phone Toll Free Visit us at

uninsta un in sta 9 weights & italics 5 numeral variations Full Cyrillic alphabet

Calder Centaur Workshop Manual

Solar Installation PV100 Operating Instructions

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

HI-POT TESTER. User s Manual

OPERATING INSTRUCTION

MEGAFLASHROM SCC+ SD

Prestigio P371 Users manual

DIGITAL TORQUE ADAPTOR

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

4WCE * 5 * : GEO. Air Products and Chemicals, Inc., 2009

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Product Parts Front view... 2 Rear view... 2 Inside the product... 3 Scanner parts... 3 Control panel... 4

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Gobo Projector XP 80W

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

MICRON DJ Booth System with Overhead Kit & CW Starcloth

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

C.A 6165 Appliance multitester

MIVOICE OFFICE 400 MITEL 6867 SIP / MITEL 6869 SIP

Operating Instructions

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

LG-Nortel GDC-400 User manual

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

OMRON PROGRAMMABLE CONTROLLER. Input terminals TIMER ADJUSTMENT

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

HI-POT TESTER User Manual

M A C 3 Wind Speed Alarm & Controller

Crossfire. User Manual. Order code: EQLED061

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

USER S MANUAL Linear Programmable DC Power Supply APS

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Operating Instructions

Operating Instructions

Living. Keyfree Connected Smart Lock Manual. smart. The smarter way to protect your home

QUICK START USER GUIDE. Data Logger Model L452

Operating Instructions. Technical Equipment FRIAMAT. Fusion Units

1.Installation 2.Channel 3. Setting 4.Service 5.Information

Spectralink 7202/7212 Handset. User Guide IG, Edition 12.0 January 2018, Original document

Spectralink 7722/7742 Handset. User Guide IG, Edition 11.0 April 2018, Original document

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

DMX LED Starcloth Systems

IMPACT Order code: EQLED79

RGB Power Batten. User Manual. Order code: EQLED032

Micro-Ohmmeter Model 6292

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

UV Spectra Batten 12 x 5W UV LEDs

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

PX Series Balances. Quick Start Guide. Please download the user manual from

Installation & Calibration Manual

«, 68, 55, 23. (, -, ).,,.,,. (workcamps).,. :.. 2

Slimline CW & WW Series

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Economy Single Channel Output DC Power Supply

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

DS3 / DS31 User Manual

Model HM-535 Power Supply Installation and Service Instructions

O P E R A T O R S M A N U A L

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

installation quick guide integrated access control & environmental monitoring

DIGITAL GEAR PUMP DRIVE OPERATING MANUAL: Model No.

Installation & Calibration Manual

DC100 Digital Dispenser Operating Manual

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

121000TP227S USER'S MANUAL

Intrinsically safe batch controller Batching Master 110i

MAC3 Wind Speed Alarm & Controller. Installation Instructions

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Autoranging True RMS Multimeter User Manual

MICRON DJ Booth Tri-colour Starcloth

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

Digital Photo Frame With Alarm Clock Model DPF-363

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

w w w. p r o l i g h t. c o. u k STAGE PAR 64

DLRO 200 High Current, Low Resistance Ohmmeter

CF3000 Dealer Diagnostic Tool Instruction Manual

Blitzer Strobe. User Manual. Order code: EQLED366

USER MANUAL. For XLCD17-LED XLCD19-LED

ServView 17S KVM Switch

Transcription:

SBOX-Max www.fusiongroup.com

Contents 1 Safety instructions 1 1.1 Precautions when lifting 1 1.2 Risk of fire or explosion 1 1.3 Risk of electrical shock 1 1.4 Risk of burns 1 1.5 Operating 1 1.6 Re-fusing fittings 1 2 Getting to know your SBOX-Max 2 3 Quick instructions on fusing a joint 3 4 Scope of operation 4 5 Maintenance 4 5.1 User maintenance 4 5.2 Servicing 4 6 Manual data entry 5 6.1 Data entry 5 7 Status bar 6 7.1 Standard status bar 6 7.2 Backing up record to memory card 6 7.3 Sending data to USB memory device 6 8 General operation 7 8.1 Power-up sequence 7 8.2 BlueBox 7 8.3 Warning messages 7 8.3.1 Jointing cycle power interruption 7 8.3.2 Joint lockout 8 8.3.3 Service alarm 8 8.3.4 Overheating 9 8.3.5 Entry of traceability data 9 9 Information entry 9 9.1 Messages on information entry screen 10 10 Fitting information screen 11 10.1 Modes of operation 11 10.2 Fitting connection 11 10.3 Fusion time selection or identification 12 10.4 FUSAMATIC: Automatic mode 12 10.4.1 Auto fittings only 12 10.5 Manual 13 10.5.1 Edit target voltage 13 10.5.2 Edit target time 14 10.6 Barcode mode (Barcode box only) 14 10.6.1 Information shown on the barcode screen 15 10.7 Starting the heating cycle 16 10.8 Heating cycle 16 10.9 Manually aborting the cycle 16 10.10 Cycle completion - Cool time 16 10.11 Cycle completion - With cooling cycle (Barcode boxes only) 17 11 Memory full or nearly full 17 12 Error messages 19 13 User menus 20 13.1 Adjust LCD contrast (Menu option 00) 20 13.2 Set language (Menu option 01) 20 13.3 Output joint record(s) (Menu option 02) and JointManager (Menu option 03) 21 13.3.1 Send to 21 13.3.2 Screen 21 13.3.3 USB drive 21 13.3.4 Select record(s) view/download 21 13.3.4.1 Last joint 21 13.3.4.2 All joints 21 EDOI8954 Issue 01

13.3.4.3 Joint range 21 13.3.4.4 All complete 21 13.3.4.5 All incomplete 22 13.3.4.6 Matching criteria 22 13.3.4.7 Sending data view/download 22 13.4 System variables (Menu option 04) 23 13.5 Remove user history (Menu option 05) 23 13.6 Recover archived records (Menu option 06) 23 13.7 Daylight saving (Menu option 07) 23 14 User diagnostics menu 24 14.1 Test / Calibration (01) 24 14.1.1 Measure coil resistance (04) 24 14.1.2 Measure ID resistance (06) 24 14.1.3 Keypad and buzzer test (10) 24 14.1.4 Test scanner (11) 24 15 Specification 25 16 Rights 26 17 Accessories 26 Appendix A SBOX-Max Manual entry character set 27 A.1 Number character set. 27 A.2 ABC font set 27 A.2.1 Upper case characters 27 A.2.2 Lower case characters 27 A.3 Russian 28 A.3.1 Upper case characters 28 A.3.2 Lower case characters 28 A.4 Japanese 28 A.4.1 Upper case characters 28 A.4.2 Lower case characters 28 A.5 Symbol 28 EDOI8954 Issue 01

1 Safety instructions These operating instructions must be followed to ensure the safe operation of the SBOX-Max Electrofusion Control Unit and operators must be fully conversant with the safety instructions. Fusion Group Limited can offer operator training and regular maintenance where required. Only use undamaged equipment that has been properly maintained and calibrated. Refer to section 5 Maintenance of this operating manual for further information. 1.1 Precautions when lifting Where necessary, operators are advised to request for assistance when carrying, moving or lifting this equipment. 1.2 Risk of fire or explosion Do not use this equipment in combustible gaseous environments. 1.3 Risk of electrical shock This equipment delivers up to 48V AC via the output lead. The unit output power must not be energised without proper connection of the correct load (fitting) types. Avoid walking or standing on cables and ensure that the cables are safely routed. This equipment must be connected to a suitable electrical earth supply. Recommendation: For additional safety it is recommended that the unit be connected to a power supply incorporating suitable protection (such as a 30mA RCD). 1.4 Risk of burns The process of Electrofusion jointing generates heat in the fitting and pipe. The use of heat resistant gloves is strongly recommended, as is use of suitable eye protection. 1.5 Operating Only trained and authorised operators must operate this equipment, keep any unauthorised personnel away from the equipment. Children must not operate this equipment. 1.6 Re-fusing fittings The fusion operation must not be repeated on the same fitting since this can result in live parts becoming exposed on the fitting. EDOI8954 Page 1 Issue 01

2 Getting to know your SBOX-Max The SBOX-Max is shown in detail in the illustrations below. Display Scroll up button Scroll right button USB A type connector Mains Input switch Stop or exit button LED s for BlueBox Scroll left button Scroll down button Start or enter button Output lead Scanner Ambient temperature sensor EDOI8954 Page 2 Issue 01

3 Quick instructions on fusing a joint 1. Connect the control unit to the mains supply and switch the mains input switch that is located on the side of the control unit to the ON position. 2. On power up the company logo, property of, date and time will be shown for 5 seconds. 3. Connect output lead to fitting (if Fusamatic red lead to red pin). 4. Press the green button to confirm that the pipe has been scraped and clamped. 5. Then press the green button to proceed. 6. To start welding for: a. Fusamatic Check and confirm weld time. b. Manual Enter manual weld voltage and time which can be accessed using the green button. c. Bar code box only Scan the bar code, check and confirm weld information. 7. Press green button to start the fusion cycle. 8. Barcode only if enabled, the cool time countdown timer will start when the fitting has finished fusing. Do not stop cool time or disconnect the leads from the fitting during this period. 9. After disconnecting the fitting the information screen will be displayed again. EDOI8954 Page 3 Issue 01

4 Scope of operation This unit is designed solely for the use of jointing of polyethylene (PE) Electrofusion fittings. 5 Maintenance 5.1 User maintenance Prior to connecting the unit to a supply or fitting always: Ensure that the lead ends are clean and free of damage. If the lead ends are not clean incorrect Fusamatic times may be recognised. Visually inspect the control unit enclosure for any damage. Ensure that the mains input plug is not damaged and remove any dirt. Check there is no damage to the input and output cable such as torn insulation or deep gouges. Ensure that the Barcode Reader is connected (Do not connect after the supply is turned on as the box or the scanner could be damaged). Ensure that the unit has been appropriately maintained and calibrated. Never use the control unit if plug, leads or enclosure are damaged, the service agent or Fusion Group Limited must carry out maintenance and service. Do not attempt to open the enclosure - there are no user serviceable parts inside. Note: The lead ends can be replaced using the following procedure. 1. Make sure the unit is disconnected from the power supply. 2. Unscrew the lead end connectors (anti clockwise). 3. Pull out the sense pin on the red lead end only. 4. Replace the sense pin on the red lead end only. 5. Replace the terminal connector ensuring it is fully tightened. 5.2 Servicing To ensure safe operation and optimum performance is maintained, either the manufacturer or an authorised service agent should check and calibrate this product at intervals of no longer than 12 months. For technical information contact the nearest service agent or the manufacturer, Fusion Group Limited via telephone on +44 (0) 1246 268666. EDOI8954 Page 4 Issue 01

6 Manual data entry Manual data entry is required at various points in the operation of the unit. 6.1 Data entry There are two modes for character entry - Select mode and Edit mode. On activating Manual Data Entry the box is in Select mode. Select mode Characters/Actions are selected using the up, down, left and right buttons to move the Select cursor to the required icon. The selected character/action is accepted by pressing the green button. Edit mode To select Edit mode move the Select cursor to and press the green button, the Select cursor goes off (indicating Edit mode). The Edit cursor can then be moved within the edit string by using the left and right buttons. To insert a character, exit Edit mode (by pressing the green button, the Select cursor will re-appear over the icon) and select the required character as normal. Edit Cursor - If the Edit cursor cannot be seen the edit position is to the right of the last character in the entry field. Select Cursor If the Select cursor cannot be seen the box is in Edit Mode. Insert Characters - Characters will always be inserted to the left of the Edit cursor until the entry field is full. The Edit cursor will move to the right as characters are inserted. Delete Characters - Characters to the left of the Edit cursor can be deleted at any time by pressing the red button. The Edit cursor will move to the left as each character is deleted (until the Edit cursor is at the left most position). Extended Character - On certain fonts and characters, if the green button is held down for at least three seconds, the extended characters will be shown. Once the extended character pop-up is displayed, selection is carried out as described in Select Mode. NOTE: if the pop-up has been displayed and the extended character is not required, pressing the red button will exit the pop-up without adding the extended character. See appendix A. Restricted Entry Fields If the entry field requires specific characters, selection is restricted to those characters. Edit Operator --------------------------------------- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - - Accept text and exit (Action) - Delete the text string (Action) - Select Edit Mode (Action) - Change font being used (Action) - Switch between upper and lower case characters. (Action) - Space character. EDOI8954 Page 5 Issue 01

7 Status bar The status bar is shown at the bottom of most of the screens showing information on the service period and input supply. Each bar on the memory status indicates approximately 80 joint records. The spanner between the number of joints and the days to next service will flash, when either the number of joints or the days to next service are less than 21. 7.1 Standard status bar This status bar is shown when in information entry, fitting information and fusing screens. 1000 182 10:10 10:05:14 230 50 SBOX Memory status Number of joints to next service Number of days to next service Time Date Input voltage Input frequency 7.2 Backing up record to memory card This status bar is shown when backing up to memory card when joint is complete. 1000 182 SD Memory status Number of joints to next service Number of days to next service Back up to memory card status 7.3 Sending data to USB memory device This status bar is shown when sending data to USB memory device (in review joint record(s), print joint record(s) and fast data transfer modes). 1000 182 Memory status Number of joints to next service Number of days to next service Download to USB status EDOI8954 Page 6 Issue 01

8 General operation 8.1 Power-up sequence Ensure that the input and output cables are fully rolled out. Barcode units only make sure to connect the Barcode Reader to the scanner lead before powering up the control unit. Connect the control unit to a suitable power supply (mains or generator). Put the mains input switch to the ON position it is located on the side of the unit the switch will illuminate when switched ON. The LCD (Liquid Crystal Display) indicates the following for approximately 5 seconds and on the barcode unit only a short audible tone will sound. Fusion Group 12:35:10 03/05/14 If ISO12176-3 login method have been enabled the box will be inoperable until a valid operator barcode is scanned. The screen will either promt for a valid operator barcode, when a valid operator barcode is scanned to the box before the information entry screen will be displayed. If the red button is pressed the user menu will be displayed see section 13 user menu. 8.2 BlueBox If BlueBox has been enabled then a mobile device must be connected to the SBOX-Max via bluetooth with the BlueBox application open, before the information entry sceen is displayed. Refer to mobile device operating instruction for connecting via bluetooth. For further details contact Control Point on +44 (0)1246 262422 or email info@controlpointllp.com. 8.3 Warning messages At power up certain warning messages may be displayed. These are: 8.3.1 Jointing cycle power interruption Power fail detected! E08: Power fail heat phase to proceed If the jointing cycle or cool cycle has had a power interruption the above message will be shown. The message will be repeatedly displayed at power up until the green button has been pressed. EDOI8954 Page 7 Issue 01

8.3.2 Joint lockout If Joint Lockout has been enabled, the operator will be instructed to contact a supervisor whenever an incomplete joint is made. If the joint was incomplete a message prompting the operator to call the supervisor is displayed. Along with this prompt, a code letter between A and Z is displayed, along with the failed joint number. The operator is requested to quote the letter and joint number to the supervisor. The supervisor then issues a response code to the operator, who then enters this unlock code. If the code is entered incorrectly a new code letter is generated and the operator has to request a new response code. If the code is entered correctly the joint is then unlocked and the box can progress to the next joint. Turning the box off does not bypass the Joint Lock Out test, so the operator cannot proceed without obtaining and entering a valid response code. If the joint is classed as complete the box will progress to the next joint. If Joint Lockout is disabled the software will ignore the status of the joint. 8.3.3 Service alarm This indicates that either, the number of joints made or the number of days since the last service has been exceeded. The unit is in need of a service and contact should be made with nearest service centre. If Service Lockout has been disabled - press the green button to carry on using the box. Service required will be recorded on the joint data until the box is serviced and the service period been reset.! Service Required! Contact Fusion Group +44 (0)1246 268666 +44 (0)1246 268052 Press to continue If Service Lockout has been enabled - the SBOX-Max is inoperable until it has been serviced and the service period has been reset.! Service Lock Out!! Service Required! Contact Fusion Group +44 (0)1246 268666 +44 (0)1246 268052! Service Lock Out! EDOI8954 Page 8 Issue 01

8.3.4 Overheating SBOX-Max Electrofusion Control Unit!Warning! Internal Temperature too high Wait for SBOX to Cool Temperature Int ( ) 67.1 This indicates that the temperature inside the box has risen above +65 C. The box will remain inoperable until the internal temperature has dropped below +55 C. Refer to onscreen temperature gauge as shown above. 8.3.5 Entry of traceability data Traceability parameters such as operator code or location code, can be entered by barcode reader (if a suitable barcode exists), manually, or bypassed if not required. Traceability barcode styles should be Code128 or ITF 2 of 5. Barcode box only: At the appropriate parameter entry display, to enter a parameter using the barcode reader, locate the appropriate barcode and read it using the reader. 9 Information entry The unit will prompt for entry of operator, location, optional data 1, optional data 2 and project - if enabled - as follows:! Connect Fitting <Operator> <Location> <Optional Data 1> <Optional Data 2> <Project> Pipe Scraped & clamped? Continue Press To confirm Scroll onto the field required by using the up and down buttons on the keypad. When the appropriate field is highlighted, either press the left or right buttons to select one of the last five entries for the particular field or press the green button to enter the edit screen. On pressing the green button the following screen will be displayed. Edit Operator --------------------------------------- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - EDOI8954 Page 9 Issue 01

Scroll to the appropriate character using the up, down, left and right buttons on the keypad. Then press the green button on the keypad to select the character. Repeat this until the required information is entered. Then select press the green button on the keypad to return to information entry screen. For more information see section 6.1 character entry screen. After entering project the edit project joint number screen will be displayed. If a previous project has been selected then the next project joint number will be displayed on edit project joint number screen. The project joint number can be made up of letters and numbers. The box will increment the number but not the letters. Any letters AFTER the number will be lost for the following joint. Barcode box only: If ISO12176-3 operator login method entry is enabled and a valid operator barcode has been scanned then the operator information will be displayed. Note: that the operator, location, optional data 1, optional data 2, project and project joint number information is retained for subsequent joints. If any of operator, location, optional data 1, optional data 2 and project are not required then leave them empty or enter a space character. Up to 5 previously entered items of data are maintained for re-use. This History data can be accessed by pressing the left or right scroll buttons. After entering the required information scroll to Pipe scraped and clamped?. Scrape and then clamp the pipe(s) in accordance with governing authority procedures. Confirm this has been done by pressing the green button will be displayed against the prompt. Connect the fitting - when the fitting is connected, the top of the information screen will display Fitting Connected. The box will only continue when Pipe scraped and clamped? has been confirmed and the fitting is connected. When this has been done the cursor will scroll down to Continue. Press the green button to proceed to the fitting information screen. 9.1 Messages on information entry screen Connect fitting: Fitting not connected or a faulty fitting. Fitting Connected: Waiting to proceed to fitting information screen. Connect Lead: Faulty output lead contact service agent. EDOI8954 Page 10 Issue 01

10 Fitting information screen The unit will now prompt for entry of Component 1 batch, Component 2 batch, Optional batch and Fitting batch if enabled as follows: Fitting Details <Component 1 Batch> <Component 2 Batch> <Optional Batch> <Fitting Batch> Scroll onto the field required by using the up and down buttons on the keypad when the appropriate field is highlighted press the green button on the keypad. The following screen will be displayed. Edit Component 1 batch --------------------------------------- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - Scroll to the appropriate character using the up, down, left and right buttons on the keypad. Then press the green button on the keypad to select the character. Repeat this until the required information is entered. Then select press the green button on the keypad to return to fitting information screen. For more information see section 6.1 character entry screen. Barcode box only scan the barcode by scrolling to the appropriate field then using the barcode reader to scan the information. If ISO12176-4 tractability entry is enabled, a valid fitting batch and at least one component batch barcode has been scanned before the fitting barcode can be scanned. If the fitting is disconnected while on this screen the box will return back to the information entry screen. 10.1 Modes of operation The unit can operate in three distinct operating modes: Manual mode Fusamatic mode Barcode mode 10.2 Fitting connection In the case of Fusamatic mode, the red lead end should be connected to the red identification pin of an automatic fitting and the black lead end to the plain fitting pin. If SBOX-Max is connected to a non Fusamatic fitting or connected to a Fusamatic fitting in reverse, this will force manual or barcode mode operation. EDOI8954 Page 11 Issue 01

10.3 Fusion time selection or identification The SBOX-Max incorporates three modes of entering the fusion time for electrofusion jointing. The first mode is automatic using the Fusamatic system of fitting recognition with Fusamatic fittings. The second is manual mode, which enables manual entry of output voltage level and jointing cycle time. The third is barcode mode, which enables setting of fusion parameters (such as output voltage and fusion time/energy) by reading a fitting barcode that can usually be located on the side of the electrofusion fitting. 10.4 FUSAMATIC: Automatic mode In automatic mode, the SBOX-Max control unit interrogates the fitting and if it is a correctly connected Fusamatic type, establishes the fusion cycle time. Note: this requires the red lead end to be connected to the fitting pin with a red identifier and the black lead end connected to the plain fitting pin. From the information screen press the green button to confirm that the pipes are scraped and clamped. Then press the green button to proceed. When the automatic fitting has been identified, the display indicates the time and voltage see example below. Fusamatic Fitting <Component 1 Batch> <Component 2 Batch> <Optional Data> <Fitting Batch> Volts (V) 39.5 Time (s) 750 FUSE Press to confirm Check that the correct fusion time and voltage have been detected by verifying the information indicated on the fitting. Press the green button to fuse. If an incorrect fusion time is displayed, disconnect the fitting and then reconnect to try once more. If the time indicated on the display is still not correct. Manual mode can be forced by reversing the output lead connections. 10.4.1 Auto fittings only If the auto fitting option has been enabled the box will only recognise Fusamatic fittings and not recognise manual fittings. From the information screen press the green button to confirm that the pipes are scraped and clamped. Then press the green button to proceed. When the automatic fitting has been identified, the display indicates the time and voltage see example below. EDOI8954 Page 12 Issue 01

Fusamatic Fitting <Component 1 Batch> <Component 2 Batch> <Optional Data> <Fitting Batch> Volts (V) 39.5 Time (s) 750 FUSE Press to confirm Check that the correct fusion time and voltage have been detected by verifying the information indicated on the fitting. Press the green button to fuse. If an incorrect fusion time is displayed, disconnect the fitting and then reconnect to try once more. If a non Fusamatic fitting has been fitted and recognised then the following will be displayed.!warning!!manual Fitting Detected! Auto-Fitting Only Selected Replace Fitting 10.5 Manual If the fitting is not a Fusamatic type, or a Fusamatic fitting is connected in reverse (black lead end to the red sense pin of the fitting). Fitting Details <Component 1 Batch> <Component 2 Batch> <Optional Batch> <Fitting Batch> <Manual> From the information screen press the green button to confirm that the pipes are scraped and clamped. Then press the green button to proceed. The Fitting information screen will be displayed as above. Scroll onto <Manual> using the up and down buttons on the keypad then press the green button. 10.5.1 Edit target voltage The edit target voltage screen will be displayed. Edit Target Fusion voltage ---- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - Scroll to the appropriate character using the up, down, left and right buttons on the keypad. Then press the green button on the keypad to select the character. For more information see section 6.1 character entry screen. Once the target voltage is entered the edit target time screen will be displayed. EDOI8954 Page 13 Issue 01

10.5.2 Edit target time The edit target time will be displayed on barcode and non-barcode boxes. Edit Target Fusion time ---- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - Scroll to the appropriate character using the up, down, left and right buttons on the keypad. Then press the green button on the keypad to select the character. For more information see section 6.1 character entry screen. After the voltage and time have been entered the following screen will be displayed. Manual Fitting <Component 1 Batch> <Component 2 Batch> <Optional Data> <Fitting Batch> Volts (V) 39.5 Time (s) 60 FUSE Press to confirm Check that the voltage and time are correct for the fitting used. If not the voltage and time can be edited by scrolling to the item that needs editing and pressing the green button to edit the information. If voltage and time are correct press the green button to start the fusing cycle. 10.6 Barcode mode (Barcode box only) If the fitting is not a Fusamatic type, or a Fusamatic fitting is connected in reverse (black lead end to the red sense pin of the fitting). Fitting Details <Component 1 Batch> <Component 2 Batch> <Optional Data> <Fitting Batch> <Manual> <Fitting Barcode> EDOI8954 Page 14 Issue 01

From the information screen press the green button to confirm that the pipes are scraped and clamped. Then press the green button to proceed. The Fitting information screen will displayed as above. Scroll onto <Fitting barcode> using the up and down buttons on the keypad. Then using the barcode scanner scan the barcode on the fitting or press the green button to enter the fitting barcode manually the following screen will be displayed. Edit Fitting Barcode --------------------------------------- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - Scroll to the appropriate character using the up, down, left and right buttons on the keypad. Then press the green button on the keypad to select the character. For more information see section 6.1 character entry screen. If the reader was used to scan the fitting barcode, a display similar to the example shown below will be presented: FUSI Coupler 63mm Coil Resistance (Ω)0.91 Measured Resistance (Ω)0.93 Volts (v) 40.0 Time (s) 35 Cool Time (s) 600 Press to continue 10.6.1 Information shown on the barcode screen Note: the display indicates the following information: Item Detail Example Manufacturer Fusion Group Limited FUSI Fitting type Coupler Coupler Fitting size 63mm 63mm Coil resistance Theoretical resistance 0.91 Ohms Measured resistance Actual measured resistance 0.93 Ohms Volts Target voltage 40.0 Time Target time 35 seconds Cool Time Target cool time 600 seconds EDOI8954 Page 15 Issue 01

Check fitting details are correct then press the green button to continue. The fitting information screen is then displayed as shown below. Barcode Details <Component 1 Batch> <Component 2 Batch> <Optional Data> <Fitting Batch> Volts (V) 40.0 Time (s) 35 FUSE Press to confirm Check that the information is correct if correct press the green button to start the fusing cycle. 10.7 Starting the heating cycle The fusion (heating) cycle can start as soon as a valid time and voltage has been set-up (using Fusamatic, Manual or Barcodes). Press the green button on the key pad to start fusing cycle. If Blue Box has been enabled the display will prompt for a photograph to be taken by the connected mobile device before the fusion cycle can be started. 10.8 Heating cycle The output power will be energised and the display will indicate the fusion cycle time remaining, output voltage, output current for the present joint number see example below. Await completion of cycle. Heating Cycle Joint number 20 Time remaining (s) 76 Output voltage (V) 39.5 Output current (A)16.4 Observe cool time (s) ------ 10.9 Manually aborting the cycle Note: that the cycle can be aborted by pressing the red button on the keypad or disconnecting the main power. Also, disconnection of the fitting from the output cable will abort the process. Any manual aborting of the heating cycle will result in an error message being shown on the screen. WARNING: Disconnecting the input power or fitting is not recommended. 10.10 Cycle completion - Cool time When the heating cycle has been successfully completed, the display will show the following if there is no specified cooling time or it has been disabled. Disconnect the fitting as prompted the screen will then return to the information entry screen, but, EDOI8954 Page 16 Issue 01

DO NOT REMOVE THE CLAMPS UNTIL THE COOLTIME HAS ELAPSED! Joint status Joint number 20 Joint complete Disconnect Fitting Observe cool time! 10.11 Cycle completion - With cooling cycle (Barcode boxes only) When the heating cycle has successfully reached completion, the display will indicate the following if there is a specified cooling time. Cooling Cycle Joint number 20 Time remaining (s) 0 Output voltage (V) ------ Output current (A) ------ Cool time (s) 273 WAIT FOR COOLING CYCLE COMPLETION BEFORE DISCONNECTING THE FITTING OR REMOVING THE CLAMPS! When cool time complete the screen will then display: Joint status Joint number 20 Joint complete Disconnect Fitting Disconnect the fitting as prompted and remove clamps. The process will then return to information entry screen. 11 Memory full or nearly full When the memory remaining falls and remains below 200 joints, the below screen is shown. The Joints Remaining counts down after each successive joint is made. The operator can make more joints by pressing the green button to Proceed. Joint Remaining 199! Box will be inoperative When database is full Retrieve and Erase data As soon as possible to Proceed EDOI8954 Page 17 Issue 01

When Joints Remaining reaches 0 (no more memory available) the memory is full. The box will be prevented from making any more joints until the joint data has been downloaded and the memory has been erased. Joints Remaining 0! INTERNAL DATABASE FULL For the box to operate Retrieve and Erase data to access User Menu On pressing the red button the User Menu will be displayed and the data transfer/print out can be done. See section 13 User menu. After downloading/printing the joint records the User Menu will re-appear. On pressing the red button, the final screen will be displayed. Joints Remaining 0! INTERNAL DATABASE FULL To erase the database And activate box Contact Engineer The database must now be erased to allow more joints to be made. Contact the nearest service centre. EDOI8954 Page 18 Issue 01

12 Error messages During the heating ( fusion ) cycle, the controller monitors the system for problems that could result in potentially poor joints. In the event of such a problem, a message is issued indicating its nature. The following shows the failure modes, likely causes and remedies. Mode Message Reason Possible cause Remedy E01 High output voltage Measured output voltage higher than 1.5% Surge in supply Check supply and adjust if necessary E02 Low output voltage Measured output voltage lower than 1.5% E03 Excessive output voltage Measured output voltage higher than 6.5% E04 High output current Measured current higher than 10% above previous sample E05 Low output current Measured current lower than 1.0A E06 Excessive output current Measured current higher than 20% above initial current measurement E07 pressed heat Operator pressed the stop switch to manually abort the cycle E08 Power Fail-Heat Phase A power failure was detected during the cycle E09 E10 E11 pressed during COOL Disconnected during cool The stop switch was pressed during the cooling phase The fitting was disconnected during the cooling phase Power Fail - Cool Phase A power failure was detected during the cycle Calibration error Input voltage too low Calibration error Surge in supply Calibration error Shorted turns in fitting due to poor preparation Disconnected fitting High fitting resistance Open circuit fitting Excessive shorted turns in fitting Operator intervention Power disconnected Generator out of fuel stop key manually operated Fitting disconnected Power disconnected Generator out of fuel If any other error messages appear on the screen, contact Fusion Group Limited via telephone on +44 (0) 1246 268666. Contact supplier Check supply and adjust if necessary Contact supplier Check supply and adjust if necessary Contact supplier Cut out and replace fitting Only disconnect fitting in emergency Try another fitting Cut out and replace fitting Cut out and replace fitting Only press the stop switch in an emergency Only disconnect power in an emergency Refuel generator Only press the stop switch in an emergency Only disconnect fitting in an emergency Only disconnect power in an emergency Refuel generator EDOI8954 Page 19 Issue 01

13 User menus The User Menu allows the user to view and download joint data and System Variables, change contrast and erase the history data. To enter the User Menu, press the red button when in the information entry screen. Use the up and down buttons to highlight the required menu option then press the green button to select. 13.1 Adjust LCD contrast (Menu option 00) Selecting this option will allow the LCD contrast to be adjusted from the keypad. Pressing the up and down buttons on the keypad will adjust the LCD contrast in small steps. Pressing the left and right buttons on the key pad will adjust the LCD contrast in bigger steps. To confirm the LCD contrast and exit press the green button. Press the red button to exit without changing the contrast. Adjust LCD contrast = - = + = = 13.2 Set language (Menu option 01) If enabled for user menu selecting this option will allow the User to set the operating language of the SBOX-Max. Using the up and down button on the keypad select the required language. To confirm the language selected and exit, press the green button. Press the red button to exit without setting the language. Select Language 001 English 002 Français 003 Español 004 Deutsch 005 Italiano 006 Portugues 010 Svenska Scroll, Select, = Exit If not enabled for user menu selecting the following screen will be displayed if set language is selected.! Warning! Not enabled Press to continue EDOI8954 Page 20 Issue 01

13.3 Output joint record(s) (Menu option 02) and JointManager (Menu option 03) Selecting these options allows the operator to view joint data on the screen or download joint data to memory stick. View downloaded joint data in Microsoft Notepad from output joint records option or view joint data in JointManager from JointManager option. Send to: Review joint(s) Screen Select record(s): Last joint From 24 To 24 to Proceed 13.3.1 Send to First use the up and down buttons to select Send to then using the left and right buttons to select the destination for the joint data. 13.3.2 Screen Display the joint data on the screen. See section 13.3.4 select record(s) view/download. 13.3.3 USB drive Downloads the joint data to memory stick so the data can be viewed in Notepad (Unicode Font must be used) or JointManager depending on option selected. Connect the memory stick to the USB A connector on the front of the box. See section 13.3.4 select record(s) view/download. 13.3.4 Select record(s) view/download Using up and down buttons scroll to Last joint. Using the left and right buttons select the required joint selection choosing from. 13.3.4.1 Last joint This gives the last joint fused. See section 13.3.4.7 sending data view/download. 13.3.4.2 All joints This gives all the joints in the database. See section 13.3.4.7 sending data view/download. 13.3.4.3 Joint range Allows a range of joints to be selected by scrolling down to From or To then using the left and right buttons on the keypad to select the joint range. See section 13.3.4.7 sending data view/download. 13.3.4.4 All complete This gives all the complete joints in the database. See section 13.3.4.7 sending data view/download. EDOI8954 Page 21 Issue 01

13.3.4.5 All incomplete This gives all the incomplete joints in the database. See section 13.3.4.7 sending data view/download. 13.3.4.6 Matching criteria This gives joint data for an operator and/or project by scroll to operator or project press green button to enter criteria the following screen will be displayed. Operator --------------------------------------- A B C D E F 1 2 3 G H I J K L 4 5 6 M N O P Q R 7 8 9 S T U V W X, 0. Y Z + - Scroll to the appropriate character using the up, down, left and right buttons on the keypad. Then press the green button on the keypad to select the character. For more information see section 6.1 character entry screen. If no match is found the following screen is displayed: Operation cancelled: No matching record Press to continue See section 13.3.4.7 sending data view/download. 13.3.4.7 Sending data view/download When the required joint selection has been made scroll down to to proceed then the relevant information will be given. If the destination is the screen one joint at a time will be displayed. Use the up and down buttons on the keypad to scroll up and down the joint data. Press the green button to tab across to see the information that runs off the side of the screen. Use the left and right button to move on to the next joint. Press the red button on the keypad to exit. When joint data has been sent to USB drive the screen will display complete press to continue. The status bar at the bottom of the screen will show the status of the download see section 7 status bar. If the database is empty the following screen is displayed. Review Joint(s) No records! to Proceed EDOI8954 Page 22 Issue 01

13.4 System variables (Menu option 04) Selecting this option allows the operator to view the current system settings, e.g. serial number, property off, software version, joint number and the set options, on the screen or download current system settings to memory stick to view joint data in Microsoft Notepad. Use the up and down buttons on the keypad to scroll up and down the system variables. Press the green button to tab across to see the information runs off the side of the screen. Press the red button on the keypad to exit system variables. This information may be asked for when contacting Fusion Group. View On Screen Send to: Screen System Variables to Proceed Refer to section 13.3.1 for how to select other Send to: destinations for the System Variables data. The first screen of information is shown below. System Variables Serial No.: SBOX30002 Plant Number: - Property Of: FUSION GROUP Software: 1.2 Voltage: 230v Joint No. information: Total 35 Scroll Exit Tab 13.5 Remove user history (Menu option 05) Selecting this option will allow all the user history to be erased. Press the green button to proceed and erase the user history. Press any other button to exit the Remove user history menu option. 13.6 Recover archived records (Menu option 06) Selecting this option will allow the user to recover records previously archived to the SD card. Press the green button to access the archived files, then use the up, down and green button to select the archive file to be recovered. When the green button is pressed the SBOX-Max will prompt the user to connect a memory stick, it will then proceed to transfer the selected data to the memory stick. Pressing the red button will cancel to procedure. 13.7 Daylight saving (Menu option 07) Selecting this option will allow the user to toggle the daylight saving. Press the green button to access the daylight saving option, then press the green button to add or remove an hour from the time. Press the red button to exit daylight saving. EDOI8954 Page 23 Issue 01

14 User diagnostics menu To enter the user diagnostic menu turn on the unit, when the logo screen is displayed press the red button then press the red button again. 14.1 Test / Calibration (01) The options in test / Calibration allow the operator to test relevant parts of the SBOX-Max. Press the green button to enter the test / calibration menu option then use the up and down buttons to select the relevant menu option then press green button to enter the menu option. 14.1.1 Measure coil resistance (04) The measure coil resistance option allows the fitting coil resistance to be checked via the screen display. Connect the lead ends to a fitting the coil resistance is displayed. Press the red button on the keypad to exit the measure coil resistance menu option and return to the test / calibration menu. 14.1.2 Measure ID resistance (06) The measure ID resistance option allows the Fusamatic time and resistance calibration to be checked via the screen display. Connect the lead ends to a Fusamatic fitting. Check that the correct fitting time is shown and there will also be a resistance displayed on the screen. Press the red button on the keypad to exit the measure ID resistance menu option and return to the test / calibration menu. 14.1.3 Keypad and buzzer test (10) The keypad and buzzer test option allows the keypad and buzzer to be tested. Press each button in turn; the respective button will be highlighted on the screen. If the green button is pressed the buzzer will also sound. Pressing the red button will result in the screen returning to the test / calibration menu after a brief period. 14.1.4 Test scanner (11) The test scanner option allows the barcode scanner to be tested. Scan a barcode then the barcode and the length of the barcode will be displayed on the screen. EDOI8954 Page 24 Issue 01

15 Specification Supply SBOX-Max / SBOX-Max BC Minimum Typical Maximum Input voltage 195v 230v 265v Input frequency 40Hz 50Hz 60Hz Input current 16A Generator rating 4.2KVA 6KVA Output SBOX-Max / SBOX-Max BC Minimum Typical Maximum Output voltage 40v Auto fitting 39.0v 39.5v 40.0v Output voltage barcode & manual 10.0v 48.0v Output current 2A 60A 60% Duty Cycle ISO12176-2 60A Peak current <60seconds 80A Operating modes SBOX-Max SBOX-Max BC Fusamatic 20 to 900 seconds Manual 10 to 3500 seconds Barcode Memory SBOX-Max / SBOX-Max BC Memory capacity Up to 2000 Records Backup to SD card Data output SBOX-Max / SBOX-Max BC USB memory device Environment SBOX-Max / SBOX-Max BC Minimum Maximum Operating temperature -10 C +40 C Storage temperature -15 C +55 C Environmental protection IP54 Dimensions Width Depth Height Without cloth bag & cables coiled 24cm 32cm 31cm Cable length SBOX-Max / SBOX-Max BC Input cable 3m Output cable 2.5m Weights SBOX-Max SBOX-Max BC Box with leads 16.8Kg 17.0Kg Cloth bag 2Kg Standards ISO12176-2 Electrofusion ISO12176-2 Classification ISO12176-3 Operator Badge ISO12176-4 Traceability Coding SBOX-Max / SBOX-Max BC P23US2FVKADX SBOX-Max BC EDOI8954 Page 25 Issue 01

16 Rights Due to Fusion's policy of continued development and improvement, we reserve the right to modify products without prior notice. 17 Accessories Below is a list of accessories and Fusion order numbers: Order No. Description 742182 Memory stick 742346 SBOX Barcode Kit (Fitted by an authorised service centre) 742229 4mm Lead Ends EDOI8954 Page 26 Issue 01

Appendix A SBOX-Max Manual entry character set The SBOX-Max character sets are shown below: A.1 Number character set. 0 1 2 3 4 5 6 7 8 9. - +, ( - represents a SPACE). A.2 ABC font set A.2.1 Upper case characters A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A.2.2 Lower case characters a b c d e f g h I j k l m n o p q r s t u v w x y z When the green button is held down for more than 3 seconds when on the selected character the following characters will be displayed. Selected character Displayed characters Selected character Displayed characters A À Á Â Ã Ä Å Ā Ǎ Ă Ą a à á â ã ä å ā ǎ ă ą C Ç Ć Ĉ Ċ Č c ç ć ĉ ċ č D Ď E È É Ê Ë Ē Ĕ Ė Ę Ě e è é ê ë ē ĕ ė ę ě G Ĝ Ğ Ġ Ģ g ĝ ğ ġ ģ H Ĥ h ĥ I Ì Í Î Ï Ĩ Ī Ĭ Į İ i ì í î ï ĩ ī ĭ į J Ĵ j ĵ K Ķ k ķ L Ĺ Ļ Ŀ Ł l ĺ ļ ŀ ł N Ñ Ń Ņ Ň Ŋ n ñ ń ņ ň ŋ O Ò Ó Ô Õ Ö Ø Ō Ŏ Ő o ò ó ô õ ö ø ō ŏ ő R Ŕ Ŗ Ř r ŕ ŗ ř S ß Ś Ŝ Ş Š s ś ŝ ş š T Ţ Ť t ţ U Ù Ú Û Ü Ũ Ū Ŭ Ů Ű Ų u ù ú û ü ũ ū ŭ ů ű ų W Ŵ w ŵ Y Ý Ŷ Ÿ y ỳ ÿ ŷ Z Ź Ż Ž z ź ż ž EDOI8954 Page 27 Issue 01

A.3 Russian SBOX-Max Electrofusion Control Unit A.3.1 Upper case characters A Б B Г Д E Ж З И Й K Л M H O П P C T У Ф X Ц Ч Ш Щ Ъ ЭЮ Я A.3.2 Lower case characters а б в г д е ж з и й к л м н о п р с т у ф х ц ч ш щ ъ эю я When the green button is held down for more than 3 seconds when on the selected character the following characters will be displayed. Selected character Displayed characters Selected character Ъ Ь Ы ъ ь ы A.4 Japanese A.4.1 Upper case characters アカサタナハマヤラワ A.4.2 Lower case characters ァヵサッナハマャラヮ - Displayed characters When the green button is held down for more than 3 seconds when on the selected character the following characters will be displayed. Selected character Displayed characters Selected character アイウエオァィゥェォ カキクケコヵ サシスセソサ タチツテトッチッテト ナヌニネノンナ ハヒフヘホハ マミムメモマ ヤユヨャュョ ラリルレロラ ワヲヮ A.5 Symbol! # $ % & ( ) * ` / : ; < = >? @ [ ] ^ { } ~ ± μ Ω Displayed characters EDOI8954 Page 28 Issue 01

Fusion Group Limited Smeckley Wood Close Chesterfield Trading Estate Chesterfield Derbyshire S41 9PZ Tel: + 44 (0) 1246 268666 Fax: + 44 (0) 1246 268052 Email: sales@fusiongroup.com Web: www.fusiongroup.com EDOI8954 Page 29 Issue 01