Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Similar documents
Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

Tel: AC Power for Business-Critical Continuity TM

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

MP7. Uninterruptible Power Supply

Liebert SX TM. 60kVA to 200kVA UPS Three Phase Input, Three Phase Output

Liebert NXC from 10 to 60kVA

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

Liebert Hipulse E Hi-Availability UPS. Power Quality Solutions. Compact Footprint. Multi Bus Compatible. Wide Input Voltage & frequency Ranges

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert Hipulse E Liebert Hipulse E

Liebert. APM Family Series Enterprise-grade, Scalable & Superior Power Solutions for Mission-Critical Applications

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

The Power of Modularity

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert NXC from 10 to 200 kva

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

MGE Galaxy /900 kva

Modular UPS S KVA

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Liebert APM. The Compact Row-Based UPS With FlexPower Technology TM. AC Power for Business-Critical Continuity

Liebert. ITA2 TM UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Liebert GXT MT kva

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

Eaton 9EHD Industrial UPS

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

TME Modular Series UPS System kva/kw - 208/220 VAC

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

SMARTONLINE E3 UPS SYSTEMS

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Liebert exm TM. 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

Power Quality Book. Hipulse System Guide UPS FOR THE DIGITAL WORLD. Version 1.0

Sirius series. on-line

Liebert NX, kva/kw UPS Maximum Efficiency in a transformer-free, High Efficiency, Scalable On-line UPS EFFICIENCY. AVAILABILITY.

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

Powerware P95

UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

Socomec Netys PR RT U P S TOWER / RACK MOUNT

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

Liebert APM. The Compact Row-Based UPS With Flexpower Technology TM. AC Power for Business-Critical Continuity

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

UPS Operating Modes: A Global Standard. A White Paper from the Experts in Business-Critical Continuity

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

VERTIV SERVICE CAPABILITY

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

9900AUPS. Efficiency UNINTERRUPTIBLE POWER SUPPLIES 80KVA 225KVA

Schneider Electric Easy UPS 3S

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

9900B UPS. The POWER of Green UNINTERRUPTIBLE POWER SUPPLIES

ELEKTRA SMALL FOOT PRINT SERIES. Mission Critical & I.T Grade UPS I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 200KVA (3/3)

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Power Quality Solutions Eaton 93PR UPS

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

Business continuity made easy

7011A Series Single-Phase

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

Transcription:

TM Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds and services mission critical technologies that enable vital applications for data centers, communication networks, and commercial and industrial environments We support today's growing mobile and cloud computing markets with our portfolio of power, thermal and infrastructure management products, software and solutions, all complemented by our global service network. We help strengthen the world's most vital applications by bringing together global reach and local knowledge, and our decades-long heritage including brands like ASCO, Chloride, Liebert, NetSure and Trellis. Vertiv Your Vision, our Passion With a unique combination of industry expertise, technology and resources, our mission is to support and power mission-critical technologies that drive possibility. Service and Consultation Software Unified Infrastructure Thermal Management IT Management Power Management Our global critical power switching, control, and management solutions, engineered to the most demanding specifications, ensures power, reliability, compliance and Our global industrial power solutions meet the most demanding technical specifications and provide safe, reliable power- no matter the challenge Our global intelligently engineered DC power systems deliver high availability, energy efficiency and scalability for converged networks Our global power and thermal management solutions are some of the world s most efficient and reliable power and cooling technologies Our industryleading software gives customers an integrated view of operations across IT and facilities resources, enabling better decisions that save time and money

TM The Liebert Hipulse-U offers a reliable, scalable and user-friendly solution to ensure availability of various critical TM applications. The Liebert Hipulse-U offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs. Information Technology Large Internet Data centers Coloration Facilities Server Farms Internet Service Providers Telecommunication Mobile (3G,4G) Fixed (including WLL) MSC, BSC centers Industrial Automation Process Control Equipment Motion (digital drives and robotics) Transport Automation Airport automation Railways and Road transport automation and ticket booking Corporate Parks Banking, Insurance and Financial Services. Credit Card Operation Stock Exchange Operation Software Development Houses/Software Technology Parks BPO/KPO/EPO Operation Building Automation Access Control Security System Fire Alarm System Medical Diagnostics Magneto Resonant Imaging CT Scanning/Cath Lab Multiple medical imaging units Satellite Uplinking Earth Stations Broadcasting & Entertainment

Feature-Loaded UPS We have studied the emerging needs of our customers and have engineered what we have learned into the new, upgraded Liebert Hipulse- TM U. Now it offers you more value and power per square meter. You will find TM that the Liebert Hipulse-U offers unique features that address the needs of you business today and is designed to handle the needs that are anticipated in the future. Built Investment Protection Automatic battery testing Field settability of EOD of the battery Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour) Protection against deep discharge of battery Short-circuit proof inverter Back-feed protection D-level lightning protection With 3 auxiliary power supply to ensure redundancy under any condition Standard dry contacts Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range Choice of array of input harmonic filter options Temperature-compensated battery charging (optional) Features To Protect Your Network Fully Digital, twin DSP controlled Rated at 0.9 output power factor to deliver more active power Handle leading power factor loads without KW derating under specified conditions On-Line Double Conversion IGBT-based PWM Inverter Wide input voltage tolerance(+20/-20%) Wide input frequency range of 45Hz to 65Hz High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds) Capability to handle: High crest factor loads 100% non-linear loads 100% unbalanced loads Built-in maintenance bypass Front access for spares replacement and preventive maintenance Easy Dual bus configuration architecture Adjustable frequency synchronization window up to 6% in the static bypass Field protocols ModBus / Jbus Network protocols SNMP Overload capability of the UPS: 110% Ful load for 60 minutes 125% full load for 10 minutes 150% full load for 1 minutes Compact footprint

Selected Configurations Hipulse U is scalable to maximum 6 units using any of the following configurations to achieve either scalability or redundancy of desired percentage 1+N Configuration with distributed bypass System Up to six units in parallel Bypass 1+N configuration without any kind of centralized static switch Augment the system reliability Increase the availability of quality power following the load demand even if it was not forecasted or planned at the beginning of the project: ease of techno-ecnonmic expandability Enhanced the maintainability UPS 1 UPS 2 UPS 6 The total load is less than or equal to the rating of the single UPS (depending on the desired redundancy level) and is shared among all units LOAD Hot Stand-by Configuration Feed one (Priority) or two (Priority and load banks depending on the application need Increase the reliability of the priority load Bypass Enhanced the maintainability and reliability Easy connection Priority Load Can be implemented in the existing installation regardless of the UPS size, manufacturer & its control. Dual Bus System with Liebert LTS, STS2 or Hiswitch2 Provide supply to the loads from two independent power sources Synchronizes the output of two independent bus Automatic transfer of the load between the two sources in case of fault using Liebert LTS Increase dramatically the maintainability and reliability Bypass Bypass UPS 1 UPS 6 UPS 1 UPS 6 Liebert LTS LBS LOAD1 Liebert LTS LOAD2

Liebert Hipulse U Accessories Intelligent Paralleling Intended to increase system efficiency and to reduce the operating hours on the UPS This feature will put one or more paralleled units into standby operation when number of redundant modules is above the user-specfied threshold Liebert Active Filter Optional super filter to reduce THDi to <5% and improve input PF up to 0.93 without additional system footprint. Isolation Transformer Additional transformer for output or bypass supply depending on application Communication Options When choosing the best system to protect your mission critical applications, an important consideration would be the software and communication options, As part of our commitment to provide the best solution for you, we offer a wide range of sophisticated software and communication options for Hipulse-u. Rectifier or Bypass supply This allows UPS to be configured in Single or Dual Main supply to ensure system adaptability and reliability DC Ground Fault Indications This provides indication of occurrence of battery ground fault problems Protection Degree (IP) To address stressed environmental conditions, Hipulse-U UPS with higher than IP 20 degree of protection can be made available for most of the kva ratings Top Cable Entry Available for a wide range of our Hipulse-U ratings Load Bus Synchronisation (LBS) Ensures the synchronisation of outputs of two independent UPS systems to form Dual Bus Architecture for High availability of Critical BUS Control through Building Management Systems via Modbus and Jbus protocols Web-enabled Monitoring and Management through SNMP protocols Network Management Systems ready (HP OpenView, CA Unicenter, Novell Managewise, etc) Software Solutions Site Monitor Software Facility wide monitoring by SiteScan Shutdown software for your computer Liebert LTS, STS2 or Hiswitch2 This allows critical load to be automatically transferred between two independent, synchronized AC power sources without any risk of load disturbances TVSS (Transient Voltage Surge Suppressor) This offers protection from damaging transients and electrical line noises This is normally connected at the bypass path of Hipulse-U or inside the Static Transfer Switch as an optional item

Specifications Nominal Ratings(kVA/kW) 80 100 120 160 200 300 400 500 Rectifier Type 6P 6P 6P 12P 6P 12P Input 6P 12P 6P 12P 6P 12P 12P Nominal input voltage Input voltage range Nominal input frequency Input frequency range Input current distortion with linear load (with filter) Power factor (with filter) Output Nominal output voltage 380/400/415Vac 4-wire plus ground 290 to 498Vac 50/60Hz 40-70Hz 3 to 10% with optional filter 0.88 to 0.97 with optional filter 380/400/415Vac 4-wire plus ground Frequency Voltage stability Transient recovery time Frequency stability Overload capability ±1% (Steady state); ±5% (Transient state) 20 milliseconds (mac) ±0.1% (Synchronized with internal clock); ±6% (max)(synchronized with bypass) 105%, 60minutes; 125%,10minutes; 150%, 1 minutes; >150%,<200 millisecond Voltage distortion with linear load Voltage distortion with 100% Non- linear load <1% <5% <3.5% Permissible load unbalance 100% Non linear load capability Load handing capability without kva derating Phase angle displacement accuracy Dimensions and weight Depth (mm) Width (mm) Height (mm) Weight(kg) 100% balanced load 100% unbalanced load 100% 0.5 lagging to 0.9 leading o ±1 o ±1 855 900 1540 1250 1640 1240 1740 1640 2280 2640 1900 900 1400 1200 1750 1200 1850 1600 2550 2200 2900 General General and safety requirements for UPS IEC 62040-1 EMC requirements for UPS IEC 62040-2 UPS classification according to CENIEN 6240-3 VFI-SS-111 *Conditions apply Specifications are subject to change without any prior notification

? 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.