LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

Similar documents
A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

STG 2000 modules. Description

PROTECTION SYSTEMS. 1st Edition

CATEGORY 6 PATCH BY EXCEPTION SOLUTION (PBE) Modules Frames and Covers Labelling and Accessories Patch Leads Cable Management

Family of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits

Inside LSA-PLUS. Because your network is worth it. Lower costs

Protection systems. 1st Edition

ANSI/TIA/EIA-568-B Cabling Standard

Cabling Infrastructure

9/27/04 cci Cablecom Inc. 1

Modular splicing connectors

KRONE HIGHBAND for Broadband Delivery Transporting tomorrow's technology...today. AccessNET

BcN. PART?. BcN Overview PART?. Realization of BcN PART?. Broadband of Wireless Access. PART?. Standard Model of BcN

CELL SITE INFRASTRUCTURE SOLUTIONS. Creative Solutions for the Mobile Evolution

ITU-APT Regional Seminar. BcN. (Broadband Convergence Network) Inje University, Rep. Korea ChulSoo Kim 10 Sep INJE univ.

Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter

Wired communication refers to the transmission of data over a cable. Some examples include telephone networks, cable television or broadband internet

Flexible wireless connectivity solutions

Teleline Product Selection Guide

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.

A significantly increased capacity compared to other techniques is achieved with the compact SID-C module.

Siemon PON Fiber Cabling Solutions

3M Quick Connect System (QCS) 2811

The most flexible home network, with television, phone and data on the same cable

3M Quick Connect System (QCS) 2814

WHITE PAPER. Patch-by-Exception. How to save time and money while improving performance, manageability, security and aesthetics.

Experiment # 2 Transmission Media & Networking Components

Multiplexing (Recap)

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

Category 5e Solutions

The changing route to the last mile

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

TEX-100. Ethernet Extender User Manual

This specification this document to get an official version of this User Network Interface Specification

6220 Ethernet-Based Voltage Measurement Module

Over Voltage Protection Standardization in Japan

TELECOMMUNICATION SYSTEMS

Plug and Operate Transformer Technology

Unit 09 Computer Networks

Ch. 5 - ISDN - Integrated Services Digital Network

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

Physical Layer Part 3

DS1 Isolation Cards. P Wire Card P Wire Card. Description & Installation

Model CFA-24 Transparent Cable Farm Automation Switch

ISO/IEC 11801: (E)

VDTU2-B110 VDSL2 LAN Extender

The following pages contain a guide for the installation

Computer Networks. Week 04 Media and Devices. College of Information Science and Engineering Ritsumeikan University

with its cables, connectors, Switches, Hubs and topologies

ITSF 2007 overview of future sync applications and architecture challenges

The next-generation access network : transition from copper to fiber optics

Voice Integration Overview

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

ex-s1110-xt Gigabit Ethernet Extenders

Introducing Phonelines Home Networking

Enabling Rapid Multitenant Data Centre (MTDC) Connections

Delivering next-generation fibre throughout every building

wi4 Fixed Point-to-Multipoint Canopy Solutions

Wireless Router. Model: SR350N. User Manual V 1.1

CHAPTER 7 Copper Cable Testing

selos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail

AfriConnect Satellite Technology Overview

Airmux-400, Airmux-5000 Optional Accessories

Physical Layer Part 3

3630 MAINSTREET. Intelligent, high perfomance multiplexing that terminates up to 31 voice or data circuits. PRIMARY RATE MULTIPLEXER Release 5.

[.050 (1.27mm) Density. D-Microminiature]

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

RiT SMART Cabling Solution

Multistation Access Unit User s Guide

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

TCP/IP and OSI Model Ethernet LAN Network Cables Network Devices Network Topologies Redundant Internet Connections VLANs Wireless LANs Upcoming

User s Manual. VDSL CO / CPE Modem. Model No.: SP3501AM/SP3501AS.

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Integrated t Services Digital it Network (ISDN) Digital Subscriber Line (DSL) Cable modems Hybrid Fiber Coax (HFC)

Siemon and Moorings Park Prove That Technology Never Retires

About Lantiq: Product Portfolio

General Description. Multi-Service Access Platform. 3/03/ W-Rev3

Total Reach ISDN/DDS Isolation Card P P30059 Isolation Card

SERVICE MANUAL MODEL SSP-561-X-ADA

NZQA unit standard version 2 Page 1 of 6. Demonstrate knowledge of telecommunications core network systems and services

SERVICE MANUAL MODEL SSP-350-X

System Overview. Applications. System Architecture. Features

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Uniprise Structured Cabling Solutions Guide

NETWORK ARCHITECTURE

Instructions for the Ethernet - Product Operated Network Interface used with Ethernet Networks I.L

TEMS PRODUCTS THE ONLY BENCHMARKING SOLUTION YOU LL EVER NEED

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

SoundwebTM. Installation Guide

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

Connecting a Cisco Input Module

07. har-link Interface Connectors

MXK: Intelligent Terabit Access Concentrator

07. har-link Interface Connectors

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

MX62 Series. Right Angle Pin Connector Socket Connector In-line connector

Transcription:

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 1 st Edition

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially superior quick connection system for all state-of-the-art networks. Contacts that ensure the highest degree of reliability even under the most adverse environmental and climatic conditions. A completely reliable, gas-tight connection between the contact and conductor. That's LSA-PLUS technology. The LSA-PLUS System family consists of a comprehensive and diverse range of high density, standard and special modules, mounting hardware, test and patch cords, accessories and protection devices. Voice, high-speed data transmission via ISDN, ADSL, VDSL, cable TV, Internet access, mobile networks: working in conjunction with TE Connectivity you will be able to confidently face the issues created by vast amounts of network traffic. In addition, TE quality ensures total end-customer satisfaction. TE copper connectivity solutions are designed to deliver fast, safe and reliable transmission. 2 www.te.com/adc 1-919-557-8900 Fax: 1-919-557-8498 08/11 201621BE

LSA-PLUS and LSA PROFIL Connection Modules Series 2 Eight- and Ten-Pair Modules Based on genuine LSA-PLUS connection technology Available in eight- and ten-pair configurations with parallel test access or overvoltage protection contact LSA-PLUS modules mount on back mount frames LSA PROFIL modules mount on profile rods (8-pair modules: 75mm spacing between rods; 10-pair modules: 95mm spacing between rods) or on back mount frames Suitable for use in all xdsl and ADSL2+ circuits Robust long-term environmental stability allows both indoor and outdoor installation Supports all LSA-PLUS Series 2 accessories Overvoltage protection magazine Labels Test and connection cords 8-pair modules LSA-PLUS Series 2 connection module, cable end up, no color code. Printed: jumper side 1.8 LSA PROFIL Series 2 connection module, no color code. Printed: jumper side 1.8 6036 1 002-00 6036 1 004-00 10-pair modules LSA-PLUS Series 2 connection module Cable end up, no color code. Printed: jumper side 1.0 6089 1 002-02 Cable end up, with color code. Printed: jumper side 1.0 6089 1 002-01 Cable end up, no color code. Printed: jumper side 0.9 6089 1 002-06 LSA PROFIL Series 2 connection module No color code. Printed: jumper side 1.0 6089 1 120-02 With color code. Printed: jumper side 1.0 6089 1 120-01 No color code. With large jumper guides. Printed: jumper side 1 0 6089 1 120-19 No color code. No jumper guides. Printed: jumper side 1.0 6089 1 120-23 3 www.te.com/adc 1-919-557-8900 Fax: 1-919-557-8498 08/11 201621BE

LSA-PLUS and LSA PROFIL Disconnection Modules Series 2 Eight- and Ten-Pair Modules Eight- and ten-pair modules with disconnection points for opening the line, testing in both directions or insertion of graded protection elements Based on genuine LSA-PLUS connection technology LSA-PLUS modules mount on back mount frames LSA PROFIL modules mount on profile rods (8-pair modules: 75 or 95mm spacing between rods; 10-pair modules: 95mm spacing between rods) or on back mount frames Suitable for use in all xdsl and ADSL2+ circuits Robust long-term environmental stability allows both indoor and outdoor installation Supports all LSA-PLUS Series 2 accessories Overvoltage protection magazine Labels Test and connection cords 8-pair modules LSA-PLUS Series 2 disconnection module, no color code. Printed: jumper side 1.8 Quantity: 10 LSA PROFIL Series 2 disconnection module. For profile rod installations with 75mm spacing between rods. No color code. Printed: jumper side 1.8 6036 1 102-00 6036 1 005-00 LSA PROFIL Series 2 disconnection module. For profile rod installations with 95mm spacing between rods. No color code. With jumper guides. Printed: jumper side 1.8 6089 1 128-00 No color code. With jumper guides. Printed: jumper side 1.8 6089 1 128-01 No color code. With large jumper guides. Printed: jumper side 1 8 6089 1 128-02 No color code. With jumper guides; no dummy insert. Printed: jumper side 1.8 6089 1 121-47 10-pair modules LSA-PLUS Series 2 disconnection module No color code. Printed: jumper side 1.0 6089 1 102-02 With color code. Printed: jumper side 1.0 6089 1 102-01 No color code. Printed: jumper side 0.9 6089 1 102-06 With color code. Printed: jumper side 1 0 6089 1 102-09 LSA PROFIL Series 2 disconnection module No color code. Printed: jumper side 1.0 6089 1 121-02 With color code. Printed: jumper side 1.0 6089 1 121-01 No color code. With large jumper guides. Printed: jumper side 1 0 6089 1 121-17 No color code. No jumper guides. Printed: jumper side 1.0 6089 1 121-30 4 www.te.com/adc 1-919-557-8900 Fax: 1-919-557-8498 08/11 201621BE

LSA PROFIL Series 2 Disconnection Module for 2 Mbps Networks DESCRIPTION The expansion of mobile communications networks, the introduction of new mobile phone systems (3G, UMTS, 4G, LTE) and the steady growth of IP networks, have created a demand for bandwidth in both access and transmission networks. This in turn causes the extension of existing hubs and the installation of new hubs. The ADC KRONE PROFIL system provides a foundation for networks served by 2 Mbps copper pairs with impedance of 120 Ohms. Disconnection module for the distribution of eight shielded pairs Applications include: Internet backbone GSM networks UMTS networks Complies with ITU-T G.703 recommendations (physical/electrical characteristics of hierarchical digital interfaces) Category 6-rated NEXT performance Compatible with a wide-range of LSA-PLUS Series 2 accessories Accessories disconnect only the Line A/Line B contacts, while the shielding remains interconnected. Plugs and cords are available to disconnect the shield, should that be required Ports are marked on the module LSA PROFIL Series 2 8-pair disconnection module for shielded twisted pair With left and right jumper guides 7015 1 008-01 With 3 wire guides for jumpers to the left 7015 1 004-50 With 3 wire guides for jumpers to the right 7015 1 005-50 Accessories Hinged label holder 7015 1 003-50 Cable support with cable mounting and shield contact for 1 cable with 8 pairs Depth: 12mm Cable support with cable mounting and shield contact for 8 cables with 1 pair Depth: 3mm 7015 1 009-01 7015 1 009-11 Universal cable support for 1-, 2- and 4-pair cables. Depth: 3 6mm 7015 1 009-21 5 www.te.com/adc 1-919-557-8900 Fax: 1-919-557-8498 08/11 201621BE