Quick Start Guide. Installation. User s Manual 1

Similar documents
Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Quick Start Guide. Installation. Physical Description.

Hardened PoE Ethernet Switch

10/100Base-TX Industrial Ethernet Extender

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Quick Start Guide. Physical Description.

Hardened Media Converter

Industrial Ethernet Switch

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Industrial PoE Media Converter

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Quick Start Guide. Physical Description. The Port Status LEDs

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Signamax Connectivity Systems

10/100Base-TX Industrial Ethernet Extender

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

XPress-Pro SW User Guide

Hardened Web-Smart High Power PoE Ethernet Switch

XPress-Pro SW User Guide

Signamax Connectivity Systems Industrial Ethernet Extender. User s Guide

Manual. Preface. XSNet 3100MC

Gigabit Ethernet Media Converter

Preface. Media Converter

Signamax Connectivity Systems Industrial 10/100BASE-TX Ethernet Extender

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

Signamax Connectivity Systems Dual Rate SFP Converter Series U S E R S

A valid network connection established. Transmitting or receiving data. ACT stands for ACTIVITY.

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

Gigabit Ethernet Media Converter

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

10/100BASE-TX to 100BASE-FX Media Converter. User s Guide. Rev. 01 (JUN. 2002) 1907M110MM16003 RECYCLABLE

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

ED3541 Hardened Ethernet Extender. User s Guide. FastFind Links. Introduction. Unpacking and Installation

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

Modular 8-Port Mid-span Power over Ethernet Injector

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Installation and Operation Manual

The Gigabit Ethernet Media Converter fully complies with IEEE802.3ab 1000Base- T and IEEE802.3z 1000Base-SX/LX Gigabit Ethernet standards.

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Rugged Industrial Media Converter

IEEE BASE-T IEEE 802.3u 100BASE-TX. ITU-T -G.993.1(VDSL) -G compatible

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Quick Start Guide. Physical Description. Gigabit Ethernet Media Converter. User s Manual 1. Product Overview. DIP Switch

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

EDS-G205A-4PoE Hardware Installation Guide

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

5-Port Industrial Ethernet Switch - DIN Rail Mountable

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

8-port 10/100Base-TX Switch (INS-806) User s Guide

Industrial 3-Port Fast Ethernet Media Converter Switches

LevelOne FSW PoE Fast Ethernet Switch User Manual

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

USER MANUAL. Industrial GBE High Power PoE Injector up to 60W, IEEE802.3af/at, 2xRJ-45 Data In/ PoE Out, VDC power input, -40..

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

MOXA EtherDevice Switch & PoE Splitter

ST-POEAF-S16-RM. 16 port PoE switch. User Guide

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

INJ-24A Series Quick Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Industrial 8-port unmanaged Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E., 24VDC power inputs

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

TN-5308 Quick Installation Guide

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

LNX-0702G-SFP Series

EDS-G205A-4PoE Quick Installation Guide

5-Port Hardened Industrial Gigabit DIN-Rail Switch

Stride Industrial Ethernet Switches

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Preface. Manual Revisions. Trademarks

IMC-21 Quick Installation Guide

ex-s1110-xt Gigabit Ethernet Extenders

IMC-P111FX / IMC-P111P Series

Transcription:

Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Installation ED3538T (Transmitter): This is a PoL (Power over Link) transmitter. Data and power can be delivered at the same time through one pair copper wire to turn on and communicate with ED3538R (Receiver) via RJ-11 phone jack or 2-pin Terminal Block interface. ED3538R (Receiver): This is a PoL (Power over Link) Receiver. ED3538R (Receiver) can be powered either by ED3538T (Transmitter) through one pair copper wire or power supply. The Ethernet port supports IEEE802.3at PoE/PSE for fulfilling PoE/PD application. <Warning> Removes the device power before installation. Removes the device power before any I/O and DIP switch configuration. Do not connect ED3538T and ED3538R to the same power source. Devices may be damaged due to power loop back through the PoL linked via copper wire. PoL (Power over Link) Mode Enable Installation Ensures all power sources are disconnected from ED3538T and ED3538R. Ensures ED3538T PoL (Power over Link) DIP switch is in On position (Up position). Sets ED3538T Type DIP switch to Perf (Performance, Up position) to acquire better Line Speed (but poor noise immunity). Or sets Type DIP switch of ED3538T to Std (Standard, Down position) to acquire standard Line Speed (but better noise immunity). Checks if ED3538R Mode is set to Rmt on DIP switch (Remote, Up position). Connects one end of the one pair copper wire to RJ-11 phone jack or 2-pin Terminal Block interface of the ED3538T and the other end to RJ-11 phone jack or 2-pin Terminal Block interface of the ED3538R. Connects power source to ED3538T. Data and power can be delivered from ED3538T, and at the same time through one pair copper wire to turn on and communicate with ED3538R. <Note> The equipment is designed for building installation and not intended to be connected to exposed (outside plant) networks including campus environment or equivalent. PoL (Power over Link) Mode Disable Installation For longer distance (e.g. over 1.4km) extension application, ED3538R may not be able to receive power from ED3538T. A separate power may be applied on ED3538R. Ensures all power sources are disconnected from ED3538T and ED3538R. Ensures ED3538T PoL (Power over Link) DIP switch is in Off position (Down position). Sets ED3538T Type DIP switch to Perf (Performance, Up position) to acquire better Line Speed (but poor noise immunity). Or sets Type DIP switch of ED3538T to Std User s Manual 1

(Standard, Down position) to acquire standard Line Speed (but better noise immunity). Connects power source to ED3538T. Checks if ED3538R Mode is set to Rmt on DIP switch (Remote, Up position). Connects power source to ED3538R. Connects one end of the one pair copper wire to RJ-11 phone jack or 2-pin Terminal Block interface of the ED3538T and the other end to RJ-11 phone jack or 2-pin Terminal Block interface of the ED3538R. Data can be transmitted between ED3538T and ED3538R via copper wire. Physical Description The Port Status LEDs and Power Inputs ED3538T ED3538R DC Terminal Block Power Inputs: 2.5A @ 48VDC (Peak current 3.26A). There are two pairs of power inputs can be used to power up this Ethernet Extender. Redundant power supplies function is supported. You only need to have one power input connected to run the Ethernet Extender. DC JACK Power input: 2.5A @ 48VDC (Peak current 3.26A). Power supply suggestion SDR-120-48 / DR-120-48 (120W 48VDC) SDR-240-48 (240W 48VDC) SDR-480-48 (480W 48VDC) 30 watts application For one pair For three pairs For seven pairs User s Manual 2

Power Input Assignment Power1 48VDC DC Jack + T:46-57V / R:46-57V DC Power2 - Power Ground + T:46-57V / R:46-57V DC Terminal Power3 - Block Power Ground Earth Ground DIP Switch Down Up ED3538T PoL Disable Power over Link Enable Power over Link Type ED3538R Mode Type Std (Standard) Standard line speed Better noise immunity Loc (Local) Set ED3538R to Local Mode Std (Standard) Standard line speed Better noise immunity Perf (Performance) Better line speed Poor noise immunity Rmt (Remote) Set ED3538R to Remote Mode Perf (Performance) Better line speed Poor noise immunity LEDs State Indication Power Steady Power received 1/2/3 Off Power off Steady Power Ethernet extension interface function is enabled PoL No power is transmitted over Ethernet extension Off interface PoE Steady Powered device (PD) is connected Off Powered device (PD) is disconnected Steady A valid Extender connection established Fast Link Flashing Data transmission or receiving Slow Flashing Extender port under negotiation mode Off Extender interface connection is not established Line Speed Steady Displays the link speed in Mbps PSE Steady PoE power can be transmitted for PD Output All off No PoE power can be transmitted for PD Steady A valid Ethernet connection established Green Flashing Data transmission or receiving Off Non-Ethernet connection is established Yellow Steady Link speed at 100Mbps Off Link speed at 10Mbps User s Manual 3

Power over Link (PoL) Enabled Distance Data Rate ED3538R PoE Output 300M 100Mbps 30.0W 400M 90Mbps 15.4W 600M 60Mbps 14.0W 800M 45Mbps 9.5W 1000M 35Mbps 7.0W 1200M 20Mbps 5.0W Power over Link (PoL) Disabled Power Supply Applied on ED3538R Distance Data Rate ED3538R PoE Output 1400M 15Mbps 30.0W 1600M 10Mbps 30.0W 1800M 3Mbps 30.0W Up to 2200M 1Mbps 30.0W <Note> The Reference Performance is tested on 24AWG Telephone wire (0.5mm diameter, 1-pair wire, Cable impedance: 100ohm). 10/100Base-TX and Ethernet Extender Connectors 10/100Base-TX Connection The following lists the pinouts of 10/100Base-TX RJ-45 port. Pin Regular Port PoE Port 1 Output Transmit Data + Output Transmit Data + 2 Output Transmit Data - Output Transmit Data - 3 Input Receive Data + Input Receive Data + 4 Positive (VCC+) 5 Positive (VCC+) 6 Input Receive Data - Input Receive Data - 7 Negative (VCC-) 8 Negative (VCC-) User s Manual 4

Ethernet Extender Connection The RJ-11 and Terminal Block port pinouts Pin 3: Tip, Pin 4: Ring. Use a telephone line to connect two RJ-11 or Terminal Block ports between two Hardened Ethernet Extenders. Functional Description Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment. Ethernet port: Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex; Auto MDI/MDIX. Auto data rate negotiation for Ethernet extension interface. Six speeds with speed indicator LEDs on front panel of unit, up to 100Mbps @ about 300meters (984ft.), down to 1Mbps @ about 2,200meters (7,218ft.). Supports Power over Ethernet application up to 1,200meters (3,937ft.) for Max. 5 watts power consumed PoE powered devices. Power consumption: - Enable Power over Link (PoL) function: Max. 65Watts - Disable Power over Link (PoL) function: ED3538T: Max. 5W. ED3538R: Max. 35W with PoE output, Max. 5W without PoE output. Power Supply: Redundant T:46-57V / R:46-57V DC Terminal Block power inputs and 48VDC Latched DC JACK interface. Operating temperature range @ -40 to 75 (-40 to 167 ). Tested for functional operation @ -40 to 85 (-40 to 185 ). Supports Din-Rail or Panel Mounting installation. User s Manual 5

Preface This manual describes how to install and use the Hardened Ethernet Extender. The Hardened Ethernet Extender introduced here provides one channel for Ethernet over existing voice grade copper wire. The Hardened Ethernet Extender fully complies with IEEE802.3 10Base-T and IEEE802.3u 100Base-TX standards. In this manual, you will find: Product overview Features on the Hardened Ethernet Extender Illustrative LED functions Installation instructions Specifications User s Manual 6

Table of Contents Quick Start Guide... 1 Installation... 1 Physical Description... 2 The Port Status LEDs and Power Inputs... 2 10/100Base-TX and Ethernet Extender Connectors... 4 Functional Description... 5 Preface... 6 Table of Contents... 7 Introduction... 8 Product Overview... 8 Product Features... 8 Packing List... 9 One-Channel Hardened Ethernet Extender... 10 Ports... 10 Ethernet Extender Mode Settings... 10 DIP Switch... 10 Front Panel & LEDs... 11 LED Indicators... 11 10/100Base-TX and Ethernet Extender Connectors... 12 Installation... 13 Selecting a Site for the Equipment... 13 DIN Rail Mounting... 13 Connecting to Power... 15 Redundant DC Terminal Block Power Inputs... 15 48VDC DC Jack... 15 Specifications... 17 User s Manual 7

Introduction The Hardened Ethernet Extender provides one channel for Ethernet over existing voice grade copper wire. This Hardened Ethernet Extender solution is perfectly fitted in the industrial applications or rugged environment. Product Overview ED3538T ED3538R Product Features Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment. Ethernet port: Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex; Auto MDI/MDIX. Auto data rate negotiation for Ethernet extension interface. Six speeds with speed indicator LEDs on front panel of unit, up to 100Mbps @ about 300meters (984ft.), down to 1Mbps @ about 2,200meters (7,218ft.). User s Manual 8

Supports Power over Ethernet application up to 1,200meters (3,937ft.) for Max. 5 watts power consumed PoE powered devices. Power consumption: - Enable Power over Link (PoL) function: Max. 65Watts - Disable Power over Link (PoL) function: ED3538T: Max. 5W. ED3538R: Max. 35W with PoE output, Max. 5W without PoE output. Power Supply: Redundant T:46-57V / R:46-57V DC Terminal Block power inputs and 48VDC Latched DC JACK interface. Operating temperature range @ -40 to 75 (-40 to 167 ). Tested for functional operation @ -40 to 85 (-40 to 185 ). Supports Din-Rail or Panel Mounting installation. Packing List When you unpack this product package, you will find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to our authorized reseller. The Hardened Ethernet Extender User s Manual AC to DC Power Adaptor and Power Cable (optional) User s Manual 9

One-Channel Hardened Ethernet Extender Ports The Hardened Ethernet Extender provides TX ports and one Ethernet Extender port. For the TX ports, it uses RJ-45 connector and auto senses the speed of 10/100Mbps. For the Ethernet Extender port, it uses RJ-11 and Terminal Block connectors and auto senses the speed of Link (below 20)/20/40/60/80/100Mbps. Ethernet Extender Mode Settings Ethernet Extender mode settings are made very simple by means of a DIP (Dual Inline Package) switch on the top panel of the Hardened Ethernet Extender. DIP Switch DIP Switch Down Up ED3538T PoL Disable Power over Link Enable Power over Link Type Std (Standard) Standard line speed Better noise immunity Perf (Performance) Better line speed Poor noise immunity ED3538R Mode Loc (Local) Rmt (Remote) Set ED3538R to Local Mode Set ED3538R to Remote Mode Type Std (Standard) Standard line speed Better noise immunity Perf (Performance) Better line speed Poor noise immunity User s Manual 10

Front Panel & LEDs LED Indicators The LED indicators give you instant feedback on status of the Hardened Ethernet Extender: LEDs State Indication Power Steady Power received 1/2/3 Off Power off PoL Steady Power Ethernet extension interface function is enabled Off No power is transmitted over Ethernet extension interface PoE Steady Powered device (PD) is connected Off Powered device (PD) is disconnected Steady A valid Extender connection established Fast Link Flashing Data transmission or receiving Slow Flashing Extender port under negotiation mode Off Extender interface connection is not established Line Speed Steady Displays the link speed in Mbps PSE Steady PoE power can be transmitted for PD Output All off No PoE power can be transmitted for PD Steady A valid Ethernet connection established Green Flashing Data transmission or receiving Off Non-Ethernet connection is established Yellow Steady Link speed at 100Mbps Off Link speed at 10Mbps Power over Link (PoL) Enabled Distance Data Rate ED3538R PoE Output 300M 100Mbps 30.0W 400M 90Mbps 15.4W 600M 60Mbps 14.0W 800M 45Mbps 9.5W 1000M 35Mbps 7.0W 1200M 20Mbps 5.0W User s Manual 11

Power over Link (PoL) Disabled Power Supply Applied on ED3538R Distance Data Rate ED3538R PoE Output 1400M 15Mbps 30.0W 1600M 10Mbps 30.0W 1800M 3Mbps 30.0W Up to 2200M 1Mbps 30.0W <Note> The Reference Performance is tested on 24AWG Telephone wire (0.5mm diameter, 1-pair wire, Cable impedance: 100ohm). 10/100Base-TX and Ethernet Extender Connectors 10/100Base-TX Connection The following lists the pinouts of 10/100Base-TX RJ-45 port. Pin Regular Port PoE Port 1 Output Transmit Data + Output Transmit Data + 2 Output Transmit Data - Output Transmit Data - 3 Input Receive Data + Input Receive Data + 4 Positive (VCC+) 5 Positive (VCC+) 6 Input Receive Data - Input Receive Data - 7 Negative (VCC-) 8 Negative (VCC-) Ethernet Extender Connection The RJ-11 and Terminal Block port pinouts Pin 3: Tip, Pin 4: Ring. Use a telephone line to connect two RJ-11 or Terminal Block ports between two Hardened Ethernet Extenders. User s Manual 12

Installation This chapter gives step-by-step installation instructions for the Hardened Ethernet Extender. Selecting a Site for the Equipment As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements: The Surrounding Air temperature should be between -40 to 75 degrees Celsius. The relative humidity should be less than 95 percent, non-condensing. Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards. Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes of the equipment. The power outlet should be within 1.8 meters of the product. DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the Hardened Ethernet Extender. Installation: Place the Hardened Ethernet Extender on the DIN rail from above using the slot. Push the front of the Hardened Ethernet Extender toward the mounting surface until it audibly snaps into place. Removal: Pull out the lower edge and then remove the Hardened Ethernet Extender from the DIN rail. User s Manual 13

User s Manual 14

Connecting to Power Redundant DC Terminal Block Power Inputs or 48VDC DC Jack: Redundant DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this device. You only need to have one power input connected to run the Hardened Ethernet Extender. Step 1: Connect the DC power cord to the plug-able terminal block on the Hardened Ethernet Extender, and then plug it into a standard DC outlet. Step 2: Disconnect the power cord if you want to shut down the Hardened Ethernet Extender. 48VDC DC Jack Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of the Hardened Ethernet Extender. Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage. User s Manual 15

Power Input Assignment Power1 48VDC DC Jack + T:46-57V / R:46-57V DC Power2 - Power Ground Power3 + T:46-57V / R:46-57V DC Terminal - Power Ground Block Earth Ground User s Manual 16

Specifications Applicable Standards Fixed Ports Speed 10Base-T 100Base-TX Ethernet Extender Switching Method Forwarding rate Cable 10Base-T 100Base-TX Ethernet Extender LED Indicators Dimensions Weight Power Power Consumption IEEE802.3 10Base-T, IEEE802.3u 100Base-TX 10/100Mbps Ethernet ports with RJ-45 connectors 1 x Ethernet Extender port with RJ-11 and Terminal Block connectors 10/20Mbps for half/full-duplex 100/200Mbps for half/full-duplex Link (Below 20), 20, 40, 60, 80, 100Mbps Store-and-Forward 14,880/148,810pps for 10/100Mbps 4-pair UTP/STP Cat. 3, 4, 5 up to 100m 4-pair UTP/STP Cat. 5 up to 100m Telephone wires Per Unit (3 LEDs)- Power1, Power2, Power3 ED3538T- PoL; Line Speed (Mbps): Link, 20, 40, 60, 80, 100 ED3538R- PoE; Line Speed (Mbps): Link, 20, 40, 60, 80, 100; PSE Output (Watts): 5, 15, 30 50mm (W) 110mm (D) x 135mm (H) (1.97 (W) x 4.33 (D) x 5.31 (H)) 0.77Kg (1.7lbs.) Terminal Block: T:46-57V / R:46-57V DC DC Jack: 48VDC, External AC/DC required Terminal Block & DC Jack Power Inputs: 2.5A @ 48VDC (Peak current 3.26A) Enable PoL: Max. 65Watts Disable PoL: ED3538T: Max. 5W ED3538R: Max. 35W with PoE output Max. 5W without PoE output User s Manual 17

Operating Temperature -40 ~ 75 (-40 ~ 167 ) Tested for functional operation @ -40 ~ 85 (-40 ~ 185 ) Storage Temperature -40 ~ 85 (-40 ~ 185 ) Humidity EMI EMS Environmental Test Compliance 5 ~ 95%, non-condensing FCC Part 15, Class A EN61000-6-4: EN55022, EN61000-3-2, EN61000-3-3 EN61000-6-2: EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards) IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) IEC60068-2-32 Ed (Free Fall) User s Manual 18