User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Similar documents
Fruit Hardness Tester

User's Guide. Hot Wire Thermo-Anemometer. Model

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Vibration Meter SD Card real-time datalogger

Hygro-Thermometer / Datalogger

Light Meter SD Card real-time datalogger

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

User's Guide. Hot Wire Thermo-Anemometer Model

4-Channel Thermometer / Datalogger

Sound Level Meter SD Card real-time Datalogger

Heavy Duty Mini Vane CFM Thermo Anemometer

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Heavy Duty Vibration Meter

Large Vane CFM/CMM Thermo-Anemometer

12-Channel Thermocouple Datalogger

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

User Guide. Moisture Meter. Model MO250

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Torque Meter. Instruction Manual

Heavy Duty Datalogging Light Meter

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

ph/orp Meter SD Card real-time Datalogger

Large Vane CFM/CMM Anemometer / Psychrometer

USER GUIDE. AC/DC Magnetic Meter. Model MF100

Heavy Duty Vibration Meter

User's Guide. Vibration Meter and Laser Combination Tachometer Model

4-Channel Vibration Datalogger

Heavy Duty Hot Wire CFM Thermo-Anemometer

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Heavy Duty CFM Thermo-Anemometer Model

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

User's Guide. Video Borescope. Model BR100

User's Manual Sound Level Alert Model SL130

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User's Guide. Heavy Duty Differential Pressure Manometer. Model

Datalogging Hygro-Thermometer

Light Meter with Bar Graph

USER GUIDE Current Calibrator

Barometric Pressure / Humidity and Temperature Datalogger

Personal Sound Level Meter

User's Guide. Cup Thermo-Anemometer. Model AN400

Torque Meter. Instruction Manual

Vibration Meter and Laser Combination Tachometer

Digital Sound Level Meter

User's Guide. Datalogging Light Meter with PC Interface. Model

600 g x 0.02 g DIGITAL BALANCE

Laser Photo/ Contact Tachometer. m/min. ft/min

FG-7000 Digital Force Gauge Operation Manual

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

FG-3000R Digital Force Gauge Operation Manual

Heavy Duty Datalogger Module

NIDEC-SHIMPO INSTRUMENTS

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

3 Channel Datalogging Thermometer

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Digital Vane Thermo-Anemometer Model

FG-3000 Digital Force Gauge Operation Manual

NIDEC-SHIMPO INSTRUMENTS

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide Video Borescope Model BR200

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User's Manual. Digital Sound Level Meter. Model

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

User s Manual. Model and Sound Level Calibrators

Dual Moisture Meter Pin / Pinless Moisture Meter

Indoor Air Quality Meter/Datalogger

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

3-Axis G-Force Datalogger

User Manual. Thermocouple Datalogging Thermometer. Model EA15

User's Guide. Model Laser Photo Tachometer

Heavy Duty Datalogging Light Meter

SuperHeat Psychrometer Models RH350 and RH355 (kit)

Video Borescope Inspection Camera

Heavy Duty Differential Pressure Manometer. Model User's Guide

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Series FGE-XY Force Gauges Operation Manual

User Guide. Video Borescope. Models BR200 and BR250

-Direct.com FG-3000 Digital Force Gauge Operation Manual

Model A Current Calibrator. User Guide

Model A Mini AC/DC Clamp Meter. User's Guide

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

Heavy Duty Datalogger Module

User's Guide. Datalogging Hygro-Thermometer Model SD500

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer

User's Guide. EasyView K-Type Thermometer. Model EA11A

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Humidity & Temperature Datalogger

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

Transcription:

User s Manual Models 475055 Digital Force Gauge Additional User Manual Translations available at www.extech.com

Introduction Congratulations on your purchase of Extech s Model 475055 Digital Force Gauge that measures Tension or Compression (pull/push) to 220 lbs. It features: Peak hold, fast/slow response time, positive or reverse display direction, and a separate sensor. An RS-232 PC interface provides data acquisition functionality. This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service. Meter Description 1. Sensor socket 2. LCD display 3. Keypad 4. Kg/N/lb switch 5. Off/On/Peak switch 6. Sensor plug 7. Sensor loop 8. S-type load sensor 9. Sensor hook 10. Mounting holes (60mm apart) 1 2 3 4 5 6 7 8 9 10 2

Operation Preparation for Measurement 1. The 475055 automatically determines Tension or Compression (pull/push) force during use. Compression displays as a negative value and Tension displays as a positive value. 2. Select units of measure (kilograms, pounds, or Newtons) via the units select switch. 3. Screw in the sensor hook and loop on the load sensor and then connect the sensor to the meter via the input jack on top of the meter. 4. Select FAST (0.2 seconds) or SLOW (0.6 seconds) update rate. 5. Zero the display before each measurement via the Zero button. Note: The sensing head with adapter must be in line with the object being measured. Avoid rotating the sensing head. Refer to the Figure 1. Figure 1 Correct and Incorrect Angles of Measurement Acceptable Not Acceptable Measurement Mode 1. Slide the POWER switch to the ON (I)position. Reverse the LCD display if desired via the Display Reverse key. 2. Zero the meter before each measurement. 3. Touch the adapter to the object being measured in a straight line. Refer to Fig.1. 4. Begin measurement by applying force (Push or Pull). Read the LCD display. 5. After completing the measurement, the display will indicate "0.00" if the position and angle of the Force Gauge have not changed. Note: Be sure to press "ZERO" before taking a new measurement. Remove the sensor hook/loop from the S load cell for a PUSH or compression measurement. Over Range Indication The Model 475055 uses a strain gauge sensor to measure force. Avoid subjecting the instrument to forces outside the specified measurement range. The sensitive strain gauge can be damaged or otherwise compromised by misuse. When an over-range condition is sensed by the meter the LCD displays all dashes. Note that the dashes are shown at the top of the LCD ( -------- ) for tension measurements and at the bottom of the display ( -------- ) for compression measurements. 3

Peak Load Measurement 1. Slide the POWER switch to the PEAK position. 2. Touch the adapter to the object being measured in a straight line, refer to Fig. 1. 3. Zero the meter before each measurement. 4. Begin measurement by applying force (pull or push). The LCD will display the peak value, which is the highest reading encountered. 5. After completing the measurement, the display will hold the peak reading until a higher reading is reached or the switch is moved out of the peak hold position. Note: Be sure to press "ZERO" before taking a new measurement. Remove the sensor hook/loop from the S load cell for a PUSH or compression measurement. Fast/Slow selection Press the FAST/SLOW key to select the desired display update rate. The FAST icon will appear in the display when FAST is selected. Mounting For best results, mount the Digital Force Gauge to a test fixture. Mounting holes are provided on the rear of the meter for use with fixtures and test stands. Display Backlight Pressing the backlight button momentarily will turn on the backlight. After approximately 15 seconds, it will automatically shut off. PC Interface PC interface port For streaming of data from the meter to the PC via the RS232 port, the optional 407001-USB cable is required. Contact Extech for the Software protocol for the data stream (Support@Extech.com). Maintenance Battery Replacement The low battery indication appears as a "LO" on the display when battery voltage is less than 6.8V. To replace the battery: 1. Remove the two screws from the battery compartment cover. 2. Lift off the battery cover. 3. Replace with six (6) 1.5V AA batteries. 4. Replace compartment cover and screws. 4

Specifications Range Accuracy (23 o C) Resolution Overload Capacity Circuit Zero adjust Display Update Rate 220 lbs, 100kg, 980 Newtons ±(0.5%rdg + 0.1lbs, 0.1kg or 0.4N) 0.05lbs, 0.05kg, 0.2 Newtons 150kg Custom LSI microprocessor Button for Peak Hold and normal display zero 5-digit LCD type; Digit height: 0.63 (16 mm) Fast mode 0.2 seconds; Slow mode 0.6 seconds Over range Indicators LCD displays -------- for tension measurements and -------- for compression measurements Zero / Tare Control Up to Maximum capacity Full Scale Deflection <1mm Transducer type S-type load cell with 2 hooks (thread size: M6 x 1mm ISO) and 6.5 ft (2m) cable Peak Hold Freezes Max reading on display Data Output RS-232 serial interface with 16-bit data stream output Operating Temperature 0 C to 50 C (32 F to 122 F) Operating RH Max. 80% Relative Humidity (RH) Power Supply 6 x 1.5V AA batteries or 9VDC adapter (not included) Power consumption 28mA (approx.) Weight Meter: 450g (1 lb) Sensor: 380g (0.84 lbs) Dimensions Meter: 215 x 90 x 45 mm (8.5 x 3.5 x 1.8 ) Sensor with 2 hooks: 145 x 51 x 15 mm (5.7 x 2.0 x 0.6 ) Cable length: 2m (6.5 ft.) Test Stand Mounting Holes Located on rear (thread size: M5 x 0.8mm ISO); mounting screws included. Holes are 60mm apart Copyright 2014 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 5