PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

Similar documents
PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates

UndercoverEye Power Box Instruction Manual

BuckEye Cam ORION CellBase

Remote VideoEye Instruction Manual

8-Bit Temperature Smart Sensor (Part # S-TMA-M0XX)

2-Way Wireless I/O Expander Installation Guide

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Hardware Documentation

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Wall. No opening (Example: LA-030-W)

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

INSTALLATION INSTRUCTIONS

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

For use with QED controls panels ONLY

SMART SWITCH. User s Manual. This product is to be used with the MySmartBlinds automation kit.

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

Global Water Instrumentation, Inc.

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

Proliphix EPA-60 Installation Guide

MPP200 User s Manual

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

CA-A480-A Elevator Controller. Reference & Installation Manual

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

Operation and Installation Manual

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Agility 2-Way Wireless Slim Keypad

VIP-812A DUAL NETWORKED STATION PORT

SECURE/NONSECURE LED SIGN USER MANUAL

R52 Top Commander. Installation and Configuration Guide. 325 Sharon Park Dr. #652. Menlo Park, CA USA (650)

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Remote Refrigeration Control

Quick Start Installation Guide V.2.0. Copyright 2012, OmniSite, All Rights Reserved

PWRguard PLUS Spring City Drive Waukesha, WI

Introduction. Contents

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

TRIPLETT CobraCam 2. Portable Inspection Camera & Video Monitor. Instruction Manual /10

Wireless Doorphone Intercom

INSTALLATION INSTRUCTIONS

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

INTELLITAPE USERS MANUAL. Intellitape USERS MANUAL Chief Automotive Technologies, Inc.

Tattletale Micro Tracker

MP3 Speaker USER GUIDE

For use with QED and hardwired control panels ONLY!

QUICK START GUIDE. 1. How to register your Camera to Hubble account A. Setting Up the Camera - can be connected via WiFi or LAN

AirPro Surveyor 2 Manual

NAPCO iseevideo Fixed IP Camera User Guide

SP-C1 Mobile Docking Station Installation Guide

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tank Console Instruction Manual

What s in the Box? Weatherproof Camera transmitter with Antenna Power Cable 3m Sticker. 2 RVS SyStemS

BTH-808 WIRELESS BLUETOOTH HEADSET USER S MANUAL

RV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

User Manual Landscape Irrigation Controller

User Guide. Control Box. RoscoLED TM.

In this document, you will find all you need to know about ACTi Warranty in terms of Duration, Coverage and how to extend the default warranty.

LLTOUCHDX4 - PRODUCT INFORMATION

Digital Contact Tachometer

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Digital Snitch Wireless Camera Interceptor Pro. Model: PEB900. User Guide

MWC-8. Operation MWC-8 800MHz Controller Manual. Operation Manual. manmwc9.

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

INSTRUCTIONS FOR LED INDUSTRIAL LIGHTING LIGHT STRIPS AND WORK LIGHTS

PCM-7140 Pulsed Current Source Operation Manual

Messager USB w/ Night Answer

SpeedVault Model SV 500 User Manual

PSA200 User s Manual

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

HVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

MPP1700 User s Manual

FNet Repeater Installation & Operator s Instruction Manual

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

CR87B TEMPERATURE RECORDER

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Z-Wave Plus Smart Switch Dual Rocker. Installation Guide Ecolink Intelligent Technology Inc. PN DDLS2-ZWAVE5. A Universal Electronics Company

URC Light Sensor SEN-LITE for use with MRX units containing sensor ports

THECHARGEHUB.COM. User Manual. For Square & Round Models

PMDX-105 Quad Isolator Board

zpen-1080p Features zpen-1080p Layout

SATA II HDD Canister KISS DA 435 Quick Reference Guide

OPERATIONS MANUAL PCM-DOC

Model 3526-B Digi-Probe Multimeter

10 Digital Photo Frame Instructional Manual

ARIENSE SENSE YOUR WORLD. 3-Axis Force Sensor FSE103. User Guide. Version 2.1. July VARIENSE INC.

Everything in its place. OWNER S MANUAL. TRINITY 56 ROLLING WORKBENCH STAINLESS STEEL Model # TLS-4804 (Stainless Body) TLS-4805 (Black Body)

iq 16 Sync Charge Box

Introduction. 1. RF Module

DOLXFD1000B. Waterproof Access Control/Reader

MULTIPLEXER MX4. Operation and Installation Manual. Pacific Micro Systems

Installation and Operation Guide

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

Seven Channel Remote Control

Certifications (regional):

AnalogBridge Analog transmission system

Bluetooth USB Adapter TALUS. User Guide

Transcription:

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors Model: SEN-410 User s Manual Version 1.00

WARRANTY REGISTRATION PixController, Inc. warrants products sold by it and guarantees to correct, by repair or replacement at our option, any defects of material and workmanship which develop under normal and proper use within six (6) months from the date of the original purchase when inspection proves the fault to be of manufacturing. Some circuit board components only receive a twelve (12) month warranty. All such Products must be returned to our service center. This warranty does not apply to any of our Products which have been repaired or altered by unauthorized persons or service centers in any way so as, in our judgment, to injure their stability or reliability, or which have been subject to misuse, negligence, or accident or which have had their serial number altered, effaced or removed. We will not assume any expense or liability for repairs made by other parties without our written consent. PixController, Inc is not responsible for damage to any associated equipment or apparatus, nor shall we be held liable for loss of profit or other special damages. There is no other guarantee or warranty except as herein stated. Returns for any unaffected products are permitted within 14 days from the date of receipt of merchandise. After such time, items will incur a 15% restocking fee. Returns of wrong ordered items are allowed. Returned merchandise will be accepted only if all conditions are met. In no event shall PixController, Inc. be liable for any incidental, special, indirect or consequential damages, whether resulting from the use, misuse, or inability to use this product or from defects in this product. The Buyer is not permitted to tamper or remove any of the Raptor System electronics without voiding this warranty. The Buyer, his employees, or others assumes all risks and liabilities for the operation, the use and the misuse of the product described herein and agree to defend and to save the seller harmless from any and all claims arising from any cause whatsoever, including seller s negligence for personal injury incurred in connection with the use of the said product. PixController, Inc reserves the right to discontinue models at any time or change specifications, price or design without notice and without incurring any obligation. The express warranties are in lieu of all other warranties, guarantees, promises, affirmations, or representations, express or implied which would be deemed applicable to the goods sold hereunder. No express warranties and no implied warranties, whether of merchantability, fitness for any particular use or purpose, against infringement, or otherwise (except as to title) other than those expressly set forth herein, shall apply. FOR REPAIR CONTACT PixController, Inc. 1056 Corporate Lane Export, PA 15632 Phone: 724-733-0970 Fax: 724-733-0860 Email: support@pixcontroller.com Web : http://www.pixcontroller.com

Table of Contents 1. Warranty Information 2. Wireless Switch Sensor Overview 3. Wireless Switch Sensor Specs 4. Removing and Replacing the Battery 5. Powering on the Wireless Switch Sensor 6. Programming the Wireless Switch Sensor DIP Switches 6.1 Powering On/Off the Wireless Sensor 6.2 Setting the Wireless Sensor Address 6.3 Setting Range-Test Mode 6.4 Adjusting the Digital PIR Sensitivity 7. Wireless Switch Sensor Mounting Options 8. Connecting Sensors 8.1 Wiring Normally Open Sensors 8.2 Wiring Normally Closed Sensors

2. Wireless Switch Sensor Overview The wireless switch sensor is an advanced detection system which can function with any normally open (NO) or normally closed (NC) contact type sensors. These sensors can include normally closed sensors such as magnetic door sensors or normally open sensors such as pressure pad sensors. Please see www.pixcontroller.com for a complete list of pre-wired sensors compatible with the wireless switch sensor. When the sensor is tripped it will send a wireless digital trigger command to a PixController wireless RF camera system. This includes, but not limited to the UndercoverEye Product line, Raptor Camera Wireless Sensor Version, DigitalEye RF, DVREye RF, Remote VideoEye, and Sony LANC RF Systems. The PixController wireless switch sensor incorporates advanced features such as long range low power digital RF (radio frequency) transmission between the sensor and receiving camera unit. This ensures RF transmission through thick foliage for outdoor applications and walls for indoor applications. The wireless sensor can be setup to transmit four unique digital address codes. The electronics were designed to be extremely battery efficient. Using 3 standard AAA alkaline batteries the sensor can be used in the field up to one year with standard use. The small packaging of the wireless sensor makes it ideal for covert applications. Only the front portion of the sensor needs to be exposed. The sensor housing is made from rugged PVC plastic which is completely weather proof. There is a ¼-20 mounting hole on the bottom of the sensor which can be used with standard bullet camera-type tri pod mounts. Note: Any PixController RF wireless sensor camera system can function with the PixController Wireless Digital PIR Sensor. Products sold before September 15, 2011 will need to have a crystal changed on the RF receiver electronics. These products can be shipped back to PixController, Inc. to have the crystal replaced. Please contact us for more information.

Figure 1: Wireless Switch Sensor Parts 3. Wireless Switch Sensor Specs Size: 6.0 X 1.30 Battery: 3 AAA Battery Life: ~1 Year Current Draw: 107uA (Sleep Mode), 4mA (Transmit Mode) RF Frequency: 315MHz RF Range: ~100 depending on terrain and obstructions Integrated RF Antenna Stainless Steel Sensor Cable Connector 16 Sensor Cable with 3 Sensor Contact Wiring Leads ¼ -20 Screw Mounting Hole 4 Adjustable Digital Sensor Address Settings via DIP Switch Power on/off via DIP Switch LED indicator for testing battery, walk-test, and range-test modes. Rugged PVC Waterproof Housing

4. Removing and Replacing the Battery To remove or replace the battery in the wireless sensor unit simply pull off the rubber battery cover located at the rear of the sensor. A 3 AAA battery holder will slide out. Removing the battery will be necessary to power the unit on/off, change DIP switch programming settings, and replacing the batteries. Figure 2 shows how the battery cover and battery is removed, and Figure 3 shows the DIP switches inside of the sensor tube. Figure 2: Replacing/Removing Battery Figure 3: Digital PIR Sensor DIP Switch & LED

5. Powering on the Wireless Switch Sensor To power the wireless senor on you must first remove the battery cover and battery holder from the sensor tube as shown above. Using a small screw driver such as a jewelers screw driver press on switch 1 on the DIP switches as shown in Figure 4. The switches are rocker type switches and you will need to press switch 1 at the top of the switch. When the sensor is powered on you will notice the LED turn on and blink 5 times. This will let you know that the wireless sensor is going into a 1-minute walk-test mode. If you place your hand in front of the senor the LED will blink giving you feedback that the PIR sensor is functioning. After 1 minute has expired the LED will blink 5 more times and exit walk-test mode. From this point on there will be no LED activity, but the sensor is armed and active. Figure 4: Adjusting DIP Switch Settings

6. Programming the Wireless Switch Sensor DIP Switches The wireless sensor can easily be programmed by adjusting the small switches on the DIP Switch (see Figure 5). The sensor is powered on/off by the DIP Switch, and you can also adjust the wireless sensor address and PIR detection sensitivity. Figure 5: DIP Switch Figure 5a: DIP Switch Functions

6.1 Powering On/Off the Wireless Sensor Switch 1 will power on/off the wireless PIR sensor unit. Putting the switch in the down position will turn the senor off, and putting the sensor in the up position will turn the sensor on. When the sensor is turned on the LED will blink 5 times. The default setting is all switches down (2 7), assuming switch 1 is on for sensor in operation mode. The sensor is shipped with the PIR sensitivity programmed in medium sensitivity mode. 6.2 Setting the Wireless Sensor Address The wireless PIR sensor can be set to send out 4 different address codes (A through D). DIP switches 2 & 3 are used to set the sensor address. Setting the sensor address code is useful when using multiple sensors with multiple camera units. Camera units can be set to respond to certain sensor addresses. Sensor Address Switch 2 Switch 3 ---------------------------------------------------------- Address A Down Down Address B Down Up Address C Up Down Address D Up Up Note: When changing the sensor address you will need to power the sensor off and back on to take effect. 6.3 Setting Range-Test Mode Range-Test mode puts the sensor into a mode where it will send out trigger commands on 2- second intervals. In this mode the PIR sensor is inactive. This mode is used to set the range between the wireless PIR sensor and the receiving unit. To set Range-Test mode start with the wireless sensor in the power down state. Turn DIP switches 2 and 3 into the down off position. Next, power the sensor on by turning switch 1 into up on position. Wait for the LED to blink 5 times. Next, move switches 2 and 3 into the up on position. The wireless sensor is now in Range-Test mode. To take the wireless sensor out of Range-Test mode power the sensor down by turning switch 1 into the off position then turning switch 2 and 3 into the off position..

7. Wireless Switch Sensor Mounting Options There are several mounting options for the wireless sensor. There is a ¼-20 mounting hole on the bottom of the sensor which can be used with bullet camera tri pod mounts. The sensor can also be placed on the ground, but keep in mind that elevating the sensor will increase PIR detection range and range between the wireless sensor and recording electronics. Figure 6: Using Bullet Camera Tri Pod Mounts

8. Connecting Sensors The Wireless Switch Sensors can use an array of sensors such as magnetic door/windows sensors, pressure pad sensors, vibration sensors which are triggered by switch contacts that open or close. The Wireless Switch Sensor includes an interface cable which can be connected to these types of sensors. These sensors can be NO (Normally Open) or NC (Normally Closed) types sensors. The Wireless Switch Sensor will automatically detect which type of sensor is attached by following the proper wiring procedures. Wireless Switch Sensor Cable Ends The end of the Switch Sensor Cable consists of a Brown, Black, and Blue wires to wire to your sensor. The following wiring procedure should be followed for the following sensor types. 8.1 Wiring Normally Open Sensors Normally open sensor such as Pressure Pads or Vibrations sensors are triggered by a switch closure when activated. They are normally open contacts when not triggered. To wire the normally open sensor to the Wireless Switch Sensor Cable Connect: Sensor Contact 1: Sensor Contact 2: Brown and Black Wires Blue Wire 8.2 Wiring Normally Closed Sensors Normally closed sensor such as Magnetic Door/Window sensors are triggered by a switch opening when activated. They are normally closed contacts when not triggered. To wire the normally closed sensor to the Wireless Switch Sensor Cable Connect: Sensor Contact 1: Sensor Contact 2: Brown Wire Black Wire Note: The Blue Wire is not used