XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Similar documents
Broadband Automatic Disconnect Switch. User Manual

RPM1581HVN RPM20161VN RPM2082HVI RPM20162VI (Remote Power Manager) User s Manual

Rack Power Distribution Unit AP7530, AP7540

User s Manual Legend SB425 K

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PS8 - II. Professional Power Sequencer. User s Manual

Zonit μats TM Users Guide μats1-lv Version 1.2

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

SATA II HDD Canister KISS DA 435 Quick Reference Guide

D-Pack 6 Classic ORDERCODE 50315

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

Automated Tuner System Power Distribution Hub

User Manual Back-UPS BE650MC

DataPort 250 USB 2.0 Enclosure User s Guide (800)

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Register your product and get support at. SPP3038A. User manual

Xtreme Value Rack Tower Series (XVRT) User s & Installation Manual

4 Port USB Power Hub. Model: JH-800 USER MANUAL

Operating Instructions

P O W E R S U P P L Y M A N U A L

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

4170 POS System Installation Guide

User s Manual Legend SB500R UPS K

1X2 HDMI Splitter with 3D Support

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

AC4G-D User s Manual

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Start Here. All-in-One Printer. Print Copy Scan

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

User s Guide. POWERVAR Single Phase Power Conditioners

Logitech Alert 700i/750i System Requirements & Support Guide

iconverter 2-Module Power Chassis

User Guide. Control Box. RoscoLED TM.

Quick Start Guide. Dual USB Wall Charger with PD Charging, (x1) USB-A Port and (x1) USB-C Port. Model: U280-W02-A1C1

Owner s Instruction Manual

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

FNet Repeater Installation & Operator s Instruction Manual

Operating Instructions

Breaker Panel Technical Practice NPDRP1114

USB Ranger 110/410 User Guide

USB Ranger 422 User Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

Installation and Operations Manual

The PST-6. Owners Manual 1

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Specifications, Installation, and Operating Instructions

CV-24D. Stereo to SPDIF Converter with Adjustable Audio Delay. User Manual. Made in Taiwan

Innovative Circuit Technology Ltd.

Liebert MicroPOD 230V

DisplayPort Multi-Display Splitter/Expanders. Models: B , B DVI, B HDMI

Owner s Manual Automatic Voltage Switch

Owner s Manual. Desktop Charging Stations. USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC)

MFJ ENTERPRISES, INC.

CS2 DMX Distribution Splitter

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

Tempco Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Westell. Breaker Panel Technical Practice NPDRP1114

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Installation and Operation Back-UPS Pro BR700G-TW

Model 4001A Modular System Bin Operating and Service Manual

Owner s Manual. HDMI Over Cat5 1x2 Extenders. Models: B126-2A1, B126-2A0

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

Kramer Electronics, Ltd.

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Owner s Manual HDMI Matrix Switch

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

Installation and Operation

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

NIMBUS a personal dashboard for your digital life

MFJ ENTERPRISES, INC.

MPF-1, Mains Power Filter User Manual

Powerware 3105 UPS User s manual

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Installation and Operation Back-UPS Pro 900

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

User Guide. USB/Ethernet Charging Cradle. Mobility Electronics, Inc Via Pasar, San Diego, CA 92126, USA

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

PowerRING Qi DUAL WIRELESS CHARGING RECEIVER

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

Manual Version: V1.00. Video Decoder Quick Guide

DataPort 350 & 525 USB 2.0 and FireWire Enclosure User s Guide (800)

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

EPS Power Supply

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Transcription:

XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved.

Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION... 6 PRODUCT DESCRIPTION... 6 Bypass Distribution Description... 6 SYSTEM CONFIGURATION... 8 LED Description... 9 HARDWARE INSTALLATION GUIDE... 10 Installation... 10 Horizontal Installation (1U)... 10 Vertical Installation (0U)... 11 CONNECTING... 12 Initial Connection and Startup Sequence... 12 USER S OPERATIONS... 15 Normal Operation... 16 Bypass Operation... 16 SPECIFICATIONS... 19 SHIPPING LIST... 20 OBTAINING SERVICE... 21 XTREME POWER CONVERSION CORPORATION LIMITED WARRANTY... 22 Xtreme Power Conversion Corporation (Rev 8/29/13) Page 2

Thank you for selecting this bypass distribution module. It is designed to work in conjunction with a UPS to provide you with protection for connected equipment. Please read this manual before installing the XBDM-Series models XBDM-1015LV, XBDM-1020LV, XBDM-1030LV, and XBDM-1020HV as it provides important information that should be followed during installation allowing you to correctly set up your system for the maximum safety and performance. Included is information on customer support and service. If you experience a problem with the XBDM, please contact technical support. WARNING: Incorrect installation, operation, and/or modifications made to the XBDM will void the manufactures warranty. Xtreme Power Conversion is not liable for personnel or equipment damages as a result. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 3

IMPORTANT SAFETY INSTRUCTIONS: (SAVE THESE INSTRUCTIONS) CAUTION! Two sources of power are present in the XBDM: UPS power and Utility power CAUTION! (UPS has Internal Batteries): Risk of electrical shock Hazardous live parts inside the UPS are energized from the battery supply even when the input AC power is disconnected. CAUTION! (No User serviceable Parts): Risk of electrical shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. WARNING! Unit intended for installation in a controlled environment per installation instructions. CAUTION! If flammable substances such as gases or fumes are present, or if the room is airtight, a hazardous situation may exist in which no electrical equipment should be operated. WARNING! It is strongly recommended that the XBDM not be opened as components have very high voltage and touching those components may be fatal. Only a qualified technician or authorized agent may service the unit. The XBDM unit s output receptacles can carry live voltage even when not connected to an input voltage source. The UPS has its own internal energy source. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 4

CAUTION The unit has a dangerous amount of voltage. If either the UPS or BYPASS indicator is on, the unit s outlets may have a dangerous amount of voltage even when not plugged into the wall outlet because the battery from the UPS may continue to supply power. Care should be taken to undertake installation indoors, free from electrically-conductive particles which are under temperature and humidity control, in order to reduce the risk of electric shock. It is best to disconnect the device using the power supply cord. Ensure that the equipment is placed in a position near the outlet where easily accessible. All servicing on this equipment must be carried out by qualified service personnel. The Xtreme Bypass Distribution Module (XBDM) is intended to allow replacement of the UPS connected without having to shut down the equipment connected to the load circuits on the XBDM. Caution should be observed as the XBDM is always supplied with power by either the UPS or UTILITY. Environment Ensure that all environmental concerns and requirements are met according to specifications listed in this document, otherwise the safety of installation personnel cannot be guaranteed, and the unit may malfunction. Ensure that you remember the following when locating the XBDM: Avoid extremes of temperature and humidity. O Operating temperature: 0 C to +50 C (+32 to +122 F) O Operating elevation: 0 to 3000m (0-10,0000 ft) O Relative humidity: 0-90%, non-condensing O Storage temperature: 0-65 C (+32 to +149 F) O Storage elevation: 0 to 15,000m (0 to +50,0000 ft) Provide protection for the equipment from moisture. Space and ventilation requirements must be met. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 5

INTRODUCTION The information provided in this manual covers single phase 15A, 20A, and 30A bypass distribution modules, their basic functions, operating procedures, options available and emergency situations. It also includes information on how to ship, store, handle, and install the equipment. Only detailed requirements of the XBDM units are described herein, and installation must be carried out in accordance with this manual. Refer to the associated UPS manual for UPS operating instructions. Electrical installation must also carefully follow local legislation and regulations. Only qualified personnel should conduct these installations as failure to acknowledge electrical hazards could prove to be fatal. PRODUCT DESCRIPTION Many different kinds of sensitive electrical equipment can be protected by an Uninterruptible Power Supply (UPS) including computers, workstations, process control systems, telecommunications systems, sales terminals, other critical instrumentation, etc. The purpose of the XBDM is to provide an extra level of protection in allowing for the replacement of a UPS without powering down the loads connected. The XBDM can work with most single phase topologies. It will not work with topologies that have a phase shift between input and output (like ferro of UPS with an isolation transformer). Electrical interference exists in many forms, causing problems in AC power, from lightning, power company accidents and radio transmission motors, air conditioners, and vending machines. Protection of sensitive electrical equipment is vital to protect against power outages, low or high voltage conditions, slow voltage fluctuations, frequency variations, differential and common-mode noise, transients, etc. To prevent power line problems from reaching critical systems causing damage to software, hardware, and equipment malfunctions, the UPS maintains constant voltage, isolating critical load output and cleaning the utility AC power. When a UPS fails or needs maintenance, many times it is necessary to turn off the UPS and disconnect it from incoming electrical circuits. With the XBDM installed between the incoming Utility and the UPS, you can replace the UPS and/or Batteries without dropping the load. You simply switch the XBDM from UPS power to Utility power and remove the UPS while the load connected to the XBDM continues to operate temporarily from Utility power. Bypass Distribution Description The Xtreme Bypass Distribution Module (XBDM) is designed to operate with a single-phase UPS up to 30Amps in output capacity. The XBDM allows you to: Replace or upgrade the UPS without losing power to the protected equipment Provide surge protection if the UPS is not present Provide extra surge protection when the UPS is present As shown in fig. 1 block diagram: Xtreme Power Conversion Corporation (Rev 8/29/13) Page 6

Under normal operation, the UTILITY INPUT flows through the XBDM to the UPS and then out to the CONNECTED LOADS. As shown in fig. 2 block diagram: Figure 1 Block Diagram with UPS Under maintenance operation, the UTILITY INPUT flows through the XBDM to the CONNECTED LOADS the UPS is not in the circuit. Figure 2 Block Diagram without UPS Xtreme Power Conversion Corporation (Rev 8/29/13) Page 7

SYSTEM CONFIGURATION The diagrams shown give front, top and rear view of the XBDM Figure 3 XBDM-1015LV Front View Figure 4 XBDM-1015LV Rear View Figure 5 XBDM-1020LV Front View Figure 6 XBDM-1020LV Rear View Figure 7 XBDM-1030LV Front View Figure 8 XBDM-1030LV Rear View Xtreme Power Conversion Corporation (Rev 8/29/13) Page 8

Figure 9 XBDM-1020HV Front View Figure 10 XBDM-1020HV Rear View Figure 11 XBDM-1015LV Top View LED Description The XBDM has three LED s on the front control panel. These LED s allow the user to quickly understand the status of the unit. Red LED = UPS power is available Orange LED = Utility is available for Bypass operation Green LED = Surge Protection is available. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 9

Figure 12 XBDM Front Panel LED s CAUTION: The Orange LED must be illuminated before transferring to BYPASS power. The Red LED must be illuminated before transferring to UPS power. HARDWARE INSTALLATION GUIDE Inspect the XBDM upon receipt. The packaging is recyclable; keep it for reuse or dispose of properly. Installation The XBDM supports horizontal 1U rack mount and vertical rack mount installation. Horizontal Installation (1U) 1. Attach the two (2) XBDM horizontal mounting brackets (included) on each end of the XBDM using four (4) retaining screws (included) see Figure 1. Figure 13 XBDM Horizontal Mounting Xtreme Power Conversion Corporation (Rev 8/29/13) Page 10

2. Install the XBDM in a suitable horizontal location in the rack rail using four (4) user-provided mounting screws. Vertical Installation (0U) 1. Attach the two (2) XBDM horizontal mounting brackets (included) on each end of the XBDM using four (4) retaining screws (included) see Figure 2. Figure 14 XBDM Vertical Mounting 2. Attach the two vertical mounting brackets (included) to the horizontal rack mounting brackets on each end of the XBDM using four (4) retaining screws (included) see Figure 2. 3. Install the XBDM in a suitable vertical location on the side of the rack rail with four (4) user provided mounting screws. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 11

CONNECTING Initial Connection and Startup Sequence 1. If the UPS is already installed and operating, continue to Step 3. 2. Install the UPS and any optional Extended Battery Packs or Modules according to UPS manufacturers documentation. Do not connect loads to the UPS (Proceed to step 5) 3. Prepare your equipment for shutdown. 4. Turn the UPS OFF in accordance with UPS manufacturers documentation. 5. Unplug the UPS. Depending on the model of UPS it may take a few seconds for the UPS to completely shut down. All indicators on the UPS front panel should shutdown. 6. Disconnect the protected equipment power cord(s) from the UPS. 7. Verify that the BYPASS switch on the XBDM is in the UPS position. Figure 15 XBDM Bypass Switch UPS Position Xtreme Power Conversion Corporation (Rev 8/29/13) Page 12

8. Plug the XBDM into a properly wired utility outlet. Figure 16 XBDM to AC Input Receptacle The orange bypass available light should illuminate on the Bypass Distribution Module. 9. Plug the UPS OUTPUT cord from the XBDM into an OUTPUT RECEPTACLE on the UPS. Figure 17 XBDM Cord to UPS Output Receptacle Xtreme Power Conversion Corporation (Rev 8/29/13) Page 13

10. Plug the equipment to be protected into the appropriate XBDM output receptacles. Note: XBDM-1030LV has two LOAD GROUPS. If you have a combination of loads greater than 20A, split the loads by plugging some cords into LOAD GROUP 1 and the others into LOAD GROUP 2. Figure 18 XBDM-1015/1020LV Output Receptacles Figure 19 XBDM-1030LV Output Receptacles Xtreme Power Conversion Corporation (Rev 8/29/13) Page 14

Figure 20 XBDM-1020HV Output Receptacles 11. Plug the UPS INPUT power cord into the UPS INPUT RECEPTACLE on the XBDM. Depending upon the UPS operation, once the XBDM is connected to AC INPUT, the UPS may begin its startup procedure. Figure 21 XBDM UPS Input Receptacle 12. Press the ON BUTTON on the UPS. All indicators on the UPS should operate normally and output power should be provided to LOADs connected to the XBDM OUTPUT. The red UPS available light should illuminate on the Bypass Distribution Module. USER S OPERATIONS The purpose of this is to allow servicing of the UPS so as not to affect the LOADs connected and protected. To transfer between UPS and utility sources, swiftly actuate the Xtreme Power Conversion Corporation (Rev 8/29/13) Page 15

bypass switch to the opposite position. Both the UPS, and Utility lights available must be illuminated to prevent transferring to a non-powered source. Normal Operation When operating in NORMAL mode the switch on the front of the XBDM will be in the UPS position Figure 22 XBDM Bypass Switch UPS CAUTION: The red LED on the bypass module must be illuminated before transferring to the UPS position. Bypass Operation To transfer your equipment to Maintenance Bypass (AC Line operation) and remove the UPS: 1. Toggle the Bypass Switch on the XBDM to UTILITY position. The XBDM is now powering your equipment from Utility power. Figure 23 XBDM Bypass Switch - UTILITY CAUTION: The Orange LED must be illuminated before transferring to BYPASS operation. CAUTION: When the XBDM is operating in UTILITY MODE, the LOAD connected is not protected from power outages. 2. Press the OFF BUTTON on the UPS per the UPS manufacturers documentation. 3. If any optional Extended Battery Packs or Modules are connected to the UPS, turn off the circuit breaker on the battery pack or module (if applicable), and disconnect the cable from the battery pack or module to the UPS. 4. Disconnect the UPS output cord from the XBDM to the UPS output receptacle. 5. Disconnect the UPS INPUT CORD from the UPS INPUT RECEPTACLE on the XBDM. 6. Remove the UPS. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 16

To reinstall the UPS and transfer your equipment from Maintenance Bypass (AC Line operation) to the UPS: 1. If optional Extended Battery Packs or Modules are installed, reconnect the cable from the battery pack or module to the UPS, and turn on the circuit breaker on the battery back or module (if applicable) per the UPS manufacturers documentation. 2. Connect the UPS output cord from the XBDM to a UPS output receptacle 3. Plug the UPS INPUT POWER CORD into the XBDM UPS INPUT RECEPTACLE. 4. Start the UPS per the manufactures instructions. The red UPS available light should illuminate on the Bypass Distribution Module. 5. Toggle the Bypass Switch on the XBDM to UPS position. The XBDM is now powering your equipment from UPS power. Note: XBDM-1030LV has two BYPASS SWITCHES each controlling a separate group of receptacles. Please assure you have operated both BYPASS SWITCHES prior to removing the UPS from the XBDM. A label is placed on the top of each XBDM to highlight the proper connectivity of the INPUT and OUTPUT of the XBDM and UPS. Figure 24 XBDM-1015/1020LV Top Unit Label Xtreme Power Conversion Corporation (Rev 8/29/13) Page 17

Figure 25 XBDM-1030LV Top Unit Label Figure 26 XBDM-1020HV Top Unit Label Xtreme Power Conversion Corporation (Rev 8/29/13) Page 18

SPECIFICATIONS XBDM MODEL XBDM-1015LV XBDM-1020LV XBDM-1030LV XBDM-1020HV* POWER RATING 15A / 120VAC 20A / 120VAC 30 A / 120VAC 20A / 230VAC UTILITY INPUT 5-15P 12FT 5-20P 12FT L5-30P 6FT IEC C20 AC FREQUENCY 50 / 60 HZ MAXIMUM OUTPUT 12A 16A 24A 16A RECEPTACLES FRONT OUTPUT (6) 5-15R (6) 5-20R (5) 5-20R (2) IEC C19 + (4) IEC C13 REAR OUTPUT (4) 5-15R (4) 5-20R (5) 5-20R (4) IEC C13 REAR UPS INPUT (1) 5-15R (1) 5-20R (1)L 5-30R (1)IEC C19 UPS OUTPUT 5-15P 3FT 5-20P 3FT L5-30P 3FT IEC C20 TRANSFER SWITCH BREAK BEFORE MAKE TWO-POLE (MAX 8ms TRANSFER TIME) (1) 15A (1) 20A (2) 20A (1) 20A AC SURGE MAX SPIKE CURRENT 6500A ENERGY DISSIPATION 114 Joules 220 Joules MAX CLAMPING VOLTAGE 330V 775V INDICATORS UPS AVAILABLE UTILITY AVAILABLE SURGE PROTECTION RED LED ORANGE LED GREEN LED PHYSICAL SIZE (1U) (W x D x H) 17 x 3.5 x 1.75 WEIGHT 3.5 LBS *Note: XBDM-1020HV has two different part # s. Please see Shipping List on next page. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 19

SHIPPING LIST 1. (1) XBDM 2. Standard 19 rack mounting hardware 3. User s Manual 4. For XBDM-1020HV: A. FOR USE WITH NXRTi-1000 (XBDM1020HV1): I. (1) IEC C19 to SCHUKO II. (1) IEC C13 to C20 III. (1) IEC C14 to C19 B. FOR USE WITH NXRTi-2000/3000 (XBDM1020HV2): I. (2) IEC C19 to C20 II. (1) IEC C19 to SCHUKO Xtreme Power Conversion Corporation (Rev 8/29/13) Page 20

OBTAINING SERVICE If the XBDM requires Service: 1. Use the TROUBLESHOOTING section in this manual to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme Power Conversion Corp Technical Support at 800.582.4524 or +1.720.292.1217. Technical support inquires can also be made at support@xpcc.com. Please have the following information available BEFORE calling the Technical Support Department: a. Your name and address. b. The serial number of the unit. c. Where and when the unit was purchased. d. All of the model information about your UPS. e. Any information on the failure, including LED s that may or may not be illuminated. f. A description of the protected equipment, including model numbers if possible. A technician will ask you for the above information and, if possible, help solve your problem over the phone. In the event that the unit requires factory service, the technician will issue you a Return Material Authorization number (RMA). If you are returning the XBDM to Xtreme Power for service, please follow these procedures: 1. Pack the XBDM in its original packaging. If the original packaging is no longer available, as the Technical Support Technician about obtaining a replacement set of packaging material. It is important to pack the XBDM properly in order to avoid damage in transit. Never use Styrofoam beads for a packing material. 2. Include a letter with your name, address, daytime phone number, RMA number, a copy of your original sales receipt, and a brief description of the problem. 3. Mark the RMA number on the outside of all packages. Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes. 4. Return the XBDM by insured, prepaid carrier to the address provided by the Technician. Refer to the Warranty statements in this manual for additional details on what is covered. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 21

XTREME POWER CONVERSION CORPORATION LIMITED WARRANTY Xtreme Power Conversion (XPC) Corporation warrants Xtreme Power Conversion equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship (excluding batteries) for a period of three years for XBDM-Series products from the date of purchase. For equipment sites within the United States and Canada, this warranty covers repair or replacement, at the sole discretion of XPC Corporation. The customer is responsible for the costs of shipping the defective product to XPC Corporation. XPC Corporation will pay for ground shipment of the repaired or replacement product. This warranty applies only to the original purchaser. If equipment provided by XPC Corporation is found to be Dead-on-Arrival (DOA), XPC Corporation will be responsible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer, once the customer has requested and received a Return Material Authorization (RMA) number. DOA equipment is defined as equipment that does not properly function according to user documentation when initially received and connected in conjunction with proper procedures as shown in the user documentation or via support provided by XPC Corporation personnel or authorized agents. This warranty shall be void if (a) the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party; (b) the equipment is damaged by the customer, is improperly used or stored, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications; or (c) the equipment has been used or stored in a manner contrary to the equipment s operating manual, intended use or other written instructions. Any technical advice furnished by XPC Corporation or a XPC Corporation authorized representative before or after delivery with regard to the use or application of Xtreme Power Conversion equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances, but it is used at the recipient s sole risk. EXCEPT AS STATED ABOVE, XPC Corporation DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. EXCEPT AS STATED ABOVE, IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT, including but not limited to, any costs, lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost of substitutes, or claims by third parties..purchaser s sole and exclusive remedy for breach of any warranty, expressed or implied, concerning Xtreme Power Conversion equipment, and the only obligation of XPC Corporation under this warranty, shall be the repair or replacement of defective equipment, components, or parts; or, at XPC Corporations sole discretion, refund of the purchase price or substitution of an equivalent replacement product. Xtreme Power Conversion Corporation (Rev 8/29/13) Page 22