Operating Instructions

Similar documents
Four-channel Venetian blind actuator 230 V Installation Instructions

Operating Instructions. DALI-Gateway

1-channel shutter actuator 6A UP Installation Instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Operating Instructions. Power-DALI-Potentiometer

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 Controls:

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Figure 1: Device components

picture 1: Device components

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

Switch/shutter actuator 8/4gang 16A RMD Switch/shutter actuator 16/8gang 16A RMD

Product documentation

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Product documentation

Electrical devices may only be mounted and connected by electrically skilled persons.

Installation Instructions

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

picture 1: Device components

KNX/EIB Product documentation. Issue:

instabus EIB System Actuator

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

The LED display (1) turns green when the load is switched on.

4-gang and 8-gang switch actuator 16A C-load SE

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Blind actuator 4-gang 230 V AC Order-No

Operating instructions only for authorized, skilled electricians with EIB training

Mounting instructions Flush box of Flat Panel PC

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Product and functional description

Product documentation

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Product documentation

Technische Daten: instabus EIB supply instabus line: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product documentation

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

1. Function. Table of Contents

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

The output variables can be force-controlled from a coordinating control system.

6173 AG GJB A0138

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Operating voltage Maximum

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

An optional analog input module, Order no connected to a 6-pole system connector adds four more analog sensors to the device.

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Product and functional description

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Product and functional description

KNX DALI Gateway Plus - User Manual

Product documentation

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

Water-protected surface-mounted push-button bus coupler Order No , , ,

Push Button Interface UP 220D31

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Positioning modules with DC V output signals, and storage of positioning value

Operating and mounting instructions

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Product and functional description

High-performance switching actuators

1 Safety instructions. 2 Device components. Smart Panel. Art.-No.: SP 9 KNX. Operating instructions

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

KNX/EIB Intelligent Installation Systems

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Switching module for AC V and up to three load stages, with manual switching

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

DELTA i-system wall switch single UP 221/2 5WG AB_2

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

Impulse switching module

Bus coupler 3 Bus coupler 3 external sensor Order No

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

EAE KNX Room Control Unit Product Manual RCUXXYY

Product documentation. KNX Blind Act.FM w.3 Inputs Art.-No. MTN

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

Transcription:

Operating Instructions 1. System information This unit is a product of the instabus-eib-system and corresponds to the EIBA Guidelines. Detailed technical knowledge acquired in instabus training courses is a prerequisite for the understanding of the system. The functions of the device are software-dependent. Detailed information on the software and the functions implemented and the software itself are available from the manufacturer s product data bank. Planning, installation and commissionning of the device are effected with the help of EIBA-certified software. For the productdatabase and technical descriptions please refer to the internet at www.jung.de offering up-to-date information. 2. Safety warnings Attention: Electrical equipment must be installed and fitted only by qualified electricians and in observance of the applicable accident prevention regulations. To prevent electric shocks, disconnect the power supply before working on the device (by cutting out the circuit breaker). Any non-observance of the fitting instructions may cause fire or other hazards. Shutter actuator applications: Connect only shutter motors to the device. Appropriate safety measures must be taken to exclude any hazards deriving from motor-operated components. Stand: Jun-08 825 238 13

3. Function Depending on parameterization, the actuator can either be used as switching actuator (max. 16 channels) or as shutter actuator (max. 8 channels). Functions can also be mixed, e.g. outputs A1 A6 as switching actuator with 6 channels, outputs A7 A16 as shutter actuator with 5 channels. In the shutter actuator mode, two outputs must be combined for each motor. The device needs an additional power supply. By means of the control and display elements, the actuator if parameterized accordingly - can also be readily operated by hand without bus voltage. This includes also the possibility of central shutoff by hand. Cf. also the chapter on manual operation. 4. Important Switching operation: The relay outputs of an actuator switch with a slight time delay when controlled by a central telegram. Do not connect tri-phase AC motors. The connection of 230 V and SELV voltages to different outputs of an actuator is not permitted. Shutter operation: For shutter operation, 2 neighbouring relay outputs are used as one shutter output. The left (1, 3, 5, ) relay outputs are reserved for the UP movements and the right ones (2, 4, 6, ) for the the DOWN movements. If motors are to be connected in parallel, it is absolutely necessary to observe the instructions of the motor manufacturers. The motors can otherwise be irreparably damaged. Use only shutters with limit switches (mechanical or electronic). The limit switches of the motors connected must be checked for proper adjustment. Activation of the manual operation mode terminates all time delays and the safety shutdown function in stormy weather. The safety shutdown during stroms is reactivated when the manual operation mode is ended. The manual mode permits only continuous movements (long press) and stop (short press). 2

5. Characteristics Shutter operation: Switch-over time during change of movement direction adjustable (observe the instructions of the motor manufacturer) movement directions lockable by software control Sun protection function Safety shutdown during storms separately adjustable for each shutter output Response on bus voltage failure and return adjustable For further characteristics, please read the corresponding EIB product documentation. 6. Connection Figure A The bus line is connected to the bus connecting terminal (1). The supply voltage and the loads are connected as per fig. A. The illustration shows the connection of 3 lamps to outputs A 1 A3 and of 2 motors to outputs A5/A6 and A7/A8 as an example. Further loads are connected in the same way. Please observe that the connected loads must be compatible with the parameterization of the outputs. The device can be connected to different phase conductors. Further elements: (2): manual controls and status indicators (3): LED A1 A16 indicate the switching state and the output selected during manual operation. 3

7. Cap Figure B Figure C Slide the cap over the bus terminal with the bus line at the bottom (fig. B) until it is heard to engage. Remove the cap by pressing against the sides and by pulling it out at the same time (fig. C). The cap can be supplied as an extra part (Art. no. 2050 K). 8. Manual operation Figure D Controls and indicators see fig. D Permanent change to manual operation: depress the for about 5 seconds until the respective LED lights up. The actuator is now permanently in the manual operation mode. Control via the EIB is disabled. A short press on the key selects the outputs to be switched. If only one LED flashes, the output is parametrized for switching. 4

2 flashing LEDs indicate the shutter function. Keys 1/ and 0/ can be used for switching the output indicated by a flashing LED A1 A16, the switching state itself being indicated by the LED beside the keys. The switching state of the non selected outputs is indicated, as for bus operation, by LEDs A1 A16. To quit the manual mode: depress the key for about 5 seconds until the respective LED goes out. Temporary change to manual operation: Depress the key briefly until LED A1 or LED A1 and A2 are flashing. The switching state is indicated by LED 1/ and 0/. LED remains off. The actuator is now in the manual mode and the control via the EIB is disabled. If no key is depressed for more than 5 seconds, the actuator quits the manual mode and goes automatically back to bus operation. Keys 1/ and 0/ can be used for switching the output indicated by LEDs A1 A16. The switching state itself is indicated by the LED beside the keys. A short press of the key selects the other outputs which are to be switched or whose status is to be indicated. When all outputs A1 A16 have been selected once, the actuator automatically quits the manual mode. Central shut-off function: In the permanent manual operation, the actuator has a central shut-off function. To activate the central shut-off function, depress the OFF key briefly. All relays (switching and shutter functions) are deactivated. Important: Central shutoff is not available for temporary manual operation. 9. Technische Daten instabus EIB supply : 21-32 V DC instabus EIB power consumption : max. 150 mw Mains supply : AC 110V (-10%) 240V (+10%) 50/60 Hz Total power loss : max. 5,5 W instabus EIB connection : instabus terminal Mains connection : screw-type terminals 0.5 4 mm² single-wire and stranded wire without ferrule or 0.5 2.5 mm² stranded wire with ferrule Ambient temperature : -5 C +45 C Storage temperature : -25 C +70 C Installation width : 144 mm (8 pitch units) Outputs Type of contact : potential-free n.o. contact (μ contact) Switched voltage : AC 250 V Switched current AC 250 V : 10 A 5

Switching capacity Outputs 1-8 Outputs 9 16 ohmic load: 3600 W 3600 W incandescent lamps 1400 W 2300 W HV halogen lamps: 1225 W 2300 W LV halogen lamps: conv. transformers 1200 VA 1200 VA Tronic transformers 1200 W 1200 W fluorescent lamps compensated not approved 920 VA, 80 μf motors (no 3-phase AC motors) 600 W 600 W Technical specifications subject to change 10. Guarantee Our products are under guarantee within the scope of the statutory provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55. 80 65 51 Telefax: +49 (0) 23 55. 80 61 89 E-Mail: mail.vki@jung.de General equipment Service-Line: +49 (0) 23 55. 80 65 55 Telefax: +49 (0) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de KNX/EIB equipment Service-Line: +49 (0) 23 55. 80 65 56 Telefax: +49 (0) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de The -Sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. 6