EE870 Modular CO 2 Transmitter

Similar documents
USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

EE160 - Humidity and Temperature Transmitter for HVAC Applications

EE671 - Miniature Air Flow Transmitter

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Manual EE371. Dew Point Transmitter / Switch down to -60 C Td. BA_EE371_e // V2.0 // technical data are subject to change

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

Manual EE355. Dew Point Transmitter down to -60 C Td. BA_EE355_e // V1.3 // technical data are subject to change

Operation manual EE310. Humidity/Temperature Transmitter. BA_EE310_e // V2.1 // Technical data subject to change //

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

EE75 Series. Manual. Hardware and Software. Air / Gas Velocity Transmitter. BA_EE75_e_12// technical data subject to change //

RS485 MODBUS Module 8AO

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

PICS EE160D & EE210D BACnet Protocol Implementation Conformance Statement

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

OPERATING MANUAL. Series EE240. Wireless Sensor for Humidity Temperature CO 2. BA_EE240_e // V8.0 // technical data are subject to change //

Series EE35 MANUAL. Hardware and Software INDUSTRIAL TRANSMITTER FOR DEWPOINT MEASUREMENT

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

TPM 80. Dew Point Transmitter. Manual. BA_TPM80_e // V1.0 // technical data are subject to change

EE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications

RS 485 Mini Modbus 1AO

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

EXD-TEVI Economizer Controller for Tandem Compressors

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

RXTH DUAL ROOM SENSOR / SWITCH

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

PICS_EE800D // v1.2 / Technical data subject to change. PICS EE800D BACnet Protocol Implementation Conformance Statement

BNI IOL K023 BNI IOL K023. User s Guide

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Carbon Monoxide Sensor - ModBus

RS485 MODBUS Module 8I8O

Application Note. I²C Interface for Digital CO2 Measurement Module

RS485 MODBUS Module 16I-M

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

PICS_EE10D // v1.0 / Technical data subject to change. PICS EE10D BACnet Protocol Implementation Conformance Statement

Application Note. E2 Interface for EE871, EE892 and EE893

RS-FX-N01 wind transmitter user's Guide (485type)

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

RS-FS-N01 Wind speed transmitter user's Guide (485type)

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

OPERATING MANUAL. Series EE240. Wireless Sensor for Humidity Temperature CO 2. BA_EE240_e // V7.0 // technical data are subject to change //

PICS EE850D & EE820 BACnet Protocol Implementation Conformance Statement

BNI IOL K023 BNI IOL K023. User s Guide

EE210. Humidity and Temperature Transmitter for Demanding Climate Control Applications. Features. Applications

RXTP ROOM TEMPERATURE

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

BNI IOL K023 BNI IOL K023. User s Guide

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

EZ-LIGHT K50 Modbus Series Pick-to-Light Sensors

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

RS485 MODBUS Module 8I8RO

USB-BASED 8-CHANNEL DATA ACQUISITION MODULE

MODBUS MESSAGE PROTOCOL FOR MODEL FT2 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

RS485 MODBUS Module 6RO

Air Quality Sensor KNX AQS

BNI IOL-104-S01-Z012-C02

MODBUS Message Protocol MODEL FT3

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

GMM220 CO 2. Transmitter Modules. Introduction. Mounting

USB-Based 14-Channel Data-Acquisition Module

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

RТTH DUAL ROOM SWITCH

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

Digital Indicator DS 48/24 E

BTL6-A_10-M -A1-S115. Data Sheet. english

Warranty. Warning. Copyright. Contact Us

Instruction and Operation Manual

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

RoHS. CO 2, Temperature & Humidity Transmitter Applications

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

INTMOD485-LH Protocol Converter

Product Specification. CO 2 Engine K30 STA. Sensor Module and OEM Platform

BACnet Protocol Converter Kit for Use with Bacharach MultiZone Gas Monitors. Installation Manual

HD B. [ GB ] Precision Barometer

GSV-1A4 M12/2 M12/2. Highlights

Technical data. General specifications. Indicators/operating means

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

an ISO9001/14001 company

OPERATION MANUAL MODEL TT-LP

Transcription:

EE870 Modular CO 2 Transmitter Manual BA_EE870_e // v1.5 // Technische Änderungen vorbehalten

E+E Elektronik Ges.m.b.H. doesn't accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products. The document may contain technical inaccuracies and typographical errors. The content will be revised on a regular basis. These changes will be implemented in later versions. The described products can be improved and changed at any time without prior notice. Copyright E+E Elektronik Ges.m.b.H. All rights reserved. 2

Table of contents GENERAL... 3 IMPORTANT NOTES... 4 CONNECTIONS / MOUNTING... 4 TECHNICAL DATA... 5 DIMENSIONS... 5 HARDWARE SETTINGS... 5 MODBUS MAP... 6 OPERATION OUTDOORS... 7 ACCESSORIES... 7 SCOPE OF SUPPLY... 7 GENERAL For technical data, options and accessories please see EE870 data sheet and operation manual at www.epluse.com/ee870. The modular CO 2 transmitter EE870 consists of following components: EE871 interchangeable CO 2 probe with E2 digital output. For technical data please see EE871 data sheet and operation manual (www.epluse.com/ee871) For readjustment of EE871 please see data sheet and operation manual EE-PCS Product Configuration Software (www.epluse.com/ee-pcs) HA011014 converter board: The converter board supplies the EE871 CO 2 probe and converts its digital output signal into analogue outputs and Modbus RTU digital interface. The measured data is available simultaneously on the analogue outputs and on the Modbus interface. Technical data, setup and operations instructions for HA011014 are detailed in this document. Connecting cable between EE871 CO 2 probe and HA011014. EE870 scope of supply includes one of the following cables, as ordered: HA010809... 1 m length HA010810... 2 m length HA010811... 5 m length HA010812... 10 m length. 3

IMPORTANT NOTES Connecting the supply voltage to the modbus terminals may destroy the device. The HA011014 converter board is supplied as a component and must be installed in accordance with the valid ESD guidelines and properly protected against enviromental influences. Probe Sensing head Filter cap CO 2 Sensing cell The device shall not be exposed to extreme mechanical stress. The sensing head of the probe and mostly the sensing cell might not be exposed to any mechanical stress. The probe must be operated with the filter cap on at all times. Do not touch the sensing cell or electronics inside the sensing head. A long response time indicates a dirty filter cap, as it might happen in polluted applications. Do not attempt to clean the filter cap; it would only cause its clogging. Replace the filter cap by an E+E original one, order no. HA010116. While replacing the filter cap take utmost care to not touch the sensing cell and the electronics. This device is not appropriate for safety, emergency stop or other critical applications where device malfunction or failure could cause injury to human beings. CONNECTIONS / MOUNTING Modbus Dip-switch Jumper "Bus termination resistor" Modbus terminals Terminals for cable EE871 +5V white SCL black SDA blue GND brown Shield grey Jumper "Fast/Slow" Supply terminal* LED: On Fast flash = OK = Error Jumper "Output Range" Analogue outputs* * Very important: for failure-free operation and performance according to the specs the supply GND and the measurement GND must be wired separately. 4

TECHNICAL DATA Digital CO 2 Probe EE871 Measuring principle Dual wavelength (non-dispersive infrared technology) NDIR Measurement range / 0...2000 ppm: < ± (50 ppm + 2 % from the measured value) Accuracy at 25 C and 0...5000 ppm: < ± (50 ppm + 3 % from the measured value) 1013 mbar 1) (77 F...14,69 psi) 0...10,000 ppm: < ± (100 ppm + 5 % from the measured value) 0...3 %: 0...5 %: < ± (1,5 % from full scale + 2 % from the measured value) Response time t 63 105 s with measured data averaging (smooth output) 60 s without measured data averaging Temperature dependency 0...2000 ppm: (-20...45 C) (-4...113 F) 0...5000 ppm: typ. ± (1 + CO 2 concentration [ppm] / 1000) ppm/ C 0...10,000 ppm: 0...3 %: 0...5 %: typ. -0,3 % from the measured value/ C Housing / Protection class Plastic PC / Housing IP65 Cable length max. 10 m (32 ft) Electromagnetic compatibility EN61326-1 (Industrial enviroment) EN61326-2-3 Conversion Board Supply voltage 10-35 V DC / 10-28.8 V AC Supply current 120 ma at 24 V DC / 300 ma at 10 V DC Protection class IP00 Electrical connection screw terminal size: 2.5 mm 2 Analog outputs 0-1 V; 0-5 V; 0-10 V -1 ma < I L < 1 ma selectable by jumpers 0-20 ma; 4-20 ma R L < 500 Ohm Resolution 12 bit Response time t 90 60 s or 105 s selectable by jumpers Modbus RTU setup with dip-switches (see operation manual) Temperature dependence Voltage: typ. ±0.2 mv/ C (0 1V) typ. ±0.5 mv/ C (0 5V) typ: ±0.6 mv/ C (0 10V) Current: typ. ±1 μa / C EE870 Operating conditions -40...60 C (-40...140 F) 0...100 % RH (not condensating) 85...110 kpa (12.33...15.95 psi) EE870 Storage condition -40...60 C (-40...140 F) 0...100 % RH (not condensating) 70...110 kpa (10.15...15.95 psi) 1) For averaging output DIMENSIONS Digital CO 2 Probe EE871 Conversion Board 96 (3.78 ) 6 (0.24 ) 66 (2.6 ) 6 (0.24 ) 4.5 (0,18 ) 3.2 (1.13 ) 39 (1.54 ) 4.5 (0,18 ) 13.8 (0.55 ) 25.8 (1.02 ) 18.5 (0.73 ) M12x1 Weight: Gewicht: 3030g g (1.06 oz) 78 (3.08 ) 5

HARDWARE SETTINGS Analogue-Output Jumper for setting the analogue output: Current Voltage - 0-1 V 0-20 ma 0-5 V 4-20 ma 0-10 V Jumper for setting the response time: fast response time slow response time Example: Jumper "Output Range" set to 0...10 V. Jumper "Fast/Slow" set to "Fast" Modbus-Interface Dip-switch for Modbus settings S1, S2 baud rate S3 stopbit S4 parity S5 - S10 addresse of the converter Jumper for termination resistor active/inactive Example: Dip-switch S1 and S2 "Baud rate" set on 19200 Dip-switch S3 "Stopbit" set on "one" Dip-switch S4 "Parity" set on "even" Dip-switch S5 - S10 "Address" set on "13" (activate S5/S7/S8) Jumper "Termination resistor" set on "No" MODBUS MAP Register address Parameter name Protocol address 0x00 0 0x01 1 0x02 2 0x03 3 Serial number 0x04 4 0x05 5 0x06 6 0x07 7 0x08 FW Version 8 0x09 9 0x0A 10 0x0B 11 0x0C 12 Type number 0x0D 13 0x0E 14 0x0F 15 0x10 16 0x11 17 0x12 18 0x13 19 0x14 20 Serial number 0x15 21 0x16 22 0x17 23 0x18 24 ASCII HIGH BYTE - main version LOW BYTE - sub version ASCII 6 Register address Parameter name Protocol address 0x19 25-0x1A 26 0x1B 27-0x1C 28 0x1D 29 CO 2 fast 0x1E 30 0x1F 31 CO 2 slow 0x20 32 0x21 33 Gain Voltage 0x22 34 0x23 35 Offset Voltage 0x24 36 0x25 37 Gain Current 0x26 38 0x27 39 Offset Current 0x28 40 0x29 41 Measuring range 0x2A 42 0x2B 43 Measuring range 0x2C 44 0x2D Analogue Output 45 0x2E low (V) 46 0x2F Analogue Output 47 0x30 high (V) 48 0x31 49 Slow or Fast 0x32 50 FLOAT ASCII

OPERATION OUTDOORS For outdoor applications, the probe of EE870 must be used with the radiation shield order no. HA010507, which protects the device against rain, snow, ice, and solar radiation. The convertor board must protected IP65 (NEMA4) or better. Ø105 20 Ø5 174 44 94 W 122 ACCESSORIES Replacement probe EE871-HRxJ2 Cable M12 - flying leads (1 m (39.37") / 2 m (78.74") / 5 m (196.85") / 10 m (393.70")) Mounting flange for probe Radiation shield PFTE Filter cap H 2 O 2 filter cap Protection cap for the M12 cable socket Protection cap for the M12 probe plug see data sheet EE871 HA010809/10/11/12 HA010212 HA010507 HA010116 HA010122 HA010781 HA010782 SCOPE OF SUPPLY - EE871 probe according to ordering guide - Test report according to DIN EN10204-2.2 for EE871 - Conversion board HA011014 - Connecting cable HA0108xx - Operation manual - Test report according to DIN EN10204-2.2 for conversion board 7

E+E ELEKTRONIK HEADQUARTERS E+E ELEKTRONIK Ges.m.b.H. Langwiesen 7, A-4209 Engerwitzdorf Austria Tel: +43 7235 605-0 Fax: +43 7235 605-8 info@epluse.at / www.epluse.com E+E ELEKTRONIK SUBSIDIARIES E+E ELEKTRONIK China / Beijing Tel: +86 10 8499 2361 info@epluse.cn / www.epluse.cn E+E ELEKTRONIK China / Shanghai Tel: +86 21 6117 6129 info@epluse.cn / www.epluse.cn E+E ELEKTRONIK Germany Tel: +49 6172 13881-0 info@epluse.de / www.epluse.de E+E ELEKTRONIK France Tél: +33 4 7472 3582 info@epluse.fr / www.epluse.fr E+E ELEKTRONIK Italy Tel: +39 02 2707 8636 info@epluse.it / www.epluse.it E+E ELEKTRONIK Korea Tel: +82 31 732 6050 info@epluse.co.kr / www.epluse.co.kr E+E ELEKTRONIK USA Tel: +1 847 490 0520 office@epluse.com / www.epluse.com YOUR PARTNER IN SENSOR TECHNOLOGY Ges.m.b.H. R www.epluse.com