GE Fanuc IC695CMM004. Rx3i PacSystem

Similar documents
PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

Chapter 1. Introduction. Additional Documentation

GE Fanuc Automation Programmable Control Products. PACSystems RX3i. Serial Communications Modules. User s Manual, GFK-2460A.

PACSystems* RX3i IC695CMM002-EJ and IC695CMM002CA-EJ IC695CMM004-EJ, IC695CMM004CA-EJ, and IC695CMM004LT-EJ Serial Communications Modules

VersaMax* Serial Communications Module

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

PACSystems* RX3i IC694ALG233

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

PACSystems* RX3i IC694ALG232

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

Shown with terminal block Supports diagnostic point fault contacts in the logic program

PACSystems* RX3i IC695PBM300

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

PACSystems* RX3i CANopen Master Module, IC695CNM001 Quick Start Guide, GFK-2837 March 2013

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems RX3i IC695HSC304 and IC695HSC308

Analog Input, 16-Bit Thermocouple Module

GE Fanuc IC695ALG708. Rx3i PacSystem

VersaMax* Analog Input, 16-Bit Thermocouple Module

PACSystems RX7i IC698CMX016-ED

GE Fanuc IC694ALG221. Rx3i PacSystem

PACSystems* RX3i Central Processing Unit IC695CPE302 Quick Start Guide GFK-3038 February 2018

1. FEATURES AND BENEFITS

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

GFK-2372L September 2015


PACSystems* RX3i IC695PSA040

PACSystems* RX3i IC695PSA140

PACSystems* RX3i IC695HSC304-DA and IC695HSC308-DA

General Specifications. P2-SCM Serial Communications

PACSystems RX3i IC695CPU310. Features. Ordering Information. Central Processing Unit. GFK-2329T December 18, 2007

T1K MODBUS Base Controller Specifications

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

P3-SCM. General Specifications

GE Intelligent Platforms

GE Fanuc IC694ALG391. Rx3i PacSystem

A PACSystems RX3i Ethernet NIU I/O Station

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Non-Isolated Analog Output Module with HART Communications, IC695ALG728-DC Non-Isolated Analog Output Modules, IC695ALG704-DC, IC695ALG708-DC

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

ISOLATED RS-232 TO RS-422/485 CONVERTER

GE Fanuc IC695ETM001. Rx3i PacSystem

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide

VersaMax* DeviceNet Network Master/Slave

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Instructions to printer DO NOT PRINT THIS PAGE

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

MGate 5105-MB-EIP Quick Installation Guide

MGate 4101-MB-PBS Series

Checklist for Setting up QuickPanel View MODBUS Connection to a MODBUS Capable GE Fanuc Device with Native Drivers

Important Product Information

Title: Using the AUX Port.

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

VersaMax* IC200PNS001, IC200PNS002

OnCell G3100 Series Quick Installation Guide

MGate 5111 Quick Installation Guide

RemoteTRAK RS485 Distributed I/O for Modbus and Sixnet Systems

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

How to set-up and read MOBBUS

CONTROL MICROSYSTEMS. TeleSAFE Micro16 Controller. Hardware Manual

PACSystems RX3i IC695NIU001

VersaMax Micro and Nano Technical Product Presentation

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

CPU Module IC200CPU005

Forcom Technology Co., Ltd. Intelligent RS-485/422 to RS-232 converter

Black Box Tech Support: FREE! Live. 24/7.

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

PACSystems RX7i IC698CHS009/119

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

CONTROL MICROSYSTEMS Input/Output (I/O) Module. Hardware Manual

Communications Quick-Start Guide

IC695ALG608, IC695ALG616

PCI Express 4-Port Industrial Serial I/O Cards

Title: Using the AUX Port.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

GE Fanuc IC695NKT001. Rx3i PacSystem

-C5RS-LC RS232 EXTENDER

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Troubleshooting Serial Communication to Series 90 & VersaMax PLC s from Proficy Machine Edition

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

RTU560 Remote Terminal Unit Connections and Settings

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

PACSystems RX3i IC695PSA140

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Product Information. Firmware Version 3.00 Programmer Compatibility Expansion I/O Compatibility

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Transcription:

GE Fanuc IC695CMM004 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695cmm004 Rx3i PacSystem RX3i serial communications module. Four isolated RS-232/485 port. IC695C IC695CM IC695CMM 919-535-3180 sales@pdfsupply.com

August 2007 PACSystems RX3i IC695CMM002 and IC695CMM004 Serial Communications Modules PACSystems RX3i Serial Communications modules expand the serial communications capabilities of the RX3i system. Serial Communications module IC695CMM002 provides two independent, isolated serial ports. Serial Communications module IC695CMM004, illustrated at right, provides four independent, isolated serial ports. Up to six Serial Communications modules can be located in the main PACSystems RX3i backplane. Each port can be configured for MODBUS Master, MODBUS Slave, or Serial I/O protocol. In addition, for modules that are version 1.10 or later, each port can be configured for CCM Slave protocol using Proficy Machine Edition 5.6, SIM 6 or later. For modules that are version 1.20 or later, each port can be configured for DNP3 Master or DNP3 Slave protocol using Machine Edition 5.6 SIM 10 or later. If any port is configured for DNP3 Master or Slave, the other ports on the module can only be configured for DNP3 Master or Slave. P1 P2: P3: P4: MODULE OK PORT FAULT PORT 1 PORT 2 Additional module features include: Port-to-port isolation and port-to-backplane isolation RS-232, RS-485/422 communication, software-selected Hardware handshake: RTS/CTS for RS-232 Selectable Baud Rates: 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K Module fault status reporting (Watchdog, Ram Fail, Flash Fail) Module identity and status reporting, including LED status indicators Meets CE, UL/CUL 508 and 1604, and ATEX requirements Flash memory for future upgrades PORT 3 PORT 4 IC695CMM004 These modules must be located in an RX3i Universal Backplane. RX3i Serial Communications can be hot-inserted and removed following the instructions in the PACSystems RX3i System Manual, GFK-2314.

2 RX3i Serial Communications Modules Release Information This release is an upgrade of previous version 1.10. Release History Release Upgrade Kit Comments IC695CMM002-AA IC695CMM004-AA IC695CMM002-AB IC695CMM004-AB IC695CMM002-AC IC695CMM004-AC N/A 44A753277-G02 44A753278-G02 44A753277-G03 44A753278-G03 Initial Release Supports CCM Slave Protocol Supports DNP3 Master and DNP3 Slave Protocol New for this Release This release of the RX3i Serial Module adds support for Distributed Network Protocol 3.0 Master and Slave to the other protocols: MODBUS Master/Slave, CCM, and Serial I/O. This module does not operate with COMMREQs but rather uses preconfigured mappings of the I/O reference memory. MODBUS Master and MODBUS Slave Protocols now support the configuration of 1 stop bit, for compatibility with some GE Fanuc Automation MODBUS Slaves. Compatibility Programmer: Proficy Machine Edition Logic Developer 5.6 with Service Pack 2 SIM 10 RX3i CPU: PACSystems RX3i CPU Version 5.00 or later is required to be able to use the time synchronization feature on a DNP3 Master port. Problems Resolved for This Release When parity is set to none in the port configuration for the Modbus Master or Modbus Slave protocols, the stop bits were forced to 2. This restriction has now been removed and the stop bits can be set to 1 or 2.

RX3i Serial Communications Modules 3 Restrictions and Open Issues in this Release 1. When multiple group objects (i.e. %I and %AI memory) are read in a single request, the DNP3 port will ignore all but the first object. Operations of multiple group objects should be split into multiple successive exchanges (i.e. exchange 1 - %I, exchange 2 - %AI). 2. The DNP3 slave port has problems using the link layer to validate frame receipt. The DNP3 organization encourages users not to do this. 3. These modules do not support GE Fanuc special MODBUS commands for use with a Daniels Flow Computer. 4. PLC Reference Address and Reference Length Parameters do not support bit length/start. Bit and Non- Byte Length operations must begin on a byte boundary. 5. When a port is configured for CCM Slave protocol, and: a new configuration is stored to the PLC using Machine Edition, or the system is power-cycled, or the module is hot-inserted, if the first query received from the CCM Master is a Read Scratchpad request, the module will reject that request. All subsequent Read Scratchpad requests will be successful unless one of the above conditions occurs again. Operating Notes The maximum resolution for the MODBUS drop delay is 420us, so the minimum time for a drop delay is 420us. Installation in Hazardous Locations EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2; WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.

4 RX3i Serial Communications Modules Specifications: IC695CMM002 and IC695CMM004 Refer to the PACSystems RX3i System Manual, GFK-2314, for product standards and general specifications. Number of Serial Ports IC695CMM002: two independent serial ports IC695CMM004: four independent serial ports Connectors RJ-45 Number of Serial Six in the main CPU backplane Communications Modules per CPU Backplane power requirements IC695CMM002 0.7 Amps maximum @ 3.3 VDC 0.115 Amps maximum @ 5.0 VDC IC695CMM004 0.7 Amps maximum @ 3.3 VDC 0.150 Amps maximum @ 5.0 VDC LEDs Module OK, Port Fault, Port Status (2 or 4) Port Type RS-232 or RS-485/22. 4-wire (full duplex) or 2-wire (half-duplex) operation for RS-485/422 Flow Control for R-232 Selectable: Hardware (CTS/RTS) or none Baud rates 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2k Parity Data bits 7, 8 Stop bits 1, 2 Even, odd, none Operating Temperature 0 C to + 60 C Input Impedance Max Overvoltage Channel-Channel Crosstalk Isolation Zin > 96 kohm for RS-485/422 3 kohm < Zin < 7 kohm for RS-232 +/- 25V 55dB minimum Port to Backplane and to frame ground: 250 VAC continuous; 1500 VAC for 1 minute, 2550VDC for one second. Port to port: 500VDC continuous, 710VDC for one minute. In order to meet emission and immunity requirements for the EMC directive (CE mark), shielded cable must be used with this module.

RX3i Serial Communications Modules 5 LEDs P1 P2: P3: P4: MODULE OK PORT FAULT PORT 1 PORT 2 PORT 3 PORT 4 The Module OK LED indicates the status of the module. Solid green indicates that the module has been configured. The Module OK LED is off, if the module is not receiving power from the R3i backplane, or if a serious module fault exists. At powerup, the Module OK LED flashes green/off while the module is executing powerup diagnostics. It then flashes more slowly as the module receives its configuration from the CPU. If a problem occurs, the Module OK LED flashes amber, The blink code (see below) indicates the cause of the error. 1 = watchdog expired 2 = RAM error 6 = Invalid CPU Master Interface version 7 = CPU heartbeat failure 8 = Failed to get semaphore The Port Fault LED indicates the status of all ports. The Port Fault LED is green when there are no faults present on any enabled port. If this LED turns amber, there is a fault on at least one port. A port s Status LED flashes green when there is activity on the port. IC695CMM004 The area below the module LEDs can be used to record identifying information about each port. Serial Ports Each port is a standard RJ-45 female connector with the following pin assignments. For MODBUS applications, note that these pin assignments are different than the standard MODBUS pin assignments. If the port is configured for MODBUS master or slave operation, custom cables are needed. 8 1 RJ-45 Pin RS- 232 RS-485/422 Half Duplex RS-485/422 Full Duplex 8 COM GND GND 7 Termination 2 6 CTS R- (RxD0) 5 COM GND GND 4 Termination 1 3 RxD R+ (RxD1) 2 TxD T- / R- (D0) T- (TxD0 1 RTS T+ / R+ (D1) T+ (TxD1) Note: There is no shield or frame ground pin on the port connector.

6 RX3i Serial Communications Modules If the Serial Communications module is communicating with a Series 90-30 CPU363 or external PACSystems RX3i CPU, the connections are: RX3i Serial Module CPU363/RX3i T+ To RD('B') T- To RD('A') R+ To SD('B') R- To SD('A') Termination By default, each port is set for no termination. Termination is needed if the module is the first or last device on an RS-485 network, even if there is only one other device on the network. Termination can be provided using either an external resistor as shown below or the port s built-in 120-Ohm termination. If line termination other than 120 Ohms is required, an appropriate external resistor must be supplied. User-Supplied Termination for RS-485 Full Duplex 4-Wire RS-485 6 3 Terminating Resistor Half Duplex 2-Wire RS-485 2 1 Terminating Resistor Built-in Termination for RS-485 Termination using the built-in 120-Ohm resistor can be provided by either setting the appropriate RS-485 termination jumper OR by installing shorting jumpers on the RS-485 cable connector that attaches to the serial port. Internal 120-Ohm Termination, Default Jumper Positions Full Duplex Four-Wire RS-485 Half Duplex Two-Wire RS-485 Front of Module with Faceplate Removed Side of Port Connector Jumper for Full Duplex, 4-Wire in Default (Upper) Position Jumper for Half Duplex, 2-Wire in Default (Upper) Position Move top jumper down or connect Port pins 7 and 3 Leave bottom jumper in Default Position Leave top Jumper in Default Position Move bottom jumper down or connect Port pins 4 and 1 To set 120-Ohm termination internally: 1. Remove the module s faceplate by pressing in on the side tabs and pulling the faceplate away from the module. 2. With the module oriented as shown, move either the upper or lower jumper: