Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

Similar documents
CURRENT PRODUCT OVERVIEW

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Intrinsically safe batch controller Batching Master 110i

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Standstill monitor A / / 2011

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Technical Manual Room temperature controller

DCC-XP V3.3 and ADC. Compact compound control with integrated condensation pressure control. Front view. Characteristics

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Operating instructions Evaluation system for flow sensors VS / / 2013

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

MDM 011-Z1 Regen Resistor

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Operating instructions. Speed monitor D / / 2014

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Operating Instructions

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Supplementary operating instructions for your air curtain system Controller TMC 500

Industrial motor controller for brushed DC motors 24 VDC

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

BMF400 Input/output module

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

igus motion Plastics dryve D3, DC-Motor Control System

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Instruction Manual for 1-Phase 1Q-Power Controller Temvar GE_3

Manual Control Unit GFC 32

Assembly and Operating Instructions. NFC module for BDC-i440 control units

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Instructions for Level Switch for Liquids. Model: RFS

User Manual HMI Linkbox HL01 DP/MPI

CMC III Universal Sensor

MID approval no. DE-08-MI004-PTB004 Date of release

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

RXTP ROOM TEMPERATURE

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Industrial motor controller for brushed DC motors 24 VDC

SK TU4-CAO-C Part number:

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

HT-SG-100. Electronic Gas Engine Speed Governor. Smart Governing. Benefits

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Installation Instructions

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

SK CU4-EIP-C Part number:

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Analog Monitor Installation Manual

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating Instructions

Siemens Industrial s

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

RТTH DUAL ROOM SWITCH

ST (6ES7132-6FD00-0BB1)

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

RXTH DUAL ROOM SENSOR / SWITCH

Installation Instructions

Digital Quick-Response Thermometer

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

COMPACT eco -DIN Document Rev1

D1210H dimmer pack. user manual

PI-EX-ME-2NAM/COC-24VDC

Manual Simatek Control Unit GFC 32

Operating Manual -ENGLISH- Page 1 KWG-ISO

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

DDC110-L1.. DDC110-L4 technolon Room Module

Controller unit for solar thermal systems. grandis 600 SR. Installation and operating instructions

multisys User manual Technical parameters D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS _EDEBDA _EN

Operating Instructions Differential Pressure Transducer PS27

BNI IOL K023 BNI IOL K023. User s Guide

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

SK CU4-CAO Part number:

Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP

IGLOO IGLOO EASY INSTRUCTION MANUAL

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

LED W RGBA User Manual

EN BU Functional Safety. Supplementary manual for series SK 500E

Transcription:

FKE003 Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve Features Operation of electronic expansion valves pulsed via integrated electronic relay (valve controller 230V~) or ATV230 (valve controller 230V ~/=) Control of one evaporator per module Integrated temperature display Tool-free front installation Fixed input/output allocation for probes, control inputs and relays Emergency program in case of bus errors External power supply over TR9-9-4 Secure connection via prefabricated accessories (ZCB) Front panel with seal frame for increased splash protection Connection to main module via field bus (CAN bus) FKE003_PI_2013-06_EN Subject to technical changes Page 1 of 8

Writing conventions Symbol Meaning CAUTION! Avoid the described hazard: Otherwise minor or medium bodily injury or property damage will result. WARNING! Avoid the described hazard: Otherwise there is danger from electric voltage that can lead to death or serious bodily injury. For your safety For safe operation and to avoid personal injury and equipment damage through operational error, always read these instructions, become familiar with the device, and implement all of the safety instructions on the product and in these instructions as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device when the product is sold. Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in case of improper use or use for other than the intended purpose. Target group Intended use These instructions are intended for "service technician" personnel. The FKE003, which is installed in refrigerators, is a field module for cold locations. WARNING! Danger of death from electric shock! Switch off the power to the entire system when installing, wiring or removing! Otherwise, external voltage can be present even when control voltage is shut off! The wiring of the device should be carried out only by a qualified electrician! Use only the correct tools for all work! Check all wiring after connection! Never expose the device to moisture, for example due to condensation or cleaning agents! Take the device out of operation if it is faulty or damaged and is therefore compromising safe operation! CAUTION! Danger of fire if there is overloading of the connections! Ensure the maximum loads on all connections! Faults are caused by electromagnetic interference! Use only shielded data lines and place them far away from power lines! Damage to device if handled incorrectly! Do not open the device. Do not repair the device yourself! If required, send it in for repair with an exact description of the fault! Software revisions and validity of documentation Software version Functional upgrade Page V2.0 2011-08 Basis of documentation 2012-02 Circuit diagram: Labelling of the joint sensor connections inserted 3 2012-09 Device operation, parameters list and listing of prefabricated cables added 2013-06 ZCB-C/REL2M-5P Any software versions not listed are special solutions for individual projects and are not documented in detail in this description. This document automatically ceases to be valid if a new technical description is issued. Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme. For further information, see our website at www.wurm.de Page 2 of 8 Subject to technical changes FKE003_PI_2013-06_EN

Contents 1 Circuit diagram... 3 2 Assembly / connections...3 3 Controls and indicators... 5 4 Device operation... 5 4.1 Activating the advanced level... 5 4.2 Selecting parameters... 5 4.3 Setting parameters... 6 4.4 Set module number... 6 4.5 Block keys against unauthorised operation... 6 5 Parameter... 7 6 Fault messages and emergency programs... 8 7 Technical data... 8 1 Circuit diagram 2 Assembly / connections 158 120 150 x 32 28 0,6... 3,5 72 61 120 Installation section FKE003_PI_2013-06_EN Subject to technical changes Page 3 of 8

All connections are designed as plugs for prefabricated cable. Connections for prefabricated cables The following cables, bud adapters and terminating resistors are available for FKE003. Cables Use ZCB-C/TR-0,6 Controller transformer 0.6m ZCB-C/TR-2,0 Controller transformer 2.0m ZCB-C/REL2M-5P Controller - load (solenoid valve, defr., fan, EEV) 2.0m sheathed cable ZCB-C/DI-2,0 Controller - digital inputs 2.0m ZCB-C/DI-7,0 Controller - digital inputs 7.0m ZCB-C/AI-2,0 Controller - analogue input 4...20mA, 2.0m ZCB-C/AI-7.0 Controller - analogue input 4...20mA, 7.0m ZCB-C/AO-2,0 Controller - analogue output 0...10V, 2.0m ZCB-C/BUS-0,6 Controller - controller/bus adapter, 0.6m ZCB-C/BUS-4,5 Controller - controller/bus adapter, 4.5m Bus adapter ZCB-ADP/BUS End resistor ZCB-ADP/R Use Bus adapter Use Terminating resistor for CAN bus Page 4 of 8 Subject to technical changes FKE003_PI_2013-06_EN

3 Controls and indicators P 3 4 1 2 LEDs and 7-segment display 1 Parameter change approved 2 Advanced level 3 Status LEDs 4 Value/parameter number Display symbols Defrosting Cooling Fan 4 Device operation The setting menu is divided into 2 distinct function areas, the standard level and the advanced level. The standard level encompassed only the display of the control actual value and the status LEDs. The advanced level encompasses all parameters (P01 to P16). 4.1 Activating the advanced level 1. To switch to the advanced level, press the <P> key for 5 seconds. The LED "Advanced level" will flash for as long as the level is released. P... 2. To return to the advanced level, press the <P> key again for 5 seconds. If no key is pressed within 2 minutes, the display automatically returns to the standard level. 4.2 Selecting parameters 1. Press the <P> key to display the parameter number. The parameter number will appear in the display for as long as the key is depressed. 2. To select individual parameters with the <P> key depressed, press the or key. When the keys are released, the value corresponding to the parameter is displayed. P 5sec.... P P P P FKE003_PI_2013-06_EN Subject to technical changes Page 5 of 8

4.3 Setting parameters 1. Select the parameter to be adjusted (having previously released the advanced level if necessary). 2. Parameter change approved. Press all 3 keys simultaneously for 5 seconds. The LED "Parameter change approved" flashes. 3. Change the values using the or keys. P P P P When changing the parameters, it is not necessary to re-enable access to make further value adjustments. Current values are simply displayed. They cannot be adjusted even if the LED "Parameter change approved" is flashing. 4. To disable parameter change, press all 3 keys simultaneously again for 5 seconds. If no key is pressed within 2 minutes, the display automatically returns to the standard level and parameter change is disabled. The jump back is always made to the temperature display. 4.4 Set module number Note! 3 x Service button => address P11 To simplify setting of the module number (P11), it is possible to go directly to the menu position by pressing the Service button of the device (behind the front plate) 3x in rapid succession. All that is needed now to set the address is to release parameter adjustment. 4.5 Block keys against unauthorised operation Note! 5sec. Service button + =>keys blocked If the Service button and the arrow key are pressed simultaneously for 5 seconds, the keyboard (3 visible keys) is blocked. An effective block is confirmed by displaying the text ""noop" for 1 second. Blocking the keys simultaneously exits the advanced level and branches to the standard menu. Access is also blocked if it was released before. When the keys are blocked, any time a key is pressed the block is indicated by the access and advanced level LEDs lighting up; this way the device will not incorrectly be considered defective. Page 6 of 8 Subject to technical changes FKE003_PI_2013-06_EN

Note! 5sec. Service button + P =>buttons free The block can be removed by pressing the Service button together with the Menu button "P" for 5 seconds. Removal of the block is signalled by the appearance of the text "FrEE" for 1 second. 5 Parameter Standard level: Actual value No. Parameter Default Min. Max. Description P00 Control actual value - - Current actual value of temperature control Advanced level: Actual values and setpoints No. Parameter Default Min. Max. Description P01 Actual value of supply air - - Temperature of supply air probe F1 P02 Actual value of return air - - Temperature of return air probe F2 P03 P04 Actual value of defrosting limit probe Actual value of suction gas temperature - - Temperature of defrost limit probe F3 - - Temperature of suction gas probe F4 P05 Actual value 4..20mA 0 25.5 Current of the 4..20mA input (resolution: 0...25.5mA) P06 Actual value 0..10V output 0 100 Triggering of the 0...10V output (resolution: 0...100%) P07 Probe type supply air F1 277 - - P08 Probe type return air F2 277 - - P09 Probe type defrost limit F3 277 - - Type of the temperature probe to be set on the main module Type of the temperature probe to be set on the main module Type of the temperature probe to be set on the main module P10 Probe type suction gas temperature F4 277 - - Type of the temperature probe to be set on the main module P11* Address 0 0 7 Set module number (field bus address) P12 Version - - Applied device version P13* Relay test function 0 3 0 = all relays off 1 = defrost 2 = cooling 3 = fan The relay test is automatically deactivated when the menu is exited or no further buttons are pressed within 2 minutes. P14 Status of input: CLR OFF OFF OFF ON Current status of digital input DI1 P15 Status of input: 2. Setpoint OFF OFF ON Current status of digital input DI2 P16 Status of input: Door open OFF OFF ON Current status of digital input DI3 *Adjustable parameters FKE003_PI_2013-06_EN Subject to technical changes Page 7 of 8

6 Fault messages and emergency programs In case of a fault, the display flashes with the fault code. Display Fault cause Monitoring function and emergency program COLL bus ErCo EE 7 Technical data Supply voltage Connections Communication Temperature probe Analogue input Digital inputs Outputs Output relay Address collision at the bus Bus fault No bus communication Bus communication error Data fault in non-volatile memory Electronic semiconductor relay The set module number is already assigned. Set a different module number! Check bus connection! The device has detected activities on the field bus, but is not being controlled by the corresponding main module. Check address setting and parameter settings of the main module! A power surge may destroy the set parameters. Operation is carried out with the factory default settings. Re-enter all memory locations. De-energise the control unit! Over transformer TR9-9-4 with plug connection Plug for prefabricated connecting cable ZCB 3-wire CAN-BUS interface, electrically isolated 3 x TRK277/5ST-PLUS, Standard connection: Supply air, return air, defrost limit 1 x TRK-EEV/7ST: Suction gas 4...20mA 3 x inputs for voltage free contacts: 1 x cold room off, 1 x 2. Setpoint, 1 x cold room door open The total current of the output relay and electronic relay must not exceed 6A. 1x cooling, opening contact, 230V~, 3(2)A 1x fan, opening contact, 230V~, 3(2)A 1 x defrost, closing contact, 230V~, 3(2)A 1 x control of a pulse-width modulated EEV, 230V~, 4VA 60VA, Observe minimum power! Residual voltage measurable! Integrated semiconductor protection (no isolator) Analogue output 1 x 0...10V=, tied to potential, capable of bearing max. 1mA, alternatively for control of an electronic relay ATV230 (valve 230V ~/=) Housing Plastic housing Dimensions (WxHxD) 158 x 32 x 75mm³ Mounting See installation instructions Ambient temperature 0...+50 C (operation) IP protection class IP54 Weight About 150g CE conformity EC conformity according to - 2004/108/EC (EMC Directive) - 2006/95/EC (Low Voltage Directive) RoHS Valid from Version 2.0 Page 8 of 8 Subject to technical changes FKE003_PI_2013-06_EN