LIGHTPLANE 3.5 WET LOCATION LP3.5WL Suspended, Wall, Surface LED Find additional images and information at alwusa.com/lp35wl
1. BASE MODEL LP3.5SDWL 3-1/2 suspended stem-mount direct, wet location LP3.5WIWL 3-1/2 wall-mount indirect, wet location LP3.5WDWL 3-1/2 wall-mount direct, wet location LP3.5SMBWL 3-1/2 wall/surface, back-mounted, wet location Page 2 of 5 Type: 2. RUN LENGTH/ SIZE Individual 1,3 (2', 3' or 4') Factory-joined 1,2,3 (5', 6', 7' or 8') 1 Luminaires are NOT field-joinable. Longest uninterupted length is 4'. Longest joined length is 8'. 2 A wet location joiner, pre-installed in the factory, connects two indivdual sections together to achieve luminaire lengths of 5'-8'. The lens and the lamping in these longer-length luminaires, therefore, are NOT continuous. See page 4 for visual reference. 3 All lengths are nominal and may vary based on lamping and other specfication selections. Consult factory when exact lengths are required. 3. LAMPING Pair lamping with CCT (where applicable), ex: MED/2700K LOW 4 Low-output, high-performance LED 517 delivered lm/ft, 7.4 W/lf, 70 lm/w MED HI 4 TUNE 5,6 DECOR 4 RGB 6 RGBW 6 Medium-output, high performance LED 689 delivered lm/ft, 9.8 W/lf, 70 lm/w High-output, high-performance LED 861 delivered lm/ft, 12.2 W/lf, 70 lm/w Tunable white LED, 2700K-5700K 574 delivered lumens, 8.2 W/lf, 70 lm/w Decorative constant voltage LED 252 delivered lm/ft, 5.9 W/lf, 43 lm/w 3000K 4000K Color-changing RGB LED, 5 W/lf Color-changing RGB plus White (4000K CCT) LED, 5 W/lf 4 Performance calculations are extrapolated estimates based on the actual IES test results of MED option at 3500K 5 Performance calculations are extrapolated MAXIMUM estimates for mid-range CCTs based on the actual IES test results of MED option at 3500K. Cooler and warmer CCT settings will provide lower delivered lumens, lower lm/w and higher W/lf. 6 DMX driver recommended; controller not included. 4. DRIVER Pair driver with dimming level (where applicable), ex: 0/10V/S 0/10V/ 0-10V dimming S Standard dimming 7 1% Dimming to 1% 0% Premium dimming to 0% DALI DALI dimming to 0% DMX DMX dimming to 0% ECOSYS1 Lutron Hi-lume 1% EcoSystem, constant current or constant voltage ECOSYS5 Lutron 5-Series 5% EcoSystem, constant current 7 For LOW, MED and HI lamping, standard dimming is down to 5%. For DECOR lamping, standard dimming is down to 10%.
5. LENS EXT/F Extra diffuse, flush Page 3 of 5 EXT/F 6. FINISH AL BK BRS SV WH WH/AM RAL/ NTM 8 Standard, natural Ultimatte aluminum Black powdercoat Brass metallic powdercoat Silver powdercoat White powdercoat White antimicrobial powdercoat for healthcare environments Specify RAL powdercoat code (ex: #RAL/3003) Natatorium finish 8 Natatorium finish is an additional top-coat finish. Select both color finish and NTM. Agents, contact factory with both selections for pricing. 7. VOLTAGE UNV Universal voltage 347 9 347 volt 9 Driver options may be limited with 347 voltage. Consult factory. 8. ADDITIONAL OPTIONS NONE EMC 10 EMB 10 SB TPF None Emergency circuit Emergency battery pack Seismic bracing Top-side power feed location 10 Consult factory for available options
MOUNTING OPTIONS & DIMENSIONS Page 4 of 5 1/4 FOR SURFACE MOUNTING 5 8" 4 8" 5 11 STEM MOUNTING BRACKET 11 3 SURFACE MOUNTING BRACKET LP3.5SD/WL LP3.5SMB/WL 1 4 " Wall Mount Bracket 3 15 3 11 Wall Mount Bracket 3 11 3 15 LP3.5WD/WL 1 LP3.5WI/WL END CAP & FACTORY JOINER ASSEMBLY 1 End Cap POWER FEED WET-LISTED CONDUIT & 1/2"NPS BY OTHERS Joiner Assemby (Not Lensed) STANDARD -- Power feed location on end of of fixture through the end cap. Choose TPF in Additional Options for top-side power feed location.
HOUSING 100% recyclable, extruded architectural grade 6060 T-5 aluminum with.08" minimum wall thickness. ELECTRICAL LED drivers are Class 2. L80 >50,000 hours. 80+ CRI. ETL listed for damp location. OPERATING TEMPERATURE Luminaire should be installed and operated ONLY in environments where the ambient temperature ranges from -4 F (-20 C) to 122 F (50 C). Operating the luminaire in environments outside the listed temperature range voids the warranty AND may damage the product or adversely impact lamp life, lumen output and color consistency. EMERGENCY Luminaires can be wired for emergency circuit and/or emergency battery backup. Consult factory for details. IP RATING FINISH SOLID OBJECT INGRESS LEVEL 6 Dust tight IP 6 6 Page 5 of 5 WATER INGRESS LEVEL 6 Protected against powerful water jets and heavy seas Standard finish is "Ultimatte" aluminum a smooth, clean and durable finish achieved from a deepetch and two-step clear anodizing process. White, black, silver, brass and color RAL powdercoat options also available. For healthcare environments, a white antimicrobial finish (WH/AM) is also an option. LENS Extruded, twin-layered, high-impact acrylic. EXT/F is a white, extra diffuse flush lens with minimal-to-no source visibility. ALUMINUM AL WHITE WH & WH/AM BLACK BK OPTIONS Eye Bolt (By Others) Gripper w/hook 2-Cable Clamp SILVER SV BRASS BRS COLOR RAL Aircraft Cable SEISMIC BRACING Add-on hardward includes cable gripper with hook, 2-cable clamp and specified length of aircraft cable per suspension point