Chameleon Stand-alone

Similar documents
FlatpackS Modules. User's Guide. Rectifiers and Supervision. FlatpackS DC Power Supply Systems. Anatel Homolgation Numbers

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

MC 11 EB-2 Power supply cabinet with external bus, AC version

P216 Series Condenser Fan Speed Controller

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Model 7705 Control Module

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OPLC Installation Guide

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Model 2380 Rack-Mount Kit

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Model HM-535 Power Supply Installation and Service Instructions

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

The identified danger could cause physical and property damage.

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Vision OPLC V TR6/V350-J-TR6

PV Rapid Shutdown device

CPCI-PS24 24V-Power Supply

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Preparing to Install the VG248

Switched Mode Power Supply Operating manual PAP800

P216. Condenser fan speed controller. Product bulletin. Features

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Model 2380 Rack-Mount Kit

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PRO-75 SERIES. User manual

Junos WebApp Secure 5.0 Hardware Guide

Ultra Slim Relays 24

EX-RC1 Remote I/O Adapter

High Power Electronic Gear Installation and operation Guide

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

LVN5200A-R2, rev. 1, Hardware Installation Guide

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

High Speed Remote I/O Module

User Manual. 3KW/5KW PV Inverter

MAXIMA+ Series Rotary Level Indicator

MODEL 805 USER MANUAL

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

Digital Overhead Stirrer

INSTALL INSTRUCTIONS RSXMR-9886-P-48

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

CDD4 Duct Carbon Dioxide Transmitter

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

V E1B Snap-in I/O Module

SAVE THESE INSTRUCTIONS

V E2B Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

MDM 011-Z1 Regen Resistor

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Specifications, Installation, and Operating Instructions

Rhino PSM Power Supplies. Operating Instructions

Installing the Cisco AS5400XM Universal Gateway

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Innovative Circuit Technology Ltd.

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

MAXIMA + Series ROTARY LEVEL CONTROL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

AC-DC Converter REC K10

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SolConeX extra-low voltage flange socket

OPERATING INSTRUCTIONS

PC RELAY TERMINAL/ PC TERMINAL

Vision OPLC. V T38 Installation Guide. General Description

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

Transcription:

Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools & Torque Recommendations..., page 3 Recommended External AC Fuses..., page 3 Overview..., page 4 Block Diagram Chameleon Stand-alone Power Supply Module..., page 4 Dimensions Chameleon Stand-alone Module..., page 4 Mechanical Installation Fastening the Chameleon Module to a Surface or Pole..., page 5 Option : Surface Mounting ~ Prepare the Surface..., page 5 Option : Surface Mounting ~ Fasten the Chameleon Module..., page 6 Option : Pole Mounting ~ Fasten Half Pole Clamps to the Module..., page 6 Option : Pole Mounting ~ Fasten the Chameleon Module to the Pole..., page 7 Electrical Installation Location of Terminals & Management..., page 8 Management..., page 8 Pinout ~ Panel Mount Connectors..., page 0 Location of Terminals ~ Connectors..., page 0 Connections..., page Switch OFF External Fuses..., page Connect the AC Input..., page Connect the DC Output..., page 3 Start-Up Check Lists ~ Pullout Commissioning Procedure

SAFETY and ENVIRONMENTAL PRECAUTIONS Power Supply Systems The product warranty becomes invalid if the following safety precautions are not followed during handling, installation, commissioning and general use/operation of Eltek power supply systems. 356800.83, 3v5 (-I5) Device Hazard Electric Shock General Precautions CAUTION: Even though the product incorporates protection circuitry and other safeguards, it can be damaged, perform poorly or have a reduced lifetime if it is exposed to incorrect treatment during transport, installation or service. Always handle the equipment using proper lifting techniques, do not roll, climb or drill hole in the cabinets or enclosures. WARNING: Opening the equipment may cause terminal injury even if the mains AC supply is disconnected. Hazardous voltages may be present inside, as large capacitors may still be charged. G G Environmental Precautions sss Ventilated Hot Surface Current Surge Protection Humidity & Dust Protection CAUTION: To avoid damage the equipment, keep objects clear of system ventilation inlets, outlets and system fans, if any, ensuring the airflow through the units is not obstructed, and that the fans rotate freely. Use caution with power modules, as they can reach extreme temperatures under load and normal operation. WARNING: The installer/user is responsible for ensuring that the power system is not damaged by current surges, over-voltages, etc. caused by external transients, lightning, electrostatic discharge, etc. To avoid damage and obtain the expected system reliability, it is mandatory to always install SPDs in Eltek s power supply systems. Follow the instructions given in Guidelines for Lightning and Surge Protection, doc. 0463. WARNING: The electronics in the power supply system are designed for indoor, clean environment. When installed in outdoor enclosures using heat sinks or closed loop heat management systems it is important to maintain the equipment closed and tight during operation, to avoid external air entering the enclosure. Also, when using open loop heat management systems, it is important to replace the filters on a regular basis. Indoor installations in dusty or humid areas require appropriate air filtering of the room, or filtering of the air entering the power system. Follow the instructions given in Generic Guidelines Environmental Protection., doc. 038879 E E E3 Precautions during Installation Qualified Personnel EMC, NEC/CEC Regard Device Hazard Electric Shock CAUTION: Read the user documentation carefully before installing and using the equipment, as installation and operation is to be performed as described in it. Always tighten screws and bolts with the torque values recommended in the documentation. For safety reasons, the commissioning and configuration of the equipment is only to be performed by Eltek s personnel or by authorized and qualified persons. CAUTION: This product is tested and verified according to international safety, environmental and EMC standards. Any non-eltek equipment installed into this product after delivery might influence the performance and could infringe the original approvals. The installer is responsible for ensuring that the environmental properties of this product/ system do not deteriorate during installation, and that it is performed in accordance with applying regulations. Installations in USA and Canada must comply with NEC/CEC requirements. CAUTION: Before you start the electrical installation, you must always disconnect all external supply fuses, as well as internal battery and load fuses/ breakers, if any. WARNING: For safety reasons (high leakage current / high touch current) you must always connect the AC earth wire (PE) to the terminals, before you connect the AC input cable(s). The batteries, if any, represent a major energy hazard. To avoid short-circuit of battery poles, you must always remove metallic objects uninsulated tools, rings, watches, etc. from the vicinity of the batteries. I I I3 I4 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Introduction Warnings Electric Shock 0 min. WARNING: Hazardous voltages may be present inside the Chameleon module, Part # 45.55, as long as 0 minutes after it is switched OFF (discharge time) WARNING: If used as PERMANENTLY CONNECTED, a readily accessible disconnect device shall be incorporated external to the equipment If used as PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible. Maximum operational ambient temperature of this equipment is 60 C or, if installed in a RESTRICTED ACCESS LOCATION, 70 C NOTICE: This guide describes the modules: - Part 45.05, Chameleon Module 48V, 650W, HE, IP65 - Part 45.55, Chameleon Module 48V, 650W, HE, IP65, 00ms - Part 45.85, Chameleon Module 48V, 650W, HE, IP65, UI For technical specifications and functionality description, refer to the following: - 45.XX.DS3, Datasheet Chameleon 48V, 650W, HE, Rectifiers - For generic power system functionality, refer to CWUI Online Help Tools & Torque Recommendations Tools W Torque T-IW Type & Size Torque Recommendations Torque (Nm) T M5 screws (x) (fastening module to clamps) 5.0 PZ Flat (.5 mm) T-PZ T-F T M5 bolts (4x) (fastening half pole clamps) 3.0** T3 AC Mains Input Terminals (4x) 0.3 T4 DC Output Terminals (7x) 0.4 T5 Coupling rings on the cable connectors inserts.5 T6 connectors sleeves 0.5 T7 connectors pressing screws. See Table 3 on page 9 Note: General tolerance: ±0% ** T s exact tightening moment may vary a little depending on the type of half pole clamps used and the diameter of the pole Table. Torque recommendations Recommended External AC Fuses AC Type Recommended External AC Fuses Chameleon 48V, 650W, HE Stand-alone Modules Table. Rectifier: Chameleon 48/650 HE Fuse Type 30VAC phase 0A C-char or 6A D-char Th/Mag (Doc 6770, v0) Recommended external AC fuses Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module 3

Introduction Overview Block Diagram Chameleon Stand-alone Power Supply Module Chameleon 48V, 650W, HE Stand-alone Module AC Fuses, external AC Input (30V x phase) CAN bus Alarm Relay C-NO Telecom & Industrial Equipment (Load) DC Output (48V) Dimensions Chameleon Stand-alone Module W = 96.0 All dimentions in mm (not in scale) D = 06.6 Panel Mount Connectors H = 30.6 or 450.0 (Ref. Doc# 75763, v.0) Chameleon Stand-alone Module Part 45.05 (.8Kg, H=30.6) Part 45.85 (.8Kg, H=30.6) Part 45.55 (3.6Kg, H=450.0) 4 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Mechanical Installation Fastening the Chameleon Module to a Surface or Pole NOTICE: Use acid proof (A4) screws or bolts (not included) suitable for the mounting surface and outdoor environment, to fasten the Chameleon module to the wall or support surface (e.g. wall plugs, expansion bolts, molly bolts, etc.) Or use suitable half pole clamps (included in Pole Mount Kit, Part 45.90), if the module is to be pole mounted Suitable Screws or Bolts Halv Pole Clamps 40-95 mm Ø CAUTION: The wall or support surface or pole must be capable of supporting the equipment:.8 Kg or 3.6 Kg, ±0%, depending on the Chameleon Stand-alone Module Halv Pole Clamps 90-35 mm Ø WARNING: Never mount the Chameleon Stand-alone Module in the vicinity of heaters or above hot sources Pole Mount Kit Part 45.90 Option : Surface Mounting ~ Prepare the Surface Get ready suitable acid proof (A4) screws or bolts (x) Mark the center line, then drill suitable holes in the wall D Part 45.05 (D=30.5) Part 45.85 (D=30.5) Part 45.55 (D=43.4) All dimentions in mm (not in scale) Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module 5

Mechanical Installation Option : Surface Mounting ~ Fasten the Chameleon Module (x) Suitable acid proof (A4) Screw or Bolt Chameleon Stand-alone Module 3 CW Option : Pole Mounting ~ Fasten Half Pole Clamps to the Module M5 (x) T-PZ CW T Pressure Equalization Vent 4 Half Pole Clamp 3 Chameleon Stand-alone Module Device Hazard WARNING: Do not open, close or change the Pressure Equalization Vent, which provides pressure equalization and condensation reduction, and resists liquid immersion, dust and dirt while allowing the product to breath during changing environmental conditions 6 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Mechanical Installation Option : Pole Mounting ~ Fasten the Chameleon Module to the Pole 333 Pole 333 Half Pole Clamp Half Pole Clamp Chameleon Stand-alone Module CW M5 (4x) T-IW T 4 555 555 555 WARNING: Both bolts tightening a half pole clamp pair must be screwed almost at the same time and the same length, maintaining the half pole clamps paralleled while fastening Chameleon Stand-alone Module (Top View) Chameleon Stand-alone Module (Top View) 7 A A Pole B B Half Pole Clamp A=B OK 6 A B NOT OK Optionally, you can cut the clamp bolts to suitable lengths after fastening them (steps 6 and 7). Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module 7

Electrical Installation Location of Terminals & Management Power is OFF Management Chameleon Stand-alone Module Insert, male with Coupling Ring Sleeve with Pinch Ring Seal Ring, SR Pressing Screw Connector, female A (Part 343665) Panel Mount Connector, male Panel Mount Connector, female Connector, male F (Part 343667) Seal Ring, SR Seal Ring, SR connectors A and F shown above are suitable for a wider cable outer diameter range. connectors B-E and G-J are shown below. Refer to Table 3. Selection of Connectors on page 9 Insert, female with Coupling Ring Pressing Screw Sleeve Pinch Ring Seal Ring Insert, male with Coupling Ring 8 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

PULLOUT Check Lists Pullout Pull out the pages with the gray outer band, and use them as check lists

Form 86-gb-v-C0 System Data COMMISSIONING PROCEDURE Supplier s Order No.: Chameleon Stand-alone Module, type: Article No.: Chameleon Module Site, name: Serial No.: Software, version No.: AC Input Voltage, measured: Commissioning carried out by, name: I Device Hazard Electric Shock 0 min II Device Hazard Pre-Start Check CHECK FOLLOWING:. Chameleon Stand-alone installation is completed; Power is OFF All cabling is securely terminated. Site specific parameters are known 3. All external load MCBs/ fuses are switched OFF 4. All external AC mains MCBs/ fuses are switched OFF; AC supply is OFF Hazardous voltages are present inside Chameleon module, Part # 45.55, as long as 0 min. after switch OFF 5. Both cable connectors are correct type The correct type must be suitable for the cables outer diameter. Refer to the QI guide, doc. 356849.03 6. AC input cable and AC earth wire (PE) are terminated in the input cable connector 7. DC output cable is terminated in the output cable connector 8. The input and the output cable connectors are plugged in the Chameleon module Start-up, No-Load Measurements CARRY OUT FOLLOWING: OK Power is ON. Unplug the Output Connector from the module. Switch ON the system (external AC MCBs/fuses ON) 3. DC output voltage; Measure at the module s output panel mount connector, pin & Verify correct output voltage (-43V to 58V, ±V) 4. Alarm relay test; Verify that the alarm contacts (max. 30VDC, A), on the module s output panel mount connector, work OK Measure resistance between pin 5 & 6 (AL C AL NC) R> 00MΩ normal condition, coil energized Unplug the AC Input Connector R 0Ω alarm condition, coil de-energized Plug again the AC Input Connector OK 5. Plug again the Output Connector to the module 6. Switch ON external load MCBs/ fuses, If possible, verify that the load is supplied with correct voltage (-43V to 58V, ±V) Approval Responsible of commissioning, sign.: Date: Approved by customer, sign.: ()

PULLOUT

Check Lists Pullout Pull out the pages with the gray outer band, and use them as check lists PULLOUT

Electrical Installation Select the cable connector type that corresponds to your cable outer diameter, ±0. mm Connectors Selection Table Type Connector Type Function Outer Diameter Connector Type Eltek s Part No. Binder s Part Number Pressing Screw s Torque Input 7 mm 7.0 3 mm A Input Connector (SR) Input Connector (SR) 343665 99-4-300-04 (3+PE).6.0 Nm 0.8.4 Nm Input 6.0 9.5 mm B Input Connector 3343 99-4-00-04 (3+PE) 0.8.0 Nm Input 8 0 mm C Input Connector 3343 99-4-0-04 (3+PE).0.4 Nm Input 0 mm D Input Connector 33433 99-4-4-04 (3+PE).0.4 Nm Input 4 mm E Input Connector 34804 99-4-60-04 (3+PE).0.4 Nm Output 7 mm 7.0 3 mm F Output Connector (SR) Output Connector (SR) 343667 99-47-300-07 (6+PE).6.0 Nm 0.8.4 Nm Output 6 8 mm G Output Connector 33438 99-47-00-07 (6+PE) 0.8.0 Nm Output 8 0 mm H Output Connector 33439 99-47-0-07 (6+PE).0.4 Nm Output 0 mm I Output Connector 334330 99-47-4-07 (6+PE).0.4 Nm Output 4 mm J Output Connector 34805 99-47-60-07 (6+PE).0.4 Nm Table 3. Selection of Connectors Circular Cross Section WARNING: To avoid corrosion of the screw terminals and field failures not covered by the warranty, always use cables with circular cross section, and cable connectors and seal rings suitable for the cable s outer diameter The cable connectors in Table 3 on page 9 are suitable for PUR and PVC type cables with circular cable cross section Device Hazard Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module 9

Electrical Installation Pinout ~ Panel Mount Connectors PE 3 L Pinout Panel Mount Input Connector (not connected) Pinout Panel Mount Output Connector -48VDC + 0VDC L/N (not connected) 6 AL-NO 5 AL-C Contacts shown with de-energized coil (Alarm condition) 3 CAN H 4 CAN L Chameleon Stand-alone Module Location of Terminals ~ Connectors 3 L L/N AC Mains Input Terminals Contacts shown with de-energized coil (Alarm condition) DC Load Output Terminals 6 AL-NO 5 AL-C 4 CAN L 3 CAN H (Not Connected) Flat.5mm T3 Flat.5mm T4 + 0VDC -48VDC Chameleon Stand-alone Module Insert, male with Coupling Ring Sleeve with Pinch Ring Seal Ring Pressing Screw Connector, female A (Part 343665) Connector, male F (Part 343667) Seal Ring, SR Seal Ring, SR For torque reference T3, T4, read Tools & Torque Recommendations on page 3 0 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Connections Electrical Installation Power is OFF Switch OFF External Fuses Current Surge Protection WARNING: For outdoor applications where the product may be subject to transient overvoltages exceeding those for Overvoltage Category II, an AC Overvoltage Protection Device (OVP) complying with IEC 6643-series must be installed on the AC supply. This device will reduce the overvoltages to levels corresponding to Overvoltage Category II U5 Ua A CAUTION: Suitable for connection to IT networks For installations in USA and Canada only The installation has to comply with the NEC/CEC requirements Device Hazard WARNING: The other ends of the AC input and DC output cables must be terminated in a protected box or plug of at least IP 65 rating, or in an indoor environment Switch OFF external AC Mains MCBs/Fuses Switch OFF external Load MCBs/Fuses Electric Shock 0 min. WARNING: Hazardous voltages may be present inside the Chameleon module, Part # 45.55, as long as 0 minutes after it is switched OFF (discharge time) Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Electrical Installation Connect the AC Input N 8 7mm 9 AC Mains Tin wires (3x) 5mm CAUTION: The rectifier incorporates a Mains fuse in each line. Double Pole / Neutral Fusing 7 6 U 4 L/N 3 L 5 Connector, female A (Part 343665) AC Mains CCW CCW AC Mains Input Terminals 3 Use similar connection procedure for input cable connectors B through E 0 Connect AC Mains cable Max 0.5.5mm (0 4 AWG) AC Mains CW T6 Chameleon Stand-alone Module T7 CW 5 4 3 AC Mains T5 7 6 CW Connector, female A (Part 343665) For torque reference T5-T7, read Tools & Torque Recommendations on page 3 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Electrical Installation Connect the DC Output 5mm 8 9 7mm Tin wires (7x) DC Output 7 4 5 Connector, male F (Part 343667) CCW 3 6 CCW WARNING: Careful Use correct polarity The DC Load s wire cross section must be.5 mm (pin & ) Relay contacts shown with de-energized coil (Alarm condition) The Earth terminal in the output panel mount connector is not connected inside the module DC Output 5 AL-C 6 AL-NO 4 CAN L 3 CAN H DC Load Output Terminals Use similar connection procedure for output cable connectors G through J DC Output T7 CW 5 4 CW 3 T6 0 +0V 48V Connect DC Output cable Max 0.4.5mm ( 6 AWG) 7 DC Output T5 6 CW Chameleon Stand-alone Module Connector, male F (Part 343667) For torque reference T5-T7, read Tools & Torque Recommendations on page 3 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module 3

Electrical Installation 4 Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module

Refer to the steps in the pull-out form Commissioning Procedure Start-Up Quick Installation Guide Chameleon 48V, 650W, HE, IP65, Stand-alone Module 5

, Published 05--5 This product is CE marked and complies with all current requirements for relevant standards and directives. Headquarters: Eltek Visitor address: Gråterudveien 8, 3036 Drammen, Norway Phone: +47 3 0 3 00 Fax: +47 3 0 3 0 www.eltek.com