CHAPTER 1 GENERAL INFORMATION

Similar documents
PCL-818L High-performance DAS card with programmable gain

PCL channel Isolated Digital Output Card

Registers Format. 4.1 I/O Port Address

Model PCL Six Channel D/A Output Card

PCL-1800 High-speed DAS card with programmable gain

NuDAQ ACL-8112 Series Enhanced Multi-Function Data Acquisition Card

NuDAQ ACL-7120A. Digital I/O & Timer/Counter Card User s Guide

NuDAQ. ACL-8112 Series Enhanced Multi-Functions Data Acquisition Cards User s Guide

AD3300/ADA3300 User s Manual

Register Map for the PCIM-DAS16JR/16

AD2110/ADA2110 User s Manual

AD3500/ADA3500 User s Manual


NuDAQ. ACL-8112 Series Enhanced Multi-Functions Data Acquisition Cards. User s Guide

DA800 User s Manual Real Time Devices, Inc.

ACL Channels Isolated Digital I/O Card

PCL channel Isolated Digital I/O Card

User's Guide. PCI-DAS08

DIO-64/DIO-48. User s Manual

PCI4400. Hardware Manual. Analog Data Acquisition Board for IBM PC AT with PCI bus. RTD USA BME Laboratories. PCI4400 Hardware Manual

PCM ch Isolated Digital I/O Module. User Manual

DM408/DM5408 User s Manual

Features. RoHS COMPLIANT 2002/95/EC

DM5416 User s Manual. Real Time Devices, Inc. Accessing the Analog World. Publication No /20/96

NuDAQ ACL-8316/ /12-bit High Performance DAS Cards with 1K FIFO User s Guide

cpci-9112/pci CH, 12-bit DAS Card for PCI / 3U ComapctPCI (C/C++ & DLL Library)

MSI-P415 USER MANUAL

PC27E LOW COST 16 CHANNEL 12 BIT A/D CONVERTER BOARD

PCI-1751U. 48-bit Digital Input/Output Card with Universal PCI Bus. User Manual

PCL-818 Series. 12-bit ISA Multifunction Card. User Manual

A 40-pin connector provides access to 24 DIO connections.

M ICROSTAR LA BORATORIE S TM

Now on Sale, Shop for the ACL-6126 Here. ACL Ch 12-Bit voltage & current output card from ADLINK

NuDAQ ACL Isolated Digital I/O Card. User s Guide

Technical Information Manual

PCIe-862x Series Board User Manual

MSI-P440 USER MANUAL

E Series Multifunction I/O 1.25 MS/s, 12-Bit, 16 or 64 Analog Inputs

User s Guide. Shop online at OME-A826PG ISA-Bus Multi-Functional Board. Hardware Manual

DM210/DM5210 User s Manual

Specifications USB-1408FS

CIO-DAS802/16 Analog Input and Digital I/O User's Guide

ONYX-MM-XT PC/104 Format Counter/Timer & Digital I/O Module

PCI bit Digital Input/ Output Card for PCI Bus. User s Manual

16-Channel 16-Bit PMC Analog I/O Board

PCL-740 Serial Communication RS-232/422/485/Current-Loop Interface Card

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

NuDAQ ACL bit High Resolution Data Acquisition Card User s Guide

DIAMOND-MM Multifunction Analog I/O PC/104 Module

PCI-DAS1602/12 Specifications

PC-CARD-DAS16/12 Specifications

Model PCL Bit Digital I/O Card

NuDAQ ACL Multi-Functions Counter/Timer Card. User s Manual

NuDAQ ACL User s Manual

PC-CARD-DAS16/16 Specifications

Technical Information Manual

Lecture-50 Intel 8255A: Programming and Operating Modes

Low Cost Multifunction I/O 100 ks/s, 12-Bit, 8 Analog Inputs

DaqBoard/1000. Series 16-Bit, 200-kHz PCI Data Acquisition Boards

PCM PC/ bit Digital I/O Module. User Manual

M ICROSTAR LABORATORIES TM

PC104P-16AIO Bit Analog Input/Output PC104-Plus Board

Technical Information Manual

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.02

30/05/96 V465 User's Manual CHIMERA VERSION TABLE OF CONTENTS

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.02

CPCI-AD32. Intelligent DSP Based 32 Channel Analog Input Card for 3U CompactPCI systems REFERENCE MANUAL Version 1.

CPCI-16AIO Channel 16-Bit Analog I/O CPCI Board With 8 Input Channels, 8 Output Channels, and Auto calibration

PCI-1714 PCI-1714UL. User Manual

EX Ch. Opto-isolated Digital Input Module OPERATING GUIDE

PC104-CTR10HD. User s Manual

16AIO Bit Analog Input/Output Board. With 16 Input Channels and 8 Output Channels

AIO AH-PCI. Features. Packing List. 12-bits Analog I/O Board (High Gain) for PCI AIO AH-PCI 1. Ver.1.04

DAQ-801/802 Data Acquisition System

Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE AI-1616L-LPE 1. Ver.1.01

Chapter 2 Installing the OM-USB-1408FS... 9 What comes with your OM-USB-1408FS shipment?... 9 Hardware... 9 Additional documentation...

DM6604 / DM5604 User s Manual

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.01

CIO-DAS16/330 USERS MANUAL. Revision 5A

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.01

8254 is a programmable interval timer. Which is widely used in clock driven digital circuits. with out timer there will not be proper synchronization

PMC-12AIO. 12-Bit PMC Analog Input/Output Board

PMC-16AIO 16-Bit Analog Input/Output PMC Board With 32 Input Channels, 4 Output Channels and 16-Bit Digital I/O Port

PCI-DAS6402/16 Specifications

ATC-AD8100K. 8 Channel 100 khz Simultaneous Burst A/D in 16 bits IndustryPack Module REFERENCE MANUAL Version 1.

USB-1602HS-2AO Specifications

Manual DMM-XT. Diamond Systems

Specifications PMD-1208FS

16AIO 16-Bit Analog Input/Output Board With 32 Input Channels, 4 Output Channels and 16-Bit Digital I/O Port

DIAMOND-MM-32-AT 16-Bit Analog I/O PC/104 Module with Autocalibration

12-Channel, 12-Bit PMC Analog Input/Output Board

PCI-12AIO 12-Bit Analog Input/Output PCI Board

Twin Rotor Mimo System

AIO UE3-PE. Features. 1MSPS 12-bit Analog I/O Board for PCI Express AIO UE3-PE 1. Ver.1.01

PCL Port RS-232 Interface Card

EX Multi-function DAS Cards User s Guide

APCI-ADADIO. Introduction. Warning. Features. Getting Started

USB-201-OEM. Analog and Digital I/O. User's Guide

PCLD-8751 PCLD User Manual

104-AIO16A and 104-AIO16E. PC/104 HIGH-PERFORMANCE ANALOG I/O BOARDs USER MANUAL

Transcription:

PCL 812

CHAPTER 1 GENERAL INFORMATION 1.1 Introduction The PCL-812PG is a high performance, high speed, multi-function data acquisition card for IBM PC/XT/AT and compatible computers. The high-end specifications of this full-sized card, and complete software support from third-party vendors makes it ideal for a wide range of applications in industrial and laboratory environments. These applications include data acquisition, process control, automatic testing and factory automation. 1.2 Key Features * 16 single-ended analog input channels * An industrial standard 12-bit successive approximation converter (HADC574Z) to convert analog inputs. The maximum A/D sampling rate is 30 KHz in DMA mode. * Software programmable analog input ranges. Bipolar: ± 10V, ± 5V, ± 2.5 V, ± 1.25V ± 0.625 V ± 0.3125 V * Three A/D trigger modes: Software trigger Programmable pacer trigger External pulse trigger * The ability to transfer A/D converted data by program control, interrupt handler routine or DMA transfer. * An Intel 8253-5 Programmable Timer/Counter provides pacer output (trigger pulse) at the rate of 0.5 MHz to 35 minutes/pulse. The timer time base is 2 MHz. One 16-bit counter channel is reserved for user configuration applications. * Two 12-bit monolithic multiplying D/A output channels. An output range from 0 to +5V or 0 to +10V can be created by using the on-board -5V or -10V reference. This precision reference is derived from 1

General Information PCL-812PG A complete software product catalog is available free from your local PC-LabCard representative. 1.5 Product Specifications 1.5.1 Analog Input (A/D Converter) Channels: 16 single-ended Resolution: 12 bits Input Range: Bipolar ± 10V, ± 5V, ± 2.5 V, ± 1.25 V, ± 0.625 V, ± 0.3125 V. All input ranges are software programmable. Overvoltage: Continuous ± 30V max. Conversion type: Successive approximation Converter: HADC574Z (built-in sample and hold) Conversion speed: 30 KHz max. Accuracy: 0.015 % of reading ± 1 bit Linearity: ± 1 bit Trigger mode: Software trigger, on-board programmable timer or external trigger. Data transfer: Program control, Interrupt control or DMA External trigger: TTL or compatible, load 0.4 ma max. at 0.5V (low) or 0.05 ma max. at 2.7V (high). 4

General Information PCL-812PG 1.5.4 Digital Output Channel: 16 bits Level: TTL compatible Output voltage: Low - Sink 8 ma at 0.5 V max. High - Source -0.4 ma at 2.4V min. 1.5.5 Programmable Timer/Counter Device: Intel 8253 Counters: 3 channels, 16-bit, 2 channels permanently connected to 2 MHz clock as programmable pacer, 1 channel free for user application Input, gate: TTL/DTL/CMOS compatible Time base: 2 MHz Pacer output: 35 minutes/pulse to 0.5 MHz 1.5.6 Interrupt Channel Level: IRQ 2 to 7, 10, 11, 12, 14, 15 jumper selectable Enable: VIA S0, S1 and S2 of CONTROL register 1.5.7 DMA Channel Level: 1 or 3, jumper selectable Enable: Via S0, S1 and S2 of CONTROL register 6

Installation PCL-812PG Fig. 2.1 10

PCL-812PG Installation 2.2.1 Base Address Selection Switch name: SW1 Most PC peripheral devices and interface cards are controlled through the input/output (I/O) ports. These ports are addressed using the I/O port address space. Appendix A provides a PC I/O port address map to help you locate appropriate addresses for different devices. The I/O port base address for the PCL-812PG is selectable via an 8- position DIP switch. The PCL-812PG requires 16 consecutive address locations in I/O space. Valid addresses are from hex 200 to hex 3F0; however, you might have used some of these addresses for other devices. Your PCL-812PG base address switch setting is set to hex 220 in the factory. If you need to adjust it to some other address range, the switch settings for various base addresses are illustrated below: I/O Address Switch Position Range (hex) 1 2 3 4 5 6 A9 A8 A7 A6 A5 A4 200-20F 1 0 0 0 0 0 210-21F 1 0 0 0 0 1 220-22F* 1 0 0 0 1 0 230-23F 1 0 0 0 1 1 300-30F 1 1 0 0 0 0 3F0-3FF 1 1 1 1 1 1 Note: ON = 0, OFF = 1 A4...A9 correspond to PC bus address lines * denotes factory setting 2.2.2 Wait State Selection Some high speed PCs may require wait states to be added to the bus I/O to achieve stable data transfer. The PCL-812PG can be configured with 0, 2, 4 or 6 wait state delays for each transfer of data. The length of the wait state can be selected with the positions 7 and 8 on SW1, as shown below: 11

PCL-812PG Installation 2.2.4 Trigger Source Selection Jumper Name: JP1 The A/D conversion trigger source can be internal on-board programmable pacer or external pulse signal (connector CN5 pin 1) Internal pacer trigger: EXT INT TRIG JP1 2.2.5 User's Counter Input Clock Selection (JP2) The programmable timer/counter has 3 channel 16 bit counters. Channel 1 and channel 2 are configured as internal pacer and channel 0 is left for user's applications. The clock input of channel 0 can be internal 2 MHz clock or external clock signal from connector CN5 pin 8. Internal 2 MHz clock: CLK EXT JP2 INT External clock: CLK EXT JP2 INT 13

Installation PCL-812PG 2.2.6 IRQ Level Selection Jumper Name: JP5 The interrupt caused by A/D conversion completion can be level 2 to 7, 10, 11, 12, 14, 15. It is selected by JP5. The user must be aware there is no other add-on card sharing the same interrupt level. No interrupt: X 15 14 12 11 10 7 6 5 4 3 2 JP5 (IRQ) IRQ level 2: X 15 14 12 11 10 7 6 5 4 3 2 JP5 (IRQ) 2.2.7 D/A Reference Source Selection Jumper name: JP3, JP4 The reference voltage of D/A converters can be the internally generated -5 or -10 V or an external reference voltage from connector CN2 pin 17 or pin 19. The reference source of D/A channel 1 (2) is selected by JP3 (4). The reference voltages of both D/A CH1 and CH2 are external: JP3 JP4 INT VREF EXT D/A1 D/A2 14

PCL-812PG Installation The reference of D/A CH1 is internal and that of CH2 is external: JP3 JP4 INT VREF EXT D/A1 D/A2 2.2.8 D/A Internal Reference Selection Jumper name: JP8 The internal reference voltage can be -5V or -10V. It is selected by JP8. The reference voltage is -10V and the D/A output range is 0 to +10V: JP8 10V 5V The reference voltage is -5V and the D/A output range is 0 to +5V: JP8 10V 5V The internal reference is used only when the jumper JP3 or JP4 is set to INT. 2.2.9 A/D Maximum Input Voltage Selection Jumper name: JP9 The A/D converter range can be ± 5V or ± 10V and it is selected by jumper JP9. 15

Installation PCL-812PG ± 5 V MUX Progammable Amplifier A/D converter Gain = 1, 2, 4, 8, 16 ± 10 V If JP9 is set in the ± 5V range, the analog input ranges of PCL- 812PG are ± 5V, ± 2.5 V, ± 1.25V, ± 0.625V and ± 0.3125V. If JP9 is set to the ± 10V range, the analog input ranges are then ± 10V, ± 5V, ± 2.5V, ± 1.25V and ± 0.625V. The default setting of JP9 is the ± 5V range. The user can set JP9 to ± 10V to double the input range. Some PC power supplies offer the bias voltage Vcc + with a voltage less than +12V, e.g. +11.2V. In this case, the output voltage swing range of the programmable amplifier cannot reach +10V and the A/D converter CANNOT make correct measurement if JP9 is set to ± 10V range. A/D converter maximum input range is ± 5V: JP9 10V 5V A/D conveter maximum input range is ± 10 V: JP9 10V 5V 16

Register Format PCL-812PG X 15 14 12 11 10 7 6 5 4 3 2 IRQ JP5 (IRQ) B: Under external trigger source condition (JP1 is set to external) S2 S1 S0 0 0 X Enable external trigger only 0 1 0 Enable external trigger and DMA trasfer data only 1 1 0 Enable program transfer and interrupt transfer using external trigger source. For program transfer, the jumper JP4 must be set to "X" *Note: Set up trigger jumper JP1 on EXT as below before using external trigger mode: EXT INT TRIG JP1 4.8 Programmable Interval Timer/Counter Registers The four registers located at address BASE 0, 1, 2 and 3 are used for Intel 8253 programmable timer/counter. Please refer to Chapter 8 or the 8253 product literature for detailed application information. 30

Москва: Телефон: (095) 234-0636 (4 линии) Факс: (095) 234-0640 BBS: (095) 336-2500 Web: http://www.prosoft.ru E-mail: root@prosoftmpc.msk.su Для писем: 117313, Москва, а/я 81 С.-Петербург: (812) 325-3790 Екатеринбург: (3432) 49-3459