RGM180 Display Series

Similar documents
RDM172 Remote Display Module QUICK GUIDE

ETC One Plus Network Communicator Installation and Operation Manual

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

Installation and Operation Manual

PM130 PLUS Powermeter Series PM130P/PM130E/PM130EH

DNP3 Communications Protocol

SMART MULTIFUNCTION METER

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

USER MANUAL 2012 V1.1

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

UW Purchase Specification Section

EM920 HIGH PERFORMANCE REVENUE SOCKET METER CUTTING EDGE POWER QUALITY ANALYZER FAST TRANSIENT & FAULT RECORDER

PM135 Powermeter Series PM135P/PM135E/PM135EH

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Digital Multifunction Meters. Digital Multifunction Meters

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

PM180 INSTALLATION MANUAL. PM180 Series SUBSTATION AUTOMATION UNIT. BG0521 Rev. A4

ETC II Network Communicator Installation and Operation Manual

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

Three-Phase Power Quality Analyzer PowerPad Model 3945

Technical Specifications. Multi Function Meter

power quality Models 8230 & 8220

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Series PM170 Powermeters

Technical Specifications. Dual Source Energy Meter (EB / DG)

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Multifunction Transducer MT440

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Installation and Operation Manual

Electronic Submeter with Advanced WiFi Ethernet Capability

ezpac TM SA300 POWER QUALITY ANALYZER FAULT RECORDER SEQUENCE OF EVENTS PROTECTION, CONTROL & ALARM FUNCTIONS REVENUE GRADE METER

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

INTEGRA DIGITAL METERING SYSTEMS

PM180 INSTALLATION MANUAL. PM180 Series SUBSTATION AUTOMATION UNIT. BG0521 Rev. A7

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

SUBJECT TO CHANGE WITHOUT NOTICE

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Technical Specificaions. kwh Energy Meter

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO1250D CT MODBUS MID Three phase four wire energy meter.

EnCell Battery Cell Monitor

EM6400 series Multi-Function meters

ЦЕНОВА ЛИСТА УРЕДИ ЗА ЕНЕРГИЕН МЕНИДЖМЪНТ

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

EM133 Multifunction Meter

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

What s in the Box? REAR VIEW SAFETY

C.A 6165 Appliance multitester

PowerSmart Socket POWER QUALITY METER

PRO2DM DIN rail single phase two wire energy meter

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

i-meter EM Series & i-meter MF Series Installation and User Manual

Electrical Measurements & Energy meter

Source-Transfer Application Guide

PowerLogic ION7300 Series

Technical Specifications. Dual Source kwh Energy Meter

DIRIS Digiware Measurement and monitoring system for electrical installations

Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B A) MEASURING EQUIPMENT

Multilin EPM 4600 Metering Solution

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

Troubleshooting. S&C IntelliCap Plus Automatic Capacitor Control. Table of Contents. Instruction Sheet

PowerLogic ION7550 / ION7650 Hardware Lockable Meter

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

EnerSure Installation Guide

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

THREE-PHASE POWER QUALITY ANALYZER

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

PMC 530 Series Advanced Multifunction Meter

PowerPad III Model 8435

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

Ceiec Electric Technology

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual

WM20. Power analyzer for three-phase systems. Benefits. Description

Energy Management Solution

Merging unit ENMU. Manual

SOLARIMMERSION IV Advanced Installation Manual v1.9

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

CEM-C30 INSTRUCTION MANUAL (M017B A)

DIRIS A-30 Multifunction power metering & monitoring device - PMD

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Transcription:

Quick Start Guide RGM180 Display Series BG0509 REV.A2

RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or parts from date of dispatch from the distributor. In all cases, this warranty is valid for 36 months from the date of production. This warranty is on a return to factory basis. The manufacturer does not accept liability for any damage caused by instrument malfunction. The manufacturer accepts no responsibility for the suitability of the instrument to the application for which it was purchased. Failure to install, set up or operate the instrument according to the instructions herein will void the warranty. Only a duly authorized representative of the manufacturer may open your instrument. The unit should only be opened in a fully anti-static environment. Failure to do so may damage the electronic components and will void the warranty. The greatest care has been taken to manufacture and calibrate your instrument. However, these instructions do not cover all possible contingencies that may arise during installation, operation or maintenance, and all details and variations of this equipment are not covered by these instructions. For additional information regarding installation, operation or maintenance of this instrument, contact the manufacturer or your local representative or distributor. WARNING Read the instructions in this manual before performing installation, and take note of the following precautions: Ensure that all incoming AC power and other power sources are turned OFF before performing any work on the instrument. Failure to do so may result in serious or even fatal injury and/or equipment damage. Before connecting the instrument to the power source, check the labels on the back of the instrument to ensure that your instrument is equipped with the appropriate power supply voltage, input voltages and currents. Under no circumstances should the instrument be connected to a power source if it is damaged. To prevent potential fire or shock hazard, do not expose the instrument to rain or moisture. The secondary of an external current transformer must never be allowed to be open circuit when the primary is energized. An open circuit can cause high voltages, possibly resulting in equipment damage, fire and even serious or fatal injury. Ensure that the current transformer wiring is secured using an external strain relief to reduce mechanical strain on the screw terminals, if necessary. Only qualified personnel familiar with the instrument and its associated electrical equipment must perform setup procedures. Do not open the instrument under any circumstances when it is connected to a power source. Do not use the instrument for primary protection functions where failure of the device can cause fire, injury or death. The instrument can only be used for secondary protection if needed. Read this manual thoroughly before connecting the device to the current carrying circuits. During operation of the device, hazardous voltages are present on input terminals. Failure to observe precautions can result in serious or even fatal injury or damage to equipment. All trademarks are property of their respective owners. April 2012 Copyright 2003-2007 SATEC Ltd. BG0509 REV. A2 2

RGM180 QUICKSTART General The RGM180 series provides a user-friendly interface to monitor and configure SATEC devices. The RGM180 series includes two models: - Local Graphic Display RGM180-G1: the RGM180 communicates with a single host processor expertmeter SATEC device, using an RS-485 interface. It is powered directly from the device. - Network Graphic Display RGM180-G3: the RGM180 communicates with multiple host processor expertmeter SATEC devices (up to 32), using a 10/100Base T Ethernet or RS-485 interface. It is powered by Power over Ethernet (PoE) and/or an external AC/DC adaptor. Installation 1. Interface Description 1. LED: Red (Wh)/Green (Ethernet Link). 2. IR Communication port (for PM180 only) 3. USB Communication port 4. RS485 Communication port and PM17x/PM180 display connector 5. Ethernet Communication port (RGM180-G3 only) 6. Display & Touchscreen. Note: this document prepared for the following devices: RGM180-G1 & RGM180-G3. BG0509 REV. A2 3

RGM180 QUICKSTART 2. Connection Configurations 2.1 PM17x / RPM17x Figure 1: PM17x connection Figure 2: RPM17x Connection BG0509 REV. A2 4

RGM180 QUICKSTART 2.2 ezpac Connection Figure 3: ezpac Connection 2.3 EM720 Connection Figure 4: EM720 Connection BG0509 REV. A2 5

RGM180 QUICKSTART 2.4 PM130 PLUS Connection Figure 5 2.5 EM133 Connection Figure 6: EM133 Connection BG0509 REV. A2 6

RGM180 QUICKSTART 2.6 Ethernet Connection 2.6.1. Regular Ethernet connection Figure 7:Regular Ethernet Connection 2.6.2. PoE Ethernet Connection Figure 8: PoE Ethernet Connection BG0509 REV. A2 7

RGM180 QUICKSTART 2.7 Mechanical Installation Figure 9: Instrument Dimensions BG0509 REV. A2 8

2.8 RGM180 Panel Mount Installation Figure 10: Panel Mount Installation BG0509 REV. A2 9

Operation 1. Connection Connecting to a Meter The RGM runs a self-test prior to connection. The screen will display Connecting.; when connected, Voltage measurement data will be displayed. The screen is touch activated. To display the Main Menu, press MENU 3 times. The Main Menu allows you to: - Select the data group you wish to be displayed (see Section 6); - Conduct display and instrument setups (see Sections 2 and 3). Connecting to the RGM The device allows configuration through the USB or Ethernet at Modbus address 99. 2. Display Setup Press on Display Setup from the Main Menu. The Display Setup menu will appear. BG0509 REV. A2 10

Display Definitions Press Display to set Brightness, Standby Mode and Language: After setting these options, press Save and then close the window by pressing on the X in the top right corner. Screen Calibration Press Calibration to calibrate the display touch screen sensor: Follow the instructions on the screen to calibrate the display. A message will appear indicating if input values are out of range. Press OK to return to Display Setup menu. Network Setup Press Network to define the network connection: Press on the IP Address number to define the address; input the correct IP address (or press Clear to input a new address) and press OK to save or Cancel to restore the previous address. Define or change the Subnet Mask number and Default Gateway in the same manner. DHCP Press the setting (Off or On) to change, then press OK to save. Press X to close the window and return to the Display setup menu. BG0509 REV. A2 11

Serial Port Settings Press Serial to define the serial port settings: Set the Baud rate, Data format, Port direction and response time in the same manner as in the Network Setup. Press X to close the window and return to the Display setup menu. Factory Settings Press Factory to view the factory-set definition of the RGM. It is not recommended to change these settings. Press MENU to return to the Main Menu. BG0509 REV. A2 12

3. Instrument Setup The RGM connects to up to 32 devices. Each device has its own instrument setup definition. Press Instrument Setup to define Wiring Setup and Demand Setup, to adjust the Time, to Reset measurement parameters and to define Communication parameters. Wiring Setup Press Wiring Setup to define the Wiring Mode, CT primary and Nominal Frequency. Press on the value of the desired parameter and enter the correct value. Press Receive to complete the definition, then close the window using the X in the upper right corner. Demand Setup Power demand parameters can be defined on this screen, used in the same fashion as the Wiring Setup. Time Adjustment Use this screen to set the date and time. Press OK when completed. Press OK on the Operation successfully completed message. Reset Setup Use this screen to reset parameters or clear logs. You will be asked after each operation if you are sure you want to perform the reset. BG0509 REV. A2 13

Communications Communications parameters can be set in the same fashion as the Wiring and Demand Setups. Press MENU to return to the Main Menu. BG0509 REV. A2 14

4. Data Display From the Main Menu, press RT Measure to display the Select Data Menu. The Select Data Menu allows you to choose from the four data groups: Real Time Measurements, Harmonics, Energy, and the Logs (Event Log). To display Real Time Measurements, press on Real Time. 4.1 Real Time Measurements Press on the desired data item to display the data. Continue to press NEXT to progress through the data in this group: Voltage: RMS, minimum, maximum and maximum demands Current: RMS, minimum, maximum and maximum demands Power: Total, minimum, maximum, maximum demands, power per phase Auxiliary power: Total, minimum, maximum Phasor and waveform graphs This screen can be reached at any point from any of the real time measurement screens by pressing on MENU from those screens. Note: From this screen, press MENU to display the Select Data menu; press NEXT to bring up the next data group: Harmonic Data (see 4.2). Press Volts L-L RMS to display the screen at right. Press on L-N at the bottom of the screen to view Line to Neutral voltage; press on Sec to display Line to Line Secondary voltage. Press NEXT to proceed to the next data item. BG0509 REV. A2 15

To maneuver between the data items displayed, press PREV or NEXT. At the display of voltage maximum demand, press NEXT to display Current data. Current (Amps) The next four screens display: Currents (Amps) Minimum currents Maximum currents Maximum Demand currents Press NEXT to display Power data. Power The next five screens display: Total Power: kw, kvar, kva, PF Total Power Minimum Total Power Maximum Power Demands: Maximum, Present and Predicted Power per phase Press NEXT to display Auxiliary power data. Auxiliary Power The next three screens display: Auxiliary power Minimum auxiliary power Maximum auxiliary power Press NEXT to display the phasor graph. BG0509 REV. A2 16

Phasor The phasor is a graphical display of phase angles for voltage and current per phase. The phases are color coded for easy reading of the graph. Press NEXT to display the Waveform graph. Waveform The waveform is a real time graphical display. Use the sliding bar on the right to view different waveforms. The icons at the top are (from left to right): - Channel selection - Zoom - View previous or next section of the graph - View waveform properties Press MENU to close this screen. Closing will appear, after which you will be back to the Real Time Measurement Data Menu (see 4.1). From the Real Time Measurement Data screen, press MENU to display the Select Data menu; press NEXT to display the Harmonic Data Menu (see 4.2). BG0509 REV. A2 17

4.2 Harmonic Data Menu This screen presents the Harmonic data group. This includes the following data: Individual harmonics, for each phase: Voltage and current Voltage THD (Total Harmonic Distortion) Current THD Press on the desired data item to view that data. Continue to press NEXT to progress through the data in this group. Note: From this screen, press MENU to display the Select Data Menu menu; press NEXT to display the next data group: Energy Data (see 4.3). Press PREV to return to the Real Time Measurement Data Menu (see 4.1). Individual Harmonics These screens work differently from the Real Time Measurement Data screens you will always need to press MENU to return to the screen shown above and then select the next item you want to view. Each harmonic spectrum can be viewed in graph or tabular form, as shown below. The table expresses the harmonic distortion as a percentage. To view the full table, use the scroll bar on the right. Press on V1 to display the Voltage Harmonic Spectrum (displayed per phase) graph: Press on the table icon at the bottom of the screen to view the Voltage Harmonic Spectrum table. View Current Harmonic Spectrum (per phase) in the same way, by pressing on I1 on the Harmonic Data screen above. BG0509 REV. A2 18

Total Harmonic Distortion These screens work the same as the Real Time Measurement Data screens press NEXT to proceed to the next data item, or PREV to return to the previous data screen. Voltage THD per phase Total Minimum Maximum Maximum Demands Current THD per phase Total Minimum Maximum Maximum Demands Press MENU to return to the Harmonic Data group screen. Press NEXT to proceed to the Energy Data Menu (see 4.3). 4.3 Energy Data This screen presents the Energy data group, consisting of the following data: Energy import: kwh, kvarh, kvah Energy export: kwh, kvarh Net energy Press on the desired data item to view that data. Press NEXT or PREV to see next or preceding data item. Press MENU to return to Energy Data Menu. BG0509 REV. A2 19

Press MENU to return to Select Data Menu; Press Logs to view Log Selection screen (only Event Log is available). 4.4 Log Selection Press Event Log to define and view the log. When you start the time, the Log will download to the display. To order the data, first define the start time. Press on the gray area to insert the time definition. Press OK. Press OK again to commence log downloading. The log will appear. Use the scroll bars at bottom and right to view the full log. To re-start the log, press READ to again define the start time. Press MENU to return to Log Selection Menu. Press MENU again to return to Select Data Menu. Reminder: In the data screens, pressing PREV or NEXT will move you to the previous/next data item within the data group you are currently displaying. You can move from one data group to another. For example, if you are on the Harmonic data display, press PREV to move to Real Time data display; or NEXT to move to Energy data display. To display the Logs, you must return to the Select Data Menu. BG0509 REV. A2 20

5. Meter Selection Labels The label name assigned to a device will appear in the lower left of the screen. The user may change these label names (the actual device being displayed will appear at the top of the screen in parentheses). Meter Selection To change the connection to a different device, press on the label name in the lower left of the screen (in this screen, it is PM172). The Meter Selection screen will appear. Press on the address of the desired meter. Press OK on the Connection established box. Data display will begin. To change the label name or address of a device, press on Setup. The Connection Manager screen will appear. Press on the label name or address you wish to change. Note: In most cases, excluding standalone or ethernet connections, there is no need to change the address or IP. Connecting to an external device requires the definition of MODBUS and/or IP addresses. To perform display setup from this menu, press RGM Setup. See Section 2 for Display Setup instructions. BG0509 REV. A2 21

6. Troubleshooting - If screen does not respond to touch perform screen calibration (see Section 2, Display Setup). - If the display does not connect to the remote meter make sure that the Modbus and/or IP address specified in the Connection Manager (see Section 5) match the remote meter address. - If the display does not connect through the Ethernet connection make sure that the installed IP address is set correctly (see Section 2, Display Setup > Network Setup). You may also need to contact your system administrator to obtain a legal address in a specific network. BG0509 REV. A2 22

Technical Specification Communication ports COM1 IR Communication port PM180 device Only Optional Optical Communication port Max. Baud rate Protocols Isolation 19.200 kb/s Modbus or DNP3.0 2500 V AC @ 1 mn COM2 Serial Communication port Device COM port basic RS-485 Max. Baud rate 115.2 to 480 kb/s Isolation RS-485 Maximum length cable Protocols Connection 4000 V AC @ 1 mn 1000m Modbus RTU DB-15 ETHERNET Multiple device Communication port RGM180-G3 only 10/100Base-T Basic Built-in network communication port with PoE ability Wired LAN communication port with auto-negotiation IEEE 802.3 Ethernet port Baud rate Protocols ETH port Isolation 10/100 Mb/s Modbus/TCP 1.5 KVAC @ 1mn ETH connector Standard RJ-45 USB Built-in USB Communication port DISPLAY Panel DISPLAY Non-volatile memory Basic - Device (default) USB communication port USB port Baud rate Protocols USB device port Isolation (Remote display) USB device port Isolation (Local display) USB connector DISPLAY Panel Panel Display Touch-Panel LCD graphic display, 1 Wh pulse led, IR port and USB Device/Host connector Type A Full speed Device 12 Mb/s size 5.7 resolution Type Outline dimensions Active area Modbus RTU/ASCII and DNP3.0 1500 KVAC @ 1mn 4000 KVAC @ 1mn USB type A, vertical mount, straight 320 x 240 dots TFT color with Touch Panel 131mm (W) x 102mm (H) x 14.5mm (D) 115.2mm (W) x 86.4mm (H) Operating temperature -20 C - +70 C Storage temperature -30 C - +80 C For energy and tariff registers logging, EV-PQ-DATA- WV log Basic 256MB BG0509 REV. A2 23

Power supply 12VDC Device PS standard 24VDC - Device PS option (PM180 Aux. PS) 48VDC PoE option Low DC power supply Rated Input Dielectric withstand insulation Power Consumption Rated Input Dielectric withstand insulation Power Consumption Rated Input Dielectric withstand insulation Power Consumption 10.8 13.2V DC 4000 V DC @ 1mn 2W 9.5 24V DC 3000 V DC @ 1mn 2W 37 58V DC 1500 V DC @ 1mn 2W All models Temperature limit range Detachable Terminals for wires size Header pitch PoE connection 3 x 2.5 up to 6 mm 2 7.5 mm RJ45 Operational temperature -30 C to 70 C LCD Operational temperature -20 C to 70 C Storage temperature -30 C to 80 C BG0509 REV. A2 24