DOC:General.bse

Similar documents
General Introduction - System description - Hardware configuration Hardware Installation OAM programming description

Notification TransTel Communications Incorporated

TDS Enterprise Class Communication System. A High-Performance Telephone Communication System for Midsize Up to Large Enterprises 64 TO1280 PORTS

CONTENT. C. RECEIVING CALLS... 9 C.01 Answer... 9 C.02 Automatic Answer-Intercom... 9 C.03 Call Pickup... 9 C.04 Doorphone (Optional)...

Notification Notification is hereby given that TransTel Communications, Inc. reserves the right to modify, change, update or revise this document

System Administrator s Manual Arista Systems Corporation

1.7 Useful Features. Time (Day/Night/Lunch) Service. Confirming the current mode (with a display PT only) 1-74 Operations

KX-TDE600 Pure IP-PBX. System Capacity. Telephone

KX-TDE600 Pure IP-PBX. System Capacity. Total Number of Extensions. Extensions (MPR) Extensions (Free Slot)

Intelligent Hybrid System. - Product Overview -

Advanced KX-TES824 KX-TEM824

Advanced KX-TES824 KX-TEM824

KX-TD816-7 KX-TD1232-7

Description. Paging to an external pager.

System Highlights. System Capacity. Special System Points. Calling from the outside (Direct Inward System Access) System Expansion.

KX-TA824. Advanced Hybrid Telephone System

15 BUTTON HANDSET USER GUIDE

Quick Reference Guide For Partner ACS R6 System Programming

An Advanced & Efficient solution to make your Business Communication easier

Advanced Hybrid Systems KX-TEA308 KX-TES824

AV SERIES USER GUIDE FOR CORD & CORDLESS TYPE TELEPHONE EXTENSIONS. Aristel Networks DECEMBER SLT User s Guide Issued December 2001 Page 1

Features Guide. Digital Super Hybrid System. Model No. KX-TD500

Emerald ICE Index Prompt and Database Programming. June 10, 20 04

GS Tower,679 Yoksam-dong,Kangnam-gu,Seoul, ,Korea

Sales Guide KX-TES824 KX-TEM824. Advanced Hybrid System

Quick Reference Guide For Partner ACS R4 System Programming

U M. ser. anual Please Read this manual before using the Electronic Modular Switching System. Model KX-T206E. Electronic Modular Switching System

VISIONULTRA The Office PBX

PANASONIC COMMUNICATION SYSTEMS ADVANCED HYBRID WIRED/WIRELESS TELEPHONE SYSTEM, ADVANCED HYBRID

Features Guide KX-TD816JT

BiG BUSinESS performance At An AffoRdABLE price

Digital Super Hybrid System KX-TD500

Panasonic KX-TA1232. Programming Guide. Advanced Hybrid System. Panasonic Telephone Systems. Phone:

System 24 System 48 Suite 64

1.4 Receiving Calls. Receiving Calls Operations. PT and SLT. or INTERCOM

CONTENTS. BT Versatility Owner's Manual

Strata CIX40 IP Communication Solutions For Small Business

KX-T7700 series. Smart-Looking Tel. Bringing a Sleek New Form to C

Quick Reference Guide. Feature Access Codes. Version CN The flexible way to communicate

DS-2100B KEYSET QUICK REFERENCE GUIDE

SPECIAL NOTICES. Use of Call Recorder, Voice Mail Record, and Station Monitor

Comdial ExecuTech System 2000 LCD User s Guide

DIGITAL TELEPHONE USER GUIDE

USER MANUEL OF MT26 EXCHANGES

CONNECTING YOUR BUSINESS WITH TOMORROW. KX-TA624 The advanced hybrid system

ANALOGUE TELEPHONE USER GUIDE

BT Versatility Owners Manual

Telephone User Guide NEC SV9100

Easy to use Affordable to own Grows as you grow

Customize Your Communication Solution...

Advanced Hybrid System. User Manual. Panasonic KX-TA1232. Model No. Please read this manual before using the Advanced Hybrid System.

U M. ser. anual Please Read this manual before using the Electronic Modular Switching System. Model KX-T206E. Electronic Modular Switching System

Standard Telephone User Guide (For KSU Software Versions K24UT 1.XXX & higher.)

SX-200 SX-200. Features. The Features You Need for Your Business. System Specifications: Physical Characteristics. Electrical Characteristics

Samsung HX System User Guide

To: All Panasonic TDA Dealers and Distributors Date: 2/27/2007 Subject: KX-TDA100/200 Version 3.2 Release

LED Indications. Lamp Status

Digital Super Hybrid System KX-TD208E Added and Changed Features for Operating Instructions

OVERVIEW Description of Systems Primary System Features Key Telephones & Accessories Configuration Expansion

DIGITAL TELEPHONE USER GUIDE

TrueCom. Building Communications Systems 5110-Series Controllers. UL Listed. Features. Operation. Description

Terminal User Guide. Hymax Service Contact Information

SAMSUNG DCS SINGLE LINE TELEPHONE USER GUIDE

CONNECTION ELECTRONICS LTD.

Intelligence in business communications

SAMSUNG. OfficeServ. Single Line Telephone. User Guide. Enterprise IP Solutions

Connect V6 Hybrid IP PBX. Owners Manual

-60. Intelligence in business communications

Executive set and Executive set with display. User guide /E Issue 1

KX-NS700. PT Programming Manual. Hybrid IP-PBX. Model No.

Four-Line Intercom/ Speakerphone 954

User Operation Guide TABLE OF CONTENTS

eircom advantage 4800 eircom advantage 1500 System Introduction

Speakerphone set and Display Speakerphone set. User guide /F Issue 1

DIGITAL SUPER HYBRID SYSTEM. Features Guide. Model No. KX-TD500. Please read this manual before connecting the Digital Super Hybrid System.

SAMSUNG HANDSET USER GUIDE FOR DS-5007S / DS-5014S / DS-5038S / DS-5014D / DS-5021D ITP-5107 / ITP-5114D / ITP5121D

KX-TA824. Advanced Hybrid Telephone System. b u s i n e s s

DX-1S DIGITAL PABX Installation Manual

NORSTAR 3X8 SOFTWARE FEATURES

Xen Topaz Features & Specifications Manual

OPERATING MANUAL 308/616/824/832/1264 ULTRA/COMPACT/SFX SERIES INTRODUCTION. The operational manual has been described in two parts.

CONNECTING YOUR BUSINESS

Digital Telephone System. Speakerphone and Monitor Telephone Station User s Guide

SYSTEM ADMINISTRATION AND SPECIAL FEATURES GUIDE

NEC INFRONTIA ISDN BUSINESS COMMUNICATION SYSTEM

Comdial Digital Telephone System LCD Speakerphone System Reference Guide

32 Telephone User Guide

The SL2100 Quick Install Guide: Terminals Type A (4w)

STANDARD TELEPHONE USER GUIDE

Xen IPK II DIGITAL TELEPHONE User Guide

Inter-Tel 3000 Feature Phones

Operating & Programming Manual PBX Model: COX-308S / 416S / 432S

The SL2100 Quick Install Guide: Terminals Type B (2w)

DV-96 INTRODUCTION. System Installation Manual

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011

--Electronic-Telephone --User-Guide--

USER GUIDE FOR 50 or 70 Series Keyphone Table of Contents

DS-5000 Series. Keysets. Quick Reference Guide

DCS-816. System Administration and Special Features Guide

Industry Standard Telephone (IST) Station User s Guide. DXP, DXP Plus, and FX Digital Telephone Systems

Transcription:

(C) AUTO TELECOM 2000

DOC:General.bse 07-07-1998 THIS MANUAL WAS WRITTEN FOR SOFTWARE VERSION I00r(B1-408), CX8-I03o (BX8) & MS-I01s9 (BX320). WHILE ALL CARE HAS BEEN TAKEN TO ENSURE ACCURACY IT RESTS WITH THE INSTALLER TO ENSURE THAT THE FUNCTIONS PERFORM AS TO THE CUSTOMERS REQUIREMENTS. THE POLICY OF AUTO TELECOM IS ONE OF CONTINUAL IMPROVEMENT AND LATER VERSIONS OF HARDWARE AND SOFTWARE MAY CONTAIN ENHANCEMENTS TO THE OPERATION OR FUNCTIONS OF THE HYBREX. AUTO TELECOM DOES NOT AUTOMATICALLY PROVIDE LATER HARDWARE OR SOFTWARE VERSIONS TO ENHANCE FEATURES OR OPERATION AND A CHARGE MAY BE INCURRED FOR UPGRADES. Written by Greg Morrison - Technical Manager

AUTO TELECOM AUSTRALIA C O N T E N T S... 1 System Specifications... 2 General Specifications... 2 Electrical Specifications... 3 Mechanical Specifications... 5 Environmental Specifications... 6 Features... 7 System Features... 7 Station Features... 8 Optional Features... 8 Parts & Peripheral... 9 System Modules... 9 Optional Interface Cards... 9 Type of Phones... 11 Peripheral Devices... 11 Peripheral Software Packages... 11 Spare Parts... 11 Configurations... 12 Installation Capability... 14

: The B Series consist of 3 models The B1-408, BX8 and BX320. They use an IAPX8088 microprocessor in the Central Processing Unit for distributed control, and "Space Division Matrix" for network switching. They work with proprietary Functional Key Telephones (AK1-21/AK1-22/AK1-33) and (KPU 61/KPU62/KPU63), Single Line Telephones, or Optional Equipment (Doorphone, Door Open Switch, Fax Machine, Digital Voice Service, Radio/Tape Player -- External Music Source and sensor). They feature the following advantages: Economy and Efficiency! A maximum of 4/8/40 CO lines and 8/24/248 Extensions can be accommodated. This allows a wide variety of system applications.! Extensions can include industry standard Single Line Telephones or Keyphones.! Versatile programming and options for ease of selection and expanded service. Easy Installation! The Key Service Unit's small size takes little space for installation.! Initial default system data base for quick programming.! Quick Connectors for easy installation on B1 and BX8. Easy Maintenance! Solid-state design minimizes problems and daily maintenance or inspection. Easy Expansion! Various Optional Interface Cards for future expansion. Key Telephone Features! 32-character LCD Display (optional) shows:. Time. Last number dialed. Dialed telephone number. The status of operation/function. Speed dial number. Input data during system data entry! 4/8 volume levels can be adjusted by Keypad.! Distinctive Ring for each key telephone on AK series.! Flexible Function Key Assignment to customize individual telephones.! Help List for System and station programming.! Dual-Color LED s to indicate the status of trunks.! And many other features.. Message waiting.. System alarm.. Toll restriction.. Call accounting.. Text messaging.. Conference call.. Morning call, etc. 1 HYBREX B SERIES - GENERAL DESCRIPTION

General Specifications SYSTEM CAPACITY B1-408: ( : 208 408 ( CO/PABX Lines : 2 4 ( Key Telephones (Maximum) : 8 8 ( Single Line Phones(Maximum) : 8 8 ( Control Relay : 1 1 ( External Input Sensor : 1 1 ( Intercom Paths (Local) : 3 3 ( Doorphone : 1 1 ( External Music : 1 1 SYSTEM CAPACITY BX8: ( :408 416 424 808 816 824 ( CO/PABX Lines : 4 4 4 8 8 8 ( Key Telephones (Maximum) : 8 16 24 8 16 24 ( Single Line Phones(Maximum) : 8 16 24 8 16 24 ( Power Failure Phone : 1 1 1 2 2 2 ( Fax Monitor : 1 1 1 2 2 2 ( Control Relay : 1 1 1 2 2 2 ( External Input Sensor : 1 2 3 1 2 3 ( Intercom Paths (Local) : 6 ( Doorphone : 2 ( External Paging : 1 ( External Music : 2 ( Speed dial B1-408 and BX8 : Total 600 sets for Private/Common Speed Dial. Private Speed Dial: 20 sets per station(max.) Common Speed Dial: 600 sets (Max.) SYSTEM CAPACITY BX320: ( CO/PABX/ISDN Lines: 0 to 40 ( Key Telephones: 0 to 248 ( Single Line Phones: 0 to 248 ( Control Relay: 0 to 12 ( External Input Sensor: 0 to 8 ( Intercom Paths (Local): 6 to 38 ( Doorphone: 2 ( External Paging: 1 ( External Music: 2 ( Speed dial BX320 : Total 600 sets for Private/Common Speed Dial. Private Speed Dial: 20 sets per station(max.) Common Speed Dial: 600 sets (Max.) To achieve the maximum capacity and features some optional equipment may be required. HYBREX B SERIES - GENERAL DESCRIPTION 2

Electrical Specifications CONTROL SYSTEM: SWITCHING METHOD: Stored Program CPU: 8 /16 bits CPU SDM (Space Division Matrix) B1-408 POWER REQUIREMENTS: ( Input 100-120 V AC, (50/60Hz) 0.9 AMPS 200-270 V AC, (50/60Hz) 0.45 AMPS Dedicated AC line and a good earth ground for power supply. POWER FAILURE: ( System operation for 120 minutes (full load) or for 4-5 hours (normal load) by installing batteries (two x 12 V DC batteries 6.5 AH each). POWER DISSIPATION: ( Common Equipment Unit... (idle) 21 W (full) 60 W BX8 POWER REQUIREMENTS: ( Input: 205-265 V AC, (50/60Hz) 0.45 AMPS Dedicated AC line and a good earth ground for power supply. POWER FAILURE: ( System operation for 60 minutes (full load) or for 2-3 hours (normal load) by installing batteries (two 12 V DC batteries 6.5 AH). POWER DISSIPATION: ( Common Equipment Unit... (idle) 27 W BX320 POWER REQUIREMENTS: ( Input 200-265V AC, (50/60Hz) 1.5 AMPS Dedicated AC line with a 3 wire connection to provide a good earth ground for power supply and CO line protection.. POWER FAILURE: ( System operation for 30 minutes (full load) or for 1 hours (normal load) by installing batteries (two 12 V DC batteries 6.5 AH). POWER DISSIPATION: ( Common Equipment Unit... (idle) 46.2 W 3 HYBREX B SERIES - GENERAL DESCRIPTION

( Each Telephone: AK1-21/AK1-22/AK1-33 max. 2.8W Single Line Phone 1.25 W DIALING: ( Outward :Dial Pulse - 10 pps (Pulses Per Second), DTMF ( Internal :Dial Pulse - 10 pps (Pulses Per Second) / DTMF / Digital MAXIMUM LOOP RESISTANCE/IMPEDANCE: ( Key TelephoneLess than 40 ohms 26 AWG (0.4 mm)... 150 m ( Single Line telephone Less than 800 ohms 26 AWG (0.4 mm)... 2000 m ( Doorphone Less than 40 ohms ( Music Source Input Impedance : 600 ohms Maximum Input : 0.775 VRMS INTERNAL RELAY CONTACTS: Type: SPDT Rating: 3 AMP, 110VAC/220VAC Function: Door Switch, Music on Hold, etc CABLE REQUIREMENTS: ( CO/PABX Line: Twisted 1 Pair (2 wires) ( Key Telephone: Twisted 2 Pairs (4 wires) ( Doorphone: Twisted 1 Pair (2 wires) ( Door Switch: Twisted 1 Pair (2 wires) ( External Music Source: Twisted 1 Pair (2 wires) ( Single Line Telephone: Twisted 1 Pair (2 wires) HYBREX B SERIES - GENERAL DESCRIPTION 4

Mechanical Specifications ( Cabinet Dimensions B1-408 233mm W x 76mm D x 290mm H 9.17" 2.99" 11.4" ( Weights... 2.3 Kg (Configuration: 2 x 8) 5.0 lbs ( Cabinet Dimensions BX8 392mm W x 90mm D x 527 mm H 15.43" 3.54" 20.75" ( Weights... 11.8 Kg (Configuration: 4 x 8) 26.02 lbs 5 HYBREX B SERIES - GENERAL DESCRIPTION

( Cabinet Dimensions BX320 380mm H x 290mm D x 620 mm W 14.96" 11.42" 24.41" ( Weight... 17 Kg (Configuration: CBM with PSU) 37.4 lbs Environmental Specifications - All Systems OPERATING CONDITIONS: STORAGE CONDITIONS: Temperature 0E to 45E C -40E to 66E C (32E to 113E F) (-40E to 150E F) Humidity 10 to 95% relative 10 to 95% relative non-condensing non-condensing HYBREX B SERIES - GENERAL DESCRIPTION 6

7 HYBREX B SERIES - GENERAL DESCRIPTION

Features: System Features: ( Alarm - System ( Attendant Console Assignment ( Automatic Call Distribution ( Automatic Line Access ( Battery Charge Circuit ( Daytime/Night Time Weekly Schedule ( Day/Night Mode Manual/Automatic Switch ( Dial Mode Selection(DP/DTMF) ( Easy Installation and Operation ( Flash Time - Programmable ( Flexible Expansion ( Flexible Ringing Asssignment ( Forced Account Code Assignment ( Security Code ( SLT Message Waiting Type ( SLT HOLD Operation ( SLT Calling Proof Capability ( SLT Busy Remind Tone ( SLT Programming Digit ( System Speed Dial and Personal Speed Dial ( System Data & Time Setting ( System Resetting ( System Time-Reminding Service ( Toll Restriction ( Trunk Administration ( Hold Recall ( Host PABX Access ( Hot line ( Intercom Dialling Restriction ( Link Maintenance ( Message Waiting ( Music On Hold ( Night Transfer ( Name for CO Line ( On Call Programming ( Password For DISA, System, Toll, and Others ( Pause Stored for Speed Dial/Redial ( Preventing Illegal Dialing (Quick Dialer) HYBREX B SERIES - GENERAL DESCRIPTION 8

Station Features: ( Absent Message ( Access to System Programming ( Account Code Capability ( Alarm - Station ( Answer ( Answer Call Waiting ( Automatic Call Back (Camp-On) ( Automatic Answer-Intercom ( Automatic Line Access ( Automatic Redial ( Call Waiting ( Call Transfer ( Call Forwarding (Follow Me) ( Calling Doorphone ( Camp On ( Conference ( Day Mode (Console) ( Dial Access to Attendant ( Direct Call Pickup ( Directory Dial for Intercom ( Directory Dial for Speed Dial ( Do Not Disturb (DND) ( Duration Time Display ( Executive Override (Barge-In) ( Flash (Open Loop Timed Flash) ( Handsfree ( Intercom ( Last Number Redial ( Lock Up/Unlock Extensions ( Ring Frequency Selection ( Saved Number Redial ( Speed Dialing ( Store Speed Dial/DSS Number ( Text Message ( Toll Restriction Override (Forced Account Code) ( Trunk Queuing ( Volume Controls ( Zone Paging (Internal) Optional Features: ( Direct Inward System Access (DISA) ( Doorphone ( Door Switch ( Dual Port ( External Music Source ( Relay Control ( RS232 ( Sensor/Door Open Indication ( Station Message Detail Record (SMDR) ( System Data Print Out ( VSC for DISA ( Music On Hold ( Night Mode (Console) ( One Touch Dialing ( Outward Dialing ( Paging/Meet-Me Page ( Privacy Release ( Programmable Key (DSS Key) ( Pulse/Tone Conversion 9 HYBREX B SERIES - GENERAL DESCRIPTION

System Modules - B1-408 B1-208K B1-208H2 B1-208H8 B1-TKC B1-SLC/2 B1-SLC/8 B1-RGU Key Service Unit (2 Trunks and 8 Key Telephone Ports) Key Service Unit (2 Trunks and 6 Key Telephone Ports, 2 Hybrid Ports) Key Service Unit (2 Trunks and 8 Hybrid Ports) Expanded Trunk Card (2 Trunks) Hybrid Station Interface Card (2 Hybrid Ports) Hybrid Station Interface Card (8 Hybrid Ports) Ring Generator Unit Optional Interface Cards -B1-408 B1-VSC B1-MSC B1-MSC-R B1-CKC Voice Processing Card (1 Channel) - Attached on B1-MBU Relay/Sensor/External Music Interface/Door Phone Interface RS232/Relay/Sensor/Door Phone Interface/External Music Interface Calendar/Clock Card/RS232 System Modules - BX8 BX408 B2-TKU B2-HSU88 B2-HSU80 Key Service Unit (4 Trunks and 8 Hybrid Ports) Trunk Interface Unit (4 Trunks) Hybrid Station Interface Unit (8 Hybrid Ports) Station Interface Unit (8 Key Phones) Optional Interface Cards - BX8 B2-VPC B2-RSC B2-RPC MDC50 MDC12 Voice Processing Card (1 Channel-8 sections-60 secs) - Mounted on MBU RS-232 Interface Card - Mounted on MBU Remote Programming Card - Mounted on MBU Meter Pulse Detector / 50 Hz - Mounted on B2-TKU Meter Pulse Detector / 12K Hz - Mounted on B2-TKU HYBREX B SERIES - GENERAL DESCRIPTION 10

System Modules - BX320 B4-CBM B4-MPU B4-IPU B4-TKU B3-STU B3-SLU Cabinet for BX-320, with Motherboard and B3-PSU Main Processing Unit of BX-320 Interface Processing Unit of BX-320 Trunk Unit (Loop Start) - 4 CO Lines Station Interface Unit - 8 Key Telephones Single Line Phone Unit - 8 Single Line Telephones Optional Interface Cards - BX320 B4-EMC B2-RSC B2-RPC B3-VSU B3-SIU-A B3-SIC-A MPD50 MDC12 WP5011 Expansion Memory Card (128KB) - Attached on B4-MPU RS232 Interface Card - Attached on B4-MPU/B4-IPU Remote Programming Card - Attached on B4-MPU Voice Service Unit (4 Channels) ISDN System Unit 4 S/T Interface ISDN S/T Interface Expansion Card 4 ports Meter Pulse Detection Unit 50 Hz - Mounted on B3-TKU Meter Pulse Detection unit 12 KHz - Mounted on B3-TKU Expansion Cable for Connecting BX320 Expansion Cabinets (2 Required) 11 HYBREX B SERIES - GENERAL DESCRIPTION

Type of Phones - All Systems AK1-21 AK1-22 AK1-23 AK1-33 KPU61 KPU61H KPU62 KPU63 DSS60B LCD Phone with Handsfree/16 Dual Color DSS/9 Programmable Function Keys Handsfree Phone with 16 Dual Color DSS/9 Programmable Function Keys Standard Phone with 16 Dual Color DSS/9 Programmable Function Keys Standard Phone with 4 Dual Color DSS/6 Programmable Function Keys Executive Phone with LCD Display & 25 DSS Keys As Above With Headset Interface Hands Free Phone with 25 DSS Buttons Standard Phone with 25 DSS Buttons DSS with Dual Color LED'S (60 keys) BX8 and BX320 Only Peripheral Software Packages SMBX SMBX320 BX8 System Manager BX320 System Manager Peripheral Devices - All Systems DPU05 BBOX1 Door Phone - 2 Wires Battery Box with Battery Spare Parts B1-408 B1-PWU Power Supply Board of B1-408 B1-MBU Mother Board of B1-408 HYBREX B SERIES - GENERAL DESCRIPTION 12

Spare Parts - BX8 B2-PWU B2-MBU B2-DFU B2-BAC BX8 Power Supply Board BX8 Mother Board DTMF Generator/Decoder Board - Mounted on B2-MBU Bi-Directional Amplifier Module - Mounted on B2-TKU Spare Parts - BX320 B3-PWU B4-DGC B4-MBU B3-BAC Power Supply Unit For BX-320 DTMF Generation Card - attached on B4-IPU Mother Board Unit of BX-320 Bi-Directional Amplifier Card - attached on B3-TKU Configuration B1-408: MODEL NO. DESCRIPTION 208K Power Unit (B1-PWU x 1) Mother Board Unit (B1-MBU x 1) Trunk Unit (B1-TKU x 1) Service Unit 208H2 Power Unit (B1-PWU x 1) Ring Generator Unit (B1-RGU x 1) Mother Board Unit (B1-MBU x 1) Trunk Unit (B1-TKU x 1) Hybrid Station Card (B1-SLC/2 x 1) Note: 208H8 Power Unit (B1-PWU x 1) Ring Generator Unit (B1-RGU x 1) Mother Board Unit (B1-MBU x 1) Trunk Unit (B1-TKU x 1) Hybrid Station Card (B1-SLC/8 x 1) The user can add an Expanded Trunk Card(B1-TKC) to the service unit to get the additional two 13 HYBREX B SERIES - GENERAL DESCRIPTION

trunk interfaces. Configuration BX8: MODEL NO. DESCRIPTION 408 Power Unit (B2-PWU x 1) Mother Board Unit (B2-MBU x 1) Trunk Unit (B2-TKU x 1) Hybrid Station Unit (B2-HSU x 1) 416 Power Unit (B2-PWU x 1) Mother Board Unit (B2-MBU x 1) Trunk Unit (B2-TKU x 1) Hybrid Station Unit (B2-HSU x 2) 424 Power Unit (B2-PWU x 1) Mother Board Unit (B2-MBU x 1) Trunk Unit (B2-TKU x 1) Hybrid Station Unit (B2-HSU x 3) 808 Power Unit (B2-PWU x 1) Mother Board Unit (B2-MBU x 1) Trunk Unit (B2-TKU x 2) Hybrid Station Unit (B2-HSU x 1) 816 Power Unit (B2-PWU x 1) Mother Board Unit (B2-MBU x 1) Trunk Unit (B2-TKU x 2) Hybrid Station Unit (B2-HSU x 2) 824 Power Unit (B2-PWU x 1) Mother Board Unit (B2-MBU x 1) Trunk Unit (B2-TKU x 2) Hybrid Station Unit (B2-HSU x 3) HYBREX B SERIES - GENERAL DESCRIPTION 14

Installation Capability: B1-408 BX8 15 HYBREX B SERIES - GENERAL DESCRIPTION

HYBREX B SERIES - GENERAL DESCRIPTION 16