SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

Similar documents
Programming and Installation Manual

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

ES-600 Ozone Controller Operation Manual

OZONE SWITCH Model OS-6. OS-6 Features

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

SFY Functional Safety Frequency-to-DC Transmitter with Display

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Quick Start Guide MC-III TM Flow Analyzer

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

1875 Smart Calibrator. Instruction Manual

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

TPE 1464 Series Pressure Transducer

I/O SIGNAL CONDITIONER

LAUREL ELECTRONICS, INC.

SWTD-1000 Speed Switch / Transmitter Operating Manual

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Global Water globalw.com. Global Water. Instrumentation, Inc.

Pulse Input Adapters (Part # S-UCC/D-M006) for use with HOBO H21 and H22 Series Data Loggers

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Hybrid AC Driver [GCNC-1110]

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

MTS-2000 USER S MANUAL

INDEX. INTRODUCTION PAGE DESCRIPTION KEP Company Overview 3 A brief history of our company.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

USER'S MANUAL DCL-650

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

Ave. Edmonton, Alberta, Canada T6E 5C5 Phone: Fax: web:

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

High Voltage DC Meter

TOXALERT MODEL AIR 2000

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

+GF+ SIGNET ph/orp Transmitter Instructions

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

E:COUNT LT MODEL MCR-09 SPECIFICATIONS & INSTALLATION REFERENCE

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Photoelectric Sensor

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

SUPERtrol-I LE Flow Computer

Instruction Manual IUC-79-FTF 0-10 VDC. Thresholds: ON: TP1=3V OFF: TP2=1V ON: TP1= OFF: TP2= 100 microsec. Not Installed

LKAT2 OEM. Bi-Directional High Current Measurement with Rectifier Protection. Key Features. Description. Application

LCI User Manual mantracourt.com

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Powered Roller Controller for DeviceNet

Process displays For current and voltage

D15CC55UNVD K/KS. UNV DALI Dimming LED Driver 1500mA Constant Current Output Class 2, 55W Output DALI Dimming to 1% Performance.

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

AC/DC Current Probe Model SL201

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Simplified information where and how you want it.

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

Family of Water Cut Analyzers

AC/DC Current Probe Model SL206 USER MANUAL

PMDX-170 Slotted Optical Sensor

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

915-BATRT-M. Installation and Operating Instructions /06

Trident and Trident X2 Digital Process and Temperature Panel Meter

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Global Water Instrumentation, Inc.

Photoelectric Sensor

Model CD-AW. Infrared Environmental CO2 Sensor. Operator's manual

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

7511 / / / 711 / / 731 / Preset 27

OPERATING INSTRUCTIONS

RTD SAMPLER OPERATOR S MANUAL

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Displays Transducers. Displays and transducers

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

MTP INSTRUCTION MANUAL

Model FP-100 General Specification

6220 Ethernet-Based Voltage Measurement Module

Transcription:

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions http://www.kep.com KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724 800-631-2165 732-935-1320 Fax: 732-935-9344 990180 11/10/09

Contents Description... 1 Specifications... 1 Dimensions:... 2 SHPFI-M-0... 2 SHPFI-M-2... 2 SHPFI-M-3... 2 Theory Of Operation... 3 Flow rate equation... 3 20 Point Linearization Option... 3 Wiring... 3 Typical Wiring... 3 Flow total equation:... 3 Getting Started... 4 Installing the setup program for the SHPFI... 4 Step 1 - Electrical Connections... 4 Step 2 - PC Setup Software... 4 Step 3 - Basic Setup... 5 Step 3a - Rate Setup... 6 Step 3b - Totalizer Setup... 7 Step 4 - Setup of the Flow Sensors K-Factor... 8 Step 4a - Average K-Factor Setup... 8 Step 4b - Linearization Table Setup... 9 Step-5 - Pulse Output Setup... 10 Step-6 Analog Output Setup...11 Step 7 - Printing Setup Information... 12 Step-8 - Download Configuration to SHPFI... 13 Step 9 - Save Configuration File... 14 Step 10 - Viewing Computed Rate and Total... 15 Operation... 16 Analog Output Calibration... 17 Decoding Part Number:... 18 Warranty... 18

SPECIFICATIONS Description The SHPFI-M is a smart frequency to current converter and also a frequency to frequency pulse scaler. It is intended to be used with flow meters and similar devices who generate a pulse signal either from a magnetic pickup or a contact closure whose frequency is related to flow rate and where each pulse represents a quantity of flow. The SHPFI-M also contains a linearization function commonly required by flow meters to improve their accuracy. The flow rate and total are computed within the SHPFI-M and the 4-20mA analog output and the high level scaled pulse output are generated from these computed values. The SHPFI-M is programmed using a special setup program from a PC. A special programming cable called the BSAC1 is also required. These items are purchased separately. The computed Rate and Total may also be viewed on your PC using these special cables. Specifications Power: LOOP POWERED Voltage: 8.5 to 30 VDC Protection: Reverse Polarity Protection on Current Loop Loop Burden: 8.5V maximum Computation: Rate Computation 5 Digits (99999), updates 8X per second Time base: /SEC, /MIN, /HR/DAY Min. Input Frequency: 0.01 Hz to 10 Hz (selectable delay of 0.1 to 99.9 seconds) Selectable Rate Damping Pulse Output of computed total: The pulse output advances with the least significant digit of the computed totalizer or decimal multiples there of (see Pulse scale divider). Type: Isolated photomos relay Max. voltage (off state): 30 VDC Current (on state): 100mA Pulse Duration: Selectable 0.5, 0.25, 0.125, 0.0625 seconds Pulse Scale divider (Pulscale): User selectable, 1, 10, 100 or OFF ACCURACY: 0.01% Computed Rate, ±1 least significant digit of computed rate Temperature Drift: 50 ppm/ C Worst Case ENVIRONMENTAL: OPERATING TEMPERATURE -4 F (-20 C) to + 158 F (70 C) Extended Temp: -22 F (-30 C) to + 158 F (70 C) HUMIDITY 0-90% Noncondensing MOUNTING STYLES: 0- OEM- OEM option 2- Wall Mount - NEMA 4X Enclosure 3- Explosion Proof - Class I, Division I, Groups B, C & D Class II, Division I, Groups E, F & G NOTE: Meter mounting kits available (consult Factory) INPUTS: MAGNETIC PICKUP INPUT Frequency Range: 0 to 3500 Hz Trigger Sensitivity: 10 mv p-p (nominal) Over Voltage Protected: ± 30 VDC OPTO-ISOLATED DC PULSE INPUT High (logic 1): 4-30 VDC Low (logic 0): Less Than 1 VDC Minimum Current:.5 ma Hysteresis: 0.4 VDC Frequency Range: 0 to 5 khz Min. Pulse Width: 0.1 msec CONTACT CLOSURE INPUT (contact closure to common) Internal Pullup Resistor: 100 KΩ to +3.6 VDC High (logic 1): Open or 4-30 VDC Low (logic 0): Less Than.5 VDC Internal Switch Debounce Filter: 0 to 40 Hz (others on request) K-FACTOR Range: 0.001 to 99999999 Decimal Point Locations: XXXX.XXXX to XXXXXXXX 20 Point Linearization This feature allows the user to enter 20 different frequencies with 20 different corresponding K-Factors to linearize non linear signals. ANALOG OUTPUT: Type: 4-20 ma follows computed rate display, Two wire hookup Accuracy: 0.025% Full Scale at 20 C Temperature Drift: 50 ppm/ C Typical Reverse Polarity Protected Update Rate: 8 times/second Communications ACCESSORY: RS232 Serial Setup Software This accessory enables you to access a variety of process parameters through serial communications. PC compatible communications software is included with this cable. With this software and a Serial Adapter Cable (BSAC1) you will be able to setup the unit through your PC. 1

Dimensions: SHPFI-M-0 OEM Mount (Mounting option 0): 2.0 2.4 1.25 1.4 SHPFI-M-2 NEMA4 Wall Mount (Mounting option 2): SHPFI-M-3 Explosion Proof Enclosure (Mounting option 3): 3.15 (80.1) 0.315 (8) 2.5 (63.5) ø1.77 (45) ø0.315 (8) 1.97 (50) 0.413 (10.5) 5.12 (130.1) 4.47 (113.5) 0.875 dia. conduit entry for 1/2 hub fitting 1.125 dia. conduit entry for 3/4 hub fitting 2

THEORY OF OPERATION Flow rate equation: Flow total equation: Flow Rate Indication = Input Frequency FAC x Time Scaler Where Time Scaler is equal to: 1 for rate per second read out 60 for rate per minute read out 3600 for rate per hour read out 86400 for rate per day read out Flow Total = Sum of Input Pulses FAC 20 Point Linearization Option: A 20 point linearization table is used to construct a curve describing the relationship of K-Factor and input frequency. The measured input frequency is used to access the table. A linear interpolation of adjacent point pairs is used to arrive at the K-Factor at that input frequency. The flow rate and total are then computed based upon the K-Factor for that measurement sample. NOTE: For best performance and resolution choose as many decimal places as possible in the K-Factor. Example: Enter a K-Factor of 1 as 1.000. WIRING Several typical applications of the SHPFI are shown below. Please observe that the various pulse inputs and power options may be intermixed in many ways to solve common applications. The isolated pulse output may be freely used so long as proper polarity is observed. Caution: When 4-20 ma loop option is provided, the power wiring to the loop power option should always be to terminals (+) 12 and (-) 11. Caution: The magnetic pickup input and contact closure input require isolated sensors for proper operation. Accidental connections to earth may result in erroneous operation of the analog output and/or excessive current flow. Caution: Accidental connections from circuit common (3 or 6) to earth or terminal (11) may result in erroneous operation of the analog output and/or excessive current flow. Typical Wiring CONTACT INPUT / ANALOG & PULSE OUTPUT / LOOP POWERED MAG INPUT / 4-20 ma LOOP POWERED 123456 24 VDC - Power + Supply - Strip Chart Recorder + 121110 9 8 7 4-20mA (+) 12 4-20mA (-) 11 Opto Input (+) 10 Opto Input (-) 9 Opto Out (+) 8 Opto Out (-) 7 6 5 4 3 2 1 1 Mag Input 1 2 Mag Input 2 3 Shield/Common 4 Not Used 5 Contact Input 6 Common Flowmeter with Switch Closure Output 24 VDC - Power + Supply - Strip Chart Recorder + 121110 9 8 7 6 5 4 3 2 1 4-20mA (+) 12 1 Mag Input 1 4-20mA (-) 11 2 Mag Input 2 Opto Input (+) 10 3 Shield/Common Opto Input (-) 9 4 Not Used Opto Out (+) 8 5 Contact Input Opto Out (-) 7 6 Common Turbine Meter with Mag Pickup 3

Getting Started Installing the setup program for the SHPFI The following is an over view of the process used to program the SHPFI-M. Step 1 - Electrical Connections Connecting the Power Supply and BSAC1 to the SHPFI as shown in the figure. Apply 24 Vdc terminal 12(+) and terminal 11 (-). Connect the BSCA1 to the RS232 Port on your PC. Turn 24 Vdc Power On. Step 2 - PC Setup Software Launch the PC Setup Program and Select the SHPFI's template 4

Step 3 - Basic Setup Select the Setup Folder and click on the item labeled Setup Indicators. Choose the SHPFI. Next choose the time base and units of measure to be used in the SHPFI. 5

Step 3a - Rate Setup Setup of the internal rate calculation is done on the Rate tab of the Setup Indicators. The internal rate is computed to up to 5 significant figures with a user selectable decimal; point position. Choose the decimal point position that will result in the flowrate being computed to the maximum precision while not exceeding 5 digits. The delay is the maximum time in seconds between pulses that you wish to wait before the SHPFI decides the flow rate should be treated as 0. The Rate Averaging is a number related to the amount of filtering of computed rate. A value of 0 means no filtering. A value of 9 means maximum filtering. 6

Step 3b - Totalizer Setup The internal totalizer is computed to 8 digits. The pulse output is driven by the least significant digits of the total. Setup the internal totalizer decimal point to correspond to the resolution expected of the pulse output. 7

Step 4 - Setup of the Flow Sensors K-Factor The SHPFI supports the use of either a constant K-Factor for the flow sensor or a linearization table. Begin by choosing the meter type you wish to use in the SHPFI. Step 4a - Average K-Factor Setup If you have decided that your sensor can be treated as just an average K-Factor then choose the decimal point and the K-Factor for the sensor. Click OK when done. 8

Step 4b - Linearization Table Setup If you have decided that your sensor should be treated as a linearization table then enter the frequency/k-factor point pairs in ascending order of frequency. Click OK when done. 9

Step-5 - Pulse Output Setup Setup of the scaled pulse output is entered on the Setup/Output/Pulse pop up. Choose the Pulse Divider and Pulse Width required by the application. 10

Step-6 Analog Output Setup Setup of the Current Output is entered on the Setup/Output/Current pop up. Enter the low scale and full scale you desire. Click OK when done. 11

Step 7 - Printing Setup Information A copy of the setup can be printed for your records on the File Tab by clicking the PRINT setup control. A sample will pop up, then press PRINT to generate the print out via your PC's default printer. Click Close when done. 12

Step-8 - Download Configuration to SHPFI Configuring your communication settings so you can download the configuration into the SHPFI is done by entering the desired value on the Setup control called Serial Usage. You musty select the Port number that corresponds to your RS232 port on your PC. Use the default baud rate of 9600, parity of NONE settings since these are the factory default values used by the SHPFI. Click OK when done. On the file tab press Download, then START to begin the download sequence. Errors in download will be noted in the region provided. 13

Step 9 - Save Configuration File Saving the configuration on your PC is done by pressing the SAVE AS control on the file tab. Use a unique file name for each instrument you configure and organize your folders so they can be located at a future date if needed. 14

Step 10 - Viewing Computed Rate and Total You can view the computed rate and total by selecting the VIEW tab, clicking the items you want to view then clicking start. The values will appear in the region provided as the PC gathers them from the SHPFI. When you are satisfied with the computed value press STOP. The unit is now ready for use. On the file tab press EXIT to end the session. Turn the power supply off. Disconnect the BSAC1 and install the field wiring to the flow sensor and receiving equipment. 15

Operation A suitable pulse producing device or flow meter is wired to one of the three pulse inputs provided on the SHPFI. Only one of these inputs is used in a given application. There are no connections to the two unused pulse inputs. Isolated magnetic pickups may be connected to terminals 1 and 2. Isolated contact closures may be connected to terminals 5 and 6. Any high level, DC pulse type may be connected to terminals 9(-) and 10(+). Power to the unit is provided by the current loop. Once properly wired, the operation of the SHPFI is automatic. The internal flow totalizer is updated 8 times per second. The internal flow total may be cleared using the setup program. The flow rate computation occurs 8 times per second. If the input pulses are not detected within the delay setting (0.1 to 99.9 seconds), an internal flow rate of 0 will be computed. The analog output will be scaled based on the user selected zero and full scale and the computed internal flow rate. The analog output is updated at the same time as the internal rate. The pulse output updates at the same rate as the internal totalizer in accordance with the setup of pulse scaling. 16

Analog Output Calibration CAUTION: Performing the analog output calibration will erase all programming values. Please record all programmed values before beginning the analog output calibration The 4-20 ma has been accurately set to 4.000 and 20.000 ma by the factory. No calibration should be required. The 4-20 ma output may be verified periodically by installing a digital milliamp meter(dmm) in series with the analog output and simulating a full scale or over range flow rate. If the output is out of calibration, perform the following using the Setup Software: Connect a DMM set to read current in series with a power supply (8.5 to 30 volts DC) to TB12 (+) and TB11 ( ). The output should read 4.000 ma (± 0.005). If it does not, Adjust the numbers on the display up or down until the output reads 4.000 ma (± 0.005). The DMM should now read 20.000 ma (± 0.005). If it does not, Adjust the numbers on the display up or down until the output reads 20.000 ma (± 0.005). Click "Close" and the unit will return to the "RUN" mode. 17

Decoding Part Number: Ordering Information EXAMPLE: SHPFI-M 2 HF2 ET Series: Mounting: 0 = OEM 2 = NEMA 4X Box 3 = Explosion Proof Housing Mounting Options for NEMA 4X: H2 = 0.875 Hole for NEMA4X mounting style HF2 = 0.5 Female NPT Hub fitting for NEMA4X mounting style H3 = 1.125 Hole for NEMA4X mounting style HF3 = 3/4 Female NPT Hub fitting for NEMA4X mounting style Additional conduit entry configurations are available, consult factory. Options (Multiple Options Available) ET = Extended Temp.: -22 F to 158 F (-30 C to 70 C) CE** = CE Compliant CSA** = CSA Listed Explosion Proof (planned) IS** = UL Listed IS (planned) Accessories: 115-24 = 115 VAC to 24 VDC power supply BSAC1 = RS232 Serial Adapter Cable (for programming only) with setup software. For use with S1 option. TFM-MK -1 = Turbine Flow meter Mounting Kit for flow meters with a 1 Male NPT riser TFM-MK -3/4 = Turbine Flow meter Mounting Kit for flow meters with a 3/4 Male NPT riser CA-TM-2-18-FL = 18 Turbine Flow meter Cable Assembly Warranty This product (excluding batteries) is warranted against defects in materials and workmanship for a period of two (2) years from the date of shipment to Buyer. The Warranty is limited to repair or replacement of the defective unit at the option of the manufacturer. This warranty is void if the product has been altered, misused, dismantled, or otherwise abused. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 18