The Solid-State Decoupler (SSD)

Similar documents
The Polarization Cell Replacement (PCRH)

OVP2. The Over-Voltage Protector 2 (OVP2) Technical Literature

OVP. The Over-Voltage Protector (OVP) Technical Literature

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Zener Barriers Bulletin 937Z

FLEX Ex Spring Clamp Terminal Base

PanelView Plus/VersaView CE Terminals and Display Modules

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

MANUAL Surge Protectors

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

UL TEST REPORT AND PROCEDURE

Product manual plug, sockets and coupler 16 A.- Z0251

5 Fieldbus Technology

Operating Instructions

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

PI-EX-ME-2NAM/COC-24VDC

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

VariTrans P The Problem The variety of tasks results in a large number of different devices.

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Model Number Structure

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

UL TEST REPORT AND PROCEDURE

CompactLogix Power Supplies Specifications

The Gradient Control Mat (GCM)

An Urgent Bulletin from CSA Group

Technical Information RIA16

DEMKO CERTIFICATE. Certificate No Page 1/3 Date of Issue Certificate Holder. Manufacturer. Production site

Technical Data. Dimensions

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

1510 MOTOR CONTROLLERS

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation & Operation Manual

ICF-1150 Series Quick Installation Guide

Gas Discharge Tube. Indicator Light(2) UL Parallel 1600 V N N / PU-20KS10KTTN. UL Series 1600 V N N 15 A PU-20KD10KTTN

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SITOP in the SIMATIC Design

Inductive sensor BI5-EM18-Y1X-H1141

CompactBlock Guard I/O EtherNet/IP Safety Modules

Conveyor Belt Alignment Switches from IDEM

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Intrinsically Safe Barriers

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Installation Instructions

Operating instructions. Standstill monitor A / / 2011

Thread length (overall length) material

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

MINI MCR-SL-PT100-UI-200

Installation Instructions

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

Chip Immune Inductive Prox E2EZ

Coil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Description. Green. Red. Orange

Series Panel Mounted Control Devices

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Line Impedance Stabilization Network (LISN)

Inductive sensor with analog output BI15-M30-LI-EXI

Installation & Operation Manual

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

User's Guide. Extech AM A AC Analog Clamp Meter

Inductive sensor NI3-EG08K-Y1-H1341

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

Inductive sensor BI1.5-EG08-Y1-H1341

General Specifications

Technical Information Promonitor NRF560

iconverter 2-Module Power Chassis

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

Specifications, Installation, and Operating Instructions

Transcription:

The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction with cathodically protected equipment located in Class I, Division 2 hazardous (classified) locations or ordinary (non- hazardous) locations. The SSD is suitable for: (1) decoupling ground mats, (2) AC voltage mitigation, (3) over-voltage protection of insulated joints and similar structures and equipment, (4) DC isolation and AC grounding of cathodically protected structures and electrical equipment in cathodically protected structures. The SSD can be used in a variety of different applications, each of which requires specific installation guidelines. These installation instructions cover the following common applications and arrangements. Over-voltage protection for insulated joints Decoupling gradient control mats Decoupling cathodically protected structures containing electrical equipment from grounding systems AC mitigation Some applications listed may not apply in some countries due to different codes and practices. If your application is not covered by these installation instruc tions, contact DEI. Technical information for applications is available on the Dairyland website. Installation Instructions These general instructions apply to all applications. For specific installation instructions, refer to the figure numbers that apply to the application as noted on the first page. Mounting Mount the SSD so that the total length of conductor to the connection points will be as short as possible if the SSD is going to be used to provide over-voltage protection from lightning. All conductors have inductance which will cause a significant voltage per unit of conductor length when subject to lightning surge current. To minimize the voltage developed This Unit Model Number: Model Number Chart Blocking Threshold Choose: 2/2 (Standard) 3/1 (Optional) AC Fault Current Choose: 1.2kA 2kA 3.7kA 5kA Terminal Arrangement Add -R for standard terminal arrangement Remove -R for alternate terminal arrangement* Lightning Surge Current Choose 100 for 2kA, 3.7kA, 5kA models Choose 75 for 1.2kA models Certifications The SSD has been tested by Nationally Recognized Testing Laboratories (NRTLs) for compliance to independent standards in its operation, ratings, and construction. Visit our website for Complete Certifications and Listings Safety Grounding UL (United States) and C-UL (Canada) listing for: NFPA 70 (US National Electric Code - NEC), Article 250.2 and 250.4 (A)(5), and C22.1-12, Section 10-500 and 10-806 ANSI C62.11 Blocking Cathodic Protection Current NFPA 70, Article 250.6(E) Hazardous Location Use The SSD has been certified for use in Class I, Division 2, Groups A, B, C, D hazardous locations to: NFPA 70 (U.S. National Electrical Code) sections 500-505 ANSI/ISA 12.12.01-2011 CSA C22.2 No.213-M1987 (R2008) The SSD has been certified to ATEX Directive 94/9/EC and IECEx requirements for use in Zone 2, Group IIC hazardous locations by UL/DEMKO to: EN 60079-0:2012, EN 60079-15:2010, IEC 60079-0: 6th Ed, IEC 60079-15: 4th Ed 3415 Rev D August 2014

between the connection points, install the SSD as close as practical to the required connection points and cut the conductor to the shortest possible length during installation. For most insulated joint applications the SSD can, and should, be installed with less than 8 (200 mm) of conductor. Conductors can develop 1-3 kv/ft. (approx. 3-10 kv/meter) of length due to lightning; hence, for this reason, leads should be kept as short as possible in lightning applications. Conductor length is not critical for limiting voltage due to 50 Hz or 60 Hz current. Mounting Accessories Numerous mounting accessories are available from Dairyland to aid in the proper installation of the PCR. Full details and complete installation instructions are available on the Dairyland website here: Dairyland Accessories. Specific Installation Guidance The Dairyland website contains detailed information on the installation methods specific to a given application. For wiring diagrams and/or application guidance, see Dairyland Applications. Polarity If the SSD purchased has asymmetrical blocking characteristics and it is being connected between a cathodically protected structure and ground, connect the negative terminal of the SSD to the cathodically protected structure and the positive terminal to ground. If being connected between two different cathodically protected systems, attach the negative terminal to the more negative structure and the positive terminal to the less negative structure. A label on the SSD housing shows the polarity of each terminal. Enclosure The standard enclosure is rated IP68 to 2m depth (comparable to NEMA 6P). This enclosure is suitable for submersible applications. Ambient Operating Temperature -45ºC to +65ºC. Field Testing Before installation, the following measurements are suggested to confirm that the steady-state conditions imposed on the SSD will be within its ratings. 1. Measure the open-circuit DC voltage between the SSD connection points with a multimeter. The open-circuit DC voltage measured should be within the DC blocking voltage rating of the model selected (i.e., normally -3.0 V/+1.0 V or +/-2.0 V, unless a custom version has been ordered). 2. Measure the steady-state short-circuit AC-RMS current between the SSD connection points with a clamp-on ammeter. The short-circuit AC-RMS steady-state current measured should be less than the steady-state AC current rating of the SSD model ordered. 3. After installation, the DC voltage across the SSD terminals can be measured to confirm that the expected value of cathodic protection voltage exists, assuming the cathodic protection system is ON. (The voltage measured with a voltmeter will be less than the actual cathodic protection voltage because it is not being measured with respect to a reference cell.) 4. After installation, the steady-state AC current through the SSD conductors can again be be measured. The current measured should be comparable to the value measured prior to installation since the AC impedance of the SSD is negligible (i.e., about 10 milliohms at 60 Hz). 5. To verify correct device operation while in service, measure the pipe to soil voltage using a reference cell. An acceptable CP reading will indirectly indicate correct operation with DC isolation, as device conduction would bond the CP system to ground (or to the other connected structure) and affect the CP reading. While an indirect test, it has proven to be a good indicator of operation. An unacceptable reading may be due to other factors besides the Dairyland device, and if needed perform the following additional tests. 6. An alternative to the above test checks for the presence of direct current leakage through the device. With the CP system ON, clamp a Hall Effect DC measurement unit over one of the device attachment conductors to read direct current, which should be negligible. 7. The definitive test is one performed with the device out of circuit. If the device is in service, disconnect the CP structure attachment conductor (typically at the negative terminal) so that the product is isolated, but first addressing any safety issues such as adding a current-rated bonding jumper between the two connection points, wearing insulating gloves, etc. Note that if the Dairyland device is performing mitigation of induced AC voltage, disconnecting the device will leave the structure as an open circuit, and the induced voltage on the pipeline may rise to high levels. Therefore, take appropriate safety measures before proceeding. Next, momentarily short the device terminals to remove any residual charge that may be on the internal capacitor. Connect a multi-meter, set to the lowest Ohms scale, across the terminals. If the product is functional, the resistance will start at zero ohms and then very slowly increase as the capacitor in the decoupler begins to charge from the multimeter. The test may be discontinued at this point, as charging the capacitor can take up to 10 minutes, and it is only necessary to observe this general response briefly. If the product is failed, the reading will remain fixed and at a very low resistance value, typically a fraction of one Ohm. If any measurements do not produce the expected results, contact Dairyland. General Comments The SSD does not require routine maintenance, but if the cathodic protection voltage level near the SSD is below the normal or expected value, it is suggested that the unit be field tested following procedures available from Dairyland. If a problem is suspected, contact Dairyland for trouble-shooting assistance. If repairs are necessary the unit is to be returned

to Dairyland for diagnosis and repair after requesting a Return Material Authorization (RMA). The SSD is designed to fail as a short-circuit to assure safety grounding at all times if the unit fails due to excessive ac fault current or lightning current beyond rating. ATEX and IECEx Comments The device shall be placed into service in accordance with the ratings and limitations stated in the installation and operating instructions. No ongoing maintenance is required, as the device is designed to be maintenance-free, and is of solid-state construction with no moving, wearing, or serviceable parts. During installation the device should be handled and mounted in a location so that direct impact is minimized. Regular testing of the device is not required. Users who desire to verify the operating condition of the device should refer to the section entitled Field Testing. Observe all safety precautions described, in addition to industry or company safety practices. WARNING: Potential electrostatic charging hazard Plastic enclosures are to be cleaned or wiped only with a damp cloth. Products marked CE, Ex II 3 G are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design and construction of such equipment given in Annex II to the Directive 94/9/EC. This equipment is intended for use in area in which explosive atmospheres caused by gasses, vapors, mists, air or dust mixtures are unlikely to occur, or are likely to occur only infrequently and for short periods. Such locations correspond to Zone 2 classification according to ATEX Directive 94/9/EC. This equipment complies with standards EN 60079-0:2012 and EN 60079-15:2010 per certificate number DEMKO 05 ATEX 0431689X and IEC 60079-0 Ed. 6 and IEC 60079-15 Ed. 4, per certificate number IECEx UL 14.0021X. The Quality Assurance Report is based on ISO/IEC 80079-34: Edition 1 2011-04.

Figure 1 Outline Drawing SSD Outline Drawing (Standard Terminal Arrangement) 304.8 12.0 Negative Bus (-) 279 11.0 25.3 1.0 12.7.5 71.8 2.83 53.7 2.11 89.3 3.52 SLOTS FOR 5/16" OR M8 MOUNTING BOLTS 25.4 1.0 1.0" x 1/8" STAINLESS MOUNTING BRACKET (25.4mm x 3.2mm) 54 2.1.328 25.4 1.00 40.1 1.6 221.8 8.7 0.094"x1.0" BUS (2.4mmx25.4mm)

Figure 2 SSD Outline Drawing (Optional Terminal Arrangement) Slots for 5/16" or M8 Bolt 3.22" (81.8mm) 2.8" (71.1mm) 3.5" (88.9mm) 1.0" x 1/8" Stainless Bracket (25.4mm x 3.2mm) 11.0" (279mm) C L Nameplate 2.1" (53.3mm) 2.12" (53.8mm) Negative Bus (-) Positive Bus (+) 8.7" (221mm) 1.0" (25.4mm) 0.094" x 1.0" Bus (2.4mm x 25.4mm)