REMOTE METER. Model: MT50 INSTRUCTION MANUAL

Similar documents
COM. Warning MATE MICRO. Esc OK. OutBack Mate Micro User s Manual

INSTRUCTION MANUAL. Remote Meter: MT50

SOLAR CHARGE REMOTE. P/No. SC300D 1 1

REMOTE METER USER MANUAL KAMPPTRC

Super Parameter Programmer SPP-01

User Manual for Solar Station Monitor

LCD Display Unit User Manual

Intelligent Solar Charge Controller User s Manual. Please read this manual carefully before you use this product

LCD Display Unit User Manual

ViewStar series. Solar Charge Controller OPERATION MANUAL

MPPT Solar charge controller

SCM030. MPPT Solar System Controller With. DC to DC Booster Input. Installation & Operating Instructions

Model HM-535 Power Supply Installation and Service Instructions

Technical manual for HP8480 Main battery switch with current monitor. + Low power output for rain light. + Battery discharge warning output.

Intelligent Solar Charge Controller. User s Manual. Please read this manual carefully before you use this product.

M2 OLED Temperature Monitor Instructions PN 1841

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Energy Management System. Operation and Installation Manual

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER BATTERY MONITOR

Instructions for use:

3000 Series Instructions Read Instructions Carefully!

Instructions for use:

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Solis Single Phase Inverter

Datalogging Conductivity/ TDS Meter. Instruction Manual

3700 SERIES USER MANUAL

SmartPSB2000L Smart PV Safety Box Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

TRIRON SERIES. Modular MPPT charge controller 12V/24V,10A. Product models TRIRON4210N. Product portfolio

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

Solis Single Phase Inverter

High Efficiency LED Driver DCCP-DPR Series USER MANUAL. This manual offers important information and suggestions with

SHUTTERBOSS VERSION II USER MANUAL

Plasmatronics 9/07/2009 Plasmatronics_Brief.product.summary_Ver.1.4.doc Slide 1

DPM Digital DC Power Meter with Data logging capability. User Manual

ARTiPRO. User Manual. (Model 910 & 920)

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to Installation and Operation of This Product.

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

User Manual. Solar Inverter for Water Pump

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Features: Contents: If you are missing any of the above components please contact Racepak at

Guide Specification for 3G Wireless Battery Monitoring System

PA39085 INSTRUCTION MANUAL

INSTRUCTION MANUAL CONTAINS: MOUNTING DIMENSION: For RVs,Caravans,and boats METER for duo-battery charging solar controller,

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

RS Stock No Instruction Manual RS Input Data Logging Thermometer

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Manual. Meter for BlueSolar DUO 12/24V-20A For RVs, Caravans and boats

Innovative Circuit Technology Ltd.

Supplied Accessories.

Instruction Manual RS-1660

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

Wireless Digital Video Doorbell CL-3684 USER S MANUAL

Model N47KB Energy Monitor with Built-in Timer

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

FG-7000 Digital Force Gauge Operation Manual

INDEX. Network Power Monitor R10 SNMP

DPM-3221 Digital DC Power Meter with data logging capability.

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

FG-3000 Digital Force Gauge Operation Manual

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

PADPULS2 M-BUS Pulse Input Modules

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

USER MANUAL MINI WILDLIFE CAMERA

Barefoot Power Ltd 2013 v1.4

MANUAL PELITT MINI 1

INSTALLATION INSTRUCTIONS

installation quick guide integrated access control & environmental monitoring

Contents 1 Warnings, Cautions, and Notes Description Features... 1

SOLARIMMERSION IV Advanced Installation Manual v1.9

Trend-1 Vibration Data Logger. User Manual

User s manual. Please read carefully this instruction before you use the machine.

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

Air Conditioner. installation manual. imagine the possibilities DB A-02. PIM(Pulse Input Module) MIM-B16N

HuddleCamHD 10X-USB2

RH/Temperature SD Card Datalogger. Instruction Manual

PTDT V Quick Installation & Reference Guide. Ver Battery Management Solutions by. PowerDesigners

Installation & Operation Instructions

Overview DIP switch settings Modular Components. Selecting operating function by DIP switch settings

Please take serious note of the following warnings:

Renewable Energy. Getting Started With the LEGO Energy Meter

FG-3000R Digital Force Gauge Operation Manual

FG-7000L Digital Force Gauge Operation Manual

Visible Light SD Card Datalogger

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

MT-150. RENOGY 150A Peak High Precision Watt Meter and Power Analyzer E. Philadelphia St., Ontario CA Version: 1.

Service Information EEPROM WRITER. Guide for use with EMIT. Software Types Covered: EVO 1 EVO 2

WIRELESS SHUTTERBOSS. User Manual

Owner s Manual Revision 4.01 Option 1

Installation and Operations Manual INVOLAR MAC250 Microinverter

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Transcription:

REMOTE METER Model: MT50 INSTRUCTION MANUAL For use with solar charge controllers PU series, LS series, VS series, PTR series, Tracer MPPT series and other compatible controllers

Remote Meter MT50 Please note that this remote meter (Model MT50) should only be used with solar charge controllers PUxxxxB(P), LSxxxxB(P), VSxxxxBN, Tracer TRxxxxBN(P), PTRxxxxA(N) and other solar charge controller models released in the future if the user manual states that they are compatible with this MT50 remote meter.

Contents 1 Important Safety Instructions... 1 2 General Information... 2 2.1 Features... 2 2.2 Main functions... 3 2.3 Recommendations... 3 3 Installation... 4 4 Product Features... 8 5 Operation... 12 5.1 Buttons... 12 5.2 Main menu... 13 5.3 Real-time monitoring... 14 5.4 Device information... 16 5.5 Test operation... 16 5.6 Control parameters... 17 5.7 Load setting... 21 5.8 Device parameters... 24 5.9 Device password... 25 5.10 Factory reset... 25 5.11 Failure information... 26 5.12 Meter parameters... 27 6 Technical Specifications... 28

1 Important Safety Instructions SAVE THESE INSTRUCTIONS: This manual contains important safety, installation and operating instructions for the remote meter. General safety information Please inspect the MT50 thoroughly after it is delivered. If any damage is seen, please notify the shipping company or our company immediately. A photo of the damage may be helpful. Read all instructions and cautions in the manual before starting the installation. Keep the MT50 away from rain, dust, vibrations, corrosive gas and intense electromagnetic interference. Do not allow water to enter the remote meter. There are no user serviceable parts inside the remote meter. Do not disassemble or attempt to repair it. 1

2 General Information 2.1 Features The new-generation remote display unit MT50 for PU, LS, VS, Tracer, PTR and other compatible controllers is an associated display device which supports both the latest communication protocol and the voltage standard of solar charge controllers. The product has many useful functions: Automatic identification of the type, model and relevant parameter data of various solar charge controllers Real-time display of the operational data and working status of the connection devices in digital, graphical and textual forms by a large-screen multifunctional LCD; Direct, convenient and rapid operation of six navigation function keys; Both data and power flowing on the same lead, no need for external power; Real-time data monitoring and remote load switchover of the controllers, data browse and modification of device parameters, charge control parameters and load control parameters; Real-time display of failure information of the connected devices; Longer communication distance via RS485. 2

2.2 Main functions The main functions of the remote meter are the real-time monitoring of the operational data and working status of the connected solar charge controller, browsing and modification of charge/discharge control parameters, setting of device parameters and load control parameters, the restoration of factory defaults, based on LCD display and functional keys operation. 2.3 Recommendations Please note that MT50 can only be used with PUxxxxB(P), LSxxxxB(P), VSxxxxBN, TracerxxxxBN(P), PTRxxxxA(N) controllers. It is not suitable for dual battery controllers DB series. Confirm that you have a compatible controller before purchase and use of the remote meter. Please do not install MT50 in a location with strong electromagnetic interference or risk of contact with water. 3

3 Installation Frame mount dimensions (mm) 4

Mechanical parameter Overall dimension Parameter 114 x 114 x 32.7 mm Mounting 88.6 x 88.6 mm dimension Terminal Φ4.3 Wall installation steps: Step 1: Locate and drill screw holes based on the frame mounting dimensions of the base, and erect the plastic expansion bolts; Step 2: Use four ST4.2 32 self-tapping screws to fix the frame; Frame mounting 5

Step 3: Use four M4 8 pan head screws to mount MT50 surface onto the frame; Step 4: Mount the four associated screw plugs into the screw holes. Frame mounting 6

Steps of surface mounting: Step 1: Locate and drill screw holes based on the installation size of the remote meter; Step 2: Use four M4 8 cross recessed pan head screws with M4 nuts to mount MT50 Surface onto the panel (or suitable self-tapping screws); Step 3: Mount the four associated screw plugs into the screw holes. Surface mounting Note: Take full consideration of the plugging/unplugging space of the communication cable and the length of the cable during installation to see if they are appropriate. 7

4 Product Features 8

RS485 communication and power interface Rear View Failure indicator Failure indicator flashes in case of failure of the connected device. For failure information please check the solar charge controller manual. 9

Communication indicator Indicate communication status when MT50 is connected to the controller. Display screen User monitoring and operation interface. Buttons The meter buttons include four navigation buttons and two operational buttons. See specific instructions in the Operations section. RJ45 communication and power interface Communication and power supply socket used for connection to a solar charge controller. Note: Please use the communication plug which is marked with MT to connect MT50 Monitoring screen 10

Day and night icons - Night, - Day: The threshold voltage is 1V. Higher than 1V is daytime. Charge current icon The icon moves if there is charge current. Battery icon The estimated battery capacity is shown. Note: When the battery is over discharged, the icon displayed is. Battery status icons - Normal voltage, - Under voltage, - Over discharge. Load current icon The icon moves if there is discharge current. Load status icon - Load On, - Load Off. Note: In Manual Mode, pressing the "OK" button will switch the load status between "ON" and "OFF" 11

5 Operation 5.1 Buttons The buttons are respectively (from left to right) ESC, Left, Up, Down, Right and OK. Use of these navigation buttons can be shown in the schematic operation diagram below: Schematic operation diagram 12

The default entry page is the browse mode. Press the button and input the correct password to enter the modification mode. Use and buttons to move the cursor, while and buttons can be used to modify the parameter values when the cursor has selected the parameter; and buttons can then be used to respectively confirm or cancel the modification of the parameter. 5.2 Main menu Enter the Main Menu by pressing. and buttons are used to move the cursor to select the menu items; and buttons are respectively used to enter or exit the corresponding sections of the menu. 1. Monitoring 2. Device Info. 3. Test Operation 4. Control Para. 5. Load Set 6. Device Para 7. Device PSW. 8. Factory Reset 9. Failure Info. 10. Meter Para. 13

5.3 Real-time monitoring There are 14 pages under real-time monitoring. Please note as below: 17.5V 13.8V 13.8V 15.2A 5.2A 10.0A LS****B Jan-01-2013 02:34:33 Char. Energy Day: 0.00kwh Mon: 0.00kwh Total: 0.00kwh DisCh. Energy Day: 0.00kwh Mon: 0.00kwh Total: 0.00kwh Battery Vol: 0.0V Cur: 0.0A Battery Temp.: 22.4 Max. Vol: 12.7V Min. Vol: 12.7V Battery Charge: NoCharge Energe: Normal Fault: No 14

PV Vol: 0.0V Cur: 0.0A Power: 0.0W PV Sta.: DisConnect Fault: No Char.: PWM/MPPT Controller Temp.: 25.0 Sta.: Normal Load Vol: 0.0v Cur: 0.0A Power: 0.0W Sta.: Fault: Load OFF No Load Mode Information Load Mode Information Operational tips: Move between rows by pressing or buttons. Move along a row by pressing or buttons. 15

5.4 Device information The product model, parameters and SN code of the controllers are displayed below: LS****B LS****B Rate.Vol: 12V SN:0002201301200045 Char.Cur: 10.0A Disc.Cur: 2.6A Operational tips: and buttons are respectively used to turn the browse page upward and downward. 5.5 Test operation Load switch test operation can be conducted on the connected solar charge controller to see if the load output is normal. The test operation does not affect the working settings under the actual load, which means that the solar controller will exit from the test mode when exiting the operational interface of the test. Test Operation LS****B: OFF Operational tips: enter the page and input the correct password; use and buttons to modify the On/Off status values; use and buttons respectively to confirm or cancel the test operation. 16

5.6 Control parameters Browse and modification operations are conducted over the control parameters of the solar charge controller. See the range for parameter modification in the control parameters table, and the section of control parameters in the diagram below: Batt. Type Sealed Batt. AH 200AH Temp Comp.Coeff -3mv/ /2V Rated Voltage 12V Over Volt. Disc 16.0V Charge Limit 15.0V Equalize Time 120min Boost Time 120min Ooer Volt. Rec. 15.0V Eugal. Charge 14.6V Boost Charge 14.4V Float Charge 13.8V Low Volt. Disc 11.1V Discharge Limit 10.6V Under Volt. Rect 12.2V Under Volt. Warn 12.0V Boost Rec. 13.2V Low Volt. Rect. 12.6V 17

Control parameters table Parameters Default Range Battery type Sealed Sealed/Gel/Flooded/User Battery Ah 200Ah 1~9999Ah Temperature compensation coefficient -3mv/ /2V 0~-9mv Rated voltage Auto Auto/12V/24V/36V/48V Battery voltage parameters (Parameters for 12V system at 25, please use x 2 for 24V, x 3 for 36V, and x 4 for 48V system) 18

Battery charging setting Sealed Gel Flooded User Over voltage disconnect voltage 16.0V 16.0V 16.0V 9~17V Charging limit voltage 15.0V 15.0V 15.0V 9~17V Over voltage reconnect voltage 15.0V 15.0V 15.0V 9~17V Equalize charging voltage 14.6V 14.8V 9~17V Boost charging voltage 14.4V 14.2V 14.6V 9~17V Float charging voltage 13.8V 13.8V 13.8V 9~17V Boost reconnect charging voltage 13.2V 13.2V 13.2V 9~17V Low voltage reconnect voltage 12.6V 12.6V 12.6V 9~17V Under voltage warning reconnect voltage 12.2V 12.2V 12.2V 9~17V Under voltage warning voltage 12.0V 12.0V 12.0V 9~17V Low voltage disconnect voltage 11.1V 11.1V 11.1V 9~17V Discharging limit voltage 10.6V 10.6V 10.6V 9~17V Equalize duration 120min 120min 0~180min Boost duration 120min 120min 120min 10~180min. 19

Notes: 1. When the battery type is sealed, gel or flooded, the adjusting range of equalize duration is 0 to180 mins and boost duration is 10 to180 mins. 2. The following rules must be observed when modifying the parameter values for the user battery type (factory default value is the same as sealed type): a) Over Voltage Disconnect Voltage > Charging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage > Boost Reconnect Charging Voltage. b) Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage c) Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage Discharging Limit Voltage. d) Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage Discharging Limit Voltage. e) Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage. NOTE: Please refer to the battery user manual or contact the battery supplier / manufacturer for details on charging voltages and specific requirements. 20

5.7 Load setting The load setting page can be used to set the four load working modes of the connected solar charge controller (Manual, Light on/off, Light on+timer, Time control): Manual Control Light On/off Light On+Timer Time Control Manual Control Default : ON Manual Control Light On/off Light On+Timer Time Control Light On/Off On 05.0V DeT 10M Off 06.0V DeT 10M Manual Control Light On/off Light On+Timer Time Control Light On+Timer On 05.0V DeT 10M Off 06.0V DeT 10M NightTime10H:00M Light On+Timer OnTime1 01H:00M OnTime2 01H:00M Manual Control Light On/off Light On+Timer Time Control Time Control Time1 OnTime 10:00:00 OffTime 19:00:00 Time Control Time2 OnTime 19:00:00 OffTime 19:00:00 21

Manual control Mode On Off Light On/Off Light On voltage (Night threshold) Light Off voltage (Day threshold) Notes Load is on all the time (if the battery has enough charge and no abnormal conditions occur) Load is Off all the time When the input voltage of the solar module is lower than Light On voltage, it automatically turns on the load output (if the battery has enough charge and no abnormal conditions occur) When the input voltage of the solar module is higher than Light Off voltage, it automatically turns off the load output The delay time for load on/off actions. If during this period the Light On/Off voltage threshold criteria are met, a Delay time corresponding load on/off action will happen at the end of this period (the time adjustment range: 0~99 mins) Light On + timer Working time 1 (T1) Working time 2 (T2) Night time Load working period (the load is on), after the light control turns on the load Load working period (the load is on), before the light control is due to turn off the load Total reference night time length ( 3h) to calculate when Working time 2 should start When the working time is set to 0, the load will not work for this period. The real working time of T2 depends on the Night time, and the length of T1 and T2. 22

Time control Working time 1 (T1) Working time 2 (T2) Control the on/off time of load through the real-time clock mode. Second working period (dual timer function of the load) through the real-time clock mode. Working time 1 is the compulsory load working time interval. Working time 2 is optional. 23

5.8 Device parameters The software version information and device data of the solar charge controller can be checked via the page of device parameters. Data like device ID, device LCD backlight time and device clock can be checked and modified. The pages of device parameter are shown below: Device Parameter Ver: V01.00+V02.10 ID: 001 Device Parameter Bklight:60S Jan-01-2013 00:01:39 Note: the bigger the ID value of the connected device, the longer the meter communication identification interval (the maximum interval <6 mins). Type Ver ID Bklight Month-Day-Year H:M:S Notes Solar charger controller software and hardware version numbers. Solar charger controller communication ID numbers. Solar charger controller LCD backlight working time. Solar charger controller internal clock. 24

5.9 Device password The password of the solar charge controller can be modified via the page of device password. The password is a 6-digit figure which is required before entering the modification mode of Control parameter, Load setting, Device parameter, Device password, Factory reset pages. The page of device password in the diagram is shown below: Device PSW OriPsw:xxxxxx NewPsw:xxxxxx Note: the solar charge controller default password is 000000 5.10 Factory reset The default parameter values of the solar charge controller can be restored via the Factory reset page. The Control parameter, Load setting, Charge mode and Device password of the devices will be restored to the factory defaults if Yes is chosen (the factory default password of the devices is 000000 ). Factory Reset Yes No 25

5.11 Failure information The current failure information of the solar charge controller can be checked via the Failure information page (max. 15 failure messages could be displayed). When the failures of solar charge controller are resolved, the corresponding failure information will also be automatically removed. Failure Info 1.Over voltage 2.Over load 3.Short circuit Failure information Load MOS-Short Load Circuit Load O. cur. Input O. cur. RPP Short RPP Break Char.MOS-Short Input O. Cur. Disc.O.O.Ctrl. Ctrler O.Temp. Comm. Timeout Details The MOSFET of the load driver is short. The load circuit is short. The load circuit is over current. PV input current is over rate. The MOSFET of reverse polarity protection is short. The MOSFET of reverse polarity protection is broken. The MOSFET of the charge driver is short. Input current is over rate. Discharge operation is out of control. The controller is over heated. The communication has timed out. 26

5.12 Meter parameters The meter model, software and hardware version, and SN NO. can be checked via the Meter parameter page. Meter functions such as Switch pages timer and Backlight can also be modified. Meter Para. Taye: MT50 Ver: V1.00+V1.00 SN: Meter Para. Sw-Pages:000S Bklight:020S AudiAlam: OFF Note: When the setup is completed, the auto switch page will require ten minutes to take effect. Parameters Default Range Details Sw-Pages 0 0~120 secs Set the timer to automatically switch back to the previous page Bklight 20 0~999 secs LCD backlight time 27

6 Technical Specifications Electrical parameters Self-consumption Backlight ON <23mA Backlight OFF <15mA Mechanical parameters Main meter unit dimensions Frame dimensions Connector type Meter cable length Meter weight Environmental parameters 98 98 mm 114 114 mm RJ45 Standard 5m, Max 50m Simple package: 0.23 Kg Standard package: 0.32 Kg Ambient temperature -20 ~+70 28

Definitions of interface pins Pin No. Definition 1 Power+5~12V input 2 Power+5~12V input 3 RS485-B 4 RS485-B 5 RS485-A 6 RS485-A 7 GND 8 GND Data cable pin definitions 29

Remote meter dimensions (mm) Changes to this manual can be made without prior notice. Version number: v8.0 30

Photonic Universe Ltd E-mail: info@photonicuniverse.com Web: www.photonicuniverse.com Tel.: +44 (0) 203 150 11 11