Digital Clamp Meter User Manual

Similar documents
USER'S MANUAL DCL-650

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Model A Mini AC/DC Clamp Meter. User's Guide

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

AC/DC TRUE RMS CLAMP METER ACM-2036

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Autoranging True RMS Multimeter User Manual

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

OPERATING INSTRUCTION

MTP INSTRUCTION MANUAL

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

Model R5010. TRMS Digital Multimeter. Instruction Manual

Autoranging Mini Multimeter

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

AutoRanging Digital MultiMeter

User's Guide. Digital Multimeter. Model MN42

Extech EX845 True RMS 1000 Amp Clamp Meter with Bluetooth

User's Guide. Extech AM A AC Analog Clamp Meter

Mini Digital Multimeter

User Guide True RMS Multimeter Extech EX205T

True RMS Industrial Multimeter Extech EX530

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Autoranging Multimeter Extech EX503

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Mini Digital Multimeter

Mini Digital Multimeter Model MN15. User's Guide

Industrial Multimeter Extech EX510

True RMS Industrial Multimeter Extech EX520

USER MANUAL. True RMS Multimeter. Extech EX430A

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Autoranging Mini Multimeter Model MN16A

Wireless TRMS Multimeter and Insulation Tester

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Mini Multimeter with Non-Contact Voltage Detector (NCV)

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

Wireless TRMS Multimeter and Insulation Tester

Mini Digital Multimeter

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

True RMS Multimeter with IR Thermometer

Wireless TRMS Multimeter

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Wireless TRMS Multimeter

True RMS Multimeter with IR Thermometer

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40

WARNING CAUTION 1. SAFETY

True RMS Multimeter with IR Thermometer

Insulation Resistance Multimeter CAT III

2 in 1 LAN Tester and Multimeter Model:

TENMA INSTRUCTION MANUAL MULTI-TESTER

ETHOS Auto Ranging Digital Multimeter

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

User s Guide. MultiPro Digital MultiMeter Series With PC Interface. Models: MP510 MP520 MP530

Elma 5800 English usermanual Page 35-49

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Digital Clamp-on Meter Instruction Manual

Model. True RMSmA Clamp Meter. Instruction Manual

DC / AC True RMS Watt Clamp DMM

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

True RMS Digital Bench Multimeter Model:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Digital Multimeter User's Manual

Monarch Instrument 2002 all rights reserved MONARCH INSTRUMENT. True RMS Multimeter. Instruction Manual. Monarch 120

700 Series 200 Amp Clamp Meters

Model 3526-B Digi-Probe Multimeter

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Bench Multimeter. Users Manual

Digital Clamp-on Meter Instruction Manual

Digital Clamp-on Meter Instruction Manual

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

POCKET MULTIMETER Model No: MM18

User s Manual. Mini MultiScope II MODEL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com. TRIPLETT Model 9055

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

7032 Digital-Analog Multimeter

TRIPLETT Model in-1 EnviroMeter with Sound Light, Temperature and Humidity. Instruction Manual /10

AC/DC Current Probe Model SL201

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

User's Guide. Handheld MultiScope. Model

ENGLISH. User manual.

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

Digital Clamp-on Meter Amp Plus. Instruction Manual

Transcription:

Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside.

Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions... 3 5.Meter Description... 4 6.Operation... 7 7.AC/DC Current Measurements... 7 8.AC/DC Voltage Measurements... 8 9.Resistance Measurements... 8 10.Diode and Continuity Measurements... 8 11.Capacitance Measurements... 9 12.Frequency measurements... 9 13.Temperature Measurements... 9 14.Non-Contact AC Voltage Measurements... 10 15.Mode Button... 10 16.Data Hold Button... 10 17.Rel Button... 10 18.Peak Hold... 11 19.Battery Replacement... 11 Page 2

1. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation 2. Safety Notes Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected. Set the function switch OFF when the meter is not in use. 3. Warnings Set function switch to the appropriate position before measuring. When measuring volts do not switch to current/resistance modes. When changing ranges using the selector switch always disconnect the test leads from the circuit under test. Do not exceed the maximum rated input limits. 4. Cautions Compact AC, AC/ Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Remove the battery if the meter is to be stored for long periods. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. 3

Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live". If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Input Limits Function A VDC,VAC Frequency, Resistance, Diode, Continuity, Capacitance Test Temperature ( C/ F) Maximum Input 400A DC/AC 600V DC/AC 250V DC/AC 250V DC/AC 5. Meter Description 1.Current clamp 2.Non-contact AC voltage indicator light 3.Clamp trigger 1 4.Rotary Function swith 5.Data Hold button 6.Back Light button 7.LCD display 2 8.MODE select button 9.PEAK button 3 10.Relative button 11.COM input jack 12.V Ω CAP TEMPHz jack 5 13.Battery Cover 7 8 11 400A 40A C F Hz REL AC/DC TRMS CLAMP METER V Ω Hz COM Temp CAT III 600V 4 6 9 10 12 4 13

1.AC DC AC (alternating current) and DC (direct currrent) 2. Minus sign 3. 4000 count (0 to 3999) measurement reading with 41segments Analog Bargraph 4.AUTO AutoRange mode 5. Relative mode 6. Diode test mode 7. Audible Continuity 8. Data Hold mode 9. C, F, μ,m,v,a,k,m, Ω Units of measure list 11.Hz % Frequency/duty cycle test mode 12. MAX MIN MAX/MIN Hold mode 12. Pmax Pmin Pmax Pmin Hold mode Function AC Current (50/60Hz) DC Current DC Voltage AC Voltage (50/60Hz) Resistance Range & Resolution 40.00 AAC 400.0 AAC 40.00 ADC 400.0 ADC 400.0 mvdc 4.000 VDC 40.00 VDC 400.0 VDC 600.0 VDC 400.0 mvac 4.000 VAC 40.00 VAC 400.0 VAC 600.0 VAC 400.0 Ω 4.000 KΩ 40.00 KΩ 400.0 KΩ 4.000 MΩ 40.00 MΩ Accuracy (% of reading) ±(2.5%+8digits) ±(2.8%+5digits) ±(2.5%+5digits) ±(2.8%+5digits) ± (0.8% + 2 digits) ± (1.5% + 2digits) ±(2%+2digits) ± (1% + 10 digits) ± (1.5% + 5 digits) ± (2.0% + 5 digits) ± (1.0% + 4 digits) ± (1.5% + 2 digits) ± (2.5% + 3 digits) ± (3.5% + 5 digits) 5

40.00nF 400.0nF Capacitance 4.000μF 40.00μF 400.0μF 4mF 10-100kHz Frequency Temp (type-k) (probe accuracy not included) Clamp size Diode Test Continuity Check Low Battery Indication Overrange Indication Measurements Rate Input Impedance Display AC Current AC Voltage bandwidth Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Over voltage Battery Auto OFF Dimensions/Weight 6 Sensitivity:100V(<50Hz); 50V(50 to 400Hz;15V (401Hz to 100kHz) -20 to 760 C -4 to1400 F ± (5.0% reading + 20 digits) ± (3% reading + 5 digits) ± (4.0% reading + 10 digits) ± (5.0% reading + 10 digits) ± (1.5% reading + 2 digits) ± (3%rdg+5 C) ± (3%rdg+9 F) Opening 30mm ( 1.2" ) approx Test current of 0.3mA typical; Open circuit voltage <3V DC typical. Threshold <50 Ω; Test current <0.5mA is displayed OL is displayed 2 per second, nominal 10M Ω (VDC and VAC) 4000 counts LCD 50-60Hz (TRMS AAC) 50-60Hz ( TRMS VAC) 5 to 40 C ( 41 to 104 F) -20 to 60 C (-4 to 140 F) Max 80% up to 31 C ( 87 F) decreasing linearly to 50% at 40 C( 104 F) <80% 2000meters ( 7000ft. ) maximum. Category III 600V One 9V Battery approx. 30 minutes 197x70x40mm/183g

Safety 6. Operation 7. AC/DC Current Measurements Compact AC, AC/ For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Cat. III Notices: Read and understand all warning and precaution statements listed in the safety section of this operation manual prior to using this meter. Set the function select switch to the OFF position when the meter is not in use. Warning: Ensure that the test leads are disconnected from the meter before making current clamp measurements. 1. Set the Function switch to the 400ADC/AC,40ADC/AC range. 2. Select AC or DC with the MODE button. 3. If the range of the measured is not known, select the higher range 3. first then move to the lower range if necessary. 4. Press the trigger to open 3. jaw. Fully enclose one 3. conductor to be measured. 5. In DCA mode, to ensure 3. the reading is correct, 3. please press REL button to 400A 400A 40A 40A 3. clear the reading on LCD C F C F 3. before measurement. The Hz Hz 3. clamp Meter LCD will 3. Display the reading. NO REL AC/DC TRMS CLAMP METER V Ω Hz COM Temp YES REL AC/DC TRMS CLAMP METER V Ω Hz COM Temp CAT III 600V CAT III 600V 7

8. AC/DC Voltage Measurements 1. Insert the black test lead into the negative COM terminal and the 1. red test lead into the positive V terminal. 2. Set the function switch to the V position. 3. Select AC or DC with the MODE button. 4. Connect the test leads in parallel to the circuit under test. 5. Read the voltage measurement on the LCD display. 9. Resistance Measurements 1. Insert the black test lead into the negative COM terminal and the 1. red test lead into the positive terminal. 2. Set the function switch to the Ω position. 3. Touch the test probe tips across the circuit or component under 1. test. It is best to disconnect one side of the device under test so 1. the rest of the circuit will not interfere with the resistance reading. 4. For Resistance tests, read the resistance on the LCD display. 10. Diode and Continuity Measurements 1. Insert the black test lead banana plug into the negative COM jack 1. and the red test lead banana plug into the positive diode jack. 2. Turn the rotary switch to the position. 3. Press the MODE button until appears in the display. 4. Touch the test probes to the diode under test. Forward voltage 1. will indicate 0.4V to 0.7V. Reverse voltage will indicate OL. Shorted 1. devices will indicate near 0mV and an open device will indicate OL 1. in both polarities. 1. For Continuity tests, if the resistance is < 50 Ω, a tone will sound. Red Black Black Forward test Reverse test 8

11. Capacitance Measurements Warning: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords. 1. Set the rotary function switch to the CAP position. 2. Insert the black test lead banana plug into the negative (COM) jack. 1. Insert the red test lead banana plug into the positive (V) jack. 3. Touch the test leads to the capacitor to be tested. 4. Read the capacitance value in the display 12. Frequency measurements 1. Set the rotary function switch to the Hz position. 2. Insert the black lead banana plug into the negative COM jack and 1. the red test lead banana plug into the positive V jack. 3. Touch the test probe tips to the circuit under test. 4. Read the frequency on the display. 13. Temperature Measurements Compact AC, AC/ Warning: To avoid electric shock, disconnect both test probes from any source of voltage before making a temperature measurement. 1. Set the function switch to C F. 2. Insert the Temperature Probe into the negative (COM) and the V 1. jacks, making sure to observe the correct polarity. 3. Touch the Temperature Probe head to the part whose temperature 1. you wish to measure. Keep the probe touching the part under test 1. until the reading stabilizes (about 30 seconds). 4. Read the temperature in the display. The digital reading will indicate 1. the proper decimal point and value. Warning: To avoid electric shock, be sure the thermocouple has been removed before changing to another measurement function 9

14. Non-Contact AC Voltage Measurements Warning: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation. 1. Touch the probe tip to the hot conductor or insert into the hot 1. side of the electrical outlet. 2. If AC voltage is present, the detector light will illuminate. Note: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. Note: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation. 15. Mode Button To select DC/ACV,OHM/ Diode/Continuity/CAP, 16. Data Hold Button To freeze the LCD meter reading, press the data hold button. The data hold button is located on the left side of the meter (top button). While data hold is active, the H display icon appears on the LCD. Press the data hold button again to return to normal operation. 17. Rel Button For DCA and Capacitance Zero & Offset adjustment. 10

18. Peak Hold The Peak Hold function captures the peak AC voltage or current. The meter can capture negative or positive peaks as fast as 1 millisecond in duration. 1. Turn the function switch to the A or V position. 2. Use the MODE button to select AC. 3. Allow time for the display to stabilize. 4. Press and Hold the PEAK button until CAL appears in the display. 1. This procedure will zero the range selected. 5. Press the PEAK button, Pmax will display. 6. The display will update each time a higher positive peak occurs. 7. Press the PEAK button again, Pmin will display. The display will now 1. update and indicate the lowest negative peak. 8. To return to normal operation, press and hold the PEAK button 1. until the Pmin or Pmax indicator switches off. Note: If the Function switch position is changed after a calibration the Peak Hold calibration must be repeated for the new function selected. 19. Battery Replacement 1. Remove the one rear Phillips head screw 2. Open the battery compartment 3. Replace the Requires One 9V battery 4. Re-assemble the meter Compact AC, AC/ 11

Rev.090801