Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

Similar documents
Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

TEK360M series is a fan-less 300W, U-frame, switching power supply with active PFC function for medical application. Rated Output Power.

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Safety Standards. Model Number:

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number:

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number: Unit Weight:

500Watts Medical Single Output

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS /20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K.

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

Constant Voltage Mode

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

Safety Standards. Model Number:

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

60 Watt Medical (MWLT)

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Safety Standards. Model Number:

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

CINT W Triple Output Industrial Series

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Safety Standards. Model Number:

VP ELECTRONIQUE MASSY - Tel

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Safety Standards. Model Number:

Safety Standards. Model Number:

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Safety Standards. Model Number:

SPECIFICATION 全漢企業股份有限公司 R&D CHECK APPROVED REV. JOGE 01. FSP Technology Co.,Ltd. 台灣桃園市建國東路 22 號 TEL: FAX:

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

275 Watt Medical Ultra low profile

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Snaptec Australia Pty. Ltd.

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

FEATURES. Nominal Output Voltage and Current

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Series AM1S-Z 1 Watt DC-DC Converter

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given.

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

12W AC/DC interchangeable Adapter MU012-HA Series

Output Voltage* (nom.)(adjustable)

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

5W AC/DC interchangeable Adapter MU005-HA Series

Safety Standards. Model Number:

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Safety Standards. Model Number:

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

CPS Industrial Power Supply

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Power Factor Model Number Voltage Voltage

Output Voltage* (nom.)(adjustable)

Output Current Input Current Max. capacitive Load

LPS. ME20 20W Single Output External Power Medical Series. Features

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

ME to 30W Single Output External Power Medical Series. Features

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Enclosed Power Supplies

SPECIFICATIONS: PSAK650

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Transcription:

FEATURES 120W medical adapter with active PFC Green power CEC/Energy star group complied Designed to meet medical standard type BF rated Conductive EMI meets CISPR/FCC class B Wall mount mechanical construction possible Optional strain relief kit for tightening the AC power cord Medical standard of IEC 60601-1 2nd and 3rd EN 60601-1 2nd and 3rd and UL 60601-1 1st edition approved RoHS compliant DESCRIPTION: MPM-X12Y series is a signal output, 120W with active PFC adapter for medical system applications. The adapter is designed to meet EN 60601-1 and UL 60601-1 safety standards. SPECIFICATION Input Voltage: 90 ~ 264VAC, Continuous input range Input Frequency: 47 ~ 63Hz Hold-up Time: Min. 16ms; Nominal AC input voltage (115VAC) Input Current: Max. 2A; Nominal AC input voltage (115VAC/230VAC), rated load Inrush Current: Max. 30/60A; Nominal AC input voltage (115VAC/230VAC), one cycle at 25 C Efficiency: Greater than 90%; Rated load, 115VAC, varies with distribution of loads among output. Ripple and Noise: Rated load, 20MHz bandwidth and the each output is connected with a 47µF electrolytic capacitor and a 0.1µF ceramic capacitor Short Circuit Protection: Fully protected against output overload and short circuit. Automatic recovery starts if unit overloads. Earth Leakage Current: Limit of type BF compliant. Worst case leakage is less than 300µA at 264VAC, 63Hz normal condition and 500µA single fault condition Over Voltage Protection: Fully protected against over voltage and the trigger point is: MPM-X123 Min. 15VDC / Max. 17VDC MPM-X124-1 Min. 24VDC / Max. 27VDC MPM-X125 Min. 26.5VDC / Max. 30VDC MPM-X125-1 Min. 37VDC / Max. 41.5VDC Operating Temperature: Min.-20 C / Max. 60 C, rated load and convection cooling, derating from 40-60 C Storage Temperature: Min. -20 C / Max. +85 C Relative Humidity: Min. 10%RH / Max. 90%RH, non-condensing Warranty: 24 months Approvals: IEC 60601-1:1988+A1+A2 - TUV approved IEC 60601-1:2005 - TUV approved EN 60601-1:2006 - TUV approved UL 60601-1, 1st edition, 2006-04-26 - UL approved IEC 60950-1:2005+A1 - TUV approved CAN/CSA-C22.2 No. 601.1-M90, 2005 - cul approved GB 4943-2001 - CCC approved *J60950 (H19) - TUV approved Energy Star CEC: V Level; California Energy Commission s appliance regulations section 1601-1608 of title 20 of the California code of regulations Hi-Pot: 6346VDC, input to output PFC: EN 61000-3-2 - Class A, EN 61000-3-3

SPECIFICATION EMI: EN 60601-1-2:2007 Class B GB 9254-2008 GB 17625.1-2003 EN 61000-3-2:2006+A2:2009 & EN 610003-3:2008 Class D EMS IEC 61000-4-2:2008, 8kV air discharge IEC 61000-4-3:2006+A1:2007+A2:2010, 3V/m IEC 61000-4-4:2004+A1:2010, 2kV line & PE IEC 61000-4-5:2005, L-N:1kV, L/N-PE:2kV IEC 61000-4-6:2008, 3V/m IEC 61000-4-8:2009, 3A/m IEC61000-4-11:2004, Voltage dips > 95%, 0.5 cycle Voltage dips 30%, 5 cycles Voltage dips 60%, 25 cycles Criteria B Voltage interruptions > 95%, 250 cycles Criteria B *: The PSE approval marking on products is by request. Output Voltage / Current Rating Chart: Measured at output power connector Model Output Voltage Min. Output Current Rated Output Wattage Rated Output Current Line Regulation Load Regulation Ripple & Noise p-p Initial Setting Accuracy MPM-X123 +12-13.8V 0A 120W 10-8.6A +/- 1% 3% 120mV 2% MPM-X124-1 +19-20V 0A 120W 6.3-6A +/- 1% 2% 190mV 2% MPM-X125 24V 0A 120W 5A +/- 1% 2% 200mV 2% MPM-X125-1 36V 0A 120W 3.3A +/- 1% 3% 240mV 2% NOTE: 1) Please add suffix G to required model number for optional removing Y capacitor between input ground to output return ground. Connect the input ground directly to output return ground. Please refer to part number coding below. 2) Optional shielded output cable by request, please refer to part number coding below

Part Number Coding MPM X 12 Y Z 1 Z 2 + Z 3 + Z 4 Y Regular Stocking Options 3 +12Vdc 4-1 +19Vdc 5 +24Vdc 3-1 +13.8Vdc 4-2 +20Vdc Z 1 Z 2 Z3 Z4 Regular Stocking 5-1 +36Vdc 52 Straight 4 pin din, pin 1 & 2: V+, pin 3 & 4: V- Options 51 Straight 4 pin din, pin 1 & 3: V-, pin 2 & 4: V+ Regular Stocking Options Regular Stocking 2 1.2m with one ferrite core 3 1.8m with one ferrite core 6 1.2m shielding with one ferrite core 7 1.8m shielding with one ferrite core 0 Full isolated from PRI GND to SEC GND Options G PRI GND connect directly to SEC GND 1) MPM-X123 & MPM-X123-1 can only use output cable length less than or equal 1.2m. 2) Please contact us for availability, lead time and the EMI criteria if you require any of the optional extras. Connector CN1 --- AC Input: CN2 --- DC Output: CN3 --- Output remote sense: 3 Positions Terminal Blocks, European type by request 4 Positions Terminal Blocks, European type by request 2 Positions Pin Assignment CN1 PIN 1. L 2. N 3. GND CN2 PIN 1. V+ 2. V+ 3.V- 4. V- CN3 PIN 1. Remote Sense + 2. Remote Sense FAN (Note 1) PIN 1. + 2. NOTE: 1) The voltage of fan is the same as the output voltage of power supply. 2) The tolerance of height would be +/- 0.5mm if optional cover is fitted (please add suffix C to required model number).

Thermal (Input 90V / 50Hz, output 24Vdc full load, ambient temperature 25 C # Part Temp. S1 D5 73.5 C S2 Q3 76.7 C S3 T1 56.4 C S4 DZ5 85.3 C S5 Q1 57.3 C S6 Q2 82.5 C S7 D2 82.8 C S8 DB1 84.0 C S9 C7 56.6 C S10 C21A 64.1 C S11 C21 54.4 C S12 T2 63.6 C S13 R30 97.7 C Thermal (Input 264V / 50Hz, output 24Vdc full load, ambient temperature 25 C # Part Temp. S1 D5 77.4 C S2 Q3 82.2 C S3 T1 74.3 C S4 DZ5 73.7 C S5 Q1 74.4 C S6 Q2 81.8 C S7 D2 70.1 C S8 DB1 68.1 C S9 C7 55.4 C S10 C21A 66.7 C S11 C21 55.5 C S12 T2 55.0 C

Connector AC Inlet: IEC 6032 inlet C14 DC Output Plug Pin assignment: # Polarity 1 V+ 2 V+ 3 V- 4 V- Paramter Strain relief kit (P/N 747-SWPL-2F) Tighten the AC power cord to the adapter Operating Temperature: Min. -20 C / Max. +85 C, rated load and convection cooling. Derating from 40-60 C Load % Temperature (deg C)

Mechanical Drawings: 175 (L) x 90 (W) x 51.3 (H) mm excluding the output cable Tolerance +/- 4mm R4 R5.00 BARCODE SPEC LABEL Output Cable: Length 1.8m maximum for MPM-X124-1, MPM-125 and MPM-X125-1 Length 1.2m maximum for MPM-X123 Connector: AC input: IEC 60320 inlet / C14 (Class I) DC output plug: 4 pin DIN plug, 180 C

Conduction Line: (Input 230V / 50Hz, output 36Vdc and full load) QP/AV QP/AV Limit Read Total Ant. Cable Other Det. Freq. Level Margin Level Level Factor Factor Factor Factor Mode MHz dbuv db db dbuv db db db db 1 0.154 58.78-7.00 65.78 58.65 0.13 0.10 0.03 0.00 QP 1 0.154 36.69-19.09 55.78 36.56 0.13 0.10 0.03 0.00 AV 2 0.170 55.75-9.21 64.96 55.62 0.13 0.10 0.03 0.00 QP 2 0.170 32.44-22.52 54.96 32.31 0.13 0.10 0.03 0.00 AV 3 0.228 46.14-16.38 62.52 46.01 0.13 0.10 0.03 0.00 QP 3 0.228 22.67-29.85 52.52 22.54 0.13 0.10 0.03 0.00 AV

Conduction Line: (Input 110V / 50Hz, output 36Vdc and full load) QP/AV QP/AV Limit Read Total Ant. Cable Other Det. Freq. Level Margin Level Level Factor Factor Factor Factor Mode MHz dbuv db db dbuv db db db db 1 0.158 49.18-16.39 65.57 49.05 0.13 0.10 0.03 0.00 QP 1 0.158 27.98-27.59 55.57 27.85 0.13 0.10 0.03 0.00 AV 2 0.177 45.05-19.58 64.63 44.92 0.13 0.10 0.03 0.00 QP 2 0.177 23.84-30.79 54.63 23.71 0.13 0.10 0.03 0.00 AV 3 0.548 38.53-17.47 56.00 38.39 0.14 0.10 0.04 0.00 QP 3 0.548 25.58-20.42 46.00 25.44 0.14 0.10 0.04 0.00 AV

Radiation Vertical: (Input 230V / 50Hz, output 36Vdc and full load) QP/AV QP/AV Limit Read Total Ant. Cable Other Table Ant. Det. Freq. Level Margin Level Level Factor Factor Factor Factor Pos. Pos. Mode MHz dbuv db db dbuv db db db db cm 1 40.94 23.97-6.03 30.00 43.80-19.83 12.09 1.39 33.31 223.0 100 QP 2 64.63 25.31-4.69 30.00 52.20-26.89 5.10 1.33 33.32 360.0 100 QP 3 71.72 20.28-9.72 30.00 46.92-26.64 5.36 1.37 33.37 113.0 100 QP 4 116.5 21.75-8.25 30.00 42.50-20.75 11.09 1.67 33.51 62.0 100 QP 5 135.4 23.05-6.95 30.00 44.26-21.21 10.61 1.78 33.60 103.0 100 QP 6 154.0 22.03-7.97 30.00 43.92-21.89 9.84 1.91 33.64 106.0 100 QP

Radiation Vertical: (Input 110V / 60Hz, output 36Vdc and full load) QP/AV QP/AV Limit Read Total Ant. Cable Other Table Ant. Det. Freq. Level Margin Level Level Factor Factor Factor Factor Pos. Pos. Mode MHz dbuv db db dbuv db db db db cm 1 46.64 20.38-9.62 30.00 43.23-22.85 9.18 1.34 33.37 75.0 100 QP 2 64.83 22.01-7.99 30.00 48.90-26.89 5.10 1.33 33.32 12.0 100 QP 3 71.5 19.21-10.79 30.00 45.90-26.69 5.32 1.36 33.37 231.0 100 QP 4 128.3 24.35-5.65 30.00 45.30-20.95 10.93 1.69 33.57 236.0 100 QP 5 139.2 21.88-8.12 30.00 43.20-21.32 10.44 1.85 33.61 255.0 100 QP 6 156.0 22.30-7.70 30.00 44.26-21.96 9.76 1.92 33.64 213.0 100 QP 7 169.2 19.35-10.65 30.00 42.10-22.75 9.09 1.94 33.78 203.0 100 QP

GERMANY Joh.-Friedr.-Boettger-Str. 21 63322 Roedermark Phone +49 6074 69285-0 Fax: +49 6074 69285-10 E-Mail: sales.de@hitekpower.com Revision 10/2013