Configuration DCE TAC-I

Similar documents
Configuration Mita WP3000

Configuration KK-Controller

USER MANUAL FOR GS100/GS1003G

Configuration DanWind - HEMI

The universal SCADA client User manual

Bluetooth TO Serial CONVERTER E-P132-B

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

AMS COCKPIT USERS GUIDE. AMS Cockpit Version 1.1 USERS GUIDE

Magnetek Material Handling IMPULSE LINK 4.1 WDS

Select a Data Communication Interface

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Four-Faith Smart Power Technology Co., Ltd. F1103 GPRS MODEM USER MANUAL

ICP PANEL-TEC PEX3000 II

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Serial Interface. Upgrading Firmware

Bluetooth V4.1 BLE RS-232 Serial Adapter Model: BLE-232B Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232C

zigb232 & zigb485 User Guide User Guide TANGENT TECHNOLABS

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

FSA-CU Configuration Utility Programming Guide

VNS2000 Server Software

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

IntesisBox Modbus Server - Honeywell XLS 80

DPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda

F1403 WCDMA/HSDPA/HSUPA MODEM USER MANUAL. Four-Faith Smart Power Technology Co., Ltd.

Configuration Instructions for icap with DOS Captivator

Modbus Server SIEMENS Algorex (printer port)

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

TelePACE Studio Ladder Logic Training Manual

IMPULSE LINK 4.1 WDS. Instruction Manual. WDS Configurator. April 2018 Part Number: R4 Copyright 2018 Magnetek

Firmware Release ( 32-Bit-WINDOWS version )

Installation and Programming Manual

Sokkia GSR 2700 ISX GPRS Configuration

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

SCI Testers and Remote Communication: Using HyperTerminal

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

BCOM-USB Device. User Manual.

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

User guide. Part number: Date: 15 July Navigating around this manual. Using this on-line manual. See page 5.

Version 1.0c May 6, 2010 ATK3

4G LTE CAT 4 Skywire User Manual

User Manual. August 2008 Revision 1.0. SKH300 ibutton Reader Configuration Utility

LM068 Bluetooth v4.1 Dual Mode RS232 Serial Adapter Standalone (With Embedded Bluetooth v4.1 Stack)

LM Technologies Ltd. Quick Start Guide LM048 and LM058 Bluetooth Serial Adapters. 1 Package Contents. 2 Setup

Wireless Modbus configuration

8 Setting Preferences

GEM80 & ewon Setup Quick Guide

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

Installation and Programming Manual

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions

CTI CALL INFORMATION INTERFACE

TouchKit Touch Panel User manual for Windows9X/ME Version: 3.1.4

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4

GP1 LCD RS232 Terminal Kit 2003 by AWC

Quick Start Guide. Appearance and pin assignments

Data Stream Manager. Technical Support Guide

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-422/485 Serial Adapter. Model: BLE-485C. 1. Package content: BLE RS-422/485 adapter

LM058 Bluetooth Serial Adapter

Skywire Development Kit User Manual

US-IP2. Monitoring Receiver

Abacus Electronics Pvt. Ltd.

Bluetooth RS232 Serial Adapter

Cabling Guide for Console and AUX

Documentation No. Product Version Page

ENGINEERING G. M. B. H. ENGINEERING MAKES THE DIFFERENCE

Hawki Advanced HyperTerminal Installation Instructions

ModbusLink M ModbusLink S. Operations & Maintenance Manual

IntesisBox KNX - AIRZONE

2 Project Tutorial! " #

AUTOLOG GSM-PLC STEP BY STEP

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

USR-GPRS-MODEM user manual

SmartLink Configuration Manual

Ethernet Serial Server

User Guide. Part number: Date: 11 September Navigating around this manual. Using this on-line manual. See page 5.

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0

SERIAL COMMUNICATION for Delta VFD drives

3 Connecting to a Controller

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1

1. PRODUCTS AFFECTED OVERVIEW REASON FOR UPGRADE EVERTZ SERVICE CONTACT INFORMATION FIRMWARE UPGRADE...

DOP 4 USERS MANUAL. Revision Feb Hauch & Bach Aps

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

TouchScreen for Display & Panel-PC

Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010.

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

QUCM ACCU-SORT. Installation and Programming Manual

GDI Communications, LLC. Graphical User Interface. User Manual. Version 1.0.1

INSTALLATION GUIDE Maxiflex P3e CPU M1262F

Skywire Development Kit User Manual

STYLITIS-POWER OPERATOR S GUIDE

Serial Computer Interface Module for ServSwitch Summit

Transcription:

Configuration DCE TAC-I

1. Table of contents 1. Table of contents... 2 2. Introduction... 3 3. Communication ports... 4 4. Parameters... 5 4.1. NEG Micon, Vestas - TAC I... 6 4.2. NTK / Nordtank / Wincon - TAC I (Old version)... 7 4.3. NTK / Nordtank - TAC I (new version)... 8 5. Cables... 9 5.1. TAC-I... 9 6. Installation checklist... 10 7. Four Faith F2403 GPRS Signal monitoring... 11 PS-Data April 29 th 2013 Page 2

2. Introduction This document shows how to enable RS232 communication on a DCE TAC-I controller. The document includes: How to change parameter and which settings needs to be changed. Hardware updates and changes. What new hardware is needed. Cable connections. PS-Data April 29 th 2013 Page 3

3. Communication ports To be able to communicate with a TAC-I controller is it necessary to have a communication card installed. A TAC-I normally has two com port2 (Com 1 and Com 2) that can be used for serial communication. But if it has not been used for communication before or if it has been used for current loop communication is it necessary to install serial RS232 interface card or replace the current loop driver The com ports are located on the top left side of the TAC computer. It is easy to see if the driver card is a current loop driver or a RS232 driver: RS232 driver Current loop driver A correct mounted RS232 driver card must be installed as displayed in the picture beneath. Position for com card Installed as COM 1 Position for com card Installed as COM 2 Normally is com 1 used but com 2 can be used if com port is already occupied for eg. communication to other turbines using the current loop driver. Be aware that if an internal modem is installed is the RS232 interface driver card hidden beneath. PS-Data April 29 th 2013 Page 4

4. Parameters The following parameters have to be set to get a TAC-I working. Baud rate Data bits Parity Stop bit Modem handling Id number The parameters are found in the menu system: The menu system has the following structure. It is navigated using the arrow keys and enter is used to select menu or accept a data input. Data is entered by using the cursor keys to toggle the numbers in the input field. Dependent on the TAC-I controllers program version can the layout of the menu s be different Please refer to the following chapters for the different layouts Note that there are two distinct types. The older layout has each communication protocol and port listed so that they can be activated or disabled using a 0 and 1. The newer layout has been simplified so that the protocols are only listed one time. But the major difference is that the protocol is NOT activated or disabled BUT instead assigned directly to a port. The standard ports are 1, 2 or 3. PS-Data April 29 th 2013 Page 5

4.1. NEG Micon, Vestas - TAC I Highlighted items are the parameters that typically need to be configured. Status Grid Operation Counters Temperature User parameters o Set user parameters o Set date/time o Set communication protocol Debug com port DCE3 com port Set to 1 for COM 1 Set to 2 for COM 2 Depends on the used port. FDV 2.00 com port ASCII data com port Modbus com port Enable WMS CIMS Alarm Call com port Set to 0 DCE1 com port Configure DCE1/Modbus o o Warning stack Error stack Set communication parameters Serial port com1 Receive baud Set to 9600 Transmit baud Set to 9600 Data bits (7/8) Set to 8 Parity (0/1/2) Set to 0 Stop bit (1/2) Set to 1 Modem control (0/1) Set to 0 Handshake (0/1) Set to 0 Serial port com2 Serial port com3 Set phone call WTG id. no. Set to serial no WTG telephone no. Not used on direct com Alarm call no. 1 Not used on direct com Alarm call no. 2 Not used on direct com Alarm call no. 3 Not used on direct com Alarm call no. 4 Not used on direct com Alarm call no. 5 Not used on direct com Service call no. 1 Not used on direct com Service call no. 2 Not used on direct com Alarm port # Set to 0 PS-Data April 29 th 2013 Page 6

4.2. NTK / Nordtank / Wincon - TAC I (Old version) Highlighted items are the parameters that typically need to be configured. Status Grid Operation Counters Temperature User parameters o Set user parameters o Set date/time o Set communication protocol Serial port com1 DCE1 DCE2 DCE3 Set to 1 (If using com1) Serial port com2 DCE1 DCE2 DCE3 Set to 1 (if using com2) Serial port com3 DCE1 DCE2 DCE3 Set to 0 o Set communication parameters Serial port com1 Receive baud Set to 9600 Transmit baud Set to 9600 Data bits (7/8) Set to 8 Parity (0/1/2) Set to 0 Stop bit (1/2) Set to 1 Modem control (0/1) Set to 0 Handshake (0/1) Set to 0 Serial port com2 Serial port com3 o Set phone call WTG id. no. Set to serial no WTG telephone no. Not used on direct com Alarm call no. 1 Not used on direct com Alarm call no. 2 Not used on direct com Alarm call no. 3 Not used on direct com Alarm call no. 4 Not used on direct com Alarm call no. 5 Not used on direct com Service call no. 1 Not used on direct com Service call no. 2 Not used on direct com Alarm port # Set to 0 Warning stack Error stack PS-Data April 29 th 2013 Page 7

4.3. NTK / Nordtank - TAC I (new version) Highlighted items are the parameters that typically need to be configured. Status Grid Operation Counters Temperature User parameters o Set user parameters o Set date/time o o o Warning stack Error stack Set communication protocol Select protocol type DCE 1 com port DCE 3 com port Set to 1 for COM 1 Set to 2 for COM 2 Depends on the used port FDV 2.00 com port NT1 com port Alarm Call com port Set to 0 Setup DCE 1 protocol Set communication parameters Serial port com1 Receive baud Set to 9600 Transmit baud Set to 9600 Data bits (7/8) Set to 8 Parity (0/1/2) Set to 0 Stop bit (1/2) Set to 1 Modem control (0/1) Set to 0 Handshake (0/1) Set to 0 Echo control (0=off) Serial port com2 Serial port com3 Set phone call WTG id. no. Set to serial no WTG telephone no. Not used on direct com Alarm call no. 1 Not used on direct com Alarm call no. 2 Not used on direct com Alarm call no. 3 Not used on direct com Alarm call no. 4 Not used on direct com Alarm call no. 5 Not used on direct com Service call no. 6 Not used on direct com Service call no. 2 Not used on direct com Alarm port # Set to 0 PS-Data April 29 th 2013 Page 8

5. Cables 5.1. TAC-I Four-Faith DB9 Female TAC-I DB9 Male 2 3 5 7 8 3 2 5 PS-Data April 29 th 2013 Page 9

6. Installation checklist This is a checklist for the steps needed to install the GPRS modem into a turbine with a TAC-I controller. Follow the steps beneath and report the final settings to the administrator of the Alarm center server. Step Description Done Hardware installation 1 Install the Four-Faith GPRS modem and antenna 2 Check if the TAC has a RS232 port If board is missing install it Note what port it is installed on Board to the right = COM1 Board to the left = COM2 3 Install the RS232 cable between TAC computer and the Four-Faith modem. 4 Power up Four-Faith modem Verify power light is on Verify that online light is coming on (Can take a minute) TAC parameter configuration: 5 Check the turbine id number. It is default set to 11 but it is recommended to enter the serial no of the turbine. 6 Check / Activate the DCE3 port on the COM port where the RS232 driver card is installed 7 Check the turbine port setting. Remember to check the right port number according to where it RS232 driver board are located. The port settings must be the same as the GPRS modem. Set Baud rate. Typically 9600 Baud Set data bits: Typically 8 databits Set parity: Typically set to None (0) Set stop bits: Typically 1 stop bit 8 Remove alarm call in the turbine by setting the Alarm port to 0 Report the settings to the Alarm Center administrator for server configuration. 9 Example value Modem device number 11 Modem baud rate 9600 Modem data bits, parity settings and stop bits 8N1 (8, None, 1) Turbine name Test park Turbine id number 11 Turbine model NM-48 Turbine size 750 Turbine GPS coordinates 56.094985, 10.136058 PS-Data April 29 th 2013 Page 10

7. Four Faith F2403 GPRS Signal monitoring The Four Faith F2403 GPRS modem can be used to monitor the signal strength during installation. This can be done on units bought after October 2014 and with firmware versions after this date. The Signal mode is activated using a special DB9 adaptor that is inserted into the RS232 port on the Four Faith modem. When the adaptor is inserted will the online LED on the modem not display the online status anymore but instead will the signal strength be display. The signal level is illustrated by a number of blinks that is repeated every 3 seconds. There are 5 different blink levels. Level Signal strength (dbm) Quality 1-113 -> -103 Bad 2-101 -> -95 Marginal 3-93 -> -85 OK 4-83 -> -75 Good 5-73 or higher Excellent The GPRS modem will not attempt to connect unless the signal strength is 2 or above but the signal should be no less than 3 or more before a stable connection can be expected. Be aware that when the Signal tester adaptor is inserted will the modem NOT attempt to go online. The modem will return to normal operation when the adaptor is removed. PS-Data April 29 th 2013 Page 11