Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Similar documents
INTELLIGENT SERVER. Model: BMS-LSV6E

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

BACnet System SERVICE MANUAL. Intelligent Server. BACnet Server Software BMS-LSV6UL BMS-STBN09UL. FILE No. A Revised Nov (2) Model name:

DYNA-KIT. Owner s Manual. COMMUNICATION ADAPTER Model name: TCB-DK01SS-E. 1 English

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

ERV Control Interface Installation / Operation manual. TCB-IFVN1UL ERV Control Interface ENGLISH

RBC-AMS55E-ES RBC-AMS55E-EN

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

User Guide Automatic Transfer Switch (ATS)

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

AT-RG613/623 TX - Series Residential VoIP Gateway - User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual

5 B&W Rear View System Camera


INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG

1:1 Model Connection Interface

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

Mitsubishi Electric Air-conditioner Network System

INSTALLATION MANUAL Wired Remote Control


XTM1250SA DIN rail three phase four wire LCD display energy meter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

RS232C/RS485 Data can be easily monitored by LAN

Model No. ET-JPF200BE

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

SERVICE MANUAL WEB BASED CONTROLLER

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

User's Guide. Model W 3-in-1 Switching DC Power Supply

FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

DC-D2212R / DC-D2212WR

B&W RearView Camera Installation & Operation

1 Channel Strobe Controller ORDERCODE 40226

TVAC25100 TVAC25110 User manual

Power supply unit Model: PAC-SC51KUA

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Network Camera. Quick Guide DC-B1203X. Powered by

Quick Reference Guide

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Under the Table Interconnect Solutions

DSS Console and DSS Console for Attendant for Digital Super Hybrid Systems. Reference Guide ANSWER RELEASE

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

NIR Moisture Analyzer KB-30

INSTALLATION INSTRUCTIONS

CMSA-100 Manual. Cinema Media Server Automation

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

1. Safety Precautions (Read these precautions before use.)

SUBWOOFER SYSTEM YST-MSW10

Hardware Manual. intelligent Touch Controller

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Startup Guide C01

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

QIT600F1 USER'S GUIDE

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

DC-D4213RX DC-D4213WRX

Network Camera. Quick Guide DC-D1223WX. Powered by

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

INSTALLATION INSTRUCTIONS

Installation Guide. Home Network System Smart Plug KX-HNA101FX. Model No. Thank you for purchasing a Panasonic product.

DOT MATRIX PRINTER SP6000 SERIES

EC Series. Safety Guide

High Precision Quad Output DC Power Supply

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

HX1 Bluetooth Stereo Headset

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Motorized Curtain Tracks Progress 50 Motor Set

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Network Camera. Quick Guide DC-S1283WRX. Powered by

INSTALLATION MANUAL For authorized service personnel only.

Optional Lens User s Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

User Manual VIDEO DOOR PHONE

Transcription:

Model name: BMS-LSV6UL INTELLIGENT SERVER

Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This product is designed exclusively for use in North America. Do not use it in a place other than North America. Contents Precautions for safety...2 Before Installation...4 Intelligent Server Specifications...5 1 CF (Compact Flash) card Installation...6 2 Setting...7 3 Installation...7 4 Cable Connection...9 1-EN 1

Precautions for safety The following instructions must be observed. Carefully read these Precautions for safety before installation, and perform installation work safely. These precautions contain important information regarding safety. After installation work, carry out an operation trial to confirm that there are no problems, and explain to the customer how to operate and maintain the system. Ask the customer to keep this. Expressions Warning Graphic symbols Text set off in this manner indicates that failure to adhere to the directions in the warning could result in serious bodily harm (*1) or loss of life if the product is handled improperly. Text set off in this manner indicates that failure to adhere to the directions in the caution Caution could result in serious bodily injury (*2) or damage (*3) to property if the product is handled improperly. *1: Serious bodily harm indicates loss of eyesight, injury, burns, electric shock, bone fracture, poisoning, and other injuries which leave aftereffect and require hospitalization or long-term treatment as an outpatient. *2: Bodily injury indicates injury, burns, electric shock, and other injuries which do not require hospitalization or long-term treatment as an outpatient. *3: Damage to property indicates damage extending to buildings, household effects, domestic livestock, and pets. Prohibited Compulsory indicates prohibited items. The actual contents of the prohibition are indicated by a picture or text placed inside or next to the graphic symbol. indicates compulsory (mandatory) items. The actual contents of the obligation are indicated by a picture or text placed inside or next to the graphic symbol. Warning Installation and reinstallation should be performed by your dealer or a qualified electrician. Attempting to carry out installation work on your own, and doing so incorrectly, may result in electric shock or fire. Electrical work must be performed by a qualified electrician in accordance with this installation manual. The work must satisfy all local, national and international regulations. Inappropriate work may result in electric shock or fire. Be sure to turn off the power before starting work. Failure to do so may result in electric shock. Do not modify the unit. Doing so may result in excessive heat or fire. Always connect to ground. Improper grounding may result in an electric shock. EN 2 2-EN

Trademarks Caution Do not install in the following locations. Locations where combustible gas may leak Locations with high humidity or water Dusty locations Locations in direct sunlight and locations subject to high temperatures Locations within 1 m from televisions or radios Outdoors, under awnings, or other locations exposed to rain and dew Locations exposed to outside air containing corrosive gases or salinity Locations with frequent vibrations Do not operate the touch panel with mechanical pencils or other pointed objects. In installation work, use wiring with the correct ampacity. Failure to do so may result in excessive heat or fire. Use specified cables and connect them securely, and do not subject connecting terminals to external force. Doing so may result in broken cables, excessive heat or fire. Always install a circuit breaker on the primary side of the power supply. Always turn off the power before inserting or removing a compact flash card. Failure to do so may result in damage to data and files. Clean the touch panel by wiping with an eyeglasses cleaner or other soft cloth. To remove oil-based ink, wipe with a cloth that has been moistened with a neutral detergent and then wrung out, and finish by wiping with a soft, dry cloth. Do not use commercial OA cleaners, cleansers, or other liquid cleaners containing abrasives. BACnet is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.). Compact Flash and CF are trademarks of SanDisk Corporation. Ethernet is a registered trademark of Xerox Corporation. 3-EN 3

Before Installation NOTE Prepare the following software (sold separately) before using the server. Available software INTELLIGENT SERVER SOFTWARE BMS-STBN UL ( is 09 or higher) Check the following package contents. No. Item Quantity Remarks 1 INTELLIGENT SERVER 1 2 1 3 Manual 1 4 Cable 1 RS-485 cable for Intelligent Server 5 Closed end wire joint 2 6 Clamp filter 2 7 Tie-wrap 2 For fixing the clamp filter 8 Power cable 1 Use the following wiring materials to connect the communication cables and power cables. (locally procured) No. Line Description 1 For RS-485 2 For ethernet Type Wire size Length Type Length 2-core shield wire AWG16 (1.25 mm 2 ), 1600 ft (500 m) max. (total length) LAN cable (higher than Category 5, UTP) The appropriate use of straight cable/cross cable should be done depending on your system used. 320 ft (100 m) max. EN 4 4-EN

Intelligent Server Specifications Names of each parts POWER switch L1 LED L2 LED S1 switch L3 LED RUN LED Shut down switch L1 L2 ON S1 OFF L3 RN SDR COM1 USB LAN1 PS/2 LAN2 VGA Specifications AC inlet (AC IN) Ethernet port2 (LAN2) Ethernet port1 (LAN1) CF CARD slot Serial port1 (COM1) Power supply Current Operating temperature/humidity Storage temperature Dimension Mass COM port LAN 120 VAC, 60 Hz 0.2 A 32 to 104 F (0 to 40 C), 10 to 90 %RH (no condensation) 4 to 140 F ( 20 to +60 C) 9.84 (W) 2.76 (H) 5.71 (D) inch (250 (W) 70 (H) 145 (D) mm) (11.5 (292) (W) including the fixing metal plate) 3.31 lb (1.5 kg) RS-485 (9-pin, D-SUB) 10BASE-T/100BASE-TX 5-EN 5

External view Unit : inch (mm) 4.13 (105) 5.71 (145) 0.75 (19) 0.354 (9) 4.92 (125) 2.76 (70) 0.433 (11) 9.84 (250) 4 - Ø23 / 128 (4 Ø4.6) 2.74 (69.5) 0.126 (3.2) 11 (280) 11.5 (292) 1 CF (Compact Flash) card Installation REQUIREMENT Do not insert or remove the CF (Compact Flash) card during power on of the Intelligent Server. Doing so may cause a failure. If the CF (Compact Flash) card is not inserted properly, the Intelligent Server will not work. Insert the CF card (with the software sold separately). Push the CF card fully into the slot. Rating label CF card (1) Remove two screws and the cover plate and the CF card slot appears. (2) Insert the CF card with its rating label attached surface upward. Confirm the CF card is surely pushed into the slot. EN 6 6-EN

2 Setting The setting is not required. S1 is set to OFF. 3 Installation Intelligent Server Installation Method and Orientation There are 2 types of setting methods and directions available for the server. Use the fixing metal plates attached when installing the server. (1) Surface mount (2) Wall mount Mount the server with the front face upward. Fixing screw hole positions Unit : inch (mm) 0.24 (6) 11 (280) 0.24 (6) 4.13 (105) 0.75 (19) 5.71 (145) AC inlet side 0.83 (21) 4 - Ø23 / 128 (4 Ø4.6) 7-EN 7

REQUIREMENT Do not install the unit in any of the following places. Humid or wet place Dusty place Place exposed to direct sunlight Place where there is a TV set or radio within one meter Place exposed to rain (outdoors, under eaves, etc.) Installation Space and Maintenance Space The installation space and the maintenance space must be determined before installation. These spaces depend on installation method. Installation Space The values in the following table are required for installation space in each direction. Select an installation place that allows good air ventilation. Rear Top Right side Left side Front Unit : inch (mm) Item Direction Surface mount Wall mount Top 3.94 (100) 1.97 (50) Bottom 0 0 Installation space Front 3.94 (100) 3.94 (100) Rear Location adjacent to wall permitted (*1) Right side 1.97 (50) 3.94 (100) Left side 1.97 (50) 3.94 (100) (*1) Location adjacent to wall permitted means that the unit can be installed close to the wall on that side. EN 8 8-EN

Maintenance Space Maintenance space is required for installation and maintenance of the unit. Rear Unit : inch (mm) INTELLIGENT SERVER Front 39.37 (1000) 39.37 (1000) : : Maintenance space Installation space 4 Cable Connection AC Power Cable Connection REQUIREMENT Power cable is not supplied for the Intelligent Server. Insert a three core power cord applicable to the standard of the country you use. Be sure to connect the earth line of the power cable securely. Insert an AC power cable into the AC inlet of the unit. Connect the power cord plug to an outlet (120 V, AC). REQUIREMENT Disconnect the appliance from the main power supply. Connect this appliance to the main power supply by a circuit breaker or a switch with a contact separation of at least 0.118 (3 mm). Make sure that the outlet is earthed. Ethernet wire Connection Insert the Ethernet wire into the Ethernet port1 (LAN1). Serial Port (RS-485) Connection Confirm that the power supply for the Intelligent Server is shut off. Connect RS-485 cable (packaged with the Intelligent Server) to Serial port 1 (COM1). Fix the cable to the Intelligent Server by the fixing screws (two locations on both sides) attached to the connector on RS-485 cable. 9-EN 9

REQUIREMENT Attach the supplied clamp filter to the LAN cable and RS-485 cable. * Wind the LAN cable and RS-485 cable around the clamp filter as shown below when attaching the filter to the cable. After attaching the filter, fix it to the LAN cable and RS-485 cable using a supplied tie-wrap. * Attach the clamp filter as near the main unit as possible. LAN cable RS-485 cable Connection to the TCS-NET Relay Interface TxRx(+) Connection Connect the two wires (red and orange wires) of the four RS-485 wires and the wire from the terminal board RS- 485 A of the TCS-NET Relay Interface using the closed end wire joint. The red and orange wires can be connected directly to the terminal board RS-485 A of the Relay Interface. TxRx(-) Connection Connect the two wires (brown and yellow wires) of the four RS-485 wires and the wire from the terminal board RS-485 B of the TCS-NET Relay Interface using the closed end wire joint. The brown and yellow wires can be connected directly to the terminal board RS-485 B of the Relay Interface. Intelligent Server Closed end wire joint RS-485 cable Red/Orange Brown/Yellow Shield wire open (insulated) RS-485 RS-485 AB TCS-NET Relay Interface Connect the shield wires of the 2 wires Shield wire earth connection RS-485 AB TCS-NET Relay Interface NOTE The RS-485 signal wire has polarity. If connected with incorrect polarity, the unit will not work. Do not connect or disconnect the wire during control operation. Doing so may cause a malfunction. EN 10 10-EN