This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

Similar documents
This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC660BSM120. BUS Switching Module 115Vac/125Vdc.

PACSystems* RX3i IC695PSA140

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

PACSystems* RX3i IC695PSA040

PACSystems RX3i IC695PSA140

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

This Datasheet for the IC697BEM731. Series Genius I/O Bus Controller.

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

IC693 PLC IC693ACC350, IC693ACC340/341

PACSystems RX7i IC698CHS009/119

PLC Racks IC697CHS782/783

AC Input /AC Output. Module

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Analog Voltage Combination Module

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

PV Rapid Shutdown device

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

Table of Contents. Safety. Attention. Warnings

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

PanelView Plus/VersaView CE Terminals and Display Modules

16-Channel Digital Output Module 120Vac/dc

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. AC Guarded Digital Output Module 110 VAC (T3464) PD-6021

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

24 Input/8 Output AC Block I/O Module

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Dell MD1280 Storage Enclosure Getting Started Guide

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

Installation Instructions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Digital ac/dc (24V) Input Module

Relay Contact Output Modules

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

EX-RC1 Remote I/O Adapter

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Analog Input, 16-Bit Thermocouple Module

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

PS/IO Circuit Board Retrofit

Dell SC7020 Storage Controller Getting Started Guide

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

PFC Mini TM Power Factor Corrected AC-DC Switchers

EFE300 / EFE400 EFE300M / EFE400M

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

Installing the IPS 4345 and IPS 4360

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped.

VersaMax* Analog Input, 16-Bit Thermocouple Module

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Installation, Operation and Maintenance Manual

Zenith DS9000 Dispensing System

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Programmable Controller IC697ACC721/724/744

EX-RC1 Remote I/O Adapter

ACCESS 9340/9360 Meter Input/Output Module

MT8050iE series. Installation Instruction (1) (2)

MDM 011-Z1 Regen Resistor

BMX DDM Mixed Relay Input/Output module

SIMATIC TI505. Smart Slice Discrete I/O Module. User Manual. Order Number: PPX: Manual Assembly Number: Second Edition

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

IC693PWR331 High Capacity Power Supply, 24 VDC Input

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

GE Fanuc IC695ALG708. Rx3i PacSystem

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

895/896M Frequency Output Math Modules

Technical Manual SMART TRAC PS Card

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

VersaMax Genius Network Interface Unit


Analog Input Installation Manual

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

INSTALLATION INSTRUCTIONS

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

Instructions to printer DO NOT PRINT THIS PAGE

M-series Intrinsically Safe I/O

Transcription:

This Datasheet for the IC660BBD101 Block 115Vac I/O Low Leakage 8 Circuits http://www.cimtecautomation.com/parts/p-14434-ic660bbd101.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-30 module. For further information, please contact Cimtec Technical Support at 1-866-599-6507 sales@cimtecautomation.com

Description The 115VAC Low-leakage I/O Block (IC66*BBD101) is an intelligent, configurable module that interfaces discrete sensors and actuators to a communications bus. The block has eight identical 115VAC circuits. Each circuit can be used as either an input or an output. 115V 50/60 z In/Out Features Block features include: Selectable input Filter Time from 10ms to 100ms. Output feedback for monitoring. Output powerup defaults. Outputs hold last state or default. Pulse Testing for outputs. Bus Switching Module control. Control power for the block is tapped off the input/output device voltages wired to the terminals. o separate block power supply is needed. Each circuit has electronic fusing that shuts down the circuit in 5ms if output current exceeds 30 Amps with the output turned on, or 20 Amps after 2 cycles. The circuit is easily restored by command from a and-held Monitor or the CPU. Block diagnostics include: Overtemperature Failed Switch Open Wire for tristate inputs Overload Detection and Shutdown o-load Detection Fault reporting can be enabled or disabled circuit by circuit. Using this Datasheet This datasheet summarizes information about block installation, configuration, and diagnostics. Your primary reference should be the Discrete and Analog Blocks User s Manual. It includes detailed instructions for block installation and configuration. For additional information about systems and communications, including bus specifications, refer to the I/O System and Communications Manual. Specifications Catalog umbers Block IC66*BBD101 Electronics IC66*EBD101 Terminal IC66*TSD100 Block Specifications Size (height x width x depth) 8.83 (22.44cm) x 3.34 (8.48cm) x 3.91 (9.93cm) Weight 4 lbs. (1.8 kg) LEDs (I/O Block) Unit OK, I/O Enabled LEDs (each circuit) On logic side of switch Block to Block Isolation 1500V eat Dissipation 16W maximum with 8 inputs, 43.5W maximum with 8 outputs on at 2 Amps. Standby power (all inputs and 8.5 Watts outputs off) Operating voltage (single source) 93-132VAC Frequency 47-63 z Power supply dropout time 1 cycle (16.7ms at 60z, 20ms at 50z) Input Specifications on-tristate input OFF state min. voltage across input device (I to ) 60V RMS OFF state, max. leakage through input device 1.5mA O state, max. voltage across input device (I to ) 20V RMS O state, max. switch current threshold 6mA RMS Tristate input OFF state, acceptable voltage across input device (I to ) 16V RMS-40V RMS, O state, max. voltage across input device (I to ) 4V RMS Input load network to : 13K Ohms Capacitor to : 0.10 µf Input processing time (typical) 2ms + filter Selectable input filter times 10 to 100ms in 10ms increments Input diagnostics Open Wire, Overtemperature, Failed Switch Output Specifications Circuit output current (steady state) 2 Amps RMS Max. inrush current up to 2 cycles 25 Amps peak Maximum inrush current 2-6 cycles 14 Amps peak Maximum block output current 15 Amps at 35 C, 7.5 Amps at 60 C Output Leakage @ 115 VAC Current at 0 volt output (OUT to ): < 7mA Voltage at open output (OUT to ): 65 volts Output switch Zero crossing (OFF to O/O to OFF) Maximum switching frequency once per second (high inrush currents) Turn-on delay 0.5 z + 1ms, maximum Voltage drop 2.5V at 2 Amps, 10V at 30 Amps inrush Recommended min. load (o Load 25mA resistive, 40mA inductive disabled) o Load enabled threshold 50mA Fusing Internal electronic short circuit trip. 100ms long time trip Output diagnostics Short Circuit, Overload, o Load, Failed Switch, Overtemperature Environmental Specifications Operating temperature 0 C to +60 C (+32 to +140 F) Storage temperature -40 to +100 C (-40 to +212 F) umidity 5% to 95% (non-condensing) Vibration 5-10 z 0.2 (5.08mm) displacement, 10-200 z at 1G Refer to GFK-0867 for product standards and general specifications. 1

Compatibility This block is fully compatible with and-held Monitor model IC66*M501. It may be used with IC66*M500; however, M501 is required to change the baud rate or to configure the block for redundancy. If the block will be used on a bus controlled by an IC550 series PLC, or a host computer equipped with a bus interface module, and the block will be configured as an inputs-only block, it may be necessary to upgrade the IC550 bus controller or computer bus interface module as detailed in the Discrete and Analog Blocks User s Manual. Block IC66*BBD101 is designed to control small loads without the addition of parallel load resistance. It is also suitable for installations where a Class 1 Division 2 rating is required for Factory Mutual. This block is backward compatible with blocks IC66*CBD100 and BBD100, and may be used to replace them. Electronics IC66*EBD101 replaces IC66*ELD100 and EBD100. Terminal Assemblies IC66*TSD100E and later are not compatible with earlier versions of the Electronics. If the Terminal will be used to replace Terminal IC66*TSD100D or earlier, the Electronics must be either replaced with version IC66*EBD101F or later, or upgraded. Installation Instructions Carefully inspect all shipping containers for damage. If any equipment is damaged, notify the delivery service immediately. Save the damaged shipping container for inspection by the delivery service. After unpacking the equipment, record all serial numbers. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system. Block Mounting Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least 2 inches of space between blocks. Mount the block by drilling two screw or bolt holes for 8-32 hardware. Position the block so that the notches in the upper and lower flanges line up with the mounting holes. Mount the block using 8-32 screws. Use star washers to provide ground integrity. Removing an Electronics The block s Electronics can be replaced with a compatible model without removing field wiring or reconfiguring the block. Retaining Screws (Qty. 2) Electronics 1. Unscrew the retaining screws at the top and bottom of the block. 2. Using a Block Puller (IC660BLM507), engage the tabs in the first vent slots. Move the tool to the center of the block and squeeze the handle. 3. Pull the Electronics upward. Warning If power is applied to the field terminals, power is also exposed on the connector pins at the base of the Terminal, and electrical shock hazard exists. Do not touch the connector pins! Death or injury may result. Inserting an Electronics 1. Align the Electronics in the guides and push down firmly. Caution Do not exert excessive force; it may damage the block. 2. If unusual resistance is met, remove the Electronics. If power is applied to the block, DO OT TOUC TE COECTOR PIS! Inspect the Terminal, connector receptacle, and connector edge board (on the Electronics ). Be sure the keying matches. Remove any obstacles and reinsert the Electronics. Pay close attention to the alignment of the guide pins. 3. Secure the Electronics with the screws on the top and bottom of the Terminal. Grounding The block s mounting screws must not be used as the only means of grounding the block. Connect the green ground screw on the block to a reliable ground system using a short wire lead, minimum size AWG #12 (avg 3.3mm 2 in cross-section). Warning If mounting screws do not make good ground connection and the ground screw is not connected to a reliable ground, the block is not grounded. Electrical shock hazard exists. Death or personal injury may result. Block Wiring All terminals accept one AWG #12 wire (avg 3.3mm 2 cross-section) or two AWG #14 wires (each avg 2.1mm 2 in cross-section). The minimum recommended wire size is AWG #22 (avg.36mm 2 in cross-section). Block terminals can also accommodate spade or ring terminals up to 0.27 inch (6.85mm) wide with a minimum opening for a #6 screw, and up to 0.20 inch (5.1mm) depth from the screw center to the back barrier. Be sure unshielded wire ends are not longer than 2 inches (5 cm). Do not overtorque the terminal screws. Recommended torque for all terminals is 6 in/lb (.678 /M). Terminal Connector Pins 2

Serial Bus Wiring Terminals 1 to 4 are for the serial bus. If the block will be used as a BSM Controller, first install the Bus Switching Module at the block s serial bus terminals. Then connect the serial bus cables to the BSM terminals, as described in the Bus Switching Module datasheet. Wire either of the BSM s pigtail wires to terminal 10. Connect the second BSM wire to an terminal. Using one of the cable types recommended in the System and Communications User s Manual, connect the serial bus to terminals 1-4. 1 SERIAL 1 2 SERIAL 2 3 SIELD I 4 SIELD OUT If the block is at either end of the bus, connect a terminating resistor of the appropriate type (see the System and Communications User s Manual for details) across its Serial 1 and Serial 2 terminals. Terminating Serial 1 Serial 2 Shield In Shield Out Start of Bus End of Bus Terminating Serial 1 Serial 2 Shield In Shield Out If you want to disable the block without removing power from input devices, use a Block Puller to unplug the Electronics. Do not disconnect or to remove power. Field Wiring Connect wiring for I/O devices to terminals 10-17. Connect twowire output devices to, and two-wire input devices to, as shown below left. Connect three-wire devices as shown below right. Output Signal (hot not used) (10-17) eutral Typical Output Device Wiring Input Signal (10-17) (neutral not used) Typical Input Device Wiring AC Power Source ote: Terminals 5-9 and 18-22 are connected in the Terminal 1 2 3 4 5 6 7 8 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 1 2 3 4 5 6 7 8 Connect a 115 volt AC source to one of the terminals on the terminal strip. Connect neutral to an terminal. All terminals are internally bussed, as are all terminals. Extra power terminals are for convenience. Depending on the physical layout and current loads, hot connections can be bussed together and made by one wire to the block or power source. eutral connections can also be bussed together and made by one wire. Any circuit can be an input or output. Connect the power source through the input device (such as a switch) to a discrete input circuit on the block. For outputs, power is routed through the block electronics to a discrete circuit and applied to a load. Connect the load return to the terminal. Make all power connections on the block to the same 120 VAC phase. Different blocks can have different phases between them. IPUT OUTPUT BLOCK 1 Power Disconnects 115 VAC PASE 1 IPUT OUTPUT BLOCK 2 115 VAC PASE 2 Since block power is the same as circuit power, it is important to wire block power disconnects so that block power and input power will be removed at the same time. POWER DISCOECT AC YES O BLOCK Caution LOAD If I/O circuit power is not removed at the same time as block power, the block may power up when multiple inputs are activated, even though one leg of power has been removed from the block. Wiring for Tristate Inputs If an input circuit should report open wire conditions, install a 5.1K ohm, 1/2 Watt or larger non-inductive resistor across the dry contacts of the input device. The circuit must be configured as a Tristate Input. External Suppression If a contact is wired between the block and a load, install suppression across the load. capacitor suppressors are preferred for low current, high inductance loads. For a high-power load, instead use a voltage-clamping device such as a MOV. RC suppressors are also recommended to reduce electromagnetic interference. Power supply-side switches may require line to line suppression if power is to be switched with devices energized. See the Discrete and Analog Blocks User s Manual for more information about using suppression. I 3

Block Operation The 115VAC Low-leakage I/O block has eight identical circuits rated to operate at a nominal 115 volts AC. It can be used as combination input/output, inputs-only or outputs-only block. If the block is configured as a combination block, circuits can be any mix of inputs and/or outputs. The actual state of each output circuit will be returned to the CPU in the corresponding input reference location. The CPU can monitor the feedback state to verify (after an appropriate delay) that the output switching device has operated properly and that the load has the proper voltage and current applied. If the block is configured as an inputs-only block, all circuits must be regular inputs or tristate inputs. If the block is configured as an outputs-only block, all circuits must be outputs; no feedback analysis will be performed. Each circuit has its own LED. If the circuit is used as an input, the LED indicates the presence of threshold voltage at the input terminal. If the circuit is used as an output, the LED indicates the state commanded by the CPU. Configured as an Input Configured as an Output Input Device Output Device 1-8 Field Connections *.2µF for Block IC66*BBD100.1µF for Block IC66*BBD101 Preload 13K Terminal MOV * Internal Circuits Smart Switch 115 VAC Internal +5V Processor 115 VAC LEDS The block's Unit OK and I/O Enabled LEDs show its operating status: Unit OK I/O Meaning Enabled O O Block functioning, CPU communicating O OFF Block functioning o CPU communications for 3 bus scans O Blinking Block functioning, Circuit forced Blinking O Circuit fault, CPU communicating Blinking OFF Circuit fault o CPU communications for 3 bus scans Alternate Blinking Circuit fault, Circuit forced Synchronous Blinking o CPU communications - block number conflict OFF Don t Care o block power, or block faulty For each input circuit, the circuit LED indicates the presence of threshold voltage at the input terminal. Output circuit LEDs show the state commanded by the CPU. Diagnostics Block diagnostics are listed below. Overload and o Load reporting are optional features that can be disabled during block configuration. Open Wire: Voltage, but no current on tristate input. Overtemperature: Block s internal temperature is above 100 C. Short Circuit: Instantaneous current on an output exceeds 30A during first two line cycles or 20A thereafter. Output is turned off automatically. Overload: A load exceeds 2.8A (2.0A RMS) continuously for 100ms. Output is turned off automatically. o Load: Load does not continuously draw 50mA from the output circuit. Failed Switch: May mean output s internal feedback state does not match its commanded state. False Failed Switch diagnostics may be reported if an external device like a manual switch is wired in parallel with an output. Several other Failed Switch faults may be reported on inputs and outputs, indicating a need to replace the Electronics. Configuration First, the block must be configured with a and-held Monitor to: Enter its Device umber (serial bus address). Enter its Reference umber (required only for IC600 and IC550 series PLCs only). In addition, unless all circuits on the block will be inputs, the Block I/O Type must be set to either Outputs or Combination on the Program Block ID screen. The rest of the features can be configured either using a and-held Monitor, or by sending a Write Configuration datagram to the block from the host. ote: If a block is configured offline, it must be properly grounded and have a 75 Ohm resistor installed across its Serial 1 and Serial 2 terminals. See the Discrete and Analog Blocks User s Manual for instructions. Feature Circuit / Block Factory Setting Selections Device umber Block null 0 to 31 (a number must be selected) Reference Address Block none Depends on host CPU type Block I/O Type Block input input, output, combination Baud Rate Block 153.6 std 153.6 std, 153.6 ext, 76.8, 38.4 Kbd Pulse Test Block enabled enabled, disabled Input Filter Time Block 20ms 10 to 100ms Overload Shutdown Circuit yes yes, no Circuit I/O Type Circuit input input, output, tristate input Report Faults Circuit yes yes, no old Last State Circuit no yes, no Output Default State Circuit off on, off BSM Present Block no yes, no BSM Controller Block no yes, no Output Default Time Block 2.5 sec 2.5 or 10 seconds CPU Redundancy Block none none, hot standby, duplex Duplex Default Block off on, off Configuration Protection Block disabled enabled, disabled 4