SCS (System Core Server) Model BCY44100M

Similar documents
Infilex GC Multipurpose Controller Model WY5311

Infilex GD Multipurpose Data Gathering Panel Model WY5310

Infilex AC AHU Controller Model WY5317C

Infilex GC Multipurpose Controller Model WY5111

Intelligent Component Series Direct Coupled Damper Actuator Model MY8040A

BACnet Controller for General-purpose Building Applications

(Thermoplate (Auxiliary part))

Building Management System. (Version or later)

PARAMATRIX -III Chiller Controller Model WY7400T

PARAMATRIX 4 Chiller Controller

I/O Modules, User Terminal Module, and SAnet Interface Module

Facility Management Station

Infilex AC. Air Handling Unit Controller for NC-bus Communication. Specifications/Instructions. General. Features AB-6438

Infilex VC Variable Air Volume Controller with Actuator for SC-bus Communication

Advanced Remote I/O Module

AIAS. Technical description

Infilex VC Variable Air Volume Controller with Actuator for BACnet MS/TP Communication

Infilex FC. Fan Coil Unit Controller for SC-bus Communication. Specifications/Instructions. Overview. Features AB-6567

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Climatix Sales Presentation. Kurt Steiner / xxx-x-xxx

General Specifications

Supervisory Controllers

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

IntesisBox Modbus Server - BACnet/IP Client

BMEP processor module M580 - Level 1 - Distributed

EXOcompact. Freely programmable controller

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

EY-EM : Remote I/O module, ecolink

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

DESCRIPTION OF MODBUS CONNECTION

Decentralised operating and monitoring systems

BACnet Product Overview

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

TM251MESC controller M251 Ethernet CAN

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

TM251MESC controller M251 Ethernet CAN

FX Input/Output (I/O) Modules XM07 and XM14

The Simply Smart Way to Optimize Building Control and Performance

PLC PFC200 Controller PFC200 CS 2ETH RS

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

IntesisBox Modbus Server - LON

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

VCL-TP, Teleprotection Equipment

Paperless Recorder VGR-B100. Series

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

TALON Network Manager- 2 & 6 Express

DIGITAL INDICATING CONTROLLER

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

TM258LF42DT compact base M I/O - 24 V DC - CANopen

Product Specifications

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

TAC Xenta 121-FC Programmable Fan Coil Application

Communicative controller for VAV systems

Andover ContinuumTM. b3850 Series Terminal Controllers

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

LMC058LF42 compact base - 42 I/O - 24 V DC supply

pco sistema programmable controllers Technology & Evolution

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

General Specifications

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

Modbus Server SIEMENS Algorex (printer port)

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM258LF42DT compact base M I/O - 24 V DC - CANopen

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

INTELLIGENT SERVER. Model: BMS-LSV6E

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

RXTP ROOM TEMPERATURE

INTERFACE SPECIFICATION

APOGEE / DESIGO PX-HMI HMI-Touch Panel

Specification Sheet For electronically commutated motors

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

LMC058LF42 compact base - 42 I/O - 24 V DC supply

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

TM241CE24T controller M IO transistor PNP Ethernet

ZN230-24MP-1 MP-BUS

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

Industrial 2-port RS422/485 Modbus Gateway

IMIO100 IMIO105. DDC controllers. Summary

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

PSI-MODEM-SHDSL/SERIAL Copper Extender

Comprehensive User/Group Security Restrict or allow access to myriad of points based on individual or group credentials

CPU module for zone 2 Series 9442/35

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Transcription:

Specifications General SCS (System Core Server) is a controller that integrates DDC (direct digital controller) and RS (remote station), such as PARAMATRIX -III and Infilex series controllers, into BMS (building management system) savic-net FX. SCS is also a B-BC (BACnet building controller) and thus interoperable with other manufacturers (third-party) devices. SCS saves the data, collected by DDC every minute, for 48 hours. (Note that alarm data is excluded.) Regarding ON/OFF data points and status data points, equipment runtime and ON/OFF count are recorded and saved in SCS. Direct input terminals (fire DI, private generation DI, power feeding information DI) are provided on SCS. SCS, in case of power failure, is reliable to receive and save the data, and the BMS therefore can be recovered. SCS conforms to all the applicable standards of CE Marking (Class A). Specifications Item CPU Main storage capacity Max. data points Host system communication Remote units communication Connectable lines Connectable remote units Time backup Rated input voltage Allowable voltage range Allowable ambient condition Dimensions (mm) Weight Grounding condition Note: JIS: Japanese Industrial Standards CE Marking Conformity SCS (System Core Server) Model BCY44100M Specification 32-bit CPU 128MB SDRAM 128MB CompactFlash memory 1,000 points BACnet IP (Ethernet: 10BASE-T/100BASE-TX), 1 channel LC-bus (LonTalk protocol) (LAN cable: compliant with EIA/TIA-568 Category 5 or over (φ0.5 mm 4 poles)), 78 kbps NC-bus (JIS IPEV-S cable (0.9 mm 1 pole)), 4,800 bps Modbus TCP (Ethernet) To communicate with Modbus RTU (RS-485), media converter is required. CPL (RS-485) Media converter is required. 4 lines connectable 100 remote units connectable 72 hours 100 V AC to 240 V AC 90 V AC to 264 V AC 5 C 40 C (in operation) 10 %RH to 85 %RH (non-condensing) 2000 m or lower altitude 100 (W) 106 (D) 140 (H) 1.0 kg 100 Ω or lower ground resistance This product must be installed in a panel cabinet. Besides, the product in the panel cabinet must be out of reach of unauthorized people who are not well-trained for electric facilities. This product complies with the following Electromagnetic Compatibility (EMC) and the Low Voltage Directive (LVD). EMC : EN61326-1 Class A, Table 2 (For use in an industrial electromagnetic environment) LVD : EN61010-1 Overvoltage category II Pollution degree 2 1

Model Numbers BCY44100 Model number Description SCS base model number M 100 V AC to 240 V AC power 0 0 Fixed 0 NC-bus model: 4 NC-bus lines (Applicable to Infilex controllers for IP) 1 Redundant NC-bus model: 4 NC-bus lines 2 LC-bus (LonTalk protocol) model: 4 LC-bus lines (2 channels: 2 lines per 1 channel) 6 NC-bus/Modbus/CPL model: 4 lines 0 DIN rail mount type 1 Sub panel mount type Safety Instructions Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual near by for ready reference. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact Azbil Corporation's sales representative. Azbil Corporation will not bear any responsibility for the results produced by the operators. CAUTION Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. This product must be installed under the operating conditions (power, temperature, humidity, vibration, shock, installation position, atmospheric condition, etc) specified in this manual to prevent product damages. This product must be operated within its rated operating ranges specified in this manual. Failure to comply will cause product damages. Trademark information: Infilex,, PARAMATRIX, and savic-net are trademarks or registered trademarks of Azbil Corporation in Japan or in other countries. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Ethernet is a U.S. registered trademark of Xerox Corporation. Linux is a trademark of Linus Torvalds. LonTalk is a trademark of Echelon Corporation registered in the United States and other countries. 2

AS-906E System Configurations savic-net FX BMS configuration Management Integration Server (MIS) System Management Server (SMS) Client PCs (Web Access via Browser) 3rd Party Intelligent Building Management System Annunciator (ANN) and Graphic Driver (GDR) Data Storage Server (DSS) BACnet/ OPC Server ANN/GDR Line Laser printer Cellular phone for Alarm e-mail or Short Message Service Annunciator Graphic Driver Master (AGM) BACnet IP network Virtual Private Network Client PCs (Web Access via Browser) Antivirus Firewalls Remote Access via telephone line Azbil Corporation Yamatake NC-bus Devices System Core Server (SCS) 3rd Party PLC 3rd Party BACnet Systems** 3rd Party Modbus Devices R series Controllers Infilex series Controllers for IP ** Fire Alarm, Chiller, etc. LC-bus (LonTalk) Infilex GD (Operator Panel Itype Option) Infilex GC (Operator Panel I-type Option) Operator Panel P-type or or UT module or or Operator Panel P-type Infilex AC (Operator Panel I-type Option) UT module PMX-III for Pump/Chiller or or Operator Panel P-type UT module Infilex SC or Infilex VC Infilex FC or LS-bus (LonTalk) Infilex ZM 3rd Party Lon Devices Infilex SC Infilex VC or Infilex FC or Figure 1. System configuration Notes: Azbil Corporation's Model R series controllers communicate with CPL (Controller Peripheral Link, developed by Azbil Corporation) over RS-485. Media converter therefore is required to connect to SCS (BACnet IP over Ethernet). Though SCS directly communicates with Modbus TCP over Ethernet, SCS cannot directly communicate with Modbus RTU over RS-485. Media converter therefore is required to connect to Modbus RTU devices. 3

Items shown in Fig. 1 indicate the devices and protocols configuring the system. See Table 1 for the descriptions. Table 1. Devices and protocols configuring savic-net FX system Item Description AGM Azbil Corporation's Annunciator/Graphic Driver Master ANN Annunciator BACnet Data communication protocol for Building Automation and Control Networks (developed by ASHRAE) DSS Azbil Corporation's Data Storage Server GDR Graphic Driver Infilex AC Azbil Corporation's AHU (air handling unit) controller for LonTalk protocol Infilex FC Azbil Corporation's FCU (fan coil unit) controller for LonTalk protocol Infilex GC Azbil Corporation's multipurpose controller for LonTalk protocol Infilex GD Azbil Corporation's multipurpose data gathering panel for LonTalk protocol Infilex SC Azbil Corporation's AHU (air handling unit) controller for LonTalk protocol Infilex VC Azbil Corporation's VAV (variable air volume) controller with damper actuator for LonTalk protocol Infilex ZM Azbil Corporation's zone manager for LonTalk protocol IP Internet Protocol LC-bus LonTalk protocol Controller bus (provided by Azbil Corporation) LonTalk Communication protocol for LONWORKS network LS-bus LonTalk protocol Sub-controller bus (provided by Azbil Corporation) MIS Azbil Corporation's Management Integration Server Modbus Serial communication protocol for PLC (developed by Modicon) Modbus RTU Modbus protocol over RS-485 (RTU: Remote Terminal Unit) Modbus TCP Modbus protocol over Ethernet (TCP: Transmission Control Protocol) Azbil Corporation's digital user terminal Azbil Corporation's analog user terminal Operator Panel (I-type) Azbil Corporation's Integral type Operator Panel Operator Panel (P-type) Azbil Corporation's Panel-mount type Operator Panel PLC Programmable Logic Controller PMX-III Azbil Corporation's PARAMATRIX -III DDC controller for LonTalk protocol R series controllers Azbil Corporation's single loop controllers SCS Azbil Corporation's System Core Server SMS Azbil Corporation's System Management Server UT module Azbil Corporation's user terminal interface 4

Dimensions Model BCY44100M000 / BCY44100M002 / BCY44100M006 100 106 140 Figure 2. Dimensions (mm): Model BCY44100M000 / BCY44100M002 / BCY44100M006 Model BCY44100M001 (Redundant NC-bus model) 130 106 140 Figure 3. Dimensions (mm): Model BCY44100N001 5

6

7 AS-906E

Specifications are subject to change without notice. Building Systems Company http://www.azbil.com/ Rev.7.0 Sep. 2015 AS-906E H (W03) Printed in Japan. 8