Similar documents
Xceedium Xio Framework: Securing Remote Out-of-band Access

1. IPMI OS Drivers and Open Source Software

BMC Remedyforce Discovery and Client Management. Frequently asked questions

Introduction to Intelligent Platform Management Interface (IPMI)

Initial Setup. Cisco APIC Documentation Roadmap. This chapter contains the following sections:

Integrated Dell Remote Access Controller 7 (idrac7) Version User's Guide

IPMI Configuration Guide

Improving Blade Economics with Virtualization

Server Remote Control External KVM over IP

Configuring and Using AMT on TS130. Lenovo ThinkServer

ELFms industrialisation plans

CommandCenter Secure Gateway

UCS-E160DP Double-wide E-Series Server, 6 core CPU, with PCIe

IPMI View User Guide

Chapter 4. Network Security. Part II

Virtualisation for Oracle databases and application servers

AST2500 ibmc Configuration Guide

McAfee epo Deep Command

Release Notes. Dell SonicWALL SRA Release Notes

OpenNebula on VMware: Cloud Reference Architecture

The Balabit s Privileged Session Management 5 F5 Azure Reference Guide

AST2500 ibmc Configuration Guide

Platform Compatibility... 1 Known Issues... 1 Resolved Issues... 2 Deploying the SRA Virtual Appliance... 3 Related Technical Documentation...

ForeScout CounterACT. Single CounterACT Appliance. Quick Installation Guide. Version 8.0

Server Utilities. Enabling Or Disabling Smart Access USB. This chapter includes the following sections:

HySecure Quick Start Guide. HySecure 5.0

TANDBERG Management Suite - Redundancy Configuration and Overview

Riverbed Technology, Inc. 199 Fremont Street San Francisco, CA Phone Fax

BIG-IP Virtual Edition and Linux KVM: Setup. Version 12.1

CounterACT 7.0 Single CounterACT Appliance

High-Performance Computing Clusters with IPMI

Endpoint Protection with DigitalPersona Pro

CounterACT 7.0. Quick Installation Guide for a Single Virtual CounterACT Appliance

Cisco UCS C-Series IMC Emulator Quick Start Guide. Cisco IMC Emulator 2 Overview 2 Setting up Cisco IMC Emulator 3 Using Cisco IMC Emulator 9

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.6

Installing and Configuring VMware Identity Manager Connector (Windows) OCT 2018 VMware Identity Manager VMware Identity Manager 3.

Automated Deployment Services

OEM FRU TECHNICAL WHITE PAPER

Forescout. Quick Installation Guide. Single Appliance. Version 8.1

idrac 8/7 v User s Guide

Cisco Unified Serviceability

Using Atrium Single Sign-On with TrueSight

Introducing IBM WebSphere CloudBurst Appliance and IBM WebSphere Application Server Hypervisor Edition

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

How Parallels RAS Enhances Microsoft RDS. White Paper Parallels Remote Application Server

VMware Mirage Getting Started Guide

New in Release: Secomea Release 8.0. This document shows the changes from release 7.4 to release 8.0. Version: 1.5, 2018

WhatsConfigured v3.1 User Guide

VMware Mirage Getting Started Guide

Part 1 - Getting Started

AppSense DataNow. Release Notes (Version 4.0) Components in this Release. These release notes include:

Securing VMware NSX-T J U N E 2018

Once all of the features of Intel Active Management Technology (Intel

ZENworks 2017 Out-of-Band Management Reference. December 2016

Cisco Virtual Networking Solution for OpenStack

Deploy. A step-by-step guide to successfully deploying your new app with the FileMaker Platform

Cisco Plug and Play Feature Guide Cisco Services. Cisco Plug and Play Feature Guide Cisco and/or its affiliates.

SSL VPN Reinstallation

Installing the Cisco Unified MeetingPlace Web Server Software

Goverlan Remote Control v7 vs. Microsoft Remote Assistance

Automated Out-of-Band management with Ansible and Redfish

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

10 Steps to Virtualization

Advanced Service Design. vrealize Automation 6.2

HPE ilo Federation User Guide for ilo 5

Habanero BMC Configuration Guide

Load Balancing Censornet USS Gateway. Deployment Guide v Copyright Loadbalancer.org

Installing and Upgrading Cisco Network Registrar Virtual Appliance

VMware Identity Manager Connector Installation and Configuration (Legacy Mode)

Console Redirection on VMware ESX Server Software and Dell PowerEdge Servers

Load Balancing Microsoft IIS. Deployment Guide v Copyright Loadbalancer.org

WIND RIVER TITANIUM CLOUD FOR TELECOMMUNICATIONS

Release Notes for Cisco UCS Platform Emulator, Release 3.1(1ePE1)

Installing the Operating System or Hypervisor

Managing VMware ESXi in the Datacenter. Dwarakanath P Rao Sr Partner consultant 6 th November 2008

Cisco Passguide Exam Questions & Answers

Introducing the Dell TM PAN System

OUR CUSTOMER TERMS CLOUD SERVICES - INFRASTRUCTURE

WHITE PAPER Cloud FastPath: A Highly Secure Data Transfer Solution

NI Linux Real-Time. Fanie Coetzer. Field Sales Engineer SA North. ni.com

Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator

CONFIGURATION MANUAL. English version

Intel Active Management Technology Overview

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

SAML-Based SSO Solution

Security Gateway Virtual Edition

Dell Active Fabric Manager for Microsoft Cloud Platform System 2.2(0.0)

XenServer Release Notes

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

Managing Remote Presence

Windows 2000/XP History, and Data Management

Read the following information carefully, before you begin an upgrade.

PrepKing. PrepKing

Introduction to Virtualization

Setting Up the Server

Implementing VMware vsphere 5 Auto Deploy on the Cisco Unified Computing System

SnapCenter Software 4.0 Concepts Guide

VMware ESX Server 3i. December 2007

Managing Remote Presence

User Security Configuration Guide, Cisco IOS Release 15MT

Transcription:

Remote power and console management in large datacenters A Horváth IT department, CERN, CH-1211 Genève 23, Switzerland E-mail: Andras.Horvath@cern.ch Abstract. Today s datacenters are often built of a large number of commodity hardware components. A number of common tasks including operating system installation, hardware and OS level troubleshooting require low-level control of the machines console and power buttons, yet local physical access is not only impractical and error prone but often impossible. We report on the approach used at CERN for low level remote management of more than 9000 machines in multiple datacenters. CERN-IT-2010-006 11/11/2010 1. Background As of 2010, CERN IT operates four machine rooms, one of which is off site. Commodity PC hardware purchased from several vendors is used, among other tasks, to provide the necessary local disk and CPU capacity as well as to run services for the LHC Computing Grid. With a large number of machines installed and a limited number of system administrators available we have to rely on remote access and automation as much as possible both in everyday activities and in emergency situations. While local machine access is still possible, it is often cumbersome, error prone and slow. New hardware is purchased via competitive tendering and special effort is made to avoid any vendor lock in, so the solution to the remote management problem needed to stay vendor independent and open as well. Other constraints were total cost of ownership and the manpower investment needed to deploy the system. 2. Goals We set the following goals for the infrastructure: ability to turn individual machines on and off, including inducing an orderly OS shutdown if possible ability to query individual machines power status ability to connect to individual machines console, including OS console and BIOS log all console traffic scale up to multiple tens of thousands of nodes strict access control the above functionality must be accessible both by humans and by software (e.g. provide means for automation)

encrypted authentication and console traffic robustness; graceful degradation and easy recovery minimal TCO full integration into the ELFMS 1 toolsuite efficient, minimal user interface All of these goals were achieved (see also the FAQ at section 6.) 3. Use cases 3.1. Use cases for remote console Recovery from configuration or driver errors (i.e. no networking available in the OS) Manual boot (for instance to correct filesystem errors) Console log contains kernel backtraces, useful for debugging Changing BIOS settings where no other tool is available Connecting to disk arrays and other embedded devices that are on a private LAN; remote mass reconfiguration via scripts 3.2. Use cases for remote power control Mass reboot machines (mass reinstallation etc) Orderly emergency shutdown via ACPI 2 signal to OS Mass restart, in the proper order after a power outage or emergency shutdown Reset unresponsive machines (not yet used at CERN) on demand hardware provisioning to be explored, especially together with virtualization 4. Solution 4.1. Underlying technology 4.1.1. Server hardware Our choice of base technology, for both remote console and power control, fell to IPMI 3 because of its general availability, vendor independence and good tool support. An IPMI Baseboard Management Controller (BMC) is usually incorporated in, or can be purchased for very little extra, for most current commodity PC mainboards. The BMC is a hardware device, independent from the main CPU, that can be used to monitor certain aspects of the host machine, control the main power supply as well as to access a virtual serial port presented to the OS and BIOS. In IPMI version 2.0 with RMCP+ support, both authentication and network traffic to the BMC can be encrypted. IPMI is a vendor independent de facto standard implemented by most hardware manufacturers; therefore requiring a working remote IPMI 2.0 connection in all new procurements (including RMCP+ and Serial Over LAN functionality) does not impose significant restrictions on available hardware. On the software side, free open source tools as well as vendor specific tools are available for manipulating IPMI BMC settings. Most BMCs can share the network connection of the motherboard NIC. This feature combined with encrypted network traffic means that our general purpose campus network can 1 Extremely Large Fabric management system, http://elfms.web.cern.ch/elfms/ 2 The Advanced Configuration & Power Interface, see http://acpi.info 3 Intelligent Platform Management Interface, see http://en.wikipedia.org/wiki/intelligent Platform Management Interface

Client (managed) host Power control New password Console session IPMI password DB + Power control server Power control req Configuration (passwords etc) User workstation (or admin cluster) Console headnode Console session (interactive or scripted) Figure 1. Communication diagram of the system components also be used for remote management of the machines, thus removing the need for cabling a management LAN. (Caveat: see also section 5) In our environment, all IPMI BMCs are configured locally from the running operating system at install time via the Quattor 4 framework. Individual, randomized passwords are generated for each BMC and uploaded in a secure manner to a central IPMI password database. The password database is never exposed to the users directly. 4.1.2. Virtual machines and embedded systems Virtual machines are being integrated into the same infrastructure via the API or CLI of the hypervisors. Disk arrays, SAN switches and other equipment that generally does not possess IPMI capabilities can usually be managed over the network via a CLI, telnet or ssh. Since these are not considered highly secure devices, their access is limited to a physically separated private LAN. These private LANs are accessible from a console headnode (see below) used as gateway, and consoles can be accessed transparently via the console system. The low level connection in these cases is usually telnet, but adding any character based protocol to our implementation is trivial. 4.2. Headnodes As of 2010, we install a special headnode, an additional Linux PC for every 500 machines ( client hosts ). This machine is dedicated to the purpose of providing console access, storing console logs and monitoring the console connection. Another function fulfilled by the headnodes, though the details are beyond the scope of this paper, is to provide access and monitoring of embedded on private LAN. Via the Quattor system, each headnode can have access to the IPMI passwords of its clients from the password database. These are stored locally and via a wrapper are used by 4 http://www.quattor.org/, part of the ELFMS toolsuite

an open source console application (conserver 5 ) to establish a permanent connection to each BMC over the network. Addition or removal of a client, as well as a BMC password change or host ACL change, is not disruptive to the running system, i.e. it can be reconfigured online. Console connections are retried and reestablished in case the connection is lost. Users connect to conserver via its CLI client (over SSL) and they are authenticated by their Kerberos5 token. Authorization is done by reusing an existing access control list in Quattor: only those who have root access to a machine are permitted to connect to its console. This eliminates the need of maintaining a separate ACL and leverages the existing system of user groups. The remote console system gives interactive access to the serial console, logs all traffic (even if there s no one connected very useful for capturing kernel backtraces!), and can play back these logs in an interactive session. 4.3. Remote power control An IPMI BMC can control a server s power supply as long as the server is plugged into power, even if the server itself is turned off. The BMC (and therefore our system) can turn machines on or off, induce an ACPI event that most operating systems (including Linux and Windows) interpret as shutdown, or query the current power status. At the moment, remote power control is run through a central server, although it would be possible to use each headnode for the power control of the respective clients. The power control server is stateless and can be restarted without affecting functionality. Users connect to the server via HTTPS (using a command line interface, not a webpage) and are authenticated again by their Kerberos5 token. The same access control mechanism is used as for consoles: those with root access to the node in Quattor have remote control over its power supply.) The server will run the respective commands on the users behalf; a fixed size thread pool enables quick operation on many clients at once even if some of them are unaccessible without overwhelming the server. The same basic infrastructure, but with a special application, is in place for emergency shutdown of a large number of machines in case of a cooling system issue in a machine room. 4.4. Client configuration IPMI Serial Over LAN (SOL) presents a virtual serial port to the operating system; this needs to be configured in Linux as the console device, with the same baud rate as is set up in the BMC. This is done via a Quattor NCM component automatically. Another Quattor component takes care of generating BMC passwords and IP/MAC address, enabling SOL, and applying hardware specific settings. BIOSes can usually be set up to redirect (copy) all BIOS input/output to this serial port as well, thereby making remote BIOS access possible. 4.5. IPMI password database A very simple SQLite 6 database keeps track of two passwords for each BMC, one with OPERATOR privileges (to access the console) and another with ADMINISTRATOR privileges (to control the power supply.) 7 In addition, the BMC IP address is also copied here so that all information needed to access a BMC can be queried with a single database lookup. Passwords are uploaded (or changed) by the ncm-ipmi Quattor component when a new machine is installed, via HTTPS, authenticated both ways via X.509 certificates. Each machine is only allowed to write its own passwords into the database. 5 http://www.conserver.com/ 6 A simple relational database without a server. http://www.sqlite.org/ 7 In practice, many BMCs allow OPERATORs to access power controls as well.

Console headnodes can download the passwords of their own clients only (again via two way X.509 authenticated HTTPS) whereas the remote power control server has local access to the database and runs the power control commands on the users behalf. Should the database be lost, or passwords become compromised, it can be re generated by re running ncm-ipmi on the respective machines. 4.6. Software used In addition to the ELFMS/Quattor toolsuite, the open source conserver and ipmitool 8 suites are used to provide a console access framework and, respectively, to configure and access BMCs; the remote power control service code was developed in house. A wrapper script was written to incorporate ipmitool in conserver without exposing passwords in the latter s configuration file (which can be read by clients) and some packaging changes were also introduced to fit our environment. The same wrapper script takes care of retrying the IPMI SOL connection with some known workarounds should the connection fail. It can also access consoles via other protocols like telnet (see section 4.1.2), and more can be added easily. 4.7. Operation of a large scale system New machines are assigned a headnode before they re first installed, the appropriate fields in Quattor and other databases are filled in, and automatic installation takes care of client configuration. Headnodes are also automatically (and transparently) updated from the Quattor configuration. Similarly, new headnodes can be installed in an automated manner. Management tools are available for moving IPMI clients from one headnode to another; while this severs the console connection for a short while it is almost transparent to the users. This is important for retiring headnodes or, for example, the migration of client machines to a new physical location with a separate network. A separate background process takes the connection information between headnode and clients from Quattor and produces DNS entries similar to <hostname>.headnode.cern.ch which are used by users to connect to consoles. This way, console access depends only on the DNS service, the Kerberos domain controller (KDC) and the given headnode. The first two are essential to any other service at CERN and thus are highly available, and the headnode can be changed easily if needed, as described above. Similarly, remote power management depends only on DNS, the Kerberos KDC and the central power management server which also hosts the IPMI password database. The fact that our system only depends on a minimal number of low-complexity services is important as both console and power control are likely to be accessed in an emergency recovery situation. 5. Issues, known limitations and considerations While technically feasible, in the current Quattor setup it is not possible for headnodes to become clients of each other. Thus, remote console access to headnodes is limited (but remote power control works). A new Quattor schema is proposed to lift this limitation but its implementation will take time and effort. Most modern BMCs offer several additional services such as remote Keyboard Video Mouse (KVM) access (usually over HTTP or VNC protocols), SSH access to the BMC, remote export of USB devices etc. If these BMCs are exposed on a public LAN like at CERN one needs to consider the security implications of allowing so many services, which sometimes have default credentials, to be accessible to the users on the LAN. Disabling such services or closing the network port on the BMC usually requires a special firmware version from the manufacturer. 8 http://ipmitool.sourceforge.net/

While IPMI BMCs can almost always be accessed locally on any new hardware, sometimes it takes long debugging and even firmware upgrades to get remote access (and SOL) working. Some BMCs prefer the same MAC address as the integrated NIC, some have and need their own; ARP replies and SOL must be enabled; BMC users must be enabled to connect and to use SOL; etc. Firmware on BMC, motherboard and (where applicable) enclosures needs to be at the right revision level, and firmware revision strings do not always follow standard version numbering rules. We have established good working relationships with our suppliers as well as with the motherboard/bmc manufacturers directly and we are prepared to work together in getting BMCs to work. Fortunately, this work is mostly successful; with the right firmware and settings most modern BMCs can be got to work. Although ipmitool is available in most Linux distributions, enterprise Linux variants generally carry very old versions and need upgrading, otherwise BMC access may not work. Machines that don t have a text-based console (i.e. those running Windows) can not benefit from a serial console system. Although functionality could be added to access the KVM built into most BMCs for interactive sessions the traditional concept of a console log does not apply to these operating systems. Fortunately, the majority of our systems run Linux. (Remote power control, including ACPI OS shutdown, works fine on Windows.) 6. Frequently Asked Questions Is the system described here usable without ELFMS/Quattor? Certainly! The automated configuration and access control will of course be missing, but by manually configuring clients and headnodes the console system will work fine. Manually issuing power commands (running ipmitool) is also possible. Why don t you use KVM-Over-IP switches? KVM switches provide console output as an image, so logging and automated scripting is not possible. Moreover, the cost of IP-enabled KVM switch is not negligible. Why don t you use remote controlled power distributors? Mainly for cost reasons, but note also that these devices can t send an ACPI signal for an orderly OS shutdown. If need be, however, any device with an API or CLI can be integrated into our system with relative ease. 7. References Console Service documentation: https://twiki.cern.ch/twiki/bin/view/fiogroup/tsiconsole Remote Power Control Service documentation: https://twiki.cern.ch/twiki/bin/view/itproc/kbremotepowercontrol Conserver webpage: http://www.conserver.com/ IPMItool webpage: http://ipmitool.sourceforge.net/