SHD-30E/60E-CT/PCI/EC(SSW) SHD-30E/60E-CT/PCI/FAX(SSW) SHD-120E/240E-CT/PCI(SSW) SHD-120E/240E-CT/PCI/EC(SSW) SHD-120E/240E-CT/PCI/FAX(SSW)

Similar documents
Contents. Contents... i Copyright Declaration... ii Revision History... iii Chapter 1 Overview... 1

SHD-240/480A-CT/cPCI SHD-240/480S-CT/cPCI

DTP-30C/PCI, DTP-30C/PCI+ DTP-60C/PCI, DTP-60C/PCI+ DTP-120C/PCI, DTP-120C/PCI+

SHD-30/60C-CT/PCI. Digital Trunk Voice Board

SHT-2B/USB SHT-4B/USB

ATP-24A/PCI(2.0) ATP-24A/PCI+(2.0) ATP-24A/PCIe(3.0) ATP-24A/PCIe+(3.0) Analog Tap Passive Board

TEJ-1A/PCI TEJ-2A/PCI TEJ-4A/PCI

SHT-2B/USB SHT-4B/USB

SHN-8B-CT/PCI+ SHN-16B-CT/PCI+ SHN-32B-CT/PCI+ SHN-60B-CT/PCI+ SHN-60B-CT/PCIe+ SHN-120B-CT/PCI+ SHN-120B-CT/PCIe+

SHT-16C-CT/PCI/EC(SSW) SHT-16C-CT/PCI/FAX(SSW) Analog Voice Board Special-for-Switch

TEJ100P/TEJ200P TEJ100E/TEJ200E TEJ101P/TEJ201P TEJ101E/TEJ201E

SHT-8B/PCI SHT-8B/PCI/FAX SHT-16B-CT/PCI SHT-16B-CT/PCI/FAX

TEJ400P/TEJ401P TEJ400E/TEJ401E TEJ800P/TEJ801P TEJ800E/TEJ801E

SHT-16B-CT/cPCI 2.0. SHT-16B-CT/cPCI/MP Analog Tap Passive Board. Version 2.1

Synway CTI Series. SHN-480C-CT/PCIe. VoIP Media Processing & Signaling. Version 1.0. Synway Information Engineering Co., Ltd.

FXM-8A/PCI FXM-16A/PCIe

Synway DST Series SHR-24DA-CT/PCI. Digital Station Tap Board. Synway Information Engineering Co., Ltd.

TEJ100P/TEJ200P TEJ100E/TEJ200E TEJ101P/TEJ201P TEJ101E/TEJ201E

DST-24B/PCI DST-24B/PCI+ DST-24B/PCI(2.0) DST-24B/PCI+(2.0) DST-24B/PCIe(2.0) DST-24B/PCIe+(2.0) Digital Station Tap Board

Synway SSW Series FXM3201P(SSW) AST Analog Voice Board. Special-for-Switch. Synway Information Engineering Co., Ltd.

SHR-4D/PCI SHR-4D/PCIe

Synway DST Series SHR-24DA-CT/PCI. Digital Station Tap Board. Version 2.1. Synway Information Engineering Co., Ltd

Synway SSW Series FXM3201P(SSW) AST Analog Voice Board. Special-for-Switch. Version 1.0. Synway Information Engineering Co., Ltd.

SHT-8B/PCI SHT-8B/PCI/FAX SHT-16B-CT/PCI SHT-16B-CT/PCI/FAX. Analog Voice Board

Synway AST Series. FXM32 Full-length. Analog Voice Board. Version 1.0. Synway Information Engineering Co., Ltd.

BRI16 Full-length Board

SSW030A SSW080A SSW080B

CDC-1522A/PCI CDC-2522A/PCI CDC-3522A/PCI. Version 1.0

Synway Voice Board Accessories SH-SPD8B, SH-SPD16B. Lightning-resistant Box. Version 1.0. Synway Information Engineering Co., Ltd.

Synway Voice Board. Synway Information Engineering Co., Ltd.

Synway Voice Board. Synway Information Engineering Co., Ltd.

FXM-8A/PCI FXM-16A/PCIe

Synway Voice Board. Synway Information Engineering Co., Ltd.

Synway Voice Board. Synway Information Engineering Co., Ltd.

SMGREC. SMG Gateway Recording Server

Device Cloud Management System

Elastix Installation Manual

Elastix Installation Manual

Synway SMG Series Wireless Gateway. SMSDemo Program. Synway Information Engineering Co., Ltd.

Synway SIMCLOUD System SIMCLOUD. Version Synway Information Engineering Co., Ltd

Uniway2000 Uniway2100

VP-8LVCT User s Manual First Edition. Copyright 2001, Eletech Enterprise Co. Ltd. All Rights Reserved.

DTP800 Digital Trunk Recording Server

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

SynAST Application Platform-AsteriskNow Installation Manual

SynAST Application Platform-Trixbox Installation Manual

SynAST Application Platform-CallWeaver Installation Manual

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

SMG Integrated Media Gateway. Remove Unclearness, Disconnection and Complexity

Dialogic Blue Telephony Boards

Product Catalog. Asterisk Open-Source. Enabling Technologies

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

Dialogic Blue Telephony Boards

SMG Integrated Media Gateway. Remove Unclearness, Disconnection and Complexity

SCU Series Switch Control Unit

Intel NetStructure HDSI Platform

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

SERVICE MANUAL MODEL SSW-521-D2-ADA

SERVICE MANUAL MODEL SSW-520-F

ADSL Loop Extender AER800-24P

F271XA Fiber-Optic Telephone Modem Technical Manual

Atrie WireSpan 620. User's Manual

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

User Manual MHD44. HDMI Matrix Switcher. All Rights Reserved. Version: MHD44_2014V1.0

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

Installation and Operation Manual VF-30/VF-60. Single/Dual E1 Digital Voice Compression Modules. Megaplex-2100 Version 11 MEGAPLEX-2100 MODULES

Dialogic Diva Analog Media Boards by Sangoma

Installing the Cisco Unified Videoconferencing 3545 MCU

Dell Thunderbolt Dock TB15 User Guide

VisionRGB-PRO User Manual

Host Media Processing E&M Board

User's Guide. Analog Expansion Board for DIGI96/8 Series and Hammerfall Serie 4/8 Channels, 24 Bit

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PJP-25UR Conference Microphone Speaker

CCRecord Professional PRI23 Recording. Application Notes

N-8000 SERIES IP INTERCOM SYSTEM

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

MT-350 Mobile Trunk. Operation Manual. PORTech Communications Inc.

RC702-FX Ethernet over SDH User Manual

Starlink 9003T1 T1/E1 Digital Transmission

U S E R S M A N U A L

PJP-25UR Conference Microphone Speaker

ISDN PABX System. Installation Manual. Profi Line: AS 100 IT

ND (E) ISSUE 2 STOCK # Remote PIM System Manual SEPTEMBER, NEC America, Inc.

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

The SL2100 Quick Install Guide: Terminals Type A (4w)

User's Guide. Analog Expansion Board for DIGI96/8 Series, Hammerfall Series and HDSP /8 Channels, 24 Bit

Operating Instructions. User Guide

RION ORION TELECOM NETWORKS INC. VCL-EC T1 Echo Canceller 1U, 19 inch Version with Telnet. T1, 1U Echo Canceller Product Brochure & Data Sheet

PCM PC/ bit Digital I/O Module. User Manual

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

RS-422/485 PCIe Card

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

Multiplexing (Recap)

Transcription:

Synway SSW Series SHD-30E/60E-CT/PCI(SSW) SHD-30E/60E-CT/PCI/EC(SSW) SHD-30E/60E-CT/PCI/FAX(SSW) SHD-0E/40E-CT/PCI(SSW) SHD-0E/40E-CT/PCI/EC(SSW) SHD-0E/40E-CT/PCI/FAX(SSW) Digital Trunk Board Special-for-Switch Version. Synway Information Engineering Co., Ltd www.synway.net

Contents Contents...i Copyright Declaration...ii Revision History...iii Chapter Overview.... Functions.... Features....3 Operation Principle... 4 Chapter Installation...5. Hardware Structure... 5. System Requirements... 4.3 Installation Procedure... 5 Appendix A Technical Specifications...9 Appendix B Technical/sales Support...0 Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page i

Copyright Declaration All rights reserved; no part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, without prior written permission from Synway Information Engineering Co., Ltd (hereinafter referred to as Synway ). Synway reserves all rights to modify this document without prior notice. Please contact Synway for the latest version of this document before placing an order. Synway has made every effort to ensure the accuracy of this document but does not guarantee the absence of errors. Moreover, Synway assumes no responsibility in obtaining permission and authorization of any third party patent, copyright or product involved in relation to the use of this document. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page ii

Revision History Version Date Comments Version.0 009-0 Initial publication Version. 00-7 Add description on the RSD043 Outlet Board. Note: Please visit our website http://www.synway.net to obtain the latest version of this document. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page iii

Chapter Overview These Synway E-type digital trunk boards are earmarked for PBX. They have almost all functions needed for call/voice processing systems which are connected to them through E/T/J trunks. These boards are designed with the enhanced capability in echo cancellation and the DMA Read and Write function which speeds up the data transfer and minimizes the cost of CPU, further improving the system performance.. Functions A single board accommodates,, 4 or 8 E/T/J trunks Supports China SS, SS7 and ISDN connections in E/T mode Supports phone calling and voice processing Activity/silence detection Automatic Gain Control (AGC) support in recording operation Enhanced echo cancellation Up to 64 fax channels optional on a single board Allows DTMF transmission and detection during voice recording or playback Includes H.0 bus, facilitating smooth connectivity to third-party boards with H.0 bus for the transfer of acquired voice signals to other devices The flexible distributed conferencing system sets no limit on the number of simultaneous conferences and participants in each conference, allows monitoring and recording of the whole conference and each individual speaker Equipped with hot-swap circuits to support board insertion and extraction during runtime, easy for maintenance and backup The on-board lightning-proof circuit reaches the telecom standard and surely eliminates the damage caused by lightning Equipped with the EMI circuit, effectively preventing the electromagnetic interference Each board has a unique hardware serial number written in the firmware to distinguish itself from other boards and prevent piracy. The number is available via an easy function call with applications The on-board authorization code identification circuit is designed for software Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page

safety. Users can apply to our company for the authorization code Compatible with other series of voice boards from Synway. Features DMA Read and Write Uses the DMA technology based on PCI bus to read and write data, greatly reducing the CPU cost. E/T/J Support Provides an easy selection of the E, T or J trunk and its matching impedance via software reconfiguration, not requiring any change in hardware. Signaling Interface SS provides two levels of interfaces respectively for MFC transmission/receipt and SS connection; SS7 provides two levels of interfaces respectively for MTP and TUP/ISUP, meeting various customer requirements. Signaling Processing Installed with loadable signaling processing modules, each board supports SS, SS7 and ISDN, eliminating the need for extra signaling boards. The signaling processing program can be upgraded via a simple software configuration, without having to change the hardware. Signaling Links Each board supports up to 8 signaling links and the signaling hot-backup feature, i.e. the signaling can be processed by the standby server whenever something is wrong with the links being used, which increases the flexibility and reliability in a great extent. All the timeslots ranging from to 3, not only TS6, can be used for SS7 and ISDN signalings. Programmable Tone Detector Detects single or dual tones at any frequency, offering facility for use with a variety of PBXes and key telephone systems. Software-based Terminal Matching A single board supports several kinds of trunks which differ in impedance. They are 00Ω T, 0Ω J and 0Ω E twisted-pair cables and 75Ω E coaxial cable. Both transmit and receive terminals on the board are specified via software configurations, facilitating easy connections to a variety of digital trunks and optical transceivers. Specialized Driver Algorithm Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page

The driver uses SPECDial - a specialized driver algorithm - to perform a complete automatic dial process through digital trunks and to accurately identify the called-party status. Echo Cancellation The self-adaptive echo cancellation feature effectively eliminates echoes under various conditions, which cancels out the effect of voice playback on DTMF and busy tone detection, avoids self-excited oscillation and howling, and minimizes the possibility of registering wrong DTMF and busy tones in a conference call. Among the products introduced in this file, the SHD-30/60E-CT/PCI/EC(SSW), SHD-0/40E-CT/PCI/EC(SSW), SHD-30/60E-CT/PCI/FAX(SSW), SHD-0E-CT/PCI/FAX(SSW) boards have an increased capability in echo cancellation and offer a much better effect in this aspect. A Particular Separation Design As the mainboard and the outlet board are designed independent from each other, when you pull out the mainboard or reinsert it or replace it with other boards, there is no need to reconnect lines as long as the outlet board is not changed or removed. Barge in Supports the Barge-in feature. Various CODECs Support Offers a large selection of voice CODECs, including hardware-based A-Law (G.7), μ-law, IMA ADPCM and software-based 6-bit linear PCM, MP3. Supports WAV File The recorded voice files can be edited and played by audio tools such as Cooledit. Synway s Unified SynCTI Driver Development Platform Synway owns the intellectual property rights for the unified high-intelligence SynCTI driver development platform. Each system supports up to 048 channels. The complex call procedures can be analyzed and controlled through simple function calls on the driver platform, without having to understand details. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 3

.3 Operation Principle TDM Bus Switch Switch and Conference AGC AGC K5 Playback to Bus V3 K4 K3 K6 K Outbound Voice LIU Framer Echo Canceler Inbound Voice AGC K E/T Interface HDLC ABCD Signaling SS7-MTP EC Enhance V V Tone Detector DTMF Detector Barge in Detector Encoder DTMF/Tone Generator Decoder Recording Buffer Playback Buffer Host Computer Interface (PCI ) Figure - Operation Principle of SSW Series E-type Boards Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 4

. Hardware Structure Chapter Installation SHD-30E-CT/PCI(SSW) Mainboard PCI Interface Hot-swap Sync 30E Self-defined Interface Handle with a lock Figure - Right and Front Views SHD-30E-CT/PCI/EC(SSW) Mainboard Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 5

PCI Interface Hot-swap Sync Handle with a lock 30E Self-defined Interface Figure - Right and Front Views SHD-30E-CT/PCI/FAX(SSW) Mainboard PCI Interface Hot-swap Sync 30E Self-defined Interface Handle with a lock Figure -3 Right and Front Views Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 6

SHD-60E-CT/PCI(SSW) Mainboard PCI Interface Hot-swap Sync Handle with a lock 60E Self-defined Interface Figure -4 Right and Front Views SHD-60E-CT/PCI/EC(SSW) Mainboard PCI Interface Hot-swap Sync Handle with a lock 60E Self-defined Interface Figure -5 Right and Front Views Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 7

SHD-60E-CT/PCI/FAX(SSW) Mainboard PCI Interface Hot-swap Sync Handle with a lock 60E Self-defined Interface SHD-0E-CT/PCI(SSW) Mainboard Figure -6 Right and Front Views PCI Interface Hot-swap Sync 3 4 Handle with a lock 0E Self-defined Interface Figure -7 Right and Front Views Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 8

SHD-0E-CT/PCI/EC(SSW) Mainboard PCI Interface Hot-swap Sync 3 4 Handle with a lock 0E Self-defined Interface Figure -8 Right and Front Views SHD-0E-CT/PCI/FAX(SSW) Mainboard PCI Interface Hot-swap Sync 3 4 Handle with a lock 0E Self-defined Interface Figure -9 Right and Front Views Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 9

SHD-40E-CT/PCI(SSW) Mainboard PCI Interface Hot-swap Sync Handle with a lock 3 4 5 6 7 8 40E Self-defined Interface Figure -0 Right and Front Views SHD-40E-CT/PCI/EC(SSW), SHD-40E-CT/PCI/FAX(SSW) Mainboards PCI Interface Hot-swap Sync Handle with a lock 3 4 5 6 7 8 40E Self-defined Interface Figure - Right and Front Views Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 0

SSW E-type Mainboards GXXXXXXX SHD-40E-CT/PCI Serial Number Board Model Figure - Rear View RSD08 Outlet Board IN OUT PCM IN OUT PCM IN3 OUT3 PCM3 IN4 OUT4 PCM4 IN5 OUT5 PCM5 IN6 OUT6 PCM6 IN7 OUT7 PCM7 IN8 OUT8 PCM8 Figure -3 Front View RSD08 Outlet Board Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page

IN IN IN3 IN4 IN5 OUT IN6 OUT IN7 OUT3 IN8 OUT4 OUT5 OUT6 OUT7 OUT8 PCM PCM5 PCM PCM6 PCM3 PCM7 PCM4 PCM8 Figure -4 Right and Front Views RSD04 Outlet Board IN OUT PCM IN OUT PCM IN3 OUT3 PCM3 IN4 OUT4 PCM4 Figure -5 Right and Front Views RSD043 Outlet Board PCM PCM IN OUT IN OUT IN3 OUT3 IN4 OUT4 PCM3 PCM4 Figure -6 Right and Front Views Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page

IN OUT 3 IN 4 5 MIC SPK PWR OUT IN OUT 6 IN 7 3 3 OUT 8 4 4 RSD08 Rear Panel RSD04 Rear Panel RCU&RSD08 Composite Rear Panel RSD043 Rear Panel Figure -7 Rear Panels associated with Outlet Boards Notes: Both RSD08 and RSD043 outlet boards are full-length, while RSD08 and RSD04 outlet boards are half-length. All kinds of rear panels are made of metal and with U-shaped cross sections. 3 The RSD08 rear panel can work only with the RSD08 outlet board. 4 The RSD043 rear panel can work only with the RSD043 outlet board. 5 The RSD04 and RCU&RSD08 rear panels can work only with half-length outlet boards. Remarks: Here above illustrates the hardware structure of Synway E-type boards which are used exclusively for PBX. Always check the label on the back of a board to get the exact board model. See Table - below for detailed information about the synchronization indicators of on-board trunk interfaces mentioned above. LED Lamp Status Implication Green Lamps ON OFF Flash synchronous asynchronous synchronous but unsteady Table - On-board Synchronization s Hot-swap Lamp Status Runtime Status Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 3

Blue Lamp ON OFF in the course of hot-swap normal Table - Hot-swap 3 Interfaces on outlet boards are all RJ48C connectors. Users may convert them into BNC connectors by using the RJ48C-to-BNC adapter supplied with the board. Board models introduced in this file are all listed below. No. Model Trunk SHD-30E-CT/PCI(SSW) E/T/J SHD-30E-CT/PCI/EC(SSW) E/T/J 3 SHD-30E-CT/PCI/FAX(SSW) E/T/J 4 SHD-60E-CT/PCI(SSW) E/T/J 5 SHD-60E-CT/PCI/EC(SSW) E/T/J 6 SHD-60E-CT/PCI/FAX(SSW) E/T/J 7 SHD-0E-CT/PCI(SSW) 4E/T/J 8 SHD-0E-CT/PCI/EC(SSW) 4E/T/J 9 SHD-0E-CT/PCI/FAX(SSW) 4E/T/J 0 SHD-40E-CT/PCI(SSW) 8E/T/J SHD-40E-CT/PCI/EC(SSW) 8E/T/J SHD-40E-CT/PCI/FAX(SSW) 8E/T/J Associated Outlet Board RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD04 RSD043 RSD08 RSD08 RSD08 RSD08 RSD08 RSD08 Physical Interface common RJ48C L9 common RJ48C L9 common RJ48C L9 common RJ48C 4 L9 common RJ48C 4 L9 common RJ48C 4 L9 4 common RJ48C 8 L9 4 common RJ48C 8 L9 4 common RJ48C 8 L9 8 common RJ48C 4 special RJ48C 8 common RJ48C 4 special RJ48C 8 common RJ48C 4 special RJ48C Table -3 Board Model List. System Requirements Host System Requirements CPU: 300MHz Intel Pentium Ⅱ or above Memory: 56M or more Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 4

HD: Depends on individual requirements Supported Operating Systems Refer to SynCTI Programmer s Manual.pdf..3 Installation Procedure Step : Configure the grounding jumpers. Disconnect all grounding jumpers for use of the 00ΩT, 0ΩJ or 0Ω E balanced twisted-pair cable. In consideration of various line conditions, this series boards are equipped with two groups of grounding jumpers on each channel which respectively control the groundings of the transmitting and receiving ends. In case the 75Ω E unbalanced coaxial cable is used, the grounding jumpers at the receiving end should be disconnected while those at the transmitting end should be short-circuited, provided that the PC is properly grounded. This configuration is the factory default setting and applicable to most situations so that there is usually no need to change it. If it is difficult to ground the local PC, you may short-circuit the on-board grounding jumper at the receiving end and use the transmitting end at the opposite terminal for grounding. If the receiving end at the opposite terminal is grounded (improper operation), the on-board grounding jumper at the transmitting end must be disconnected. Refer to Table -4 for details. Generally speaking, even in the case of proper grounding at both terminals, only the external layer of the E coaxial cable at the transmitting end is allowed to be grounded. The grounding of both transmitting and receiving ends may result in a current loop with ground wires, bringing instability to signals. Therefore, such grounding must be strictly avoided. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 5

Opposite Terminal Transmit End grounded grounded non-grounded non-grounded Local Terminal Receive End non-grounded grounded non-grounded grounded PC grounded Transmit End short-circuited disconnected short-circuited disconnected Receive End disconnected disconnected short-circuited short-circuited PC not grounded Transmit End short-circuited short-circuited manage to short-circuited make the PC Receive End short-circuited disconnected grounded short-circuited Table -4 Configuration of Grounding Jumpers for Use of 75ΩE Unbalanced Coaxial Cable Step : Properly fit the required mainboard and outlet board into the Synway PBX. Insert the mainboard and outlet board into a pair of vacant slots on the Synway PBX. With the mainboard completely inserted, push the upper and bottom handles inwards at the same time until a click sound is heard. The board is now properly fitted. Insert the outlet board properly into the slot on the back of PBX which corresponds to the mainboard. Push it home and then fasten the corresponding rear panel by two screws (on the upside and underside of the rear panel). Notes: It is necessary to push the board home into the slot until it can go no further, and ensure that it is not inclined at an angle before applying lever action on the handles to secure it. Such problems as poor contact of boards, blue lamp always on which implies the board abnormality, or damages on connecting parts of the PBX may be caused if: (I) Handles are used too early (II) Handles are used while the board is inclined (III) Force on handles is not applied evenly. Board is allowed to be inserted when the computer is at power on. However, as strong static electricity may lead to damages, the operator should touch a grounded conductor to discharge the static electricity on him before inserting the board. Step 3: Connect the outlet board to digital trunks. Among these four models of outlet boards illustrated in Figure -7, RSD043 provides L9 connectors especially for users to connect with L9 coaxial line; RSD08 and RSD04 provide common RJ48C connectors to support direct connections to other boards, the pin layout being shown below in Figure -8; RSD08 provides special RJ48C connectors, the pin layout being unfolded below in Figure -9. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 6

Transmit Receive TTip TRing RTip RRing 8 7 6 5 4 3 Figure -8 Pin Layout for Common RJ48C Connect to nd Trunk Receive Transmit RTip RRing TTip TRing Connect to st Trunk Transmit Receive TTip TRing RTip RRing 8 7 6 5 4 3 Figure -9 Pin Layout for Special RJ48C You can use the -way hub for RJ48C to convert each special RJ48C connector into common RJ48C connectors as shown in Figure -0: connect the st, nd, 4 th, 5 th pins of the special 8-pin RJ48C connector to the st, nd, 4 th, 5 th pins of the first common RJ48C connector, and the 3 rd, 6 th, 7 th, 8 th pins to the st, nd, 4 th, 5 th pins of the second common RJ48C connector. Besides, you are allowed to construct lines for conversion by yourself, but must follow the order in pin connection as specified above. Figure -0 -way Hub for RJ48C If the input line has a BNC coaxial interface, for boards with common RJ48C connectors, use the RJ48C-to-BNC adapter as shown in Figure - to convert the RJ48C connector to the BNC connector; for boards with special RJ48C connectors, use the -way Hub for RJ48C to convert a special RJ48C connector to two common RJ48C before using the RJ48C-to-BNC adapter. Figure - RJ48C-to-BNC Adapter If you would like to construct lines for BNC or L9 conversion by yourself, you should not only make the line match the on-board interface, but also ensure the correct connection of receive and transmit lines as shown in Figure -8. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 7

Notes: Prevent the cross connection of transmit and receive lines. Such mistake can be found out by observing the on-board synchronization indicators. If the indicator is on, that means the receive line is in a normal state; if the indicator is off or flashing, that means the receive line goes abnormal (probably due to the cross connection). However, the state of transmit lines cannot be checked via synchronization indicators but should be examined by the opposite terminal. On-board synchronization indicators start working only after the PC is powered on and the board is successfully initialized. Step 4: Boot your computer and install the driver. Regarding driver installation, refer to SynCTI_InstManual.pdf. Step 5: Configure parameters for the digital trunk board. Refer to SynCTI Programmer s Manual for details. Key Tips: As the system is expected to run for long hours unmannedly, energy-saving mode should be turned off for both the CPU and the HD in CMOS or WINDOWS operating system. This is to ensure full-speed operation of the computer, or it may lead to a drop in performance or unexpected errors after running for some time. A chassis installed with voice boards must be grounded for safety reasons, according to standard industry requirements. A simple way is earthing with the third pin on the plug. No or improper grounding may cause instability in operation as well as decrease in lightning resistance. Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 8

Appendix A Technical Specifications Dimensions (excluding L-bracket) Mainboard: 8.6 74.5mm Full-length outlet board: 80 5.mm Half-length outlet board: 90 5.mm Weight Main board: 50g Full-length outlet board: 75g Half-length outlet board: 75g Environment Operating temperature: 0 55 Storage temperature: -0 85 Humidity: 8% 90% non-condensing Storage humidity: 8% 90% non-condensing Input/output Interface E physical ports: Compliant with G.703, including 75Ω unbalanced interface and 0Ω balanced interface T /J physical ports:dsx- and CSU line build-outs available for different extents of signal losses, including 00Ω and 0Ω balanced interfaces Audio Specifications CODEC: CCITT A/µ-Law 64kbps, Distortion: 3% Frequency response: 300-3400Hz (±3dB) Signal-to-noise ratio: 38dB Echo suppression: 40dB Maximum System Capacity Up to 8 digital trunk boards concurrently per system; up to 40 channels per board Echo Cancellation SHD-30E/60E-CT/PCI/EC(SSW): 64ms SHD-30E/60E-CT/PCI/FAX(SSW): 64ms SHD-0E/40E-CT/PCI/EC(SSW): 64ms SHD-0E-CT/PCI/FAX(SSW): 64ms Power Requirements Maximum power consumption: 0W Signaling SS: compliant with DL and MFC standards stipulated in GF00-900; supports D4 and ESF framing SS7: compliant with Q77-Q795 DSS: compliant with Q.933 Audio Encoding & Decoding 6Bit PCM 8kbps 8Bit PCM 64kbps A-Law 64kbps µ-law 64kbps IMA ADPCM 3kbps GSM 3.6kbps MP3 8kbps Safety Lightning Resistance: Level 4 Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 9

Appendix B Technical/sales Support Thank you for choosing Synway. Please contact us should you have any inquiry regarding our products. We shall do our best to help you. Headquarters Synway Information Engineering Co., Ltd http://www.synway.net/ 9F, Synway D&R Center, No.3756, Nanhuan Road, Binjiang District, Hangzhou, P.R.China, 30053 Tel: +86-57-8886056 Fax: +86-57-8885093 Technical Support Tel: +86-57-88864579 Mobile: +86-373554965 Email: techsupport@sanhuid.com Email: techsupport@synway.net MSN: scycindy_sh@hotmail.com Sales Department Tel: +86-57-8886056 Tel: +86-57-88864579 Fax: +86-57-8885093 Email: sales@synway.net Synway SSW Series E-type Digital Trunk Boards Hardware Manual (Version.) Page 0