Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Similar documents
Ground Monitoring Device Series 8485

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485

Terminal Boxes Series 8118

Micro Limit Switch Series 8064

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Load Disconnect Switches and Motor Switches

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Position Switches Series 8070

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Control Buttons / Switches for Panel Mounting Series 8003

Tubular Light Fitting with LED Series 6036

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Miniature Circuit-Breaker IEC Series 8562

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Cable End Boxes Series 8146

Linear Luminaire with LED Series 6412/5

Control Switches for Panel Mounting Series 8003

Linear Luminaire with LED Series 6012/5

5 Fieldbus Technology

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

CPU module for zone 2 Series 9442/35

INSTALLATION TECHNOLOGY MADE EASY

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Technical Data. General specifications. Rated operating distance s n 3 mm

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

PI-EX-ME-2NAM/COC-24VDC

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

PI-EX-ME-2NAM/COC-120VAC

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

SolConeX Wall-Mounted Socket, 16 A

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

PHOENIX CONTACT - 12/2007

Capacitance level switches LS 210 LS 220

Loads and Motor Switchgears

MACX MCR-EX-SD LP(-SP)

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

FLEX Ex Spring Clamp Terminal Base

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Product manual plug, sockets and coupler 16 A.- Z0251

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP)

Inductive sensor BI1.5-EG08-Y1-H1341

PHOENIX CONTACT - 02/2008

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Reed sensor For bypass level indicators Model BLR

PHOENIX CONTACT - 01/2008

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor BI5-EM18-Y1X-H1141

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Threaded resistance thermometer Miniature design Model TR10-D

SolConeX extra-low voltage flange socket

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

General Specifications

Inductive sensor with analog output BI15-M30-LI-EXI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Safety switches with separate actuator

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Isolating repeater IRU 420

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Flow Measurement SITRANS F C

Intrinsically Safe Explosion Proof Barriers

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Throughwiring. single-ended. twin-ended

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Technical Information Promonitor NRF560

HERION SERIES Indirect solenoid actuated spool valves

M E M O R A N D U M I.S.

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Supplementary Components WirelessHART products

Resistance thermometer With spring-loaded tip Model TR55

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Magnetic float switch For vertical installation Model FLS

Transcription:

www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or stainless steal enclosure (IP66) > Easy installation and operation > Potential-free contact for signalling to the process control system and external control devices > Insulated point of suspension > For use up to SIL 2 (IEC 61508) 14834E00 The ground monitoring device ensures that tank containers and drums are correctly electrostatically grounded during the loading of flammable liquids. The device provides a conductive connection to the ground and monitors in parallel the quality of the electrostatic grounding. This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy discharge. The following recommendation requires grounding during loading and recommends interrupting loading in case of incorrect grounding: > CENELEC LC/TR 50404 recommendation for avoiding ignition hazards due to electrostatic charges. > TRBS 2153 for avoiding ignition hazards as a result of electrostatic charges ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x x x For use in x x x x WebCode 8146H Control Devices /1

Selection Table Version Description Art. no. Weight Ground monitoring device series 8146/5075 without cable. The ground monitoring device ensures that drums and tank containers are correctly electrostatically grounded and continuously monitors the connection. kg 136216 5.800 12753E00 Ground monitoring device 8146/5075 Ground monitoring device series 8125/5071 without cable. The ground monitoring device ensures that drums and tank containers are correctly electrostatically grounded and continuously monitors the connection. For use up to SIL 2. 209056 6.500 14728E00 Ground monitoring device 8125/5071 10 m cable with robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6. *) 105536 1.900 12056E00 with cable 5 m of cable with robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6 10 m of cable with robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6. 105538 1.350 105539 1.900 12055E00 with spiral cable Automatic winder with 15 m of insulated cable and robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6. Self retracting reel with 15 m Hytrel isolated cable 105544 16.000 12715E00 with automatic cable winder Robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6. 203148 0.800 09003E00 Note *) Special cable length possible on request. Price and date of delivery differ from the standard. /2 Control Devices

Explosion Protection Global (IECEx) Gas and dust IECEx PTB 06.0090 IECEx PTB 06.0079 Ex d e [ia] IIC T4 Ex d e [ia] IIC T4 Ex td A21 IP66 T80 C Ex td A21 IP66 T80 C Europe (ATEX) Gas and dust PTB 01 ATEX 1024 PTB 00 ATEX 3116 E II 2 G Ex d e [ia] IIC T4 E II 2 G Ex d e [ia] IIC T4 E II 2 D Ex td A21 IP66 T80 C E II 2 D Ex td A21 IP66 T80 C Certificates and approvals Certificates IECEx, ATEX, Brazil (UL do Brasil), Russia (GOST-R), Belarus (GOST-B) Other approvals ship approval (DNV) ship approval (DNV) Further parameters Installation in Zones 1, 2, 21, 22 in Zones 1, 2, 21, 22 IECEx, ATEX, Brazil (UL do Brasil), Russia (GOST-R), Belarus (GOST-B) Technical Data Electrical data Power supply Rated voltage 120 / 230 V Nominal voltage range 96... 253 V AC Frequency range 48... 62 Hz Rated current 50 ma Power consumption 3 VA Cable diameter range 6... 13 mm of cable gland (M20) Output Signalling contact potential-free NO contact (Ex e) Maximum load AC 250 V / 4 A Maximum load DC 250 V / 2 A 40 V / 3 A Minimum load 12 V / 100 ma LED display Operating principle: State of grounding process Clamp is not connected, grounding equipment not in use Reaction of the ground monitoring device Grounding incorrect Red indicating lamp ON Green indicating lamp OFF Contact OPEN 10938E00 Clamp connected to tank container or drum. Grounding ok Red indicating lamp OFF Green indicating lamp ON Contact CLOSED 08030E00 Functional safety (IEC 61508) Test report applied for Max. SIL 2 Safe state relay released / no release Safe Failure Fraction SFF 69 % PFD AVG at T [Proof] T[Proof] 1 year 2 years 5 years PFD AVG 3.83 x 10-4 7.3 x 10-4 1.77 x 10-3 Control Devices /3

Technical Data Ambient conditions Ambient temperature - 20... + 55 C Storage temperature - 40... + 80 C Mechanical data Degree of protection IP66 IP66 Material Enclosure Glass-fibre-reinforced polyester resin, Stainless steel (1.4404 (AISI 316L) flame-resistant Stainless steel with sharp non-wear contact points made of tungsten carbide Stainless steel with sharp non-wear contact points made of tungsten carbide Cable diameter range 6... 12 mm 6... 12 mm of cable gland (M25) Weight 5.8 kg 6.5 kg Assembly / Installation Connection grey & green/yellow blue Connection single-wire - rigid - flexible - flexible, cable end sleeves with plastic cover - flexible, cable end sleeves without plastic cover 0.2... 6 mm 2 0.2... 4 mm 2 0.25... 2.5 mm 2 0.25... 4 mm 2 0.2... 4 mm 2 0.2... 2.5 mm 2 0.25... 1.5 mm 2 0.25... 2.5 mm 2 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 190 mm / 7.48 " 16 mm / 0.63 " 230 mm / 9.06 " 213 mm / 8.39 " 114 mm / 4.49 " 91 mm / 3.58 " 9,5 mm / 0.37 " 242 mm / 9.53 " 152 mm /5.98 " ø 7 mm / 0.28 " 136,5 mm / 5.37 " 25 mm / 0.98 " 377 mm / 14.84 " 7 mm / 0.28 " 9 mm / 0.35 " 288,5 mm / 11.36 " 340,5 mm / 13.41 " ~ 414 mm / ~ 16.30 " ~ 436 mm / ~ 17.17 " 399 mm / 15.71 " 360 mm /n 14.17 " 340 mm / 13.39 " 396 mm / 15.60 " 28 mm / 1.10 " 148 mm / 5.83 " 170 mm / 6.69 " 08029E00 156,5 mm / 6.16 " 176,5 mm / 6.95 " Grounding monitoring device 8146/5075 Grounding monitoring device 8125/5071 14867E00 /4 Control Devices

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 380 mm / 14.96 " 192 mm / 7.56 " ø 10 75 mm / 2.95 " 112 mm / 4.41 " Cable drum with automatic cable winder 04878E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Control Devices /5