Geometry Measurements

Similar documents
Welcome to our world.

Welcome to our world.

Welcome to our world.

Welcome to our world.

Single-Axis Lasers for Flatness and Leveling Applications. Laser Systems for Flatness and Leveling L-730/L-740 Series

E950 BORE ALIGNMENT. Straightness measurement of bore and bearing journals HIGH PRECISION WARRANTY

E960 TURBINE ALIGNMENT. Straightness measurement of diaphragms and bearing journals HIGH PRECISION WARRANTY

E950 BORE ALIGNMENT. New detecto. Straightness measurement of bore and bearing journals HIGH PRECISION WARRANTY

XT660. Alignment system for all important steps of machine installation. Shaft Alignment

Aligning Parallelism of Rolls Has Never Been Faster. L-732 Precision Dual-Scan Roll Alignment System

XT660. Alignment system for all important steps of machine installation. Shaft Alignment

XT660. Alignment system for all important steps of machine installation. Shaft Alignment

E710 / E720. Machine Alignment and Installation E710 / E720

S-650 Coupling Alignment System

Alignment Software for Linear Guides

OPTALIGN smart RS5 The power of precision shaft alignment

OPTALIGN smart RS5 The power of precision shaft alignment

XT550. Intrinsically safe for potentially explosive environments. Shaft Alignment

CONTENT USER MANUAL MEAX, edition 4.0 (March 2017)

High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any

High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any

Aligning Continuous Casters and Steel Mill Rolls

XT550. Intrinsically safe for potentially explosive environments. Shaft Alignment

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

Alignment Software for Bearing Ways and Bores

Methods and Instrumentation for the measurement of Machine Tools (according to ISO 230 and ISO 1101)

ЗАО «БЕРГ АБ», (495) , Intrinsically safe shaft alignment tool with printer

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS

Bore Alignment. Extruder Alignment. Application Notes

Stealth SerieS. Shaft alignment SyStemS S-660CRT & S-660T WIRELESS 3-AXIS

Machine Tool Alignment Boring Mills, Gantries, Machining Centers, VTLs

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S T W I R E L E S S 5 - A X I S

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S - 670CRT & S - 670T W I R E L E S S 3 - A X I S

XT660 Alignment system for all important steps of machine installation. Shaft Alignment IP66 IP67

XL-80 spares list. Application note. Overview

SP ProLine 30. Straightness Professional Package with IT. Another fine solution by PC /13

Machine Geometry Measurement

Electronic angle measuring machine. Angle/position by means of vignetting

SHAFTALIGN OS3 The efficiency of laser shaft alignment

Up to 50% of all costs related to rotating machinery breakdowns is caused by shaft misalignment

USER MANUAL Fixturlaser NXA

E540. Shaft Alignment E540

SHAFT ALIGNMENT. Compact size! Professional measurement and alignment system for rotating machines.

We Make It Easy! PRODUCT CATALOGUE. Version Rev 12. Released 5 June Precision laser measurement systems

QUICK START 40 MIN. ROTATION ENTERING SHAFT ALIGNMENT. Professional measurement and alignment system for rotating machines

Laser Systems for Geometric Alignment L-730/740 Series

Laser Systems for Geometric Alignment L-730/740 Series

A U T O C O L L I M A T O R S

STEALTH SERIES TM S T WIRELESS 5 -AXIS SHAFT ALIGNMENT SYSTEMS

Parallel Roll Alignment Software

Elos Fixturlaser AB. Generator alignment

Stealth SerieS. Shaft alignment SyStemS S-680BT WIRELESS 5-AXIS

Fixturlaser SMC Balancer. QUICK TIPS Fixturlaser SMC BALANCER

Alignment. Reduce machinery breakdowns and increase your uptime. What is shaft misalignment? Accurate shaft alignment really matters

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

CALIBRATION. Sylvac Dial Gauge Calibrator

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

SHAFTALIGN Redefining the standard of laser shaft alignment

E710 / E720. Machine Alignment and Installation THE TOTAL ALIGNMENT SOLUTION. E710 / E720

Fast, Easy and Highly Accurate Extruder Alignment. L-705 Laser Borescope Alignment System for Extruders

EI- Shaft Alignment System

NEW - Quick Mode - The revolutionary way to simplify measurement!

CENTRALIGN Ultra RS5 Alignment of bores, bearings and diaphragms

OPTALIGN smart EX Maintaining high standards in machinery alignment

USER MANUAL MEAX Coaxiality

Stealth SerieS. Shaft alignment SyStemS S-680T WIRELESS 5-AXIS

USER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model

Straightness measurement

ROTALIGN touch Precision Meets Connectivity

ROTALIGN Ultra is The Alignment intelligent System

ND 1202 ND 1203 ND monochrome flat-panel display for position values, dialogs and inputs, graphics functions and soft keys

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

Leica Rugby 810, 820 & 840 The toughest construction lasers on site

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Leica Rugby 810, 820 & 840 The toughest construction lasers on site

OPTALIGN smart RS The Real Sense in machinery alignment

Rugged and waterproof, plus high-power telescope with superior Nikon optics

SKF Shaft Alignment Tool TKSA 31

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

Fixturlaser SMC Supervisor QUICK TIPS. Fixturlaser SMC

ND 1300 QUADRA-CHEK the Digital Readouts for Convenient 2-D Measurement

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

ROTALIGN touch Precision Meets Connectivity

ROTALIGN touch Precision Meets Connectivity

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

BENCHMIKE 283 SERIES. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

MICRO-HITE 350 / 600 / 900 Height Gages MICRO-HITE main instruments 350 / 600 / 900

Compact Cladding Cell

HDV300 HE400 HB400 HD400 HF600 HF750 VB400 VF600

ROTALIGN Ultra. Highest standards in machinery shaft alignment

A NEW LASER FOCUS ON PATIENT SAFETY

SKF Shaft Alignment Tools

ACCESSORIES FOR SAFETY DEVICES

Binoculars. with. Digital Compass. Instruction Manual. Model: Lit. #: /08-12

IOS I-PHONE Version. I-PHONE is a registered trademark of Apple Corp.

QC20-W wireless ballbar system description and specifications

Alignment Tester FLZ. The FLZ aligment tester is a transportable microscope for the alignment of machine guides. Technische Mikroskopie.

UNIT IV - Laser and advances in Metrology 2 MARKS

Transcription:

Geometry Measurements

Welcome to our world Since the very beginning in 1984, ACOEM AB has helped industries throughout the world to achieve more profitable and sustainable production. We have reached where we are today by having the courage to think beyond the norm and follow slightly unconventional paths. We have had the courage to make mistakes and find new directions. Through our resolve, ambition and knowledge we have become a global player and a leader in innovative, user-friendly shaft alignment. Fixturlaser NXA Geometry The Fixturlaser NXA Geometry package is characterized by its user friendliness and versatility. It contains software for straightness and flatness measurements, such as: Standard straightness for measurement of e.g. machine beds, guideways or support structures. Straightness for full and half bore applications when measuring e.g. bearing journals for compressors and turbines with split casings. All these straightness measurement methods are available to you during the entire measurement process; e.g. if you start by measuring one point as full bore, you can choose to measure the next one as either standard straightness or as half bore. Flatness measurements of foundations and machine beds when installing machines. Measurements on foundations can be done with both rectangular and circular configurations. User Friendly Graphic User Interface The graphic user interface is intuitive and 3D animated, with icons and color coded symbols to guide you throughout the measurement and adjustment process. Live and Micron Resolution Values You have live values during measurement and simultaneous live adjustment, in both vertical and horizontal orientation (X and Y values), during the adjustment process. Measurement results are displayed in micron resolution. Green Benefits Precision geometric measurements will result in fewer unplanned stoppages and correctly installed machinery will result in lower operating costs. By minimizing wear, production stoppages and costs, you will also contribute to a more sustainable environment!

Fixturlaser NXA Geometry Some features relating to the geometry applications are: Best Fit: You have the option to allow the system to calculate a reference line or plane, which illustrates the best fit, i.e. the least deviation for each measurement point in relation to the reference line or plane that has the least deviation of the measurement points. Express Navigation: When you select which points to measure, you will find that the highlighted measurement point is surrounded by its neighbor points enabling you to choose them without exiting the measurement screen. Use of Reference Sensor: With an additional sensor, you can use it as a reference sensor and zero it at the start of the measurement process. You are then able to control, without exiting the measurement screen, that the transmitter has not been moved during the actual measurement, which would cause incorrect measurement values. The Touch and Release: The system gives you full freedom to record your measurements in any order you want. The touch and release function makes it easy to select the point to measure. Touch the screen, slide your finger across the display and release the finger at the point you want to measure. Together with the color screen and the graphical interface, you can very quickly manoeuver in your configuration even if many measuring points have to be registered.

Geometric Applications Straightness The straightness application is measured in two axis, where the laser beam is used as reference. The deviation in distance between the laser beam and the measurement object is measured in two or more positions with the use of a receiver. The program allows for up to 99 points to be measured. Typical applications are measurements of machine guides, machine beds, machine ways, and guide rails. Flatness Typical applications are measurements of e.g. machine beds and machine foundations. For the latter application, it is particularly beneficial to combine flatness measurement with shaft alignment when installing rotating machinery. First you check the foundation s surface for possible irregularities, a so called pre-alignment check. If any, adjust these. Install the machine and check for possible misalignment with a laser based shaft alignment tool like the Fixturlaser NXA system. The program allows for up to 150 points (10 x 15) to be measured. Flatness This application uses a laser plane as reference. The deviation in distance between the laser plane and the measurement object is measured in one or more positions with the use of the receiver. The program allows for up to three circles with 99 points on each circle to be measured. A typical application is the measurement of flanges and machine foundations

Geometric Applications Straightness the Clock In the straightness measurement programs, straightness can be measured in two axes. The laser beam is used as reference and the deviation in distance between the laser beam and the measurement object is measured in two or more positions, with the use of the receiver. The laser beam is set roughly parallel to a surface or an object. Up to 99 measurement points can be recorded by moving the receiver in different positions along the measurement object. The straightness of the object can be evaluated by choosing two points as reference or making a best fit calculation. The measurement can be made as a single or dual axis measurement. Straightness with the Clock Method the Clock Method Straightness with the clock method is used to determine the center position of full bores, horizontally or vertically. The laser beam is set roughly to the center line and each bore center is measured by rotating the receiver 180 degrees in each bore. Typical applications are bore measurements of bearing journals in diesel engines, compressors or gear boxes. Straightness with the Arc Angle Method Straightness with the Arc Angle method is used to determine the center position of full or half bores, with a horizontal center line. The laser beam is set roughly to the center line and each bore center is measured by rotating the receiver in three or up to nine positions in each bore. Typical applications are straightness measurements in bearing journals for e.g. compressors, turbines or machinery with split casings.

The Fixturlaser NXA Geometry Packages The Fixturlaser NXA Geometry Basic and Full packages include the following software: Standard straightness for measurement of e.g. machine beds, guideways or support structures. Straightness for full and half bore applications when measuring e.g. bearing journals in gear boxes, diesel engines, compressors, and turbines with split casings. Flatness measurements, both rectangular and circular, of foundations and machine beds when installing machines. FIXTURLASER NXA Geometry Basic FIXTURLASER NXA Geometry Full Complete the package with a choice from these 4 transmitters T21 The 21 laser transmitter is battery powered. The laser transmitter has a built-in angular prism in a turret allowing the creation of a 360 laser plane. Laser beam levelling can be made in the X and Y coordinates. The turret can easily be detached giving a laser beam perpendicular to the X-Y plane. T110 Battery powered laser transmitter with built-in micrometer screws for adjustment of the laser beam in horizontal and vertical level. T220 Battery powered laser transmitter of diode type with built-in spirit levels and an angular prism. It is equipped with micrometer screws for adjustment of the laser beam in horizontal and vertical level. The optical head can be rotated 360 in order to project a reference plane with the laser beam. T111 Laser transmitter with built-in micrometer screws for adjustment of the laser beam in horizontal and vertical level. The T111 is powered by the supplied AC-adapter (110/230 Volts). Fixturlaser RS sensor unit A reference receiver, a second receiver, is used in applications where you want to check that the reference, the laser beam, has not moved during the measurement sequence. The reference receiver is normally mounted at far distance from the laser transmitter to more easily detect any movements of the laser. When the laser beam is adjusted to its final position and the reference is established, the values from the reference receiver are set to zero in the Sensor Display. It is possible, at any time during the measurement, to enter the Sensor Display and check that the values are still zero.

Bore Fixture Kits Two different fixture kits are available for full and half bore measurements with the Fixturlaser NXA Geometry package. Each kit contains fixtures for various bore diameters, ranging from ø80 mm up to ø1600 mm. Accessories XY table Bracket for fine adjustment of the laser transmitter 1. 2. 3. 3 long arms with magnets for XY table, ø300-600 mm Long arms for XY table 4. 5. 6. 7. XY table including long arms Centering bracket for laser transmitter during bore measurement 9. 8. 10. 1. Fixture, RM/RS bore ø80-140mm 2. Magnet, low profile 3. Fixture, RM/RS w level 93-170 mm 4. Magnetic probe 5. Magnetic base half bore 6. Transmitter fixture, 400 mm arm 7. Expander joint 8. Magnetic base 9. Receiver holder cc 80 mm 10. Extension fixture 100-300 mm 3 short arms and magnets for XY table, ø180-300 mm Short arms for XY table BORE Fixture kit Ø 80-500 mm 1. Fixture, RM/RS bore ø80-140mm 2. Magnet, low profile 3. Fixture, RM/RS w level 93-170 mm 4. Magnetic probe 6. Transmitter fixture, 400 mm arm 7. Expander joint 8. Magnetic base 9. Receiver holder cc 80 mm BORE Fixture kit Ø 300-1600 mm 3. Fixture, RM/RS w level 93-170 mm 4. Magnetic probe 5. Magnetic base half bore 6. Transmitter fixture, 400 mm arm 7. Expander joint 8. Magnetic base 9. Receiver holder cc 80 mm 10. Extension fixture 100-300 mm Fixtures for transmitter 800 mm Arms for transmitter fixture 800 mm

Display Unit Environmental protection: Display size: Gyroscope: Battery charging time (system off, room temperature): 1,2 kg (2,6 lbs) with battery 124 mm x 158 mm x 49 mm (4,9 in x 6,2 in x 1,9 in) P 65 (Dust tight and protected against water jets) 6,5 (165 mm) diagonal (133 x 100 mm) 6-Axis MEMS Inertial Motion Sensor with drift compensation and automatic field calibration 1 hour charge 5 hours operating time 10 hours continuous use (with 50% LCD backlight) T220 Transmitter Operating Temp: 0 to 50 C (32 to 122 F) Storage Temp: -20 to 70 C (-4 to 158 F) 3500 g Laser class: Class 2 175 x 175 x 115 mm (6.9 x 6.9 x 4.5 in) Measuring distance: Up to 50 meters (164 feet) Laser sweep flatness: ±0,02 mm/m Angular prism accuracy: ±0,02 mm/m Power supply: 4 batteries type LR6 15 hours continuously T110 Transmitter Operating Temp: 0 to 50 C (32 to 122 F) Storage Temp: -20 to 70 C (-4 to 158 F) 1100 g Laser class: Class 2 60 x 60 x 140 mm (2.4 x 2.4 x 5.5 in) Measuring distance: Up to 50 meters (164 feet) Power supply: 2 batteries type LR6 15 hours continuously BT2 Wireless Unit Wireless communication: Communication range: Power supply: 190 g (6.7 oz) with batteries 82 mm x 50 mm x 40 mm (3.2 in x 2.0 in x 1.6 in) Class II Bluetooth transmitter 10 m (33 ft) 3 AA (LR6) batteries 10 hours continuously T21 Transmitter Operating Temp: 0 to 50 C (32 to 122 F) Storage Temp: -20 to 70 C (-4 to 158 F) 1150 g Laser class: Class 2 100 x 103 x 109 mm (3.9 x 4.1 x 4.3 in) Measuring distance: Up to 20 meters (66 feet) Laser sweep flatness: ±0,02 mm/m Angular prism accuracy: ±0,02 mm/m Power supply: 2 batteries type LR6 15 hours continuously XA RM Sensor Unit 116 g (4.1 oz) 57 x 50 x 40 mm (2.2 x 2.0 x 1.6 in) Detector size: 20 mm x 20 mm (0.8 in x 0.8 in ) Measurement accuracy: 1% ± 3 µm ACOEM AB is a global player and leader in developing innovative, user-friendly equipment for shaft alignment. By helping industries worldwide to become perfectly aligned, and eliminating anything that might not be, we minimize unnecessary wear and production stoppages. This will ultimately make our customers more profitable and our environment more sustainable. P-0258-GB Fixturlaser Geometry Measurements Rev A P.O. Box 7 I SE - 431 21 Mölndal, SWEDEN I Tel: +46 31 706 28 00 I Fax: +46 31 706 28 50 I E-mail: info@fixturlaser.se I www.fixturlaser.com I