Outline. 1. Introduction 2. Why Upgrading? 3. Who Is Affected? 4. How to Upgrade? 5. Benefits of the New Upgraded UR

Similar documents
LM10 to MM200 Retrofit

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Switchgear FEATURE. Basler Electric Company

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

UR Universal Relay Series

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

Version 7.7x Release Notes

UR Universal Relay Series

GE Power Management. MMII Intelligent MCC Controller

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

GE Multilin 350 Feeder Protection Relay Specifications

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

QUALITROL QTMS Transformer Monitoring System

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

SEL Time-Domain Link (TiDL ) Technology

3 Uninterruptible Power Systems

MP7. Uninterruptible Power Supply

Asset Management through Integrated Monitoring & Diagnostics in. Protection Relays

UR Universal Relay Series

Substation Automation Products. Line differential protection RED670 Relion 670 series

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

C30. Controller System. Instruction Manual AF2. GE Grid Solutions. Product version: 7.6x GE publication code: AF2 (GEK A)

Benefits, offering and references

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

UR Universal Relay Series

HV Transmission Solutions

Uninterruptible Power Systems

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Instruction Manual. Multilin TM 8 Series Retrofit Kit * A1* GE Grid Solutions LISTED

100% electricity. Automatic transfer switch controllers ATL series

3 Uninterruptible Power Systems

Packaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

SIPROTEC 5 Protection, automation, and monitoring

UR Universal Relay Series

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Cost Effective Upgrade of Obsolete Electronics

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out

S-Series DeltaV Controller Interface for PROVOX I/O

Multilin P30 Phasor Data Concentrator

Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO!

Version 7.6x Release Notes

PowerFlex 400 AC Drive Guide Specification

APC Next Generation Rack ATS

Version 7.6x Release Notes

PowerFlex 40 Sample Specification

Teslights Hybrid Lighting SCALAMAX Protocol CA10 Head End Series. Technical Manual, DM

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Multilin 650 Family. Firmware v7.60, Software v7.60 Release Note. GE Grid Solutions. Summary

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SVX9000 Adjustable Frequency Drives. Modular, Configurable, Compact

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

IMC-P111FX / IMC-P111P Series

MultiLink. HARDENED ETHERNET SWITCHES Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets KEY BENEFITS

CG Automation Solutions User Newsletter

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Electrostatic Precipitator Controller PIACS DC4

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

IES-P3073GC Series. Industrial IEC port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.

2 NOVATECH. This page is intentionally left blank.

DGC-2000 DIGITAL GENSET CONTROLLER

Operating Manual. Micro-Ohmmeter VG - CS200 VG - CS300 VG - CS400 VG - CS600

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

The PowerLogic range. Gain energy insight and control

Providing the missing piece in your Condition Based Monitoring platform

SEL Real-Time Automation Controller (RTAC)

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Comparing Protective-Relaying Commissioning and Test Philosophies and Methods

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

UR Series. Revision 7.21 Release Notes. GE Digital Energy. Overview. GE Publication Number: GER-4631_rev2 Copyright 2013 GE Multilin Inc.

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

FT Flexitest Family. Switches, Covers and Test Plugs

Switch Mode Power Supplies

3500/22M Transient Data Interface Module

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

IMC-P111FX Series IMC-P111P Series

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

CPCI - 6U - AC - 600W

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

Spectra RMS Circuit Breakers with microentelliguard Trip Units

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Transcription:

UR Upgrade Program

Outline 1. Introduction 2. Why Upgrading? 3. Who Is Affected? 4. How to Upgrade? 5. Benefits of the New Upgraded UR 2 UR Upgrade Program 9/9/2015

1. Introduction

UR Protection and Control Devices... Proven State of the Art Family of P&C Systems Common hardware Plug and play modules Reduced stock of spare parts Reduced maintenance cost Swappable modules Modular design that delivers unparalleled flexibility and fights obsolescence

2. Why Upgrading?

Lifespan of Digital Protection Relays Determining lifespan factors of any digital relays are based on environmental conditions, application of the relay and individual component age. Old relays may: Lower the reliability and process uptime Increase in service/maintenance costs Lower personnel safety Lower the electrical equipment lifespan Not comply with new requirements (i.e. smart grids) Have problem with replacing components unavailability due to obsolesce Typical lifespan Bathtub curve Infant Mortality Weak Solder joint; cracked ceramic caps or silicon die; Design margin issues Steady State Single event burnout; Silver/NiCr corrosion; Optoisolator/LED degradation; Airborn particles Wearout Electrolytic caps; solder joint fatigue; connector corrosion; Package delamination Proactive action is crucial Solution: Retrofit

UR Power Supply Life Expectancy Continuous Design Improvements 1H Power Supply 1998 -> 2004 Design life 10 years @40DegC, confirmed by field return data At 10 year point, the device failure rate is expected to increase at a rate of 1% per year Life of Electrolytic capacitors affected by heat and electrical stress Analog subsystem susceptible to failure of C27/C28 (8V Rail) (GER-4477) Failure of 27/C28 (8V Rail) may result in incorrect metering and false trip RH Power Supply 2004 -> 2014 (Jun) Utilized newer Capacitor technology to increase design life of 15 years @40DegC At 15 year point, the device failure rate is expected to increase at a rate of 1% per year Added 200mS ride through capability KEMET Capacitor batch issue described in GER4012B (2005/2006) SH Power Supply 2014 (Jun) Eliminated C27/C28 & others, leaving only 1 long life reservoir capacitor for ride through Utilized new technology to give design life of 40 years at @45DegC 28% more output power, without increase in heat dissipation Micro controller on board to manage output rail sequencing Voltage rail monitoring to ensure analog & digital subsystems operate correctly

Solutions Retrofit by Replacing Cost of new relay, accessories and spare parts Re-engineering costs(new drawings, settings, trainings, tests, etc.) Panels modification costs(new cut-out, door, blank/drop-in plates, wiring, relocation, etc.) Service, maintenance and outage costs Months Months Days Days 1-2 Days Validate complete IED -New complete hardware -New complete Firmware Create new Engineering standards -Create new drawings -Create new settings files with reconfigured I/O -Create testing procedures -Retrain all staff on new IED & S/W Remove existing IED -Disconnect all wiring -Remove IED Create new panel cutout Install new IED -Install IED Reconnect all wiring -Test all wiring (point to-point) Commission new IED -Test all IED functions -Test all I/O from and to other devices and equipment -Test all wiring -Perform system tests

Solutions Retrofit by Upgrading Using UR Replacement kits No need to replace the relay Not offered by all vendors No panel modification needed Compatible with the existing protection and control system Limited service, maintenance and outage costs Enhanced functionalities and new generation relay features Relays more than almost 10-year old are concerned. Modular design provides seamless upgrades resulting in average savings of 50% on retrofit project.

UR Upgrade Program Fast Replacement Eliminates Rewiring & Reconfiguration Unique Modular draw out mechanism (no panel cut-out required) Easy upgrade & retrofit without disturbing existing wiring Draw out aged relay modules and install new modules - plug & use (no reconfiguring of I/O wiring to fit new terminal boards) Minimize training & labor hours required for commissioning reduce service costs (no wiring test and terminal inspection required, No tools required (replace all modules)) UR Setup software compatibility (easy transfer of existing protection setting schemes) File conversion, file version selector, and file comparison tools for quick setpoint file modifications Weeks Weeks <1 Hour Hours Hours Validate Only changes -Only new CPU and DSP -New firmware features Update existing Engineering Standards -Update drawings -Convert settings files -Update testing procedures -Train staff only on changes No need to remove existing UR -Disconnect only communication wiring -UR chassis remains -No new panel cut-out Replace UR modules -Remove old modules -Install new modules -Reconnect communications wiring Maintenance test UR -Check all analog values -Test enabled functions -Test all UR I/O only 10 UR Upgrade Program 9/9/2015

UR Upgrade Program Easy transition to enhanced next generation functions Upgrade for a better reliability and security Proactive approach to compensate for electronic component aging New technological advancements on UR protective relaying systems Commitment on enhanced product performance improvement Simplified process for ease of upgrade transition Arrange for advance replacements to meet scheduled outages Hardware upgrade kits available with an Upgrade Guide for seamless upgrades Economical solution to revamp existing installed base products Proactive upgrade would minimize maintenance labor costs and maximize process uptime Offers special discounted rates on upgrade 11 UR Upgrade Program 9/9/2015

3. Who Is Affected?

Upgrade Recommendation Upgrade recommended for UR Devices 10 years and older The recommended replacement for UR relays (versions 3.5 or below): CPU versions T, U, V DSP versions L, M, N, R, S Firmware versions: 7.xx and above If existing standards dictate other versions, they can be offered. CPU and DSP modules have to be changed, i.e. version 3 DSP s are not compatible with later versions. UR Relays with Firmware 3.5 and below CPU Cross Reference UR 3 CPU A C D Recommended UR 7 CPU T, U or V. If 2 serial ports required, UR 9E T or U T or U UR Relays with Firmware 3.5 DSP Cross Reference UR 3 DSP Recommended UR 7 DSP 8A 8L 8B 8M 8C 8N 8D 8R 13 UR Upgrade Program 9/9/2015

4. How to Upgrade?

Upgrade Process Simple selection, Fast replacement, Easy set-up, Economical Determine if upgrade is required. UR model and serial numbers Existing firmware version Obtain the replacement kits. CPU-type required Specific firmware required Additional software options Contact local GE sales office Settings conversions. By latest EnerVista UR setup software Do it yourself guide: Upgrade guide! Modules replacement Follow UR3 upgrade guide (GET-8550) Pre-in-service checks and testing Visual verification In-service maintenance tests Out-of-service maintenance tests 15 UR Upgrade Program 9/9/2015

5. Benefits of the New Upgraded UR

Single Platform, Scalable Solution Incrementally Scalable Single Platform Solution

UR Feature Enhancements-I Proactive approach towards enhanced quality, reliability and functionality Protection Multiple new applications Breaker and a half capabilities for D60 and L90 Breaker failure support for B30 and G60 Incipient cable fault detection for F35 and F60 New Trip Bus for all UR models Watt-metric ground for D60, F60 and L90 Voltage-dependent overload and Broken Rotor Bar for M60 100% stator and rotor using the GPM and Split-phase protection (G60) Teleprotection Inputs/Outputs for: B30, C30, C60, D60, F35, F60, G60, M60, T35 and T60 Control Enhanced breaker control: block open/close; double-point status per phase with alarming Autorecloser extended to 4 shots, selectable activation modes and breaker initiated Additional control functions (Capacitor, PID regulator, AVR)

UR Feature Enhancements-II From Firmware V3.50 to V7.xx Monitoring New elements for Power system components (CTs) monitoring Breaker arching for B30, C60, D60, F35, G60, L90, M60, T35 and T60 PMU functionality on D60, L90, G60, G60, F60, T60 Internal hardware monitors on DSP and voltage rails Communication Enhanced IEC 61850, IEC62439 PRP and IEEE 1588 PTP, IEC 103 Hard-fiber (61850 Process Bus) Enhancements to PMU and other protocols Reliability Enhanced environmental monitoring and capabilities New DSP failure mode with enhanced diagnostic DSP Enhanced design, validation and manufacturing processes

UR Feature Enhancements-III Bringing more to power system installations Software Selected settings auto-configuration One click records retrieval Settings templates and more Security Role-based access control Audit & recovery CyberSentry level 1 with Radius and Syslog support Meet well known NERC CIP standard Additional features: access control, intrusion detection & prevention, audit Platform Enhancement Enhanced CPU and DSP Upgraded I/O & inter relay modules New power supply Multiple languages

UR Hardware Enhancements More Powerful CPU and Power Supply CPU Speed: much faster (400MHz vs. 64MHz) Memory: 8 times more for events and oscillography and much faster (from SDRAM to DDR2) Three independent Ethernet ports (MAC and IP addresses) Maintains backward compatibility with existing hardware Three types of CPU Modules Power Supply Higher input voltage range (88 to 400VDC vs. 88 to 300VDC) Overall output power increased (45W vs. 35W) Voltage Rail monitoring on all rails vs. none Isolation voltage level (2300VAC vs. 2000VAC) limited use of electrolytic capacitors for ride-through 1 vs. 27 in LV & 10 in HV) Microcontroller based power supply control vs. none Over temperature protection vs. none

Summary Best solution for relay retrofit without replacing it Not offered by other vendors Lower service, maintenance and outage time Enhanced reliability, Improved Performance Easy transition to enhanced next generation relay systems Ease of upgrade / replacement Compatibility with smart grid emerging needs. Use of well known UR strengths Under 10 year warranty coverage 22 UR Upgrade Program 9/9/2015