SmartLock Controller INSTALLATION MANUAL

Similar documents
SmartLock Pro INSTALLATION MANUAL

Zodiac FR100 TM INSTALLATION MANUAL

Quick Start Installation Guide

Quick Start Installation Guide

6222 Two Door Module Technical Operations Manual

SmartLock Surf QUICK START GUIDE

Canlan INSTALLATION MANUAL

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

SmartLock Surf OPERATOR GUIDE

UC-2000 Installation Manual Unicorn Computers Technology Limited

This is Cansec s 25th anniversary. Many of

Installation & Operation Guide

Two Door Controller GEN-045

istar Pro Installation Guide

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

CA-A480-A Elevator Controller. Reference & Installation Manual

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

SAVE THESE INSTRUCTIONS

PXL-250 Tiger Controller

Quick Installation Manual

Installation Instructions for the AUTOcard-SA System

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

EP1501 Intelligent Controller

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Suprex RS-485 SPX-7500 Wired Reader-Extender

BioPointe Reader Installation Guide

DESIGN GUIDE FOR INFINITY SYSTEMS

Quick Start Installation Guide

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Installation / Setup Manual

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

EA500. Installation Instructions Transponder

TAC I/NETTM 1284, 1280, Security Control Unit

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

SAVE THESE INSTRUCTIONS

IEI emerge MicroNode Install and Setup Guide. Contents

B100 Installation Manual

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PS-4100 POWER SUPPLY MANUAL

INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM. Doc Rev B

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

Expandable Power Systems

Model HM-535 Power Supply Installation and Service Instructions

First Access Express OPERATOR GUIDE

2000 Series e/em Style Keypad Installation and Programming Manual

Supervised Input Module Installation Manual

MR51e Reader Interface

emerge Essential Access Control System

APK INSTALLATION GUIDE

Andover ContinuumTM Infinet II

Quick Start Installation Guide

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

PRO3200 Professional Modular Access Control Hardware

ACX Series. Access Controller for Ethernet

Copyright Keyscan Inc. All rights reserved.

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

RTD-NET Installation Instructions

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET

Click Save to return to the main Setup screen.

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

IQX and NRX Series Intelligent Access Control Systems IQX and NRX Series Installation Manual REV: D

Wiring Instructions v4

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Installation Instructions

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

PRT-RDS2 Standard 2 Reader Expander

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

U-FLASH Setup Guide U-FLASH.

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

721EX Access Controller Installation

ACTpro 1500 Single Door IP Controller

LQSE-4S8-120-D. 120 V~ 50 / 60 Hz 16 A. lutron.com LQSE-4S8-120-D. Dimming Power Module. Option. Input. Opt Def H M

Wiring Instructions. Gatekeeper h4.0. Technical Support.

232iLM Keypad Installation and Programming Instructions

MR52 READER INTERFACE

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

1.0 Wiring and Layout Diagrams

PRO2200 Professional Modular Access Control Hardware

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

TruPortal Dual Door Interface Module Quick Reference

SmartLock Pro Plus OPERATOR GUIDE

BACnet. b3810 Series Local Controllers

PRT-PX16 16 PGM Output Expander

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

How to Install a PowerNet IPBridge

Transcription:

SmartLock Controller INSTALLATI MANUAL November 2015

Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting... 9 RS-485 COMMUNICATIS WIRING...10 CLAUSB Communications Device...10 CANLAN Network Communications Device...10 AIR-485 Communications Device...12 READER WIRING...13 Wiegand Reader...13 ibutton Reader...14 LOCK OUTPUT RELAY WIRING...15 DC Electric Strikes...15 DC MagLocks...16 AC MagLocks and AC Electric Strikes...17 INPUT WIRING...18 Exit Button, Handicap Button, Door Contact...18 OUTPUT WIRING...19 Door Operator, Forced Entry, Door-Held-Open...19 DIP SWITCH...20 Function...20 Location...20 Erase Controller Memory, Diagnostics...21 Door Contact Bypass Switch Setting...22 CTROLLER ADDRESS TABLE...23 APPENDIX...25 CLA50 Communications Wiring...25 CLAUSB2 Communications Wiring...25 SmartLock Controller Page 2 of 26

CAUTI: EMERGENCY LOCKDOWN Emergency lockdown functions must operate totally independent of the access control system and must not rely on operation of card readers, access control panels, communications networks, communications devices or host software. Cansec accepts no responsibility for direct or consequential damages resulting from the failure of emergency lockdown functions which are dependant in any way on the operation of card readers, access control panels, communications networks, communications devices or host software. CA-PS123A Specifications Notice: When using a pluggable 16 VAC standard 40 VA transformer: Maximum Continuous Current (no battery attached): 2 amps for 12 VDC on the Output. Maximum Continuous Current (battery attached): 1.5 amps for 12 VDC on the Output (battery will be charging when needed). Using a wire in 16 VAC standard 75 VA transformer: Maximum Continuous Current (no battery attached): 2.5 amps for 12 VDC on the Output. Maximum Continuous Current (battery attached): 2.0 amps for 12 VDC on the Output (battery will be charging when needed). Surge currents need to be taken into account. High current devices like electric strikes and magnetic locks have surge currents which are usually double the running current. The CA-PS123A s DC output is fused at 2.5 amps. An electrician is not required for installation of this supply. SmartLock Controller Page 3 of 26

Introduction The SmartLock access control panel is a single door controller with inputs for both entry and exit readers. Readers and card formats supported include Cansec 37, 26 and 35-bit Corporate 1000 Wiegand formats, and Cansec ibutton credentials. Other card formats can be accommodated with the use of Cansec Protocol Converters (contact Cansec for further information). SmartLock controllers with Pro Plus firmware (SLPPx.x) only work with SmartLock Pro Plus software. SmartLock controllers with Pro firmware (SLPTx.x) only work with SmartLock Pro, SmartLock Managed Access and SmartLock Surf software. The SmartLock control panel stores all cardholder data in non-volatile memory to ensure continued operation and security in the event that communications are lost to the host PC. Up to two control panels are easily mounted in a SmartLock enclosure along with a Cansec 12 VDC power supply and a back-up battery. DIODES Diodes are required for inductive loads such as electric strikes/locks. Failure to use appropriate diodes will void the control panel warranty. IMPORTANT: In some jurisdictions, the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required. Installers should contact the local authority having jurisdiction to verify the specific requirements. Also, a building permit may be required in some jurisdictions for the installation of maglocks. SmartLock Controller Page 4 of 26

TERMINAL STRIPS AND CABLE Use Appropriate Cable Thickness For optimal performance and communication, the terminal strips on the SmartLock control panel are designed to be used with 26 18 American Wire Gauge (AWG) stranded, overall-shielded, twisted-pair cable. This is equivalent to Belden 88761 or similar cable. Use MARR Connectors If you are bringing in cable that is too large for the terminal strip, use a MARR connector (wire nut, marrette, thimble connector, cone connector). Splice the thicker cable to a cable that is the appropriate thickness, and then run the thinner cable to the terminal strip on the control panel. Use Splices for Parallel Wiring The terminal strips are designed to allow one cable per hole. If you need to connect multiple cables in a single hole, use a MARR connector (wire nut, marrette, thimble connector, cone connector). Splice multiple cables to a single cable, and then run the single cable to the terminal strip on the control panel. Complimentary Screwdriver A standard Cansec screwdriver is included with every control panel for use with terminal strips. NOTE: Tech Support will only be provided where product installation guidelines have been followed. SmartLock Controller Page 5 of 26

Specifications Power Requirements SmartLock Controller:... 12 VDC, 50 ma NOTE: When determining power supply current requirements, you must consider lock and reader current draw if using the same supply for these devices. IMPORTANT: In some jurisdictions, the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required. Installers should contact the local authority having jurisdiction to verify the specific requirements. Also, a building permit may be required in some jurisdictions for the installation of magnetic locks. NOTE: If a gate operator is being used in place of a lock then an external relay is recommended between the controller and the gate operator. The relay must have a diode installed to prevent back EMF from damaging the controller. Communications Cable (multi-drop configuration) RS-485 Cable:... 22 AWG, Stranded/Shielded, Twisted Pair... 609 m (2000 ft) max total length... Belden 88761 or equivalent On-Board Outputs Lock Control:... Form C, Rated @ 30 VDC, 1A Door Operator:... Form C, Rated @ 30 VDC, 1A Forced/DHO Relays:... Form C, Rated @ 30 VDC, 1A On-Board Inputs Exit Button:... Normally Open Door Contact:... Normally Closed Door Operator:... Normally Open... SmartLock Controller Page 6 of 26

Reader Cable Wiegand Readers:... 6 conductor (twisted pair not required)... 22 AWG, overall shield... 152 m (500 ft) max total length ibutton Readers:... 6 conductors... 22 AWG, shielded or unshielded... 15 m (50 ft) max total length Dimensions & Weight Controller Board:... 84 mm (l) x 65 mm (w)... [ 3 5/16 (l) x 2 9/16 (w) ] SmartLock Cabinet:... 260 mm (l) x 216 mm (w) x 80 mm (h)... [ 10 1/4 (l) x 8 1/2 (w) x 3 1/8 (h) ] Weight:...2 kg (4.5 lbs) Specifications subject to change without notice. SmartLock Controller Page 7 of 26

OFF SmartLock Controller Layout WIEGAND DATA LED 8 1 FORCED / DHO DOOR OPER. LOCK +5V +12V +12 VDC INPUT EXIT READER (WIEGAND) READER VOLTAGE SELECTOR DEFAULT (DO NOT CHANGE) FIRMWARE CHIP ADDRESS SWITCH 1 2 3 4 5 6 7 8 ENTRY READER (WIEGAND) ENTRY READER or PROGRAMMING MODULE (ibutt) RELAY LEDS COMMS LED DOOR CTACT EXIT BUTT DOOR OPERATOR (INPUTS) RS-485 COMMUNICATIS LOCK CTROL DOOR OPERATOR FORCED/HELD OPEN (OUTPUTS) Important Notes: 1. Each controller must have a unique address. Refer to the Controller Address Table. 2. Exit reader must be Wiegand only. Native ibutton reader not supported for exit. 3. Before connecting readers with power, make sure Reader Voltage Selection Jumper is set to proper voltage for reader, otherwise the reader may be damaged. 4. Do NOT connect power to any inputs on the controller. 5. The Door Contact Input should be bypassed, if not used, by using a jumper wire across the input or setting the switch to ignore the input. Refer to the Door Contact Bypass Switch Setting. 6. This controller utilizes self-resetting fuses. There are no field-serviceable parts. SmartLock Controller Page 8 of 26

LED INDICATORS 1. Relay LEDs turn RED when the corresponding relay is or ACTIVATED. 2. The Wiegand data LED is normally and briefly flickers when valid Wiegand data is received from the reader. If Wiegand data is not valid or not supported, this LED will stay OFF until the next valid card is read. 3. The communication LED will flicker GREEN while communicating with SmartLock software. MOUNTING Up to two SmartLock controllers can be mounted in the SmartLock enclosure along with a Cansec 12 VDC power supply and a backup battery. SmartLock Controller Page 9 of 26

RS-485 OFF 8 1 +5V +12V OFF 8 1 +5V +12V RS-485 Communications Wiring Up to 30 SmartLock access control panels may be connected on an RS-485 bus. NOTE: For legacy CLA50 and CLAUSB2 communications device wiring please see Appendix section. CLAUSB COMMUNICATIS DEVICE GND +12 VDC SMARTLOCK CTROLLER #1 NOTES: - Each Smartlock controller must have a unique address ADDRESS 1 SHOWN (Dipswitch 1 is OFF) - For communication wiring, use 22 AWG, twisted pair, stranded, shielded cable, 2000 ft ( 609 m) MAX total length. 1 2 3 4 5 6 7 8 GND +12 VDC SMARTLOCK CTROLLER #2 - Use the CLAUSB factory default jumper settings for communications with Smartlock controllers. DO NOT open the CLAUSB and change the jumper settings. COMMS LED B A GND B A GND ADDRESS SWITCH TO USB PORT (CABLE SUPPLIED) SHIELD SHIELD DIPSWITCH SETTINGS 1 2 3 4 USB SW 6 5 4 3 2 1 PWR RxD TxD CLAUSB Serial B A GND TO OTHER SMARTLOCK CTROLLERS - 30 CTROLLERS MAXIMUM - 609 m (2000 ft.) MAXIMUM LENGTH NOTE: The EIA RS-485 standard does not permit T-Tap or Star connections. SmartLock Controller Page 10 of 26

CANLAN NETWORK COMMUNICATIS DEVICE NOTE: The EIA RS-485 standard does not permit T-Tap or Star connections. SmartLock Controller Page 11 of 26

AIR-485 COMMUNICATIS DEVICE NOTE: The EIA RS-485 standard does not permit T-Tap or Star connections. SmartLock Controller Page 12 of 26

Reader Wiring WIEGAND READER CABLE: 22 AWG, 6 CDUCTORS, N-TWISTED PAIR, OVERALL SHIELDED, MAX. DISTANCE IS 500ft (152 m). IMPORTANT: Before applying power to the controller, verify that the reader voltage jumper is set correctly for the reader being connected. Connecting a 5 V reader to a 12 V power supply will damage the reader. NOTE: The SmartLock controller supports Cansec s 37-bit format as well as standard 26-bit format. SmartLock Controller Page 13 of 26

ibutt READER NOTE: Exit reader not supported with SmartLock ibutton readers. NOTE: If using the SmartLock Connect Programming Module with ibutton readers, connect the programming module in parallel with the ibutton reader. SmartLock Controller Page 14 of 26

Lock Output Relay Wiring DC ELECTRIC STRIKES 500 ma > 500 ma NOTE: Use 1N400x series diode as shown, to prevent back EMF from damaging the controller. SmartLock Controller Page 15 of 26

DC MAGLOCKS 500 ma > 500 ma NOTE: Use 1N400x series diode as shown to prevent back EMF from damaging the controller if the maglock is not equipped with sufficient spike and surge protection. Check the maglock specifications for details. IMPORTANT: In some jurisdictions, the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required. Installers should contact the local authority having jurisdiction to verify the specific requirements. Also, a building permit may be required in some jurisdictions for the installation of maglocks. SmartLock Controller Page 16 of 26

AC MAGLOCKS AND AC ELECTRIC STRIKES IMPORTANT: In some jurisdictions, the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required. Installers should contact the local authority having jurisdiction to verify the specific requirements. Also, a building permit may be required in some jurisdictions for the installation of maglocks. SmartLock Controller Page 17 of 26

Input Wiring EXIT BUTT, HANDICAP BUTT, DOOR CTACT IF YOU ARE CNECTING A DOOR CTACT SET DIP SWITCH 8 TO OFF (LEFT) IF YOU ARE NOT CNECTING A DOOR CTACT SET DIP SWITCH 8 (RIGHT) EXIT BUTT - NORMALLY OPEN - MOMENTARY TO ACTIVATE OFF 1 2 3 4 5 6 7 8 HANDICAP BUTT - NORMALLY OPEN - MOMENTARY TO ACTIVATE - ENABLED LY AFTER VALID CARD OR EXIT BUTT EXIT HC DOOR CTACT - NORMALLY CLOSE DC NOTE: DO NOT apply power or attempt to switch any current through these inputs as this will result in damage to the controller. NOTE: If not connecting a door contact, make sure you set switch position 8 to (right in orientation shown) to bypass/disable the door contact input. Otherwise, the door will be in alarm condition. NOTE: Exit Button requires momentary closure to activate relay. Door Contact is used for forced-entry and door-held-open annunciation, and also deactivates the lock relay when the door closes. SmartLock Controller Page 18 of 26

Output Wiring DOOR OPERATOR, FORCED ENTRY, DOOR-HELD-OPEN Use dry contact relays. 8 1 FORCED / DHO DOOR OPER. LOCK OFF +5V +12V 1 2 3 4 5 6 7 8 SET RELAY CTACTS RELAY LEDS TURN ACTIVATI RED = = : RELAY CLOSES ACTIVATI : RELAY OPENS ACTIVATI DOOR OPERATOR OUTPUT ACTIVATED MOMENTARILY WHEN HANDICAP BUTT IS DEPRESSED AFTER LOCK RELAY IS ACTIVATED. FORCED ENTRY/DHO OUTPUT ACTIVATED FORCED ENTRY AND/OR DHO ALARM AS CFIGURED IN SOFTWARE NOTE: Maximum power through any of these relays is 30 VDC at 1 A. NOTE: Door Operator requires momentary closure to activate relay. SmartLock Controller Page 19 of 26

OFF DIP Switch FUNCTI FORCED / DHO DOOR OPER. LOCK +5V +12V The DIP switch is used: to erase the controller s memory and run diagnostics to set the baud rate to enable or bypass the door contact input to set the controller address from 1 to 30. LOCATI DIP SWITCH WIEGAND DATA LED 8 1 1 2 3 4 5 6 7 8 COMMS LED SmartLock Controller Page 20 of 26

ERASE CTROLLER MEMORY, DIAGNOSTICS 1. Disconnect communication and device wiring. 2. To erase controller memory (factory default), set all switches to the OFF position (left on diagram above). 3. Disconnect power from the board momentarily then re-connect power. 4. The controller s memory will be erased. All three relays will cycle OFF once the memory has been cleared. Relay outputs can be verified during this stage. NOTE: If the relays do not cycle OFF, there may be a problem with the unit. 5. Continue to set controller address and door contact bypass switch settings. SET CTROLLER BAUD RATE The default baud rate is 9600 bps with dip switch #7 set to on position. SmartLock Pro, with firmware version 1.56 and up, also supports 38,400 bps. Follow the steps below to adjust the baud rate. 1. Set dip switch #7 to off position to enable 38,400 bps. 2. Ensure that the setting in the software is set to 38,400. NOTE: Switch setting changes do not take effect until the power is disconnected, then reconnected. SmartLock Controller Page 21 of 26

FORCED / DHO DOOR OPER. LOCK +5V +12V DOOR CTACT BYPASS SWITCH SETTING IF YOU ARE CNECTING A DOOR CTACT SET DIP SWITCH 8 TO OFF (LEFT) IF YOU ARE NOT CNECTING A DOOR CTACT SET DIP SWITCH 8 (RIGHT) WIEGAND DATA LED OFF 1 2 3 4 5 6 7 8 COMMS LED Door Contact Connected: Set switch 8 OFF (LEFT on diagram) Door Contact Not Connected: Set switch 8 (RIGHT on diagram) NOTE: If door contacts are not installed, but door contacts are enabled on the control panel via switch 8, unlock schedules will fail to take effect. SmartLock Controller Page 22 of 26

Controller Address Table Set the unique address of each controller from 0 to 30 as per the table below. The same address used must be programmed in the software in order to establish communications. Switch setting changes do not take effect until the power is disconnected, then reconnected. ADDRESS SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 1 OFF 2 OFF 3 OFF OFF 4 OFF 5 OFF OFF 6 OFF OFF 7 OFF OFF OFF 8 OFF 9 OFF OFF 10 OFF OFF 11 OFF OFF OFF 12 OFF OFF 13 OFF OFF OFF 14 OFF OFF OFF 15 OFF OFF OFF OFF 16 OFF 17 OFF OFF 18 OFF OFF 19 OFF OFF OFF 20 OFF OFF SmartLock Controller Page 23 of 26

ADDRESS SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 21 OFF OFF OFF 22 OFF OFF OFF 23 OFF OFF OFF OFF 24 OFF OFF 25 OFF OFF OFF 26 OFF OFF OFF 27 OFF OFF OFF OFF 28 OFF OFF OFF 29 OFF OFF OFF OFF 30 OFF OFF OFF OFF NOTES: 1. Switch setting changes do not take effect until the power is disconnected, then reconnected. SmartLock Controller Page 24 of 26

RS-485 OFF +5V +12V OFF 8 1 +5V +12V Appendix CLA50 COMMUNICATIS WIRING GND +12 VDC SMARTLOCK CTROLLER NOTES: - Each Smartlock controller must have a unique address ADDRESS 1 SHOWN (Dipswitch 1 is OFF) - For communication wiring, use 22 AWG, twisted pair, stranded, shielded cable, 2000 ft ( 609 m) MAX total length. 1 2 3 4 5 6 7 8 GND +12 VDC SMARTLOCK CTROLLER #2 - DO NOT open the CLA50 and change the jumper settings or DIP switch settings. COMMS LED ADDRESS SWITCH 8 1 NOTE: The EIA RS-485 standard does not permit T-Tap or Star connections. B A GND B A GND GND B A SHIELD SHIELD B A GND TO OTHER SMARTLOCK CTROLLERS - 30 CTROLLERS MAXIMUM - 609 m (2000 ft.) MAXIMUM LENGTH TO COMPUTER DB9 SERIAL PORT (CABLE SUPPLIED) 12 VDC PLUG IN TRANSFORMER 2.1 mm PLUG, CENTRE POSITIVE (SUPPLIED) SmartLock Controller Page 25 of 26

CLAUSB2 COMMUNICATIS WIRING SmartLock Controller NOTE: The EIA RS-485 standard does not permit T-Tap or Star connections. SmartLock is a registered trademark of Cansec Systems Ltd. ibutton is a registered trademark of Maxim Integrated Products, Inc. SmartLock Controller Page 26 of 26