Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

s Spring return C / max C

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Technical data sheet. Technical data

Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data sheets

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

Brief description. Type overview

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Brief description. Type overview

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Products no longer available

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Products no longer available

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Technical data. Safety notes. Product features

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

VAV system solution for non-pressure dependent applications in enclosed spaces

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Technical data sheet

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Belimo Gateway MP to Modbus RTU - UK24MOD

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

BUS. Adaptive control system for pressure applications (STP) Table of contents

Belimo Gateway MP to Modbus RTU - UK24MOD

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Air Damper Actuators Modbus RTU

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ZN230-24MP-1 MP-BUS

Installation VAV-Compact Retrofit Set

Air Damper Actuators Modbus RTU

VAV Compact Controller Modbus RTU

Rotary version, three-position control

VAV compact controller KNX / PL-Link

BUS. Adaptive VAV control system for sensitive working areas. Table of contents

VAV compact controller GDB181.1E/3 GLB181.1E/3

Power consumption motor (motion) 2,5 W Power consumption standby (end position) 1,0 W. Position feedback -

Air damper actuators

InReg Volume flow controller Pa

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

InCos-P Pressure sensor 20 Pa Pa

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Rotary actuators for ball valves

Super universal modules

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

SIMOCODE 3UF Motor Management and Control Devices

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

AIAS. Technical description

EY-EM : Remote I/O module, ecolink

VAV compact controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Actuators for CAV control lers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Digital input modules

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

I/O module, universal, digital, S0 inputs, modu533

Digital electropneumatic positioner SideControl

RXTH DUAL ROOM SENSOR / SWITCH

EC centrifugal module - RadiPac

Zelio Control-modular measurement and control relays 1

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

THERMOSTATS & CONTROLLERS

em4 Accessories Digital expansions

Installation instructions Inclination sensor EC2019 EC / / 2013

Digital electropneumatic positioner

Room Temperature Controller

ARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function

Transcription:

echnical data sheet SF24A-MOD Communicative spring-return actuator with emergency control function for adjusting dampers in technical building installations orque motor 20 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet MS/P, Modbus RU, Belimo-MP-Bus or conventional control echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 8.5 W Power consumption in rest position 3.5 W Power consumption for wire sizing 11 VA Connection supply / control Cable 1 m, 6 x 0.75 mm² Functional data Nominal torque Min. 20 Nm orque spring return 20 Nm Communicative control BACnet MS/P Modbus RU (ex works) MP-Bus Operating range Y DC 2...10 V Operating range Y variable DC 0.5...10 V Position feedback U DC 2...10 V Position feedback U note Max. 1 ma Position feedback U variable Start point DC 0.5...8 V End point DC 2...10 V Position accuracy ±5% Direction of motion motor selectable with switch L / R Direction of motion emergency control selectable by mounting L / R function Manual override by means of hand crank and locking switch Angle of rotation Max. 95 Angle of rotation note adjustable starting at 33% in 2.5% steps (with mechanical end stop) Running time motor 150 s / 90 Running time motor variable 70...220 s Running time emergency control position <20 s / 90 Running time emergency setting position @ -20...50 C / <60 s @ -30 C note Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control, controllable via bus communication MAX (maximum position) = 100% MIN (minimum position) = 0% ZS (intermediate position) = 50% Override control variable MAX = (MIN 32%)...100% MIN = 0%...(MAX 32%) ZS = MIN...MAX Sound power level Motor 40 db(a) Damper spindle Universal spindle clamp 10...25.4 mm Position indication Mechanical Service life Min. 60,000 emergency positions Safety Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Protection class UL UL Class 2 Supply Degree of protection IEC/EN IP54 www.belimo.com SF24A-MOD en-gb 2018-04-26 subject to changes 1

echnical data Safety Degree of protection NEMA/UL NEMA 2, UL Enclosure ype 2 EMC CE according to 2014/30/EU Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14 Certification UL culus according to UL60730-1A, UL60730-2- 14 and CAN/CSA E60730-1:02 Mode of operation ype 1.AA Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature -30...50 C Non-operating temperature -40...80 C Ambient humidity Max. 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 2.4 kg Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. Cables must not be removed from the device. o calculate the torque required, the specifications supplied by the damper manufacturers concerning the cross-section, the design, the installation site and the ventilation conditions must be observed. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Combination analogue - (hybrid mode) Simple direct mounting Manual override Adjustable angle of rotation High functional reliability he actuator is fitted with an integrated interface for BACnet MS/P, Modbus RU and MP-Bus. It receives the digital positioning signal from the control system and returns the current status. Connection option for a sensor (passive, active or with switching contact). In this way, the analogue sensor signal can be easily digitised and transferred to the bus systems BACnet, Modbus or MP-Bus. he factory settings cover the most common applications. Single parameters can be modified with the Belimo Service ools MF-P or ZH EU. he communication parameters of the bus systems (address, baud rate etc.) are set with the ZH EU. Pressing the Address button on the actuator while connecting the supply voltage, resets the communication parameters to the factory setting. Quick addressing: he BACnet and Modbus address can alternatively be set using the buttons on the actuator and selecting 1 to 16. he value selected is added to the «Basic address» parameter and results in the effective BACnet and Modbus address. With conventional control by means of an analogue positioning signal, BACnet or Modbus can be used for the position feedback Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating. By using the hand crank the damper can be actuated manually and engaged with the locking switch at any position. Unlocking is carried out manually or automatically by applying the operating voltage. Adjustable angle of rotation with mechanical end stops. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. 2 SF24A-MOD en-gb 2018-04-26 subject to changes www.belimo.com

Product features Home position Adaption and synchronisation he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after actuating the hand crank is programmed. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. A range of settings can be adapted using the PC-ool (see MF-P documentation) Accessories Description Electrical accessories Auxiliary switch, 2 x SPD S2A-F Feedback potentiometer, 200 Ohm, incl. installation accessories P200A-F Feedback potentiometer 1 kohm, incl. installation accessories P1000A-F Connecting cable 5 m, AB: RJ12 6/6, o ZH EU ZK1-GEN Connection cable 5 m, A: RJ11 6/4, B: Free wire end, o ZH EU ZK2-GEN ype Mechanical accessories Description ype Shaft extension 240 mm, for damper spindles Ø 8...25 mm or Ø AV8-25 10...25 mm End stop indicator for NF..A / SF..A INAFB Spindle clamp set for NF..A/SF..A (1, 3/4, 1/2 ) K7-2 Straight ball joint with M8, suitable for damper crank arm KH8 KG10A Angled ball joint with M8, suitable for damper crank arm KH8 KG8 Damper crank arm, for damper spindles KH8 Damper crank arm for NF..A / SF..A, for 3/4 spindles KH-AFB Form fit insert 10x10 mm, for NF..A / SF..A ZF10-NSA-F Form fit insert 12x12 mm, for NF..A / SF..A ZF12-NSA-F Form fit insert 16x16 mm, for NF..A / SF..A ZF16-NSA-F Damper crank arm, for spring return actuators NG ZG-AFB Base plate extension for NF..A / SF..A Z-SF Anti-rotation mechanism 230 mm Z-ARS230L Hand crank 63 mm for BFL, BFN, NF..A / SF..A / EF..A ZKN2-B Description Service ools Service tool for parametrisable and Belimo actuators / VAV controller and HVAC performance devices Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH EU MF-P MF-C Electrical installation! Notes Connection via safety isolating transformer. he wiring of the line for BACnet MS/P / Modbus RU is to be carried out in accordance with applicable RS485 regulations. Modbus / BACnet: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another. www.belimo.com SF24A-MOD en-gb 2018-04-26 subject to changes 3

Electrical installation Wiring diagrams BACnet MS/P / Modbus RU GND D AC/DC 24 V 3 5 6 7 D AC/DC 24 V 3 5 6 7 D Cable colours: 1= black 2 = red 3 = white 5 = orange 6 = pink 7 = grey Signal assignement Modbus: C1 = D = A C2 = = B Connection with passive sensor, e.g. Pt1000, Ni1000, NC D 3 5 6 7 Ni1000 28...98 C 850...1600 Ω 2) MF D P1000 35...155 C 850...1600 Ω 2) NC 10...160 C 1) 200 Ω...60 kω 2) 1) depending on type 2) Resolution 1 Ohm Connection with active sensor, e.g. 0...10 V @ 0...50 C 3 5 6 7 MF D - Possible voltage range: 0...32 V (resolution 30 mv) Connection with switching contact, e.g. Δp monitor p 3 5 6 7 MF D - Requirements for switching contact: he switching contact must be able to accurately switch a current of 16 ma @ 24 V. 4 SF24A-MOD en-gb 2018-04-26 subject to changes www.belimo.com

Electrical installation Modbus RU / BACnet MS/P with analog setpoint (hybrid mode) GND Y U DC (0)2 10 V DC 2 10 V 3 5 6 7 AC/DC 24 V Operation on the MP-Bus Y U Sensor MP 3 5 6 7 MF Operating controls and indicators 3 Adaption Address Power Status 1 Membrane key and LED display green Off: No power supply or malfuntion On: In operation Flashing: In address mode: Pulses according to set address (1...16) When starting: Reset to factory setting (Communication) Press button: In standard mode: riggers angle of rotation adaptation In address mode: Confirmation of set address (1...16) 3 Push-button and LED display yellow Off: On: Flickering: Press button: Standard mode Adaptation or synchronising process active or actuator in address mode (LED display green flashing) BACnet / Modbus communication active In operation (>3 s): Switch address mode on and off In address mode: Address setting by pressing several times When starting (>5 s): Reset to factory setting (Communication) 3 Service plug For connecting parameterisation and service tools Operating elements he manual override, locking switch and direction of rotation switch elements are available on both sides www.belimo.com SF24A-MOD en-gb 2018-04-26 subject to changes 5

Service Quick adressing Service ools connection 1. Press the Address button until the green Power LED is no longer illuminated. LED flashes in accordance with the previously set address. 2. Set the address by pressing the Address button the corresponding number of times (1-16). 3. he green LED flashes in accordance with address that has been entered (1-16). If the address is not correct, then this can be reset in accordance with Step 2. 4. Confirm the address setting by pressing the green Adaption button. If no confirmation occurs for 60 seconds, then the address procedure is ended. Any address change that has already been started will be discarded. he resulting BACnet MS/P and Modbus RU address is made up of the set basic address plus the short address (e.g. 1007=107). he actuator can be parameterised by ZH EU via the service socket. For an extended parameterisation the PC tool can be connected. AC 24 V DC 24 V 3 5 6 7 MP USB ZH EU i esc OK BELIMO PC-ool MF D USB Dimensions [mm] Spindle length Dimensional drawings L Clamping range Min. 85 Min. 15 60 20.5 93 10...22 10 14...25.4 12.5 19...25.4 12...18 80 98 32 27 162 172 182 236 Further documentation ool connections Description Protocol Implementation Conformance Statement PICS Description Modbus register Overview MP Cooperation Partners MP Glossary Introduction to MP-Bus echnology 6 SF24A-MOD en-gb 2018-04-26 subject to changes www.belimo.com